Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 2019PRECAST H-10 RISERS (TYP.) 2'0 22.85' SYSTEM PROFILE PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE 25.4' MINIMUM .75' OF COVER OVER PRECAST NOTE: 2" MIN. WALL 6" MIN. SUMP THICKNESS REQUIRED 23.9 12" MIN. INT. DIM. 4" OSCH40 PVC INSTALL TEE PIPES LEVEL 1ST 2' U 10" 1500 GAL H-10 14" TEE SEPTIC TANK TEE 22,60' GAS BAFFLE 4' ENDS Fn `fri `Yri `Fri J° . WATERTEST D'BOX 0000b ;ooFOR LEVELNESS Ci ;oa 00100 �0�0� E= E 000a ``7��� 0 0 0..0.. �. :-O-O-O , 4' LIQ. LEVEL (ACME OR EQUAL) 21.47 1.30 ;�0�0�0�0 00000000 19.2 p000000000000000000000000000000^000000000p 1 L 1o„o_o_o_o_o.0 0 0 0 0 0 _n_9.0 0 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. H-10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. ALL AROUND PRECAST STRUCTURES (2) UNITS REQUIRED 6" CRUSHED STONE OR. MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [2]) Uil ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM 25' BLOCKS OR PRECAST RISERS MORTAR ALL H-10 COMPONENTS INV'S EL. 21.2 (TYP.) a� a®ao- 000a 000a a�ooa0000�o ���o ooaaa0000aa SIDE 22.03' 0 0 (_L2 % SLOPE) FOUNDATION 19' — LEGEND- EGEND99— 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[99}— PROPOSED CONTOUR 198•41 PROPOSED SPOT EL. TH1 TEST HOLE ZYY� SLOPE OF GROUND UTILITY POLE c FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS. ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: PHIL RENAUD DATE: 5-1-2019 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS Q ELEV. 1 0" 25.1 ' A LS 18" 10YR 4/2 B LS 36" 10YR 5/6 221' C PERC MS 1OYR 7/4 132" I 114.1' NO GROUNDWATER ENCOUNTERED LICE #' 9-092 (-2-8% SLOPE) (-!—% SLOPE) SEPTIC TANK 4' D' BOX 12' — *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM r W W r/ X W z W U Scale:1 "= 20' 0 10 20 30 40 50 FEET LEACHING FACILITY n 2 BEDROOM 0 KITCHEN I DINING 0 ROOM LIVING ROOM 1 ST FLOOR 14.1' BOTTOM TH-1 NO GROUNDWATER FOUND D -i BEDROOMo BEDROOM 0 HALL STORAGE FLOOR PLAN NOT TO SCALE 2ND FLOOR DATE NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS SHALL BE AASHTO H -M. 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING'OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40' 4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND LOCUS MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & l! OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1"=2000'± 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 123 PARCEL 59 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (AREA OF MINIMAL FLOOD HAZARD) AS AND REMOVED OR PUMPED AND FILLED WITH CLEAN SHOWN ON COMMUNITY PANEL #25001CO578J SAND. DATED 7/16/2014 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED i DESIGN FLOW: 3 BEDROOMS @ 110' GPD = 330 GPD > USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 CB DH FND USE A 1500 GAL. SEPTIC TANK _ LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD C TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND > MA APPROVED DATE BOARD OF HEALTH Ynrmouth Health Department Nome Date SersT �F SS\ i.. TONAL E DANIEL A. OJALA, P.E., P.L.S. TITLE 5 SITE PLAN OF #24 CENTER STREET YARMOUTH PORT, MA PREPARED FOR JEANETTE SEVIGNY DATE: MAY 13, 2019 REV.: JULY 31, 2019 off 508-362-4541 I fax 508-362-9880 downcape.com dOW4 ct►pe engineerin j, MC. civil engineers /and surveyors 939 Main Street ( Rte 6A) YARMOU THPOR T MA 02675 19-092 SEVIGNY.DWG i i �c Z° Locus c /?!e 6A 0 0 .2 c r � 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND LOCUS MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & l! OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1"=2000'± 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 123 PARCEL 59 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (AREA OF MINIMAL FLOOD HAZARD) AS AND REMOVED OR PUMPED AND FILLED WITH CLEAN SHOWN ON COMMUNITY PANEL #25001CO578J SAND. DATED 7/16/2014 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED i DESIGN FLOW: 3 BEDROOMS @ 110' GPD = 330 GPD > USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 CB DH FND USE A 1500 GAL. SEPTIC TANK _ LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD C TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND > MA APPROVED DATE BOARD OF HEALTH Ynrmouth Health Department Nome Date SersT �F SS\ i.. TONAL E DANIEL A. OJALA, P.E., P.L.S. TITLE 5 SITE PLAN OF #24 CENTER STREET YARMOUTH PORT, MA PREPARED FOR JEANETTE SEVIGNY DATE: MAY 13, 2019 REV.: JULY 31, 2019 off 508-362-4541 I fax 508-362-9880 downcape.com dOW4 ct►pe engineerin j, MC. civil engineers /and surveyors 939 Main Street ( Rte 6A) YARMOU THPOR T MA 02675 19-092 SEVIGNY.DWG