Loading...
HomeMy WebLinkAboutReview Checklist " I TOWN OF YARMOUTH 71,4' _ / SEWAGE PLAN REVIEW CHECKLIST /�C- q Aealt-i Location: A.M. I'y Lot Zone of Contribution: In_✓Out Acreage /S//� - P Commercial: Restial Street: ....)1 Moor �/� 4 (4iVillage: Floor Plan: C.D____ edrooms: Jil Owner: if/tiee 7 (CS it(t-'f"/ ' Installer: N-n ckvia Address: ikr:0 I Phone: 5-1k-6 i,/ - 97 j Phone: Builder: Engineer: �PtceC// a7A Address: 7 Phone: Irioi7g_-';z2erajekeipti. 7-5J g/ /!Phone: N/A YES NO 1.Required#of copies received ✓ 2. Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring pervious material, above water table t.....---- 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: L.--✓ 6.Benchmark indicated and shown-NGVD if near wetlands 1----- 7. Septic tank minimum 10 ft from foundation, deck Var.: k...--- 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: (/ 9.Leaching minimum 100 ft from wetlands Var.: `-- 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: t.---- 12. .r12. System meets all other setback requirements Var.: 1...---- 13. 13.Uses adjustment for maximum high groundwater Var.: k......----- 14. /14.Leaching set 4-5 ft above adj.water or bottom oVar.: t� 15. System not in top or subsoil(A,B horizons) 5'remov 16.Proposed contours are suitable l.o--- 17. System meets slope requirements-min. 1/8", '/4"preferred L----- 18. om/18. System meets breakout requirements PVC liner: Wall: /./ 19. Specified tee sizes are proper, gas baffle on outlet tee C/ 20. Sewage is under 10,000 gpd for parcel t_----' 21.No garbage disposal L/ _ 22. System adequately sized for its intended use t..----' 23.Minimum 6"stone or compacted below tank and dbox (------- 24.Manhole covers within 6"of grade,pump chamber cover to grade ,...----- 25. 125.Inspection port on plastic chambers/leach field t....--- 26. _i26.Electrical permit for pump chamber/Separate meter for duplexes c..-- 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size ,.....--- 28. Septic tank/pump chamber to be factory waterproofed ,...------ 29. f29.Vent provided if leaching below 3 feet,under driveway/parking -/' 30.Buoyancy calculations for tank/pump chamber (.....---- 31. !31.Engineer to inspect and certify soils: wall: commercial: c..------ 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature %_------- 33.H-20 loading is subject to vehicular traffic, groundwater . ----' 34.Title V Application and permit fee, installer signature - moo' 35.Foundation footing min.2 feet above adjusted ground water for new house _.----- 36. .---o36.Deed Restriction required max. #bedrooms: max. flow: gpd .- 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: wosios