HomeMy WebLinkAboutEngineered Plan - 2019NKEY: 4 EXISTING CONTOUR: — — — — PROPOSED CONTOUR: --•••••-- ... EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: * UTILITY POLE: -0- FENCE LINE: HYDRANT: -b-- RETAINING WALL. r LOCUS LOCATION MAP LOT (28,000 SF) ASSESSORS MAP: 49 PARCEL: 216 PLAN BOOK: 270, PAGE: 64 N 5,�oc .' F� REPLACE EXISTING 1000 GALLON SEPTIC TANK WITH NEW 1500 GALLON TANK M19-27 ZOM LEACH AREA DETAIL SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC TANK: 330 GAL / DAY x 2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 2 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (25' x 12.8' x 2' EFF. DEPTH) SIDE AREA: (25' + 12.8') x 2 x 2 = 151 SF (0.74) = 112 GAL/DAY BOTTOM AREA: 25'x 12.8'= 320 SF (0.74) = 237 GAL/DAY CAPACITY = 349 GAL/DAY 31d, R 00 ;1' �a,�� i V BENCHMARK AT LEFT CORNER OF BOTTOM STEP ELEVATION = 102,45 SEPTIC SYSTEM SECTION COVERS WITHIN 6" OF FINISHED GRADE TOP OF FOUNDATION ELEV. 1500 GAL SEPTIC TANK (6" OF STONE UNDER OR MECHANICALLY COMPACTED) TEE SIZES: (TO BE CONFIRMED) INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN bath ROOM a BED ROOM BED opten ROOM below 2nd FLOOR 1st FLOOR EXISTING FLOOR PLAN 1/4" per ft (1' MIP ?.$ 71 1T 1/4" per ft D -BOX 6" OF STONE UNDER OR MECHANICALLY COMPACTED) ELEV. -GAS BAFFLE AT OUTLET TEE PEASTONE OR FILTER FABRIC 3/4" - 1 1/2" DOUBLE WASHED STONE --INSPECTION PORT ELEV.= 98.39 I I I ° ° ° ' ° ° ° ° 1.11 1 95.56 4 <—> ELEV. —25'x 12.8' 2 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' EFF. DEPTH) 132" 1 1 90.0 NO GROUND WATER ENCOUNTERED (MARSH ELEVATION = 83.4) NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. _ 3. SCHEDULE 40 - 4! -KC PIPE TO BE USED THROUGHOUT SEPTIC_SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL, 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA, 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PRE THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES OT N REPRESENT A FULL DETAILED PROPERTY SURVEY. ED 13. EXISTING LEACH PIT IS TO BE PUMPED AND FILLED WITH SAND OR R OVEEL ,U 2U y 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FL W. HEALTH DEPT SITE PLAN LOCATION: 25 MUSCOVY IN., W. YARMOUTH, MA PREPARED FOR: PAMELA GIARD DATE: 5-31-19 SCALE: I"= 30' ' BASS RIVER ENGINEERING THOMAS J. McLELI�4fN, P.E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048 TH-1 101.0 12" TEST HOLE LOGS FILL ELEV. AHORIZON ENGINEER: THOMAS McLELLAN, RE, 24" LOAMY SAND 10YR 3/4 q3,0 WITNESS: AMY VON HONE, R.S. B HORIZON DATE: 5-30-19 PERCOLATION RATE: < 2 MIN/IN 38" LOAMY SAND 10YR 5/8 97.8C HORIZON FINE SAND 2.5Y 7/4 PERC AT 54" 132" 1 1 90.0 NO GROUND WATER ENCOUNTERED (MARSH ELEVATION = 83.4) NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. _ 3. SCHEDULE 40 - 4! -KC PIPE TO BE USED THROUGHOUT SEPTIC_SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL, 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA, 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PRE THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES OT N REPRESENT A FULL DETAILED PROPERTY SURVEY. ED 13. EXISTING LEACH PIT IS TO BE PUMPED AND FILLED WITH SAND OR R OVEEL ,U 2U y 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FL W. HEALTH DEPT SITE PLAN LOCATION: 25 MUSCOVY IN., W. YARMOUTH, MA PREPARED FOR: PAMELA GIARD DATE: 5-31-19 SCALE: I"= 30' ' BASS RIVER ENGINEERING THOMAS J. McLELI�4fN, P.E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048