Loading...
HomeMy WebLinkAboutEngineered Plans - 2019rR� 2 Yarmouth Health Department /f P VED EXISTING CESSPOOLS ,lL TO BE PUMPED, FILLED Z�7 WITH SAND & ABANDONED Name Date TBM-1 COR./CONE. SLAB ( EL. =100.13 I x 94.8 /� ^� �P N 64'01'20" E -- - - � --- `IV i x 94,73 0 -- timber ret.' all 94,40 96 99.20 08 x SHED �6,\ TBM1/CDN 9 .44 98 x 100.13 x 9� 78,99 0 O � 99.98 61 n x z 99.96 N 0 0 p o I 99.5 99,6 ' LA / IN SEWER \ EXISTING HOUSE(#44) O.F.=101.2± TBM2/STEP 100.87 WALK 1� 100,13 x 00' 2'20" E AG. NAIL 99.29 98.70 LOWER BROOK ROAD PROPOSED SEPTI TANK INFILTR, TOR IM1530 X99. I I I 97.85 rt'� t- -to V 1 Irk ✓o O N � O 3 nd, 102.37 O 102,47 LOT 224 12, 375±S. F. + 9 9 i x 100.61 y � 99,x`0 0 00,37 CO �g V 99.61 y 499.00 cc� BASIN 98.44 TBM-2 COR./BOTT. STEP EL. =100.87 102,28 --100--EXISTING CONTOUR x 100.98 EXISTING SPOT GRADE 98 PROPOSED CONTOUR -W-EXISTING WATER SERVICE -G-EXISTING GAS SERVICE -$ H. W-- OVERHEAD WIRES 12 West Crossfield Road Forestdole, MA 02644 TEST PIT DATE BENCHMARK SHEET NO. LEGEND PROPOSED S.A.S. 28 ADS Arc 36 }AHD Units STONELESS 11.6' x 35' BED STRIPOUT BOUNDARY SEE NOTE 11 ��P��� OF MASSgCyo o PETER T. McENTEE v CIVIL No. 35109 "q, (e 1 � k'� OWNER OF RECORD CARIBBEAN REALTY, INC 7 ELM LANE MASHPEE, MA 02649 CAP( NOYES RD N BROOK RD WINDING Locus NLn 2 v BROOK RD Z FRESH r RD m RE � DP NG BROOK o� 9�o BEOOA RD } �o a ROAD ER 0 �OPpLo LOCUS 1p�yo WINS�ON GRAY PJB ROAD LOCUS MAP GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN MAP ID: 58-187 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 44 LOWER BROOK ROAD, SOUTH YARMOUTH, MA Prepared for: Caribbean Realty, Inc., 7 Elm Lane, Mashpee, MA 02649 Engineering by: Surveying by: SCALE DRAWN JOB. NO. Engineering Works, Inc. JC Engineering, Inc. 1 "=20' P.T.M. 196-19 12 West Crossfield Road Forestdole, MA 02644 2854 Cranberry Hwy. E.Wareham, MA 02538 DATE CHECKED SHEET NO. (508) 477-5313 (508) 273-0377 6/25/19 P.T.M. 1 Of 2 NOTE: TO' PREVENT BREAKOUT, THE PROPOSED PROPOSED SEPTIC TANK FINISH GRADE SHALL NOT BE < EL.=97.6 FOR A DISTANCE OF 15' AROUND THE ENCLOSED PORCH PROVIDE RISERS WITH APPROVED FRAMES & COVERS PERIMETER OF THE S.A.S. OVER EACH ACCESS MANHOLE AND SET TO FINISH GRADE. MANHOLES BROUGHT TO GRADE SHALL BE CL. SECURED TO PREVENT UNAUTHORIZED ACCESS. PROPOSED 0-BOX .PROPOSED S.A.S. INSTALL RISER & WATERTIGHT INSTALL 1 INSPECTION PORTS(MIN.) DIN. KIT. BATH BEDROOM (INFILTRATOR TW RISER SYSTEM OR EQUAL) COVER SET TO 6" OF GRADE ONE PER ROW IS RECOMMENDED T.O.F.=101.2± F.G. EL.=100.0±F.G. F.G. EL=99.9± EL.=98.9± to 100.0± F.G. EL.=98.8± � GARAGE CL � MAINTAIN 2% GRADE (MIN.) OVER S.A.S. LIV. RM. CL• BEDROOM 24" DIA. .±'p�n tA+� � n,n CL. L =1 1 , 24" DIA. ® S=l% (MIN.) TOP OF TANK=99.10 L = 30' 0S=1% (MIN.) L = 8' IN TWEOC (M N PORT ® S=l% (MIN.) ) 4"SCH40 PVC 24"DIA. COVER 4"SCH40 PVC 3,. o 4"SCH40 PVC FLOOR PLAN ----- INV.= - --1o„ I = - 14 98.50 44° LIQUID LEVEL e --- ---- - - I H1W 1H.I.M. 71NVE TO INV.=97.37 GAS BAFFLE PROPOSED INV.=97.20 4 ROWS OF 7 UNITS AT 5.0'/UNIT = 35' ENCLOSED BOTT.=94.56 INV.=98.25 D-BOX SOIL ABSORPTION SYSTEM (PROFILE) PORCH) ' �------31.6 ---�� PROPOSED 1500 GALLON SEPTIC TANK INFILTRATOR IM-1530 GALLON PLASTIC TANK INV.