Loading...
HomeMy WebLinkAboutBLDE-19-006378 or , Commonwealth of Official Use Only Massachusetts Permit No. BLDE-19-006378 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:5/10/2019 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 23 WEST RD Owner or Tenant BUCKLEY THOMAS Telephone No. Owner's Address BUCKLEY MAUREEN,265 HARRIS AVE, NEEDHAM,MA 02492 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service 200 Amps 120/24( Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead ❑ Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Install a roof mounted photovoltaic system Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: STEVEN T BEEMAN Licensee: Steven T Beeman Signature LIC.NO.: 18155 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:217 STURBRIDGE RD,UNIT 46,CHARLTON MA 015075315 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 (1( /i9 � . .if 'Propriotary One.ntitl Infor mation. REVISIONS: cahootDisclosure Ml Bow SMrlum Solar U.0 IY prohibited* NO.I DATE I BY I ECN if 5X SUNPOWER SPR-X21-350-BLK-E-AC #12 THWN-2 EACH WITH 320W @ 240VAC,SINGLE PHASE MICROINVERTERS 2C+GND (NOT ALL MODULES ARE SHOWN) A HH H H CB1-L1 B I@ I it I 91 I i@ D < CB1-L2 STRING#10 GROUND 11X SUNPOWER SPR-X21-350-BLK-E-AC #10 THWN-2 EACH WITH 320W @ 240VAC,SINGLE PHASE MICROINVERTERS 2C+GND (NOT ALL MODULES ARE SHOWN) A a, L-, H H CB2-L1 D I rPpp I 1e 1 �@ D < CB2-L2 STRING#2 / GROUND RESIDENTIAL SOLAR PHOTOVOLTAIC INSTALLATION BUCKLEY, THOMAS &MAUREEN 23 WEST RD., S U N PO W E R. 17 JAN SEBASTIAN DRIVE,SUITE 12,SANDWICH,MA 02563 WEST YARMOUTH, MA 600 WEST CUMMINGS PARK,SUITE 4200,WOBURN,MA 01801 WEST YARMOUTH, MA 02673 RECORD LOW=-20 DEG C PHONE(781)281-8130,WWW.BLUESEL.COM by BlueSel Home Solar TOTAL SYSTEM SIZE: 5.6 KW-DC AVERAGE HIGH =26 DEG C DRAWN BY:OC I DATE:04-29-19 I SCALE:N/A I SHEET:1 OF I BORDER:C RECORD HIGH = 37 DEG C 5.12 KW-AC NAME: DWG NUMBER REV BUCKLEY,THOMAS&MAUREEN-23 WEST RD 05092-00 t "Proprietary and Comw.nnm Information. REVISIONS: DYcb.are•ItMot prior consent of Blue SoMMam Soler,LLC Y prohWt.d NO.I DATE I BY I ECN# NOTES: UTILITY 1.)IF POSSIBLE, RUN CAT-5 ETHERNET CABLE FROM CUSTOMER'S ROUTER TO INVERTER AND SOLAR NET METER PRODUCTION METER IF APPLICABLE. 