HomeMy WebLinkAboutReview Checlist ✓/e / TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. %40 Lot -y¢ Zone of Contribution: In OutL-Acreage
- �,A Commercial: Residential:
Street: -3 / 7' i/w �� f
Village: G' Floor Plan: #Bedrooms: 2 f
Owner: fit ptS Installer: £ *' 11
Address: Phone: I !/
Phone:
Builder: Engineer: / r
L�
Address: Phone: - 1 - . II_
Phone: � K;4 `f.. $ 2 .A ;j WU
/�� N/A YES NO
-
1.Required# of copies received
2.Date of soils exam and percolation test not older than 2 years C/
3. 4-5 ft of naturally occurring pervious material, above water table l/
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: t1•
5.Water line 10 ft from septic components Var.: L.--**
6.Benchmark indicated and shown-NGVD if near wetlands L-----
7.
/7. Septic tank minimum 10 ft from foundation, deck Var.: t/
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: -76,( ✓
9.Leaching minimum 100 ft from wetlands Var.: . C----'
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ..-------
11.
.--/11.Tank/leaching minimum 10 ft from property line Var.: L/--
12. System meets all other setback requirements Var.: L.�-'
13.Uses adjustment for maximum high groundwater Var.: •......------
14.
.-f14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: (.-----
15.
,_--
15. System not in top or subsoil(A,B horizons)or 5'removal u
16.Proposed contours are suitable c_----'
17. System meets slope requirements-min. 1/8", 1/4"preferred L_.
18. System meets breakout requirements PVC liner: Wall: t�--•
19. Specified tee sizes are proper, gas baffle on outlet tee Lam/
20. Sewage is under 10,000 gpd for parcel �✓
21.No garbage disposal L.------*
22. System adequately sized for its intended use \-!
23.Minimum 6"stone or compacted below tank and dbox �.-----•
• 24.Manhole covers within 6"of grade,pump chamber cover to grade `.---,
25.Inspection port on plastic chambers/leach field L✓-'
26.Electrical permit for pump chamber/Separate meter for duplexes ` ----
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size _=
28. Septic tank/pump chamber to be factory waterproofed 1/4..1
29.Vent provided if leaching below 3 feet,under driveway/parking •....__.-
30.Buoyancy calculations for tank/pump chamber �_.--.
31.Engineer to inspect and certify soils: wall: commercial: ,
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic, groundwater
34.Title V Application and permit fee, installer signature - L1
35.Foundation footing min. 2 feet above adjusted ground water for new house `-/`
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Ma -.------°
Plan reviewed by: 6/03103