HomeMy WebLinkAboutEletrical Misc ) ) ) Y WAL CAP _ . BERKO RUX300812 g EXPLOSION PROOF UNIT w HEATER. 3KW, 208/1/60,\ WITH WALL MOUNT T'STAT N. ODOR CONTROL a ROOM z ir 8" INTAKE WALL CAP WITH BACKDRAFT DAMPER AND N 7"0 S BIRD SCREEN, MOUNTED -4`- NEAR CEILING m z 0 elu GREENHECK CSW-7-BI-21-10-0-4 .. UTILITY SET TYPE EXHAUST FAN, li g 3 - = SPARK RESISTANCE TYPE B, 100 WAT /a CFM, 0.2" ESP,Y HP, 208/1/60. MENT 0 HUILDING MOUNT ON WALL WITH NEOPRENE . VIBRATION ISOLATORS. -- 8"0 UP TO ROOF CAP GREENHECK SP-A290 CEILING COVERED C/D WALKWAY EXHAUST FAN, 250 CFM, 0.2" ESP, 81W, 120/1/60, WITH SOLID STATE AM \ W SPEED CONTROLLER, STEEL GRILLE vO. AND WALL-MOUNT T'STAT (FAN TO QT ACTIVATE WHEN ROOM TEMPERATURE „ F" RISES ABOVE SETPOINT) (2am' f /v LOUVER, 1 ED - 02 INTAKE a rn /�—/ " LOUVER, 18X12, KALE MOTORIZED DAMPER AND BIRD c) SCREEN. DAMPER TO OPEN EN �y y BUILDING MAINTEN' CC ROOM EXHAUST FAN OPE S. °1 STORAGE _ �� . O p' P ���- °=1 F. :w= 41F., ...i.z: • of . CON$ULTING ENGINEERING ' SERVICES - KDI 17 Ivaloo Street March 21,2019 Somerville,MA 02143 Subject:Yarmouth Commons Waste Water treatment Plant-Odor Control Room Attention:Mr.William Chalfant Mr. Chalfont, The Odor Control Room in the Waste Water Treatment Plant at the subject project shall have Class 1/Division 2 rated electrical components, equipment, light fixtures/switches and the wiring methods shall comply article 501 (section applicable to Class 1 /Division 2)of the MEC 2017 (Massachusetts Electrical Code).Attached is,a package with datasheets for equipment and raceways that are to be used. Please do not hesitate to contact me if any additional information is required in this regard. Sincerely, • Amish D. trft' Nu 4t '5txr 14 RECEIVED CEP 3 2019 BUILDING DEPT Abiish Patel,P.E. By www.all(edconsuiting.net 235 Littleton Road,Suite 5 151 Levan Street Westford,MA 01886 Warwick,RI 02888 978.443.7888 401.461.7888 I ICI ` CONSULTING ENGINEERING SERVICES KDI March 21,2019 17 Ivaloo Street Somerville, MA 02143 Subject: Yarmouth Commons Waste Water treatment Plant-Odor Control Room Attention: Mr. William Chalfant Mr. Chalfont, The Odor Control Room in the Waste Water Treatment Plant at the subject project shall have Class 1 /Division 2 rated electrical components,equipment,light fixtures/switches and the wiring methods shall comply article 501 (section applicable to Class 1 /Division 2)of the MEC 2017 (Massachusetts Electrical Code). Attached is a package with datasheets for equipment and raceways that are to be used. Please do not hesitate to contact me if any additional information is required in this regard. Sincerely, Nko Amish Patel, P.E. www.alliedconsulting.net 235 Littleton Road.Suite 5 151 Lavan Street Westford,MA 01886 Warwick.RI 02888 978.443.7888 401 461 7888 • Chan MLL LED CI. I, Div. 2, Groups A, B, C, D UL Listed 2L p Cl. I, Zone 2 CSA Certified luminaires CI. II, Div. 1, Groups F, G Marine &Wet Locations CI. III NEMA 4X; IP66 • The Champ MLL linear LED .s specifically designed to replace floc.scent T12, T8 and T5H0 lighting In harsh and hazardous 1 applications. The rugged an curable design features the industry y c most versatile and flexible mooning options. The Champ r LL is the :deal solution for hlgn vibration, impact and nose doom applications. Lumens Typical energy "•+say„ ,. Typical per Equivalent HID savings/ � " Model lumens Watts watt luminaire lifetime T121I0 Up to 67?, T8H0 Up TO 63 0 MLL2 3,600 29 124 TbH0 p io y T12 Up to 42°ria T8 Up to 32% T5 Up to 17% Mounting (ordered separately): T12H0 .gyp.o 64% TBH0 Up to 60% Versatile mounting options: Easily retrofit to: MLL4 7,100 54.5 130 T H 0'c • Flush!back mount • Existing Paulunn' DuraPro and T12 Upto46r'a T8 Up to 32 4; • Swivel/ceiling back mount PlagnaPro fluoresces?fight T5 Up to 22% • Offset ceiling mount fixtures • Offset wall mount • Rig-A-Lite' and Snelson"C'.D2 Applications: fluorescent fighting fixtures • Pole mount • Oil and gas refineries, petrochemical facilities,food and beverage • Pendant mount facilities, platforms, loading docks: tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable Certifications and compliances: vapors, oases, ignitable dusts,fibers or flyings are present NEC: UL standards: Features: • Class I, Division 2, Groups A. • UL844-Electrical Fixture • Industry-leading efficacy up to 130 LPV^,i E., C, D Hangers for Hazardous • -40°C to-65°C ambient operating temperature • Class I, Zone 2 Locations ,etas;and!rodeL! • IJL1598-Lur•:minaire • Low profile fixture(<3" height) • Class II, Division 1, Groups F, `J r; • UL159B.A-Luminaire for • `.'ersatile ceiling/swivel,wall, flush, pole and pendant mounting Installation on Marine Ves els options • Class III fi • NEt'°4X, IP66 • UL924-Emergency Lighting • , ide