Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH - // SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Y 0 Lot _2/3Zone of Contribution: In Out"Acreage • Commercial: Residential: Street (D/� 1 �� ,''� / Village: di/ Floor Plan: ✓ #Bedrooms: Owner: /'U(1/ '/67� Installer: t/ 4 j �f Address: C�GG� Phone: 5 - 7 -- 9 ,7-y Phone: Builder: Engineer: 4i��G1 Address: Phone: 0 - -- ,/ Phone: --1 iy,"� 7G E j=d. N/A YES NO _ 1.Required#of copies received (/ 2. Date of soils exam and percolation test not older than 2 years (...---- 3.4-5 ft of naturally occurring pervious material, above water table d,�- 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: c_......----- 5. Water line 10 ft from septic components Var.: �_----- 6.Benchmark indicated and shown-NGVD if near wetlands t/= 7. Septic tank minimum 10 ft from foundation, deck Var.: L _ -----. 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: t...------- 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: �� 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: s:.---- 14. ✓14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: ,..---- 15. System not in top or subsoil(A,B horizons)or 5' removal �.----- 16.Proposed contours are suitable L� 17. System meets slope requirements-min. 1/8", 1/4"preferred L.----- 18. System meets breakout requirements PVC liner: Wall: Lam• 19. Specified tee sizes are proper, gas baffle on outlet tee ‘.......-- 20. .120. Sewage is under 10,000 gpd for parcel 21.No garbage disposal L----v 22. System adequately sized for its intended use L__.. -23.Minimum 6"stone or compacted below tank and dbox L� 24.Manhole covers within 6"of grade,pump chamber cover to grade L_,� 25.Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes `-----' 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size -------# 28. Septic tank/pump chamber to be factory waterproofed -S 29.Vent provided if leaching below 3 feet,under driveway/parking --- ' 30.Buoyancy calculations for tank/pump chamber �/` 31.Engineer to inspect and certify soils: wall: commercial: `..-- 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature �/' 33.H-20 loading is subject to vehicular traffic, groundwater �-=---A• 34. Title V Application and permit fee, installer signature - _ �--- 35.Foundation footing min. 2 feet above adjusted ground water for new house -� 36.Deed Restriction required max. #bedrooms: max.flow: gpd -� __/- 37.Check area lots for groundwater/Label groundwater in Assessor's M. • Plan reviewed by: A 6/03/03