HomeMy WebLinkAboutReview Checklist ,;,.--vim_, %W
TOWN OF,YARNIOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. '1? Lot zZ J Zone of Contribution: In Out Acreage
Commercial: Residential:
Street: eb 6 .4r1C ca
Village: Lbif GLGLii/7i2 Floor Plan: v #Bedrooms: . 4.
Owner: A����-r.( 70i1..1_1--(2 Installer:
Address: Phone: -7 78- I
Phone:
Builder: Engineer: be",,1 .
Address: 7 , Phone: fJ
Phone:
N/A YES / NO
1.Required#of copies received i/
2.Date of soils exam and percolation test notolder than 2 years : , ; . - .
3. 4-5 ft of naturally occurring pervious material,.above water table
4.Foundation 2 ft above high point of road .1-1.P.:` - Fnd: Var.: jy� . .
5. RFater line 10 ftfrom septic components Var.. t
6.Benchmark indicated and shown-NGVD if near wetlands , . .
7. Septic tank minimum 10 ft from foundation,deck Var.: „,„,,,,,„.„,ir
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var
9.Leaching minimum 100 ft from wetlands Var.:;
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: L-
11. Tank/leaching minimum 1.0 ft from property line . Var.: .., )...../".",
12. System meets all other setback requirements Var.: -
13.Uses adjustment for maximum high groundwater Var.:
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: -.: < l/"• ,
15. System not in top or subsoil(A,B horizons)or 5'removal
16.Proposed contoursare suitable
17. System meets slope requirements,min. 1/8", 14"preferred t,/'�. . -
18. System meets breakout requirements PVC liner: ,Wall: ��
19. Specified tee sizes are proper,gas baffle on outlet tee
2• 0. Sewage is under,10,000 gpd for parcel
21.No garbage disposal
22. System adequately sized for its intended usea �,
23.Minimum 6"stone or compacted below tank and dbox-., /.: t - -=
25.Inspection port on plastic chambers/leach field
24.Manhole covers within 6"of de chamber cover to grade
26.Electrical permit for pump. chamber/Separate meter for.duplexes, . m ' ::,7:
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size (
.
28. Septic tank/pump chamberto be factory waterproofed ,
29.Vent provided if leaching below 3 feet, under driveway/parking. (.4
30. Buoyancy calculationsfor tank/pump chamber
31. Engineer to inspect and certify soils: wall: , ..commercial;
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33. 11-20 loading is subject to vehicular traffic, groundwater t/
34. Title V Application and permit fee, installer signature
35.Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max, #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
„c......,/
Plan reviewed by: 6/03/03