and narrow optics for uniform illumination • f��larir:.e and wet locations CSA standard: • Four points of secondary retention • C22.2 No. 137 • 2,000 PSI high pressure hose rated Additional certifications: • High vibration resistance • • Emergency battery back-up(90 minutes)and surge protection ABS design assessed options (up to 10101)O Electrical ratings: • DesignLights Consortium'''Qualified(some models are not DLC qualified)O MLL2 MLL4 • 5 year fixture warranty Lumen output 3,600 7,100 requency b0/60 Hz 50/60 Hu Standard materials: Voltage 100-277 VAC,108-250 VCC;347-480 VAC • Housing-copper-free aluminum; Corro-free epoxy powder coat Current Power (optional) Model Voltage (A) Watts factor THD • Lens-glass; polycarbonate, diffused glass, diffused polycarbonate M',LL2'UNV1 100 0.28 28.2 0.90 <20% (optional) MLL2/UNV1 277 0.12 29.4 0.90 <20% MLL2/UNV34 347 0.09 29.2 0.90 <20% Photometrics: MLL2/UNV31 180 0.07 30.1 0.90 r20% MLL4/UNV1 100 0.55 55.0 0.95 <20% • Complete photometrics can be found at sv,^•;w.crous h nds.cam! ` MLL4/UNV1 277 0.20 54.5 0.95 <20010 photometrics MLL4/UNV34 347 0.16 55.8 0.95 <20% Temperature performance data: h✓1LL4lUNV34 480 0.12' 56.2 0.35 <20% Simultaneous rating Weights: Ambient Min.temp. Class I, Class II, Class I,Div.2; Model Lbs. Kg. temp.°C supply wire°C Div.2 Div.1 Class II,Div.1 MLL2 12.50 5.70 40 60 T6 T6 T6 MLL4 22.50 10.20 55 75 T5 T5 T5 65 90 T5 T5 15 cone year warranty. ()Refer to www.designhghts.org Ouaified Products List under Family IVIo-dels for full listing details. Not all models are approved for all application categories. E A N CROUSE-HINDS SERIES www.crouse-hinds.com US."-R6o--764-5,154 CAN.':-800-265-0502 Copyright' 2019 Eaton 93 • Cham Cl. I, Div. 2, Groups A, B, C, D UL Listed 2 L p CSA Certified luminaires CI. II, Div. 1, Groups F, G Marine & Wet Locations CI. III NEMA 4X; IP66 IDesigned for harsh and hazardous. Champ MLL linear LED luminaires are engineered to handle demanding conditions. The MLL stands up to high vibration, hose down, shock and impact, while delivering long lite and high lumen performance for up to 20 years. Custom optics: Comprehensive certification: Quick&easy installation: • Standard wide !120 I beam spread or •control • Single model certified for • Easy access to drivers and:h-iring cc n and indoor application maximizes use in Class I, Division 2 and • No custom brae:ets or.h:ard,•tia"e needed illumination or:wall panels Class II, Division 1 harsh and • IVa'rOV•i (g1 =; beam8(reau•Option for azardous applications • Seven mounting opti ns available targeted illumination; avoids spillage and light loss Built a last: Slim profile: • Ingress protect!or:.from hose down water or diesel fuel ir:. Harsh operational • 2J" fixture ^.e ght(excluding mounting brackets) conditions—passed 2,000 PSI high • Perfect for mounting in confined or low height areas pressure test • Vibrat!on-, impact and shock-resistant— passed 5G. 3-axis vibration test fi 60,000 hour lifetime at 55°C ambient v t . M Best-in-class efficacy: �+wa • Up tc 13C lumens per L^Jatt BITN CROUSE-HISERINDSES 94 :wwve.creus�-h nda.cem IJS. '.-866-764-5454 CAN. 1-800-265-0502 Copyright' 2019 Exton ham MLL LED CI. I, Div. 2, Groups A, B, C, D UL Listed 2L p CI. I, Zone 2 CSA Certified luminaires CI. II, Div. 1, Groups F, G Marine &Wet Locations Cl. III NEMA 4X; IP66 Ordering information: Part number example LL4N/UNV1 S903TF P EM1 MLL 4 N /UNV1 S903 TF P EM1 .. , Series Optics Lens Emergency back-up 1k1LL Champ MEL linear BLANK Wide 11201 BLANK Class Integrated LED luminaire N Narrow(PO°I s891 Diffused glass EM1° emergency battery S903 Polycarbonate back-up Length I lumens Voltage 0, S9030 Diffused polycarbonate Remote • 4 4ft.length,7,100 rumens fUNV1' 1 10-277 VAC;138-250 VDt. EM emergency kit 2 2 f.length,3,600 lumens /UNV34 341 400 VAC Options 0 Finish TF Pull wire included in BLANK Natural aluminum fixture P Painted Igray,epoxy) WH Painted{white,epoxy) Accessories (ordered separately): Description Cat.# Description Cat.# • Flush/back mount back plate DP1057MTK • Pendant mount kit PEND HAZ KIT u.mpat%iie with DuraPro • Sa`ety chain kit SS KIT `/ • Ceilingiswi'vel mount DP1050MTK • 1 amp driver replacement kit, 100-277 VAC for Compatible with DuraPro 4 ft. linear VMVL/UNV1 80W 1A KIT • Ceiling/wall mount offset DP1053MTK • 1 amp driver replacement kit, 347-480 VAC for G^'77,iai%ble with DuraPro 4 ft. linear VMVL/UNV34 80W 1A KIT • Ceiling mount bracket and adapter kit MP1054MTK KIT • 0.5 amp driver replacement kit, 100-277 VAC for Compaube witr,Magna Pro 2 ft. linear VMVL/UNV1 80W 0.5A KIT • Offset wall mount DP7052MTK • 0.5 amp driver replacement kit, 347-480 VAC for 2 ft. linear VMVL/UNV34 80W 0.5A KIT Compembie WI to DuraPro • Pole mount kit, 1.25" conduit PM KIT 1.25 • Pole mount kit, 1.50" conduit PM KIT 1.5 • Pole mount kit, 2.00" conduit PM KIT 2.0 Dimensions and mounting options: 1329.1i _ ,-7�9: 1719 2:333.. i-JS.58, 6 .,_:... r 9 •7 i635e . N7I V \: V MLL4 MLL2 t srpoo ,d.0000/.04V. Offset wall Flush ceiling Offset ceiling Ceiling/swivel Ceiling and adapter Pole mount Pendant mount DP1052MTK DP1057MTK DP1053MTK DP1050MTK MP1054MTK KIT PM KIT 1.25/1.5/2.0 PEND HAZ KIT ' V °One yea,warranty. Remote EN/kit also a'.ailable. .Avaiiable for 4 ft.model only. E A •N CROUSE-HINDS SERIES wvr.crouse-ninds.com US.'