Loading...
HomeMy WebLinkAboutReview Checklist C c"---( �'j✓ TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST 1,./it?(. 6(,!EV Location: A.M. ‘?f Lot C/1 Zone of Contribution: In`-'I Acreage` 1V ?'/4- Commercial: Residential: Street: 2 c ,¢. Village: . ��r-- Floor Plan: C/ #Bedrooms: '47 - Owner: ( € )_ "47,1O Installer: 7,2 Address: Phone: _ ,4 /- Phone. Builder: 77Engineer: L- G 2 7-e.&-H Address: Phone: j2r �`if-- eT Phone: ._,991 v c Le,ye - �, / g;7 / N/A YES ..„NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years L_, 3.4-5 ft of naturally occurring pervious material, above water table �,.� 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: .t/ 6.Benchmark indicated and shown-NGVD if near wetlands i s 7. Septic tank minimum 10 ft from foundation, deck Var.: L1 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: L../ 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: dr.------- 11.Tank/leaching minimum 10 ft from property line Var.: ‘...---- 12. System meets all other setback requirements Var.: L---" 13.Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom o le Var.: l v 15. System not in top or subsoil(A,B horizons)o 5' remov �' 16.Proposed contours are suitable ,,- , , L----- 17. System meets slope requirements-min. 1/8", 1A" ,, eferred 18. System meets breakout requirements PVC liner: all: 19. Specified tee sizes are proper, gas baffle on outlet tee L`. 20. Sewage is under 10,000 gpd for parcel t.--- 21.No garbage disposal L_ -. 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox L 24.Manhole covers within 6"of grade,pump chamber cover to grade (....------ 25.Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes E-----" 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size L.----- 28. f28. Septic tank/pump chamber to be factory waterproofed e------* 29.Vent provided if leaching below 3 feet,under driveway/parking �� 30.Buoyancy calculations for tank/pump chamber 1/4.-----• 31.Engineer to inspect and certify soils: wall: commtial: kt N......----•32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature et-c qt4 33.H-20 loading is subject to vehicular traffic, groundwater Lam' 34.Title V Application and permit fee, installer signature 35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd _----------- 37.Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: 6/03/03