Loading...
HomeMy WebLinkAboutReview Checklist 7- f 4.--. q TOWN OF YARMOUTH SEWAGE EE PLAN REVIEW CHECKLIST Location: A.M. z3 Lot 7 J Zone of Contribution: In Out"-A reage Commercial: Residential: Street: Village: �ff� Floor Plan: AO #Bedrooms: Owner: 401 s 0- Installer: L+-"CCa 4%2r Address: Phone: �j O. - ¢7 QG S- Phone: 77,, , mem,_,..ww,-......, Builder: Engineer: ,AG2/7o' Address: Phone: / 7 71 -- 9,91 //��j .ZV Phone: (.0 yt a/' �� �`r/ t V /A YES NO 4 Af 4/S ./21.Required#of copies received c.,...------ 2. .Date of soils exam and percolation test not older than 2 years L___-- 3.4-5 _r3.4-5 ft of naturally occurring pervious material,above water table L.---• 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: Gv 6.Benchmark indicated and shown-NGVD if near wetlands ,t/ 7. Septic tank minimum 10 ft from foundation, deck Var.: ti� 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: k._........-- 9. ._..`9.Leaching minimum 100 ft from wetlands Var.: ,..---- 10. 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: 5 12. System meets all other setback requirements Var.: t------ 13. ----s13.Uses adjustment for maximum high groundwater Var.: t..------ 14. t14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: �--"' 15. System not in top or subsoil(A,B horizons)or 5'removal L---• 16.Proposed contours are suitable t_.1 17. System meets slope requirements-min. 1/8", '/a"preferred c----- 18. System meets breakout requirements PVC liner: W .Wall: L.-----"' 19. Specified tee sizes are proper, gas baffle on outlet tee L----' 20. Sewage is under 10,000 gpd for parcel �s 21.No garbage disposal c.....----- 22. .122. System adequately sized for its intended use L-----# 23.Minimum 6"stone or compacted below tank and dbox 4.-�' 24.Manhole covers within 6"of grade,pump chamber cover to grade 25.Inspection port on plastic chambers/leach field L..--• 26.Electrical permit for pump chamber/Separate meter for duplexes .-.....----- 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet,under driveway/parking ----' 30. Buoyancy calculations for tank/pump chamber �---- 31.Engineer to inspect and certify soils: wall: commercial: �--w 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee, installer signature _ 35.Foundation footing min. 2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37.Check area lots fcir groundwater/Label groundwater in Assessor's Map Plan reviewed by: 6/03/03