-856-754-5u5z. CAN.1-800-265-0502 Conysght' 201,Eaton 95 ChampMLL LED CI. I, Div. 2, Groups A, B, C, D UL Listed 2L CI. I, Zone 2 CSA Certified luminaires CI. II, Div. 1, Groups F, G Marine &Wet Locations CI. III NEMA 4X; IP66 111 Mounting options: Ceiling/swivel mount - - DP1050MTK s.^ A" to P.0.390 'a'� ' mtg.hole r J MLL2 MLL4 ' Length in. mm. in. mm. A 28.3 720 523. 1329 8 9-27 222-681 9-5" 2.22-1289 Pole mount K A >' ALL MEASUREMENTS IN INCHES PM KIT 1.25/1.5/2.0 I `` B ��\ I Configuration A B C D / `v_ A PM KIT 1.25 4.331 3.543 1.680 1.693 1_NE , ` as I PM KIT 1.5 3.740 2.953 2.000 1.535 � c " PM KIT 2.0 3.386 2.598 2.360 1.378 /" E /I 1 E._ F � O �J o ;K MLL2 MLL4 6,' Length in, mm. in. mm. • 28.3 720 52.3 1329 F 12-21 305-533 24-45 610-1143 MagnaPro mount MP1054MTK KIT r' 1 ZBE 1188.6. I'13.3i --A/ 0.275 V 1 ---'-' B _ mtg.note -111/" u. L ek MLL2 MLL4 • 00'► \�\/ Length in, mm. in. mm. 0.275 / A 28.3 720 52.3 1329 mtg.hole ;B 17-77 305-559 24-46 610-1168 E iT•N CROUSE-HINDS 96 vd.,,av:Crouse-h:nas.com US:i-866-764-5454 CAN: 1-800 265-0502 Copyright" 2319 Eaton Ii SERIES , . Cham MLL LED a I, Div. 2, Groups A, B, C, D UL Listed Cl. I, Zone 2 CSA Certified 2L p luminaires a II, Div. 1, Groups F, G Marine & Wet Locations CI, III NEMA 4X; IP66 Mounting options (continued): Offset wall DP1052MTK I lic I . , t 0 0.375 ,--' , -- - -, I ' ..--- ---- ta'4..-013- ,.. ,-- ,------- .-- __)111% ,--- MLL2 MLL4 .---'-- -- Length in. mm. in. mm. A 28.3 720 52.3 1329 8 26.3 669 50.3 12/8 Offset ceiling/wall mount -r DP1053MTK .-- ..------' ,--1 *..,.. 0 0.375 r mtg.note , .4.--' ,--- A -- „---' ,-- --- ,--- ---r - B ,„, . ., ____,..,... -, 4-----1 - 6'..1: 1 , (k)) rawlej4n '1.tiwt.NIIIIV .... MLL2 MLL4 Length in. mm. in. mm. A 28.3 720 52.3 1329 B 26.3 584 47.0 1194 /.7.' Flush ceiling ---',-- ,- lr 4 ...- ,....- '....., .--- .- i..., A ---- , A „ , --, ---' ' • 71, -E,-:-1431rT-••"rffld, .., I; MLL2 MLL4 lad 0 %V (D.' ,, Length in. mm. in. mm. A 28.3 720.0 52.3 1329.0 B 6.2 157.5 18.2 462.0 ILIT•N (ROUSE-HINDS SERIES wwyv c-o.se-ninds curl US."-866-764-52.54 CAN 1-8C0-255-0502 Coovngh: 2010 Eaton 97 Champ MLL LED CI. I, Div. 2, Groups A, B, C, D UL Listed 2L CI. I, Zone 2 CSA Certified luminaires CL II, Div. 1, Groups F, G Marine &Wet Locations CI. III NEMA 4X, IP66 IMounting options (continued): Pendant mount—Class I,Division 2 only PEND HAZ KIT r 4 t,,,,_.---..'----------.-/-',._-: 0,k4 0* ''''\91P.'" ,_. ___ ,_. --' ,-----,,--,:-...-- ---7-.. :' „ �� MLL2 MLL4 :/' Length in. mm, in. mm. 1 4 31.7 805 55.E 1418 B 28.3 12(} 5L.3 1329 ��e C 4.2 108 6 0 406 .")E 31 5 4671 "<� 12.2 310 24.0 610 \T4_ E 34.9 886 58.9 1495 -L. - — _ D ): i< C '1 �0, I� `a [![ I '\ r-',i ------- — 0 ipr o i T - ._-- i '( E- �i ai N CROUSE-HINDS 98 �.a•wv:grouse-hnos.ccm OS�i-856-764-5454 CAN -900-265-0502 Ccpyng^T" 2019 Eaton m � SERIES Cham MLL LED Cl. I, Div. 2, Groups A, B, C, D UL Listed 2L P CI. II, Div. 2, Groups F, G CSA Certified luminaires Wet Locations Integral battery back-up Type 4X; IP66 Champ MLL linear LED luminaires are available with an integral battery back-up module. Virtually the same size as the standard foot model and 90 minutes of emergency lighting to keep your fac':Sty and personnel safe. „,.::„,„....„,,,c.„,„. I Model EM output Normal output h1LL4/U',J r1 EM1 100 lumens 3720 lumen Applications: • Egress and emergency lighting for areas re. uin na uninterrupted lighting during power failure • Hazardous rated indoor and outdoor emergency lighting in manufacturing plants, heavy industrial, chemical and petrochemical facilities, platforms, loading docks and parking areas Electrical ratings: Features: EM output Normal output • Operating ambient: 0°C to+40`C voltage 120 _77 • 90-minute run t me in emergency mode Amperage at120VAC 0.480 0.212 'for tat p-at 57.8 57.7 • 6,720 20 lumen output or normal operation: 1,400 lumen output in Limes output..: 1,400 6,720 emergency mode eouancy 50/60 Hz 50/50 Hz • 50,000 pours rated life at 40°C Power factor at'100 VAC 0.997 0.980 • I?66 rated enclosure THD 6.58 `- 'U • LED indicator to check battery operation • Nickel cadmium battery Temperature performance data: • 1 year warranty Simultaneous rating ` Ambient Min.temp. Class I, Class II, Class I,Div.2; ..r Certifications and compliances: temp.