HomeMy WebLinkAboutBld-18-003797 (2) HOME ENERGY RATERS L LC
BUILDING PERFORMANCE TESTING
Ot - I%-003)y)
Air Leakage Report
9 Flakeyard Test Mode
Yarmouth Depressurization
06/06/2019 Test Pressure
50.0 Pascals
Viktar Tuleika
Test Equipment
2015 IECC Energy Code Minneapolis
I� F;
Total Air Leakage or Air Changes Per Hour Gauge
479 2.72
Conditioned Volume
10565
This project meets the criteria for the following:
2009 International Energy Conservation Code
2012 International Energy Conservation Code
2015 International Energy Conservation Code
180 STATE ROAD SUITE 2U SAGAMORE BEACH,MA 02562-(508)833-3100-ENERGYCODEHELP.COM-INFO@ENERGYCODEHELP.COM
powered by cgocanvas www gocanva s.com
HOME ENERGY RATERS L LC
BUILDING PERFORMANCE TESTING
Duct Leakage Report
9 Flakeyard Test Mode
Yarmouth Pressurization
06/06/2019 Test Pressure
25.0 Pascals
Viktar Tuleika Testing Equipment
2015 IECC Energy Code Minneapolis
r
/ t
Total CFM@25 Or Total Duct Leakage Percentage
23.00 0.04
Total Square Footage
656.00
Maximum Allowable Leakage
26.24
HVAC Duct Test
Unconditioned 656 C 23 0.04
9 Fla key ap
Closet
180 STATE ROAD SUITE 2U SAGAMORE BEACH,MA 02562-(508)833-3100-ENERGYCODEHELP.COM-INFO@ENERGYCODEHELP.COM
powered by gocorwos www q oca nvas.com
HOME ENERGY RATERS L LC
BUILDING PERFORMANCE TESTING
Ventilation Report
Ventilation Tests
Master Bathroom 18
9 Fla ktyaes)
3,rr,t '7,.►
Compliance Option el:
Follow these steps to determine compliance for the fan Airflow.
1) Determine the floor area of the conditioned space of the home=(A,,,")
2) Determine number of Bedrooms.(,f«r)
3) Insert these number in the formula Below:
Fan airflow(CFM)=0.01Anco,+7.5(f 1)
Fan Airflow for Homes with Average Air Leakage
Floor Area(ft2) No.Of Bedrooms
0-1 2-3 4-5 6-7 >7
<1500 30 45 60 75 90
1501-3000 45 60 75 90 105
3001-4500 60 75 90 105 120
4501-6000 75 90 105 120 135
6001-7500 90 105 120 135 150
>7500 105 120 135 150 165
Fan airflow is CFM.
Chris Mazzola
180 STATE ROAD SUITE 2U SAGAMORE BEACH,MA 02562-(508)833-3100-ENERGYCODEHELP.COM-INFO@ENERGYCODEHELP.COM
powered by gocanvas Vvww g oca n va s.corn
"gui HOME ENERGY RATERS LLC
BUILDING-TAr PERFORMANCE TESTING
RTIN#8873503
.1(
180 STATE ROAD SUITE 2U SAGAMORE BEACH,MA 02562-(508)833-3100-ENERGYCODEHELP.COM-INFO@ENERGYCODEHELP.COM
powered by cfJcanvas www.ciocanvas.com