HomeMy WebLinkAboutReview Checklist SIN
TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: AM 23 LOT/3i-.2.-- Date of Subdivision Approval
Street 4' � /i /�ez> Zone of Contribution: In Out /
�
Village ehoviem-771 Commercial Residential
Owner: L i Zr'/ 6:-/2„cot Installer / /S1 I
fed Tali '/ ►c3/ /' Ok. 790-922-,3 77/ -7 3,7
Builder: 7.11,ite Engineer / sC'"-Ov'e..0.30,,fleBo't362.
N/A YES NO
1. Required number of copies received.
2. Date of soils exam and percolation test not older than 2 years. �/
3. 4 feet of naturally occurring pervious material above water table(new construction)
4. Foundation 2 feet above high point of fronting road for new construction. i/
5. Water availability letter from Water Department for new construction.
6. Benchmark indicated and shown-NGVD if near wetlands. -t/'
7. Building sewer does not exit center of house.
8. Septic tank a minimum of 10 feet from house and deck. L/'
9. Leaching a minimum of 20 feet from house and 10 feet from deck. 4./
0. . . . . ii'i-._t L • I I , • H we l:1 •
11. Leaching a minimum of 150 feet from drinking,wells/25 feet from irrigation wells.
12. System meets all other setback requirements._ t,----"'
13. Uses adjustment for maximum hi ter. i./
14. Leaching 4-5 feet above water table bottom of test pit.
15. System not in toper subsoi or .of remov.
16. Proposed contours are suitable.
17. System meets slope requirements-min. 1/8". 114" preferred. v_/
. vYe , t.- 4 . - . , u e•u - ..-_s - ..a: Yi1, 1- • ' . ._li,. . i - - (.t-1 Al.
19. Specified tee sizes are proper. gas baffle on outlet tee.
. 20. Sewage flow under 1 O.ON gpd for parcel. t.-------
21. No garbage disposal: .. /'
22. System adequately sized fir its intended use.
• 23. Minimum 6" stone or mechanically compacted below the tank and d-box. ��
24. Manhole covers within 6" of grade-septic tank and pump chamber. c/
25. Electrical permit for pump chamber.
26. Pump system-?" line. weep hole. check valve, sanitary in d-box. alanmon separate circuit.
. S- .tc • . .. • h_. . _moi. .,__.] .;4 t. .- F• t._a wat-_ i... - 4
V- . . i.e• ' " -CLQ' • _1W it . . - a . ti,ti . . •_IP .1.
29. Engineer to inspect and certify : a. clay removal
b. wall construction schedule
c. commercial system .,/`
30. Engineer and Land Surveyor stamp and signature.
f31. H2O loading when system subject to vehicular traffic.
32. Title V application and fee signed by a licensed installer. ,.
33. Foundation footing 2 feet above adjusted water table. „.
34. Lot subdivided prior to July 31. 1986 - Nitrate Loading. ..........7-
35. Subdivided prior io April 7. 1989 - Phosphorus Zone 300'.
Plan reviewed by: 7