=97.10 20.0' --- SEWER CONNECT TO EXISTING SEWER AT HOUSE ESTABLISH VEGETATIVE COVER BACKFILL WITH CLEAN NATIVE OR EX. INV. =98.70± I /% r INV.=98.70± PERC SAND TO TOP OF CHAMBERS EXISTING �, ti O Is "�` NOTES: HOUSE(#44) p. 1) SEPTIC TANK, PUMP CHAMBER & D-BOX SHALL BE SET LEVEL & TRUE TO GRADE ON A MECHANICALLY COMPACTED BREAKOUT=TOP ; <,.' 1;.' TOP ELEV. =97.58 INV. ELEV.=97.10 GAA E �•0 F.=101.21 �/` 6 i M I L0 6" CRUSHED STONE BASE, PER 310 CMR 15.221(2). / 2) INSTALL INLET & OUTLET TEES AS REQUIRED. BOTTOM ELEV.=96.50-� 20 D (n 3) MAX. COVER TANKS, D-BOX & S.A.S. SHALL BE 36". 4' MIN. NATURALLY OCCURRING +� .15 4) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS VIOUS MATERIALS EFFECTIVE WIDTH=11.6' PERVIOUS � PRIOR PRIOR TO CONSTRUCTION. 5) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE 5' MIN. ABOVE HIGH GROUNDWATER (LEAVE 0.1"BETWEEN ROWS) EXISTING SUITABLE S.A.S. LAYOUT I--11.6+yi AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. ADJUSTED G.W., EL=91.4 - MATERIAL USE 4 ROWS OF 7-ADS Arc 36 HD UNITS IN A STONELESS 63.5" CONFIGURATION WITH BED DIMENSIONS OF 11.6' x 35.0' SEPTIC SYSTEM PROFILE TYPICAL SECTION 13" N.T.S. 33.8" M19 SOIL LOG DESIGN CRITERIA DATE: MAY 29, 2018 SOIL EVALUATOR: PETER McENTEE PE(SE#1542) TOP VIEW NUMBER OF BEDROOMS: 2 BEDROOMS WITNESS: AMY VON HONE RS HEALTH AGENT Ila SOIL TEXTURAL CLASS: CLASS I ELEV. TP DEPTHll so" DESIGN PERCOLATION RATE: <2 MIN/IN 95.6 A 0 CAP FRONTCAP VIIEW SIDE VIEW DAILY FLOW: 220 GPD LOAMY SAND 10YR 4/2 END CAP REAR/TOP VIEW DESIGN FLOW: 330 GPD 95,1 6" GARBAGE GRINDER: NO-S.A.S. NOT DESIGNED FOR GARBAGE GRINDER B LOAMY SAND NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT SIDE VIEW TO CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY 10YR 5/8 DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE. LEACHING AREA REQUIRED: 330 GPD) = 445.9 SF 93.3 28" 4640 TRUEMAN BLVD .74 GPD/SF C1 SILT 'LOAM • wpmHILLIARD, OHIO 43026 Arc 36 DETAIL PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY 5Y 5/3 95.5 54" 1!-IyJ U ADVANCED DRAINAGE SYSTEMS, INC. UNITS MUST BE STAMPED HD PROPOSED SEPTIC SYSTEM UPGRADE PLAN INFILTRATOR IM-1530 GALLON PLASTIC TANK C2 FINE SAND STRIPOUT TO PROPOSED D-BOX: 1 INLET, 4 OUTLET (MINIMUM), H-10 RATED 5Y 5/3 "C2"HORIZON = 91.4 ADJ. G.W. 50" 44 LOWER BROOK ROAD, SOUTH YARMOUTH, MA USE 4 ROWS OF 7-ADS Arc 36 HD UNITS IN A STONELESS 90.9 STG. G.W. - 56" CONFIGURATION WITH BED DIMENSIONS OF 11.6' x 35.0' Prepared for: Caribbean Realty, Inc., 7 Elm Lane, Mashpee, MA 02649 BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.80 SF/LF OF UNIT) Engineering by: Surveying by: SCALE DRAWN JOB. NO. (Arc36 Units) 28 UNITS x 5.0 LF x 4.80 SF/LF = 672.0 SF 85.6 120" Engineering Works, Inc. JC Engineering, Inc. N.T.S. P.T.M. 196-19 DESIGN FLOW PROVIDED: 0.74 GPD SF 672.0 SF = 497.3 GPD / ( ) PERC RATE <2 MIN/IN. "C2" HORIZON 12 West Crossfield Road Forestdole, MA 02644 2854 Cranberry Hwy. E.Wareham, MA 02538 DATE CHECKED SHEET N0. NOMINAL AREA OF BED = 11.6' x 35.0' = 406 SF STANDING G.W. ® 56", (EL.=90.9) INDEX WELL, MIW-29, ZONE A, WATER LEVEL=6.5, ADJUSTMENT=0.5', MAY 2019 (508) 477-5313 (508) 273-0377 6/25/19 P.T.M. 2 Of 2