2.)MOUNT METER SOCKET OUTSIDE WITHIN 10'OF UTILITY METER. SERVICE PANEL BREAKER 3.)MAKE UTILITY CONNECTIONS ON TOP AND SOLAR AT BOTTOM OF SMART METER SOCKET. BOX I I CONSUMPTION MONITORING CTs TO O ^ ^ SUNPOWER METER SOCKET SUPERVISOR #10 THWN-2 DEDICATED FOR #10 THWN-2 200A 2P / /0 • 3C+GND SMART PROGRAM METER EXTERNAL AC 3C+GND � DISCONNECT 0 • • 0 (30 AMP) 30A O • •• •• O LINE 1 LINE 1 (3 2P OJ• • O LINE 2 LINE 2 r.00 i ' O • • 0 I NEUTRAL NEUTRAL L --_------------------.-__J I I GND INTERNAL U L.-_-.J AC COMBINER GND PANEL SUNPOWER SOLAR ------------ AC PRODUCTION = MODULE CTs TO I O I SUPERVISOR SUNPOWER I SUPERVISOR 1 10A2P2P 15A 2P r• CB1-L1 —i OIO+--^OIO-�� CB1-L2 —1—0 O-"—►O 0---1 I I i 20A 2P 15A 2P CB2-L1 i 010-•--^OIO—^ I �—II - CB2-L2 —'-0, OHO 0—^ I I AC LIGHTNING I ARRESTOR GROUND RESIDENTIAL SOLAR PHOTOVOLTAIC INSTALLATION BUCKLEY, THOMAS& MAUREEN 23 WEST RD., S U N PO W E R. 17 JAN SEBASTIAN DRIVE,SUITE 12,SANDWICH,MA 02563 WEST YARMOUTH, MA 02673 600 WESPHO E(81)281-8130,WWWBL ESEL.COM�01801 by BlueSel Home Solar TOTAL SYSTEM SIZE: 5.6 KW-DC DRAWN BY:OC I DATE:04-29-19 I SCALE:WA I SHEET:2 OF 3 I BORDER:C 5.12 KW-AC NAME: D UMBER-REV BUCKLEY,THOMAS&MAUREEN-23 WEST RD t q w codla.nnol wa,noum. REVISIONS: Dbef n.Ithmo ,.lo.emwrn ofBlueSe Selenium Sow l� NO.I DATE I BY I ECN# NOTES: STRINGS TO COMBINER PANEL: STRING#1(5 PANELS) 1 CIRCUIT CURRENT CALCULATION -MAX CONT.OUTPUT CURRENT=1.33 AMPS/INV. -1.33 A X 5 AC MODULES=6.65 AMPS OVERCURRENT PROTECTION CALCULATION LL -6.65 X 1.25=8.31 AMPS 1 0 0 CONCLUSIONS 1 CL -USE 2 POLE 15 AMP CIRCUIT BREAKER -USE 12 AWG WIRE SIZE STRING#2(11 PANELS) 1 CIRCUIT CURRENT CALCULATION -MAX CONT.OUTPUT CURRENT=1.33 AMPS/INV. -1.33 A X 11 AC MODULES=14,63 AMPS OVERCURRENT PROTECTION CALCULATION -14.63 X 1.25=18.29 AMPS CONCLUSIONS -USE 2 POLE 20 AMP CIRCUIT BREAKER -USE 10 AWG WIRE SIZE L G 2 2 2 2 2 2 COMBINER PANEL TO GRID SERVICE: 0 TOTAL ARRAY AC CURRENT:21.33 AMPS 0 2 2 2 2 2 -USE 30 AMPS OVER-CURRENT PROTECTION -USE#10 AWG WIRE SIZE NOTE:NOTE:FOR WIRE RUN INSIDE THE HOUSE, NONMETALLIC SHEATHED CABLE ROOF 1 MAY BE SUBSTITUTED FOR THWN-2 IN CONDUIT RESIDENTIAL SOLAR PHOTOVOLTAIC INSTALLATION BUCKLEY,THOMAS &MAUREEN S U N POW R®23 WEST RD., 17 JAN SEBASTIAN DRIVE,SUITE 12,SANDWICH,MA 02563 WEST YARMOUTH, MA 02673 BOO WESPHOU E6(7INGS PARK,SUITE 4200,B)281-8130,WWW.BLUESEL.CCOM�01801 by BlueSel Home Solar TOTAL SYSTEM SIZE: 5.6 KW-DC DRAWN BY:OC I DATE:04-29-19 I SCALE:N/A I SHEET:3 OF I BORDER:C 5.12 KW-AC NAME: DWG NUMBER-REV BUCKLEY,THOMAS&MAUREEN-23 WEST RD 1 -tjo