`C supply wire'C Div.2 Div. 1 Class II,Div. 1 NEC/CEC: 40 50 T5 T8 T5 • Class I, Division 2, Groups A, B, C, D • Class II, Division 2, Groups F, G Photometrics: • Wet locations,Type 4X, IF66 • Complete photometrics can be found at•.vww.crouse-hinds.com/ UL standards: photometres • UL844—Hazardous (Classified;! • UL1598—Luminaires • UL1 598A—Marine • UL924—Emergency Lighting CSA standard: • CSA C22.2 Nos.250, 137, 141 Dimensions: 11247-'.I Ei 5 C:i. ▪ :58 2. __ mil•+[ f —FOLYCARBONATE LENS SHOWN i. ; t r� s-6o ...... IRE _ G i . _ — 1A .__._ .,_., ..... • _,_ IL ..�, fy`e.P R7 �1 'i5': 1X?�-.mil :1325.1] 52.33 Fr AT•N CROUSE-HINDS SERIES w v v c._..s.Smds.rom us..-,-866-764 545,n CAN.1-800-265-0502 Coovngh:° 2019 Palos 99 Light Switch cCSAus Certified CI. I, Zone 1 & 2 Ex de IIC T6 2A Cl. I, Div. 2, Groups A, B, C, D CI. I, Zone 1 & 2 AEx de IIC T6 CI. II, Div. 1, Groups E, F, G CI. II. Div. 2, Groups F. G Applications: GHG273 series of switches are used: •To prevent arcing of enclosed switch z from causing ignition of a specific 1 hazardous atmosphere external to the enclosure • In Division 2,Zone 1 and Zone 2 industrial areas such as:chemical plantsh , li . oil and gas refineries, paint and varnis manufacturing plants,gasoline bulk loading terminals, grain elevators and processing industries,coal processing or . , handling areas, or finishing areas where atmosphere may contain hazardous - gases and/or dust • In non-hazardous areas where sturdy, durable enclosures are required for both indoor and outdoor installations of light , switches Ordering Information: Features: Cat.# Contact Arrangement Description Entry Size •Small and compact in design. GHG 273 2000 L0005 tI it 2-pole 1 x /2" NPT(bottom) • Large grounding plate. GHG 273 2000 L0006 -� 2-pole 1 x'/4" NPT(bottom) GHG 273 2000 L0012 L 'Nj 2-pole 1 x M20(top). Captive2 x M20(bottom)' > • cover screws. • Protective collar for inadvertent operation. GHG 273 6000 L0001 tit It 3-way 1 x 7,"NPT(bottom) • Large actuator surface allows for GHG 273 6000 L0002 3-way 1 x"/;°NPT(bottom) operation while wearing work gloves. GHG 273 6000 L0007 3-way 1 x M20(top), • Labyrinth seal to guarantee the degree of ,,,na plates included. 2 x M20(bottom)" protection IP66. •The toggle has a luminescent label to Dimensions locate switch in dark areas. In mm: •Cable entry from the top is made possible by turning the base for single entry designs. 85 I 64 IICertifications and 75 11 1 —h-5 " 11 Compliances: •cCSAus Listed © ,o —1 •Class I. Division 2,Groups A, B, C, D ' 0 : = 0 `^ •Class II. Division 1, Groups E, F,G — F_ �� _ I •Class II, Division 2,Groups F,G I•Class I.Zone 1 &2,AEx de IIC T6•Class I.Zone 1 &2. Ex de IIC T6• PTB98ATEX3121 _ • IECEx BKI 07.0036 • IP66 a _, Standard Materials: •Body and cover-low temperature, Dimensions are approximate,not for construction purposes. impact resistant thermoplastic •Shaft and screws-stainless steel •Grounding plate-nickel-plated brass Standard Finishes: •Thermoplastic-natural •Stainless steel-natural • Brass-nickel plate Electrical Ratings: Voltage Current ATEX&IECEx- 250VAC 16A CSA- 240VAC 10A Crouse-Hinds by Ea•F4 www.crouse-hinds.com US:1-866-764-5454 CAN:'-800-265-0502 Copyright' 2C14 Eaton's Crouse-Hinds Business U—Line® Factory Sealed 20 Amp Aluminum Receptacles Explosionproof,Dust-Ignitionproof 125 Vac,20 Amp,1 HP;250 Vac,20 Amp,2 HP.Dead-Front Safety Construction. Class I,Division 1 Groups B•,C,D Class I,Division 2 Groups B,C,D Class II,Division 1 and 2 Groups F,G Class Ill NEMA 3,3R Aluminum Receptacle and Malleable Iron Mounting Box t Catalog Number Hub Size 125 Vac,1 HP 250 Vac,2 HP Type Wire/Pole (Inches) QV Single Gang Class I,Division 1 and 2 Groups B•,C,D;Class II,Division 1 and 2 Groups F,G;Class Ill. Suitable for use in Class I,Division I,Group a when used with external seals.r 1/2 EFS150-2023 :�F51SO-20232 e' Dead-End 2W,3P 3/4 EFS175-2023 'EFS175.20232 1 EFS110-2023 EFS110-20232 r = 1/2 EFSC150-2023 EFSC150-20232 - f, '' - Feed-Thru 2W,3P 3/4 EFSC175-2023 EFSC175-20232 1 EFSC110-2023 EFSC110-20232 N Dead—End Feed—Thru Two Gang Class I,Division 1 and 2 Groups C,D;Class I,Division 2,Groups B,C,D;Class II,Division 1 and 2 Groups F,G;Class III. = Q _` ! 