Loading...
HomeMy WebLinkAboutReview Checklist :Ze TOWN OF YARMOUTH /7 d � � SEWAGE PLAN REVIEW CHECKLIST ) ` Location: A.M. /6- Lot /6 Zone of Contribution: In Out Acreage Commercial: Residential: k Street: l/S Village: �� Floor Plan: #Bedrooms: 4) _ Owner:Installer: .�lj5`- d ,'yl Address: i ��`` Phone: Phone: Builder: Engineer: gr-ep,./Ze, ,7- ,/teikil Address: Phone: 9J'-39? Phone: - vfeo lJ/c 6 6/1/7/4-rd N/A N/A YES /NO 1.Required#of copies received i_/' �32.Date of soils exam and percolation test not older than 2 years i.---- 3.4-5 .4-5 ft of naturally occurring pervious material,above water table L./'- 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: t....----- 6. /6.Benchmark indicated and shown-NGVD if near wetlands [--------. 7. Septic tank minimum 10 ft from foundation,deck Var.: t----' / 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 49 i..1 ' ✓ 9.Leaching minimum 100 ft from wetlands Var.: Gil' 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 1 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: \...7:, 13.Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: .✓/ 15.System not in top or subsoil(A,B horizons)or 5'removal 16.'Proposed contours are suitable t/ 17.System meets slope requirements-min. 1/8", Vs"preferred _ �/ 18. System meets breakout requirements PVC liner: Wall: ✓ 19. Specified tee sizes are proper, gas baffle on outlet tee 20.Sewage is under 10,000 gpd for parcel -"'21.No garbage disposal L 22. System adequately sized for its intended use • 23.Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade,pump chamber cover to grade 25.Inspection port on plastic chambers/leach field IV 26. Electrical permit for pump chamber/Separate meter for duplexes L/ 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed i..7 29.Vent provided if leaching below 3 feet,under driveway/parking ,/' 30.Buoyancy calculations for tank/pump chamber `� 31.Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature `/ 33. H-20 loading is subject to vehicular traffic,groundwater L� 34.Title V Application and permit fee,installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house L----- 36.Deed Restriction required max. #bedrooms: max. flow: gpd c(? `` 37.Check area lots for groundwater/Label groundwater in Assessor's Map j Plan reviewed by: 7 6/03/03