HomeMy WebLinkAboutReview Checklist C-- i`/9 TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
- Location: A.M./3 Lot 7 Zone of Contribution: In Out c-------Acreage
Street:5c �/�° / ', Commercial: Residential:
v"��el /k j �
Village:
StreePlan: ( #Bedrooms: 3 / Ade"(
Owner: Cis' S Installer: /P i r C ��
Address: Phone: .s7,9- T/ 7-- 2
Phone: frC , / �
Builder: 7VEngineer: �Q f G�c
Address: Phone: d �� €771 9
Phone: f�� < �4°4
/
N/A NO
1.Required#of copies received C..--'
2.Date of soils exam and percolation test not older than 2 years
L.----
3.4-5 ft of naturally occurring pervious material, above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ,_.--
5.Water line 10 ft from septic components Var.: l____--
6.Benchmark indicated and shown-NGVD if near wetlands t_
7. Septic tank minimum 10 ft from foundation, deck Var.: (....-----
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: L
9.Leaching minimum 100 ft from wetlands Var.: `--..--'
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: L.-----
11.Tank/leaching minimum 10 ft from property line Var.: L----
12. System meets all other setback requirements Var.: _ c....-----
13.Uses adjustment for maximum high groundwater Var.: ,....__
14.Leaching set 4-5 ft above adj.water or bottom . -- .._ - Var.: L..----'
15. System not in top or subsoil(A,B horizons) . 5' remova 1/4.......---
16.
e16.Proposed contours are suitable ._--
17. System meets slope requirements-min. 1/8", 1/4"preferred c.o--
18. System meets breakout requirements PVC liner: Wall: (..-----
19. Specified tee sizes are proper, gas baffle on outlet tee .�_
20. Sewage is under 10,000 gpd for parcel ‘....._____.-
21.No garbage disposal 1/4----
22. System adequately sized for its intended use 4...-----
23.
..�23.Minimum 6"stone or compacted below tank and dbox L____--.
24.Manhole covers within 6"of grade,pump chamber cover to grade ( ----*
25.Inspection port on plastic chambers/leach field l----•
26.Electrical permit for pump chamber/Separate meter for duplexes .---••-'
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size �.---•
28. Septic tank/pump chamber to be factory waterproofed ....-..--
29.
_-29.Vent provided if leaching below 3 feet,under driveway/parking ..._._..-
30.
130.Buoyancy calculations for tank/pump chamber
31.Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature .....--•
33.H-20 loading is subject to vehicular traffic, groundwater 1/4.-----
34.
,r-
34.Title V Application and permit fee, installer signature - L_--./
35.Foundation footing min.2 feet above adjusted ground water for new house -----"
36.Deed Restriction required max. #bedrooms: max. flow: gpd c------''
37.Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: ( 6/03/03