No preview available
HomeMy WebLinkAboutReview Checklist 7- -(9 TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. /2 Lot 5, Zone of Contribution: In Out VAcreage S ,� - Commercial: Residential: Street: 2( 6111)1'� 1$/�'v�� ��. Village: #-z! Floor Plan: #Bedrooms: 3 Owner: JtVitlif z��'/ [ S(cW,1? Installer: AS Address: Phone: COV-Se) -6.2- 7 Phone: l1AddBuilder: Engineer: 1)4-145- ress: Phone: ' qi)-e 1 - ,S ` Phone: N/A YES NO 1.Required#of copies received L/ 2.Date of soils exam and percolation test not older than 2 years k.----- 3.4-5 .-----3.4-5 ft of naturally occurring pervious material,above water table C1 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: c _-' 5.Water line 10 ft from septic components Vat: C1 6.Benchmark indicated and shown-NGVD if near wetlands L----' 7. Septic tank minimum 10 ft from foundation, deck Var.: c.------- 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: L.---- 9. 19.Leaching minimum 100 ft from wetlands Var.: �-•-- 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: - 12. System meets all other setback requirements Var.: 4,-- 13.Uses adjustment for maximum high groundwater Var.: ..-..---- 14. �14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: Cbz-'15. System not in top or subsoil(A,B horizons)or 5'removal ''��++ 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", 1 "preferred L------ 18. 118. System meets breakout requirements PVC liner: Wall: �� 19. Specified tee sizes are proper, gas baffle on outlet tee tys 20. Sewage is under 10,000 gpd for parcel C---• 21.No garbage disposal L1 22.System adequately sized for its intended use (� • 23.Minimum 6"stone or compacted below tank and dbox (/ 24.Manhole covers within 6"of grade,pump chamber cover to grade (/ 25.Inspection port on plastic chambers/leach field C1 26.Electrical permit for pump chamber/Separate meter for duplexes �--. 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size k.....---- 28. .128.Septic tank/pump chamber to be factory waterproofed t-----** 29.Vent provided if leaching below 3 feet,under driveway/parking �1 30.Buoyancy calculations for tank/pump chamber L1 31.Engineer to inspect and certify soils: wall: commercial: ✓ 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature _..---•"# 33.H-20 loading is subject to vehicular traffic, groundwater �...----• 34.Title V Application and permit fee, installer signature --•---" 35.Foundation footing min.2 feet above adjusted ground water for new house - -----* 36.Deed Restriction required max. #bedrooms: max. flow: gpd .--- -- 37.Check area lots for groundwater/Label groundwater in Assessor's Map '"'"-- Plan reviewed by: 6/03/03