Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutEngineered Plan - Rev. 1998N
CE,
ST.
0
LOCUS
SOUTH SHOgE y�
NANTUCKET
SOUND
LOCATION MAP
LOT 240
9,395 S.F.
(022 ± AC.)
ASSESSORS MAP: 29
PARCEL: N 240
FLOOD ZONE: C
BENCHMARK AT
WOOD STAKE
ELEVATION = 11.2
REQUIRED VARIANCES FROM TITLE FIVE:
1. SECTION 15212: LEACH AREA TO BE 4' ABOVE GROUNDWATER.
(SEPTIC SYSTEM HAS BEEN DESIGNED TO MAXIMUM FEASIBLE COMPLIANCE)
100. pOH
,111,
TH-1cp
, 1
S 1 1
T',
i ,yl
I PC
In A _� f0
MIN
EXISTIN
EXISTING INVERT =
INVERT = 89
cn
�I'
w �
co
I
11 FENCE
0.0
A HORIZON
MIN
LOAMY SAND
lot
6"
MIN
'IFI i
- +10.2
si
f0' YIN
'
10YR 5/8
NI
EXISTING
Cl HORIZON
B67 INVERT -7B6
w
MEDIUM SAND
EXISTING
3 BEDROOM I
DWELLING
1stlour - 10.9
(CRAWL SPACE)
CARPORT RIVE
f0
W
DAVED
CE /
100 00" ` J
/
9.4
PAY
i EorE OF
f0
STREET
CEDAR
KEY.
EXISTING CONTOUR: -
PROPOSED CONTOUR: • • • • • ............. • . • • ....... •
EXISTING SPOT ELEVATION: 25.5
PROPOSED SPOT ELEVATION: 25
TEST HOLE:
UTILITY POLE: -0-
FENCE LINE:
HYDRANT: -�
RETAINING WALL:
TREE:
DM # 98-Og7 (D29F19)
m!!
r
TEST 1-InL LO��.
ENGINEER:_ THOMAS McLELLA.N, P.E.
WITNESS: AMY VON HONE, R.S.
-------------------------------
DATE: 7-8-98
PERCOLATION RATE: < 2 MIN'
/IN
TH-1.
A HORIZON
ELEV.
LOAMY SAND
6"
IOYR 3/3
f0.8
B HORIZON
LOAMY SAND
26"
10YR 5/8
9.1
Cl HORIZON
MEDIUM SAND
48"
2.5Y 7/6
73
C2 HORIZON
FINE SAND
2.5Y 7/3
94" 3.5
96" 33
USGS GROUNDWATER ADJUSTMENT:
WELL: MIW-29, ZONE: A, ADJUSTMENT (JUNE): 0.7'
TH-2
SEPTIC SYSTEM DESIGN
FLOW ESTIMATE:
,i BEDROOMS AT 110 GAL/DAY/BEDROOM = 330 GAL/DAY
SEPTIC TANK.
330 CAL/DAY z 2 DAYS = 660 GAL
USE 1500 GALLON SEPTIC TANK
LEACHING AREA:
USE 5 INFILTRATORS (STANDARD CHAMBERS)
WITH 4' OF STONE AROUND SIDES AND 3' AT ENDS
(3725' x 1P x 7" DEEP)
SIDE AREA: (4825)2 x 7/12 = 56 (.74) = 41 GAL/DAY
BOTTOM AREA: 37.25 x 11 = 410 SF (74) = 303 GAL/DAY
CAPACITY = 344 GAL/DAY
SEPTIC SYSTEM SECTION
1 , 0_t L
i. VERTICt.L DATUM: _ASSUMED FRO2V Qj.'«'i
2. MUNIC'Al"AL `ATER IS AVAILABLE-.
3. SCIIF_ DUI.. 40 - 1" PVC PIPE TO BE U, r S
4, ALL PRECAST UNITS TO CONFORM 17IT I' AASH -10 H -J0
LOA UNG SPECIFICATIONS.
5. PIPE PITCH = -_118" & I 4" PER FOCI:'', ."N1 F';: 2v`%7 E C- :'i E RT'-IL'F, i.
6. FIRST 2' OF PIPE OUT OF D -BOX TO BT' SF,T LFII E .',.
7. THE SEPTIC SYSTEM HAS NOT BEEN D7.'S1G'`Fi_; TO Ai '70310D.'TF THE
USE OF A GARBAGE DISPOSAL.
