HomeMy WebLinkAboutBLDE-20-000701 1 Official Use Only
y Commonwealth of
Permit No. BL - 00701
€ Massachusetts
BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked
[Rev.1/07]
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Elec.: al Code (MEC),527 CMR l;.0Q E 4 t V E D
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Dat` ":1%''''..i: ,
City or Town of: YARMOUTH To the Inspector o 'res: 8
By this application the undersigned gives notice of his or her intention to perform the electrical work described below. AUG - 2019
Location(Street&Number) 17 WILDWOOD PATH
Owner or Tenant DINATALE MARY A Telephone No. BUILDING DEPT
Owner's Address ROUSSELL P M&SPRY A D, 340 POND ST,WEYMOUTH, MA 02190-1330 py—
Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service 100 Amps 120/24( Volts Overhead 0 Undgrd 0 No.of Meters
New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of roof mounted photovoltaic solar systems,29 panels
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Data Wiring:
Heaters Signs Ballasts No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: 08/09/2019 Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee
provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such
coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: LLOYD R SMITH
Licensee: Lloyd R Smith Signature LIC.NO.: 15688
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address:30 1ST ST, MELROSE MA 021764010 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $150.00
Ctekiv cc> tel /9
�# 1800 W Ashton Blvd.
Lehi, UT 84043
Structural Group
J. Matthew Walsh, PE Samuel Brown, PE-Civil
Senior Structural Engineering Manager Structural Engineering
james.walsh@vivintsolar.com sam.brownr?a vivintsolar.com
July 03, 2019 I R E C E I V E_ k..1
r
Re: Structural Engineering Services j a
Yap Residence 1 AUG 2 1 1019
17 Wildwood Path,Yarmouth, MA �-_.. . ....,..�
S-6151416; MA-03 3 3 ,LDhNG DEPAR7MENT
To Whom It May Concern:
We have reviewed the following information regarding solar panel installation on the roof of the above referenced
home:
1. Site Visit by a representative from our office under my supervision identifying specific interior and
exterior site information including the condition of the existing roof system and the size, spacing, and
condition of existing structural framing members. Information gathered during the site visit includes
photographs,sketches, and verification forms.
2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to
the existing roof.
Based on the above information, we have evaluated the structural capacity of the existing roof system to support the
additional loads imposed by the solar panels and have the following comments related to our review and evaluation:
A. Description of Residence:
The existing residence is typical wood framing construction with a maximum of two layers of composite shingle
roofing. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir#2 or better with standard
construction components and consists of the following:
• Roof Sections (1 and 2): Dimensional lumber - 2x6 at 24" on center. Survey photos indicate that there
was free access to verify the framing size and spacing.
B. Loading Criteria
8.49 PSF= Dead Load (roofing/framing)
2.59 PSF= Dead Load (solar panels/mounting hardware)
11.08 PSF=Total Dead Load
20 PSF= Roof Live Load
30 PSF=Ground Snow Load (based on local requirements)
Wind speed of 140 mph (based on Exposure Category B-the total area subject to wind uplift is calculated for the
Interior, Edge, and Corner Zones of the dwelling.)
C.Solar Panel Anchorage
1. Installation shall proceed in accordance with the applicable guidelines and recommendations indicated below.
If, during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office
should be notified before proceeding with the installation.
• EcoFasten Solar Installation Manual, which can be found on the EcoFasten Solar website
(www.ecofastensolar.com).
2. The solar panels are 11/2' thick. At no time will the panels be mounted higher than 10" above the existing
surface of the roof.
Page 1 of 2 vi vint.
wtii
Page 2 of 2
3. The following mounting types shall be used. Please refer to the mounting details for the associated required
penetration depth. Based on our evaluation, the pullout demand is less than the maximum allowable per
connection and therefore is adequate.
• EcoFasten Solar: (1) 5/16" lag screw. Pullout capacity based on National Design Specifications (NDS)
of timber construction specifications for Spruce-Pine-Fir is 235 lbs/inch penetration.
4. Fasteners are installed to meet industry standards and this document satisfies requirements in 2015 IBC
2303.4.5 verifying that the fasteners will not adversely affect the roof framing.
5. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind
load uplift procedures of ASCE 7-10 and is specified below. These spacing requirements apply to all mount
types indicated above. The following values have been verified by in-house testing and the mounting hardware
manufacturers'data, which are available upon request. Panel support connections should be staggered, where
possible, to distribute load to adjacent members.
Modules in Landscape Modules in Portrait
Roof Zone Interior Edge Corner Interior Edge Corner
Max Vertical Spacing (in) 40 40 40 66 66 66
Max Horizontal Spacing (in) 48 48 48 48 48 48
Max Uplift Load (lbs) 205 166 155 346 279 261
D.Summary
Based on the above evaluation,with appropriate panel anchors being utilized the roof system designed on will
adequately support the additional loading imposed by the solar panels, if installed correctly. This evaluation has
been performed for the structural elements only and verifies that they are in conformance with the 2015 International
Residential Code with Massachusetts Amendments, current industry standards and practice, and the information
supplied to us at the time of this report.
If there are any questions regarding the above, or if more information is required, please contact me.
v(HofMgs
Regards, $!.•ffe ,N i �tiJ. MATTA �'J. Matthew Walsh, PE �/!
MA License No. 54057 ivILv y
NO. 54057
4:9
s/oNAL w-
07/03/2019