Loading...
HomeMy WebLinkAbout2019 Aug 12 - Sign Off Transmittal, Plan - Inground Swimming Pool RECEIVED TOWN OF YARMOUTH Ate 1 ?2019 ,c HEALTH DEPARTMENT o �-''� HEALTH DEPT. PERMIT APPLICATION SIGN OFF TRANSMITTAL SHEET To be completed by Applicant: Building Site Location: !? Nor-E-11 dOtivt9f,'i C(/1Q JariiuApor4 Proposed Improvement: hyoUrtel Stu,'mmt J Pool Applicant: 8e.„11&., Poo t c Tel. No.: SP'39g-- 077 Address: 5a1LOkif-e5 ecith jgb til QOM QtyDa Filed. (a 1"/ **Ifyou would like e-mail notification ofsign off please provide e-mail address: / /.z.-rd . eafe 1j_?,1,I Qr& c J'Aitl^ t .1-s n 4- Owner Name: C-7 ii n K—I 1(A K Owner Address: Ea d°Lk-51)Y1 bhv ltt-54-0-A A ?Y1t" Ol��lp SbF-3O8- `7(ti(0 �� Owner Tel. No.: 16i N 0 --4-tS cuvvc1 Si-AL L t t \)a-rm o u ma4- 0)._to 15- RESIDENTIAL SRESIDENTIAL AND/OR COMMERCIAL BUILDING HEALTH DEPARTMENT: Determines Compliance to State and Town Regulations; i.e., Requirements For Septage Disposal and other Public Health Activities. Please submit three (3) copies of plans, to include: (1.) Site Plan showing existing buildings, water line location, and septic system location; (2.) Floor plan labeling ALL rooms within building (all existing and proposed)— Note:Floor plans not required for decks,sheds, windows, roofing; (3.) If necessary, Title 5 application signed by licensed installer with fee. REVIEWED BY: ' DATE: /1 PLEASE NOTE COMMENTS/CONDITIONS: r1 ICE REQUEST: A VARIANCE TOINSTALL AN SAS GREATER THAN 3 FEET ME. A VENT AND CHARCOAL FILTER HAVE SEEN PROVIDED N/F BANK OF BOSTON Permit valid for :PAIR ()h SEPTIC' SVS'fl•M Is ONLY, flue to Stat, and f anal sclNic variances., k0 Board. of lleallh reci(- and :11qr1+ %al 1\ require�f8+ 0' ary fulure additi-1 Jre�++a :ulouti:llteratfjll}J: A 5A sewagelaeilities and,'or s ria u, cshlltrllln . N armouth IleaIla I)V.. r t�tettt AYt'R(' LD /.4 ECT BENCH MARK OF FOUNDATION = 100.00 (ASSt LOT #7A (/,W ✓ f " ;7 CVw `t PATIO oma N/F OLD;COLON) W N 0 t°o 1 LOT #sD 'i � GRAVEi.� \ GRAVEL DRIVEWAY / \ \ ` , DRIVEWAY SSS --I-, . 98 00� AA 14 00 1. Contractor is responsible for Digsafe notification, Verification of Ut-111ties and protection of all underground utilities and pipes. 2. The septic"tank a l distribution box shall be set level on 6 of 34 —1 1/2" stone. ys 3. Backfill should be clean sand or gravel with no stones over 3" in size. 4. This system is subject to inspection during installation by Shay Environmental Services 5. The contractor shall install this system in accordance with Title V of the Massachusetts state code, the approved plan / and Local Regulations. 6. If, during installation the contractor encounters any 0!.9fsoil conditions or site conditions that are different from those shown on the soil log or in our design gkp. installation must halt & immediate notification be made to Shay Environmental Services 7. No vehicle or heavy machinery shall drive over the septic system unless noted as H-20 septic components. 8. Install Tuf—Tate gas baffles or equals on all outlet tee ends. 9. All Distribution Lines shall be 4" diameter Schedule 40 NSF PVC pipes. 10. All solid piping, tees & fittings shall be 4" diameter 1 AUG 12 2019 POC C' HEALTH DEPT. Schedule 40 NSF PVC pipes with water tight joints. 11. Municipal Water is Connected to ALL OF The Abutting Properties Within 150 Feet. THE PROPERTY LINES ARE APPROXIMATE AND COMPILED FROM THE SURVEY PLAN BY SURVEYING/ENGINEERING CONSUTAP ENTITLED: "PLAN OF LAND OF LOT 6D N SANDYSIDE LANE YARMOUTH, MA DATED: JAN 17 2002 AND IS NOT INTENDED TO BE A SURVEY PLOT PLAN XV67ZNc' / /y 0 20 40 50 IT SHOULD BE USED FOR NO iPURPOSE OTHER THAN 3 JWDXOOAf auasa // THE SEPTIC SYSTEM INSTALLATION. fuU foundation / EXISTING LEACH PIT TO BE PUMPED OUT AND FILLED IN PLACE NOTE: ANY STRIPPED OUT SOIL CONTAINING LEACHATE SCALE: 1 "=30' FROM THE. EXISTING CESSPOOL/LEACH PIT TO BE DISPOSED OF AS PER BOARD OF HEALTH SPECIFICATIONS. / REVISED OCT. 12, 2015 — Per Board OF HEALTH CORRESPONDENCE ED I EXIST. g s� Tunk 76 v 3f TEST HOLE #1 ELEV.- 98.50 /Y"CCBDD.H. Y VENT PIPE l'.8 PORT f / / t'a F w/CHARCOAL FILTER / /' GARAGE / Ile �� y 0 L.g4.3y • , i p0. CB D.H. cern First Floor Kkchen I pmk,y J , Bedroom ® 19 N Sw*vIde Ln J 3D ± L LOCUS MAP PLOT PLA N OF PROPOSED SEPTIC SYSTEM UPGRADE 6 Second Floor - DESCRIPTION BY OWNER Bedroom Both Bedroom 1 4 ZOISit Q PREPARED FOR ln RALPH ALBERTI AT. NORTH SAN DYS I D E LANE ASSESSORS MAP 122 PACEL.#1 YARMOUTH, MA PREPARED BY: 3 I 3 j +��4RMEN E. SHAY ENVIRONMENTAL SERVICES P.O. Box 1576 MASHPEE, MA 02649 TEL/FAX : 508-294-7498 SCALE: 1"=30' DRAWN BY: CES DATE: SEPT 25, 20015 PROJECT#19 N SANDY FILENAME: 19 N SaNDY.DWG SHEET 1 OF Ween=J