8. ALL CONSTRUCTION DETAILS ARE TO BF IN C�-),V7OR.1vfAIAC'E r'IllH THE
STATE OF MASS. ENVIRONMENTAL COTE "TITLE FIL'F AND I:,OC,':L
HEALTH REGULATIONS.
9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES' PRIOR
TO CONSTRUCTION.
10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO
EXCEED 3.0'.
11. ALL UNSUITABLE SOIL (A & B HORIZON, APPROX. 26" 'DEEP) WITHIN 5' OF
PROPOSED LEACH AREA IS TO BE REMOVED AND REPLACED WITH CLEAN
MEDIUM SAND.
12. EXISTING CESS POOLS ARE TO BE PUMPED AND FILLED WITH SAND
OR REMOVED.
13. SEPTIC TANK AND PUMP CHAMBER ARE TO BE WATER PROOFED BY
MANUFACTURER WITH IPANEX CONCRETE ADDITIVE OR CONSEAL-55.
14. AN ELECTRIC PERMIT IS REQUIRED PRIOR TO PUMP INSTALLATION.
COVERS WITHIN 12" OF 2" PEASTONE
FINISHED GRADE COVER OVER PUMP TO BE
10.9 WITHIN 6" OF FINISH GRADE. 314" - 1 V2"
FIRST FLOOR 2" PCV (PRESSURE LINE) WASHED STONE
� ELEV. 9.3
77 /-
7.f
7.4 -� _
ELEV. 7.15 ELEV. DRAIN 897 D -BOX
2.6 m 82
2- �� 1500 G,� ELEV. ELEV ELEV. (6" OF ELEV. 3H ELEV.
ELEV. PUMP CHAMBER (1000 GAL) STONE F 3725'
SEPTIC TANK
(6" OF STONE UNDER OR) SEPTIC TANK WITH MYERS UNDER) 4•
-SRM-4 PUMP. PUMP ALARM (TEE AT INLET) 8.78 5 INFILTRATORS (STANDARD CHAMBERS
7.66, 8.9 & 9.67 MECHANICALLY COMPACTED) PACKAGE TO BE INSTALLED )
ELEV. IN DWELLING POWERED ELEV. WITH 4' OF STONEAROUND SIDES AND
(EXISTING) TEE SIZES: BY A CIRCUIT SEPARATE X AT ENDS (37.25' x 11' x 7" DEEP)
FROM THE PUMP
INLET: 6" UP, 13" DOWN POWER, (DISTANCE BETWEEN
OUTLET: 6" UP, 14" DOWN ON/OF SWITCH TO BE 4").
(GAS BAFFLE AT OUTLET TEE) AND ALARM TO BE 2-) N SWITCH ADJUSTED GROUNDWATER ELEV. 42 J
BOUYANCY FORCE = 5,975 LBS BOUYANCY FORCE = 4100 LBS
WEIGHT OF TANK=11,480LBS WEIGHT OF TANK = 8,240 LBS
�.- SITE AND SEWAGE PLAN
APP OVED BY: DATE:
DEMAREST-McLELLAN ENGINEERING
24 SCHOOL STREET P.O. BOX 463
WEST DENNIS, MASSACHUSETTS 02670
PHONE & FAX : (508) 398-7710
OF R4.
a TP" I ,AJ. s s9�y
lexxCC► ^^p�' gqee�llip r r g JOHN
�l
�" Edi U: ',..� "+ Z.
. .37s o DEMAREST, J4.
36859 71
FAQ
���ry
tit! Yn'� ''►'�rw� v �-'�
THOMAS McLELLAN, P.E. JOHN Z. DEMAREST JR., P.L.S.
LOCATION.•
40 CEDAR STREET
SOUTH YARMOUTH, MA
PREPARED FOR-
A. & B. CANCO/ALVES
SCALE: I"= 20' DATE: 712019
REFERENCE: PLAN BOOK 83 PAGE 127
REVISED: 7-31-98
nEcf�MG�L�
AUG 0 6 1998
HEALTH DEPT.