1/2 EFS250-2023 EFS250-20232 Dead-End 2W,3P 3/4 EFS275-2023 EFS275-20232 ` 1 EFS210-2023 EFS210-20232 \.../ o 1/2 EFSC250-2023 EFSC250-20232 a 4-' Feed-Thru 2W,3P 3/4 EFSC275-2023 EFSC275-20232 .cc1 EFSC210-2023 EFSC210-20232 = Dead—End Feed—Thru H J V In a Replacement Receptacles W Lil 2W,3P EFSR-2023 EFSR-20232 aSpring Door Replacement Assembly(aluminum) ULSCA *., Receptacle for use on Killark 4 SWB Boxes. EFSR-2023K EFSR-20232K G- z :0 '. NEMA 4X Corrosion Resistance Kit• ULINEREC4XKIT t Standard back box malleable iron.For aluminum back box,add suffix A to catalog number. $Seals(not furnished—see Fittings Section)must be placed within 2 inches from each conduit opening.Seals are not required in Class I,Division 2 locations. V NEMA Type 4X when the screw cover is installed and the cover is fully engaged. •Shaded area innqCates items suitable for Coss I Group El C and D Class II,Gioups F,G.;and Class/f1 ` J O Killark is a registered trademark of Hubbell Incorporated. Y 826 visit our website at www.appletonelec.com or contact us at(800)621-1506. CaAppleton$ 0 October 2012 NEMAType 7/9 Disconnect switch -" ,, 4 CRtIUSE-fdlNnS ° €, ,. .a.,.:,". _ _� , .. ���°. x._...:,._„„„� ��Jy fir,,° ° " 3m ,g ma`s,. >4 . r . x ' t _ N/ 'fir. • e •'•rfi \ viiiit::: , .. ' , , ,,, ,,,,,, :.,, , ,,., ,' ' , ' ',:.. rzh.f.. ;tea..� i... .ems. ,:;;i�'`"�,= *,,,-.,t .):-fl% - ",:=4,,",,.. .11:j[Arm to,r: * m 't Fis i e ..„,,,, ,,,,,,,,,„„„:._, ,,,1::::4,4„„ .„:„..:,„..„„.... i1pèIPi,Li .zB: �iA..� nab. :,%f„ Nx. x'�G"+^, ='.,?�.,, `•:,� .i r\,e' .�c;,;r ia• �.,lvi,F, yf,;;' ��•t.s5x�ify;,?- ny h.'tt' n• • 7. . .. - ,•M� _, � .. .,�,:�s�.' :rk;-tea.;�k ,.b• .� >. �. ZT EJ•N ..., Powering Business Worldwide Safety and reliabilit in a compact, space-efficient NEMA Type 7/9 enclosure Features and benefits • Available in both fusible and non-fusible configurations—offers Aleat flexible options for different circuit protections ,_ `� • Small, compact footprint—less mounting space required • Large red painted aluminum rotary handle operator mounted on ,,p. cover assembly provides rugged, reliable performance in the field and allows for the switch position to be easily identified Neoprene cover gasket provides NEMA 4X ingress protection • Detachable/adjustable mounting feet provides flexible mounting alternatives for ease of installation; no need to replace the entire enclosure if a mounting foot is broken • Stainless steel hinges—easy internal access for wiring and maintenance k • Two 1/2-inch NPT conduit entries, one on top and one on bottom• for field addition of breather and/or drain or for use with auxiliary "� s contacts; holes come plugged with Eaton's PLG explosion-proof :, • plug as standard 0 y • Provides lockout/tagout capability that complies with OSHA requirements—allows for locking in the ON or OFF position for standard maintenance checks • • Complies with NEC®Article 312 wire bending requirements for maximum wire gauge—allows for easy and safe installation, and reliable operation of the product 0 For more Information,contact the Flex Center at 888-329-9272. Certifications and compliances Standard materials The NEMA 7/9 disconnect switch provides an explosion- • Class I, Divisions 1 and 2, • Body and cover— proof disconnect with overload and circuit protection for Groups B, C, D copper-free aluminum hazardous area electrical systems.This disconnect solution • Class I, Zones 1 and 2 • Gasket—neoprene incorporates Eaton's high-integrity manufacturing standards • Class II, Division 1, • Cover bolts—steel, for safety and reliability in a compact, space-efficient Groups E, F, G stainless steel NEMA®Type 7/9 enclosure. • Class III • Hinges—stainless steel • NEMA 3, 3R, 4, 4X, • Mounting plate 7BCD, 9EFG sheet—aluminum • UL®standard: 1203 • Rotary actuating • cUL®to CSA®C22.2 No.30 handle—aluminum Standard finishes • Copper-free aluminum—natural • Steel—electrogalvanized 2 EATON NEMAType 7/9 Disconnect switch ,. .,.-.. ..,-"4441,i7= ',..,,,,4 :11* .,'*00 , 1".40".'•' '#401„.* 11014-40'' . '70.4\47,01.0iiH1 !„1,''# 44 4440*** -''-."0. ,;, ,.. 41*- -'1--04„,,'''''' " " Adrk00. , z,'0.=-: ° - -,...• .0410-4i'4-",.;44,414414**** ' , r . .• , . . : ^7.'7 k ' '' ,*7.''s .;* •' :,.. .7.; . .-' , . a" '1'4 1- '41142' * ' , .'*Allifr. ';, . -7" 4' _ •,= 4:,:i• . , . , -:4 . " -f.'•'' ''''''-': ,,.. *. , • r ::4,,, •., ' : - .' . ,.. • , , ,• . . .. , . 40 '‘i * : ..• -' k,,, ,...•• „ , . • . ,. • ___ ,040 Electrical ratings 0 Ordering information Non-fusible horsepower rating Fusible horsepower rating Ampere rating Fusible/non-fusible Catalog number Switch Switch 30 Non-fusible DS361UX rating 480 600 250 rating 480 600 250 (amperes) Vac Vac Vdc (amperes) Vac Vac Vdc Fusible DS361FX 30 15 20 5 30 15 20 5 60 - Nan-fusible DS362UX 60 30 50 10 60 30 50 10 ,.,„ Fusible DS362FX 100 60 75 20 100 60 75 20 100 Non-fusible DS363UX 0 Fusible and non-fusible versions are rated up to 10 kAIC at 600 Vac. Fusible DS363FX Dimensions in inches(mm)and weights Non-flan:he disconnect switch Fusible disconnect switch Dimension DS361UX DS362UX DS363UX DS361FX DS362FX DS363FX A 9,74(247,0) 9.90(251.0) 10.28(261.0) 10.02(255.0) 9.90(251.0) 