HomeMy WebLinkAboutReview Checklist (61 )/7/1
' )/ / TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. q/ Lot 66 Zone of Contribution: In Out Acreage
Commercial: Residential: ✓ :
Street: 57 /..-.72,tie; .:4esi,cefilki--
Village: ,ie/ Floor Plan: ✓ #Bedrooms:
Owner: 76r Installer: '4/ '0'' /4eJ
Address: Phone: / - 77• C'-7/
Phone:
Builder: Engineer: Lir /G
Address: Phone: gerg 4:0.4' ? 7
./ -
Phone: 14:6 4�
`-c ; / mo eA
N/A YES NO
1.Required#of copies received tom
2.Date of soils exam and percolation test not older than 2 years c----''
3.4-5 ft of naturally occurring pervious material, above water table t--�'
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: s-----
5.Water line 10 ft from septic components Var.: V,.-----
6.Benchmark indicated and shown-NGVD if near wetlands �----
7. Septic tank minimum 10 ft from foundation, deck Var.: ‘..---
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.: 4._.-----
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: L./'
11.Tank/leaching minimum 10 ft from property line Var.: L�
12. System meets all other setback requirements Var.: .._.-----
13.
____�13.Uses adjustment for maximum high groundwater Var.: �..�
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: _....---
15. System not in top or subsoil(A,B horizons)or 5'removal �--
16.Proposed contours are suitable �_-..--"
17. System meets slope requirements-min. 1/8", 'A"preferred 1.-----
18.
.`18. System meets breakout requirements PVC liner: Wall: L----
19. Specified tee sizes are proper,gas baffle on outlet tee `_,
20. Sewage is under 10,000 gpd for parcel ....--
21.No garbage disposal r
22. System adequately sized for its intended use L'-
23.Minimum 6"stone or compacted below tank and dbox L----
24.Manhole covers within 6"of grade,pump chamber cover to grade 1/
25.Inspection port on plastic chambers/leach field 1/4..---
26.Electrical permit for pump chamber/Separate meter for duplexes -----'
27.Pump system-2"line,weep hole,check valve,tee in dbox, pump size .-----""
28. Septic tank/pump chamber to be factory waterproofed io"
29.Vent provided if leaching below 3 feet,under driveway/parking ,..--------
30.Buoyancy calculations for tank/pump chamber _,/
31.Engineer to inspect and certify soils: wall: commercial: ..-----
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature ./-
33.H-20 loading is subject to vehicular traffic, groundwater
34.Title V Application and permit fee, installer signature
35.Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37.Check area lots for groundwater/Label groundwater in Assessor's Mai
Plan reviewed by: e' 6/03ro3