Loading...
HomeMy WebLinkAboutReview Checklist r . F TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: AM 'IL(e) LOT '/ Date of Subdivision Approval Street .2( ? it 9 S 6,1�dN Zone of Contribution: In Ce Out Village a.),-1 ak--• Commercial Residential Owner: Ade ( 2 1 Installer C41,-/ -0 - Builder: / Engineer 267)c--- . N/A YES NO • 1.-Required number of co.ies received. L.------- 2. ,aeof �.'l e,,, t, . • ..: • • jot it.21 R. ode t • . - 3. 4 feet of naturally occurring pervious material, above water table(new constructions c� ` 4. Foundation 2 feetabove high point of fronting road for new construction. 5. Water availability letter from Water Department for new construction t.-----"' t_.,.� . . - IC..,._IIS 1 • .' •_.a I 0 it - 11. i Ifs Wq. -_ase 7. Building sewer does not exit center of house. `---•- 8. Septic tank a minimum of 10 feet from house and deck. ... -'--- 9. Leaching a minimum of 20 feet from house and 10 feet from deck. Li- 10. Leaching a minimum of 100 feet from wetlands. c.------ 11. Leaching,a minimum of 150 feet from drinking wells/25 feet from irrigation wells. ✓ 12. System meets all other setback requirements. t/ 13. Uses adjustment for maximum high groundwater. .....---- 14. Leaching 4-5 feet above adjusted water table or bottom of test pit. ‘....----- 15 System not in top or subsoil or 5 foot removal. t.� 16. Proposed contours are suitable. ....----- 17. System meets slope requirements-min. 118". 1/4" preferred. c----- 18. System meets breakout requirements- peastone elevation carried out 15 feet minimum. 19. Specified tee sizes are proper. gas baffle on outlet tee. ......----- 20. Sewage flow under 10.000 gpd for parcel. ,�-----" 1„ No garbage disposal. c..------ 2Z �2Z System adequately sized for its intended use: 1.----- 23. Minimum 6" stone or mechanically compacted below the tank and d-box. 24. Manhole covers within 6" of grade- septic tank and pump chamber. %...-- 25. Electrical permit for pump chamber. (....----• 26. Pump system- 2" line, weep hole. check valve, sanitary in d-box. alarm on separate circuit..--/ 27. Septic tank and pump chamber to be Factory watenroofed. (.../- 28. Vent provided if leaching below 3 feet or under driveway or parking. ._.----- 29. Engineer to inspect and certify : a. clay removal b wall cons ruction schedule c; commercial system •••••�� 30. Engineer and Land Surveyor stamp and signature. 31. H2O loading when system subject to vehicular trafficL.....--"1 32. Title V application and fee signed by a licensed installer 33. Foundation footing.2 feet above adjusted water table. 34. Lot subdivided prior to July 31. 1986 - Nitrate Loading, ../ 35. Subdivided p 'or co April 7. 1989 - Phosphorus Zone 300'. Plan reviewed by: h'