10.40(264.0) 8 5.00(1 27.0) , 7.00(178.0) 8,0012291r 7.00(178.0) ,„ 7,00(178.0} 15.00(380.01 C 10.47(266.0) 12.53(318.0) 14.67 137101 12.67(32210 12.53(318.0) 17.31(440.0) 0 11.13(2830 15.13(364.0) 17,13(435.0) 13131333.01 15.13(384.0) 14,50(292_0) E 12A7(317.0) 16.53(420.0) 18.67(474.0) 14.67(373.0) 16.53(420.0) 23.31(592.0) .., F , 3.90(89.0) 3.50(89.0) 3.50(89.0) 3.50(89.0) 150(89,0) == , 3,50 09.0} Weigh/in lb(kg) 33(15) 51 123) 72(33) 47(21) 51(23) 108(49) C/2 F-.1 II, •limmakil (41 8 1 .0cil 1 4 , Iim 0 11111 E II 11 , I. iti _il . qw-iiiv , .,,,,..._, B 0.44 ... C . (11.0) EATON NEMAType 7/9 Disconnect switch 3 V Eaton 1000 Eaton Boulevard Cleveland.OH 44122 United States Eaton.com ©2016 Eaton Follow us on social media to get the ® All Rights Reserved Eaton is a registered trademark. latest product and support information. Printed in USA Ant Publication No.BR008007EN/Z17593 All other trademarks are property J + Powering Business Worldwide February 2016 of their respective owners. a+«:,; Galvanized Rigid Conduit (GRC) and Kwik-Couple® GRC Palled J TUBE&CONDUIT` ,,, %atkore Galvanized Rigid Conduit (GRC) Quality, Long Lasting Heavy Duty • Hot-dip galvanized for excellent corrosion resistance ti fnd'tit • High strength ductile steel for long life and easy bending • Smooth, continuous raceways for fast wire pulling ... .. • Kwik-Release End Cap to protect threads • True Color'""GRC special orders available '' • Listed to Safety Standard UL 6 .,--a , • Manufactured in accordance with ANSI C80.1 • Available in sizes 1/2 (16) -6 (155) . a y i k-Couple Galvanized Rigid Conduit(CRC) For Faster Installations Use the • Similar Benefits to standard GRC Conduit* �i -Couple CRC Connection • Factory installed Kwik-Couple"' couplings are available on : GRC conduit Just line up the ends, spin the coupling forward onto the next piece and wrench tighten. It's that easy! A. • No separate couplings to purchase, inventory or install - , • Kwik-Release End Cap to protect threads • True Color'"'Kwik-Couple®GRC special orders available 3 • Manufactured in accordance with ANSI C80.1 <"t • Available in sizes 2 1/2 (63) -5 (129) *Kwik-Couple GRC does not contain a listing for wet locations and is not approved for Class I Division I locations. Chart on the following page Kwik-Couple Rigid Elbows • Also available with pre-installed Kwik-Couple Couplings • Made to order, contact us for lead times * U.S. Patent Numbers 7,404,582 and 7,726,001. Galvanized Rigid Conduit (GRC) U. Listed to UL 6, manufactured in accordance with ANSI C80.1 Trade Metric Outside Nominal Wall Approximate Quantity in Size Designator Diameter' Thickness' Weight Per Master Bundle* 100 Ft.(30.5M) in mm in mm lb ky It m 1/2 16 0.840 21.34 0.104 2.64 82 37.2 2500 762.5 3/4 21 1.050 26.67 0.107 2.72 109 49.4 2000 610.0 1 27 1.315 33.40 0.126 3.20 161 73.0 1250 381.3 1 1/4 35 1.660 42.16 0.133 3.38 218 98.9 900 274.5 1 1/2 41 1.900 48.26 0.138 3.51 263 119.3 800 244.0 2 53 2.375 60.33 0.146 3.71 350 158.8 600 183.0 2 1/2 63 2.875 73.03 0.193 4.90 559 253.E 370 112.9 3 78 3.500 88.90 0.205 5.21 727 329.8 300 91.5 3 1/2 91 4.000 101.60 0.215 5.46 880 399.2 250 76.3 4 103 4.500 114.30 0.225 5.72 1030 467.2 200 61.0 5 129 5.563 141.30 0.245 6.22 1520 689.5 150 45,8 6 155 6.625 168.28 0.266 6.76 1785 809.7 100 30.5 Project Information I Tolerances:Trade Size 1/2 to 1-1/2:±0.015"(0.38mm);Trade Size 2-6:±1% Length equals 10 ft.(3.05m)with a tolerance of+/-.25 in.(6.35mm) Company Name: 2 For information only.Not a requirement of the UL standard. Address: *NEMA RN-3 Standard City: State&Zip: Phone: NOTE:Special orders are non-cancelable, non-returnable and Project Name: non-refundable City: State: www.alliedeg.com !bed Galvanized Rigid Conduit (GRC) and Kwik-Couple® GRC l J TUBE$CONDUIT° 0 atkore FEATURES &SPECIFICATIONS Full l tri l System Protection can be installed in all occupancies and locations, including Manufactured from mild steel,Allied's Rigid Conduit is highly Class I Division 1 hazardous locations. Rigid steel conduit is resistant to damage from impact yet ductile to facilitate bending. recognized as an equipment grounding conductor in Section 250.118 of the NEC. It is listed to Underwriters Laboratories The 3/4"taper NPT threads (ANSI B1.20.1)are full cut and hot Safety Standard UL 6 and is manufactured to ANSI C80.1, galvanized after cutting. Color-coded end cap thread protectors both of which have been adopted as Federal Specifications in keep the threads clean, sharp and also provide instant trade size lieu of WWC 581. recognition. Even sizes are color-coded blue, 1/2 sizes black, and 1/4 sizes red. Kwik-Couple Rigid steel conduit is listed to UL 6 and UL 514B and is manufactured in accordance with Coatings ANSI C80.1. Kwik-Couple Rigid Steel conduit is Listed Hot-dip galvanized inside and out to provide galvanic corrosion for Concrete-tight applications. protection.Also topcoated with a compatible organic layer to protect against white rust.The inside surface is evenly coated for Installation of Rigid Metal Conduit shall be in accordance with the wire-pulling ease, even through multiple 90°bends. National Electrical Code and UL General Information card#DYIX. Master bundles conform to NEMA standard RN2. EMI Shielding Allied Rigid Steel Conduit is very effective in reducing the effects Specification Data of electromagnetic field levels for encased power distribution To specify, Rigid Steel Conduit and Kwik-Couple Rigid Steel circuits, shielding computers and other sensitive electronic Conduit include the following: Rigid Steel Conduit shall be equipment from the effects of electromagnetic interference. hot-dip galvanized and manufactured by Allied Tube&Conduit. Threads shall be hot galvanized after cutting. Rigid steel Visit www.alliedeg.com to obtain the GEMI (Grounding and conduit shall be listed to UL Safety Standard 6 by a nationally- Electro-Magnetic Interference) software analysis program. recognized testing laboratory with follow up service. It shall be manufactured in accordance with ANSI C80.1. Codes &Standards Compliance Standard Galvanized Rigid Steel Conduit produced by Allied Note: Federal specification WW-C-581, Class 1, is precision manufactured for dependable, long-lasting value Type A has been superseded by UL Standard 6, and ultimate protection for electrical conductors. Covered which has been adopted by the federal government. by article 344 of the National Electrical Code® (NEC), rigid steel conduit is highly resistant to damage from impact. It KWIK-COUPLE AVAILABLE KWi .-Couple (GRC) Trade Size 2-1/2 to 5 UL Safety Standard 6 U` Manufactured in accordance with ANSI C80.1 Trade Metric Outside Nominal Wall Approximate Bundle Weight Per Size Designator Diameter' Thickness2 100 Ft(30.5M) Quantity in mm in mm lb kg ft m 2 1/2 63 2.875 73.03 0.193 4.90 559 253.6 400 121.9 3 78 3.500 88.90 0.205 5.21 727 329.8 300 91.4 3 1/2 91 4.000 101.60 0.215 5.46 880 399.2 250 76.2 4 103 4.500 114.30 0.225 5.72 1030 467.2 200 61.0 5 129 5.563 141.30 0.245 6.22 1400 635.0 150 45.7 'Tolerances:Trade Size 2-1/2 to 5:±1% 2 For information only.Not a requirement of the UL standard. NOTE:Special orders are non-cancelable, non-returnable and 140, non-refundable 16100 S. Lathrop Ave., Harvey, IL 60426 Phone/708.339.1610 • Toll-Free/800.882.5543 www.alliedeg.com Galvanized Rigid Conduit (GRC) Couplings & Elbows neallied TUBE&CONDUIT' °,Aatkore Galvanized Rigid Conduit (GRC) Couplings Manufactured to Underwriters Laboratory Safety Standards UL 6 Manufactured in accordance with ANSI C80.1 Approximate I��__A \I Trade Metric Nominal O.D.(A)2 Length(B)' Threads Weight Per Standard Size Designator Per Inch 100 Pieces Package B in mm in mm lb kg 1/2 16 1.01 25.7 15/8 41.3 14 12 5.4 100 3/4 21 1.25 31.8 1 41/64 41.7 14 18 8.2 50 1 27 1.53 38.7 131/32 500 111/2' 30 13.6 30 1 1/4 35 1.87 47.5 2 1/32 51.6 11 1/2 37 16.8 25 1 1/2 41 2.16 54.7 2 1/16 52.4 11 1/2" 52 23.6 25 2 53 2.65 67.3 2 1/8 54.0 11 1/2 72 32.7 20 2 1/2 63 3.25 82.6 3 3/16 81.0 8 170 77.1 1 3 78 3.87 98.3 3 5/16 84.1 8 210 95.3 1 31/2 91 4.50 114.3 313/32 86.5 8 340 154.2 1 4 103 4.88 123.8 3 33/64 89.3 8 300 136.1 1 5 129 6.00 152.4 3 61/64 100.4 8 475 215.5 1 6 155 7.20 182.9 4 1/4 108.0 8 765 347.0 1 'Mimimum requirement as per UL Standard Galvanized Rigid Conduit Degree lb Listed to UL Safety Standard 6 UL Manufactured in accordance with ANSI C80.1 Approximate "-D Trade Metric Standard (Tr(A)' Offset(B)2 Straight(D)' Weight Per `/ Size Designator 100 Pieces Package A in mm in mm in mm lb kg (1- B 1/2 16 4 102 5 7/8 149 1 1/2 38 68 30.8 50 D 3/4 21 41/2 114 7 178 1 1/2 38 109 49.4 50 1 27 5 3/4 146 8 3/4 222 1 7/8 48 201 91.2 25 1 1/4 35 7 1/4 184 10 3/4 273 2 51 336 152.4 20 B 11/2 41 81/4 210 121/4 311 2 51 460 208.7 15 2 53 91/2 241 14 1/2 368 2 51 729 330.7 10 2 1/2 63 10 1/2 267 17 432 3 76 1374 623.2 1 3 78 13 330 19 5/8 498 3 1/8 79 2045 927.6 1 3 1/2 91 15 381 22 3/4 578 3 1/4 83 2860 1297.3 1 4 103 16 406 23 7/8 606 3 3/8 86 3519 1596.2 1 5 129 24 610 34 7/8 886 3 5/8 92 6942 3148.9 1 6 155 30 762 45 1/2 1156 3 3/4 95 11960 5425.1 1 'Mimimum requirement as per UL Standard 'For information only,not a requirement as per UL Standard Sizes 2 1/2(63)and larger shipped in palletized cartons or bulk. Also available in the following Degrees(60°,45°,30°,22-1/2°,15°&11-1/4°) KWIK COUPLE ELBOWS AVAILABLE by special order in Trade Size 2-1/2 to 5 ..1 non-refundable Special orders are non-cancelable, non-returnable and non-refundable 16100 S. Lathrop Ave., Harvey, IL 60426 Phone/708.339.1610 • Toll-Free/800.882.5543 www.alliedeg.carn Galvanized Rigid Conduit (GRC) Elbows n®allied TUBE&CONDUIT° ,,,..a;°,Aatkore GalvanizedRigid -Conduit 5 Degree Elbows Listed to UL Safety Standard 6 '' Manufactured in accordance with ANSI C80.1 UL Approximate I Trade Metric Standard / Radius(A)' Offset(B)2 Offset(C)2 Straight(D)' Weight Per D ' Size Designator 100 Pieces Package in mm in mm in mm in mm lb kg 1/2 16 4 102 7 178 2"7/8 73 1 1/2 38 55 24.9 50 A 3/4 21 4 1/2 114 7 7/8 200 3 1/4 83 1 1/2 38 82 37.2 50 B 1 27 5 3/4 -,146 9 5/8 244 4 102 1 7/8 48 148 67.1 25 1 1/4 35 7 1/4 184 11 1/8 283 45/8 117 2 51 232 105.2 20 D 1 1/2 41 8 1/4 210 13 1/8 333 5 3/8 137 2 51 329 149.2 15 2 53 9 1/2 241 15 3/4 400 6 1/2 165 2 51 525 238.1 10 2 1/2 63 10 1/2 267 17 1/2 445 7 1/4 184 3 76 932 422.8 1 -C 3 78 13 330 21 7/8 556 9 229 31/8 79 1515 687.2 1 3 1/2 91 15 381 26 1/8 664 10 7/8 276 3 1/4 83 2200 997.9 1 4 103 16 406 26 1/4 667 10 7/8 276 3 3/8 86 2575 1168.0 1 5 129 24 610 35 7/8 911 14 7/8 378 3 5/8 92 4783 2169.6 1 6 155 30 762 43 3/8 1102 18 457 3 3/4 95 7590 3442.8 1 1Mimimum requirement as per UL Standard 2For information only,not a requirement as per UL Standard KWIK-COUPLE ELBOWS AVAILABLE Sizes 2 1/2(63)and larger shipped in palletized cartons or bulk. Also available in the following Degrees(60°,45°,30°,22-1/2°,15°&11-1/4°) by special order in Trade Size 2-1/2 to 5 Galvanized Rigid -f n it(SRC) Large Radius 90 Degree Elbows •./ Listed to UL Safety Standard 6 ,' Manufactured in accordance with ANSI C80.1 U� Trade Metric Approximate Size Designator Radius(A) Offset(B)2 Straight(D)2 Weight Per 100 Pieces it-D in mm in mm in mm lb kg Irrt 1 27 12 305 20 5/8 524 8 5/8 219 483 219.1 1 27 15 381' 24 1/4 616 9 1/4 235 564 255.8 1 27 18 457 27 7/8 708 9 7/8 251 644 292.1 1 27° 24 610 34 5/8 879 10 5/8 270 792 359.3 ID A B 1 27 30 762 41 1041 11 279 926 420.0 1 27 36 914 46 3/4 1187 10 3/4 273 1047 474.9 . B 1 27 42 1067 54 1372 12 305 1208 547.9 1 27 48 1219 61 1/4 1556 13 1/4 337 1369 621.0 1 1/4 35 12 305 20 5/8 524 8 5/8 219 654 296.7 1 1/4 35 15` 381° 24 1/4 616 9 1/4 235 763 346.1 1 1/4 35 18 457 27 7/8 708 9 7/8 251 872 395.5 1 1/4 35 24 610 34 5/8 879 10 5/8 270 1072 486.3 11/4 35 30 762 41 1041 11 279 1254 568.8 1 1/4 35 36 914 46 3/4 1187 10 3/4 273 1417 642.8 1 1/4 35 42 1067 54 1372 12 305 1635 741.6 1 1/4 35 48 1219 61 1/4 1556 13 1/4 337 1853 840.5 'For information only,not a requirement as per UL Standard Chart continued on the next page Shipped in palletized cartons or bulk. Also available in the following Degrees(90°,60°,30°,22-1/2°,15°&11.1/4°) NOTE:Special orders are non-cancelable, non-returnable and 4..0i non-refundable 16100 S. Lathrop Ave., Harvey, IL 60426 Phone/708.339.1610 • Toil-Fees/800.882.5543 www.ailiedeg.com Pe Galvanized Rigid Conduit (GRC) Elbows alIed TUBE&CONDUIT° ,.a a atkore GalvanizedRigid Conduit (GRC) Large adios 90 Degree lour (continued) Listed UL Safety Standard 6 Manufactured in accordance with ANSI C80.1411) Trade Metric Approximate .-D Size Designator 100 Pieces A Radius(A) Offset(B)2 Straight(D)2 Weight Per R i in mm '" in mm in mm` lb kg t 1 1/2 41 12 305 20 5/8 524 8 5/8 219 789 357.9 D B 1 1/2 41 15 381 24 1/4 616 9 1/4 235 921 417.8 _. 1 1/2 41 18 457 27 7/8 708 9 7/8 251 1052 477.2 B 1 1/2 41 24 610 34 5/8 879 10 5/8 270 1293 586.5 1 1/2 41 30 762 41 1041 11 279 1512 685.8 1 1/2 41 36 914 46 3/4 1187 10 3/4 273 1710 775.7 1 1/2 41 42 1067 54 1372 12 305 1973 895.0 1 1/2 41 48 1219 61 1/4 1556 13 1/4 337 i' 2236 1014.2 2 53 15 381 241/4 616 91/4 235 1225 555.7 2 53 18 457 27 7/8 708 9 7/8 251 '' 1400 635.0 2 53 24 610 30 3/8 772 6 3/8 162 1473 668.2 2 53 30 762 41 1041 11 279 2013 913.1 2 53 36 914 46 3/4 1187 10 3/4 273 2275 1031.9 2 53 42 1067 54 1372 12 305 2625 1190.7 2 53 48 1219 61 1/4 1556 13 1/4 337 2975 1349.5 2 1/2 63 18 457 24 3/8 619 6,3/8 162 1910 866.4 2 1/2 63 24 610 31 1/8 791 7 1/8 181 2422 1098.6 2 1/2 63 30 762 37 1/2 953 7 1/2 191 2868 1310.0 2 1/2 63 36 914 44 3/4 1137 8 3/4 222 3447 1563.6 2 1/2 63 42 1067 54 1372 12 305'' 4193 1901.9 2 1/2 63 48 1219 61 1/4 1556 13 1/4 337 4752 2155.5 3 78 15 381 24 1/4 616 9 1/4 235 2545 1154.4 3 78 18 457 24 3/8 619 6 3/8 162 2484 1126.7 3 78 24 610 33 1/8 841 9 1/8 232 3393 1539.1 3 78 30 762 38 5/8 981 8 5/8 219 3892 1765.4 3 78 36 914. 46 7/8 1191 10 7/8 276 4741 2150.5 3 78 42 1067 54 1372 12 305 5453 2473.5 3 78 48 1219 60 1/4 1530 12 1/4 311 6058 2747.9 3 78 60 1524 75 7/8 1927 15 7/8 403 7634 3462.8 3 1/2 91 18 457 26 3/8 670 8 3/8 213 3300 1496.9 3 1/2 91 24 610 35 1/8 892 11 1/8 283 4400 1995.8 3 1/2 91 30>_ 762 38 1/2 978 8 1/2 216 4693 2128.7 3 1/2 91 36 914 47 1194 11 279 5757 2611.4 3 1/2 91 42 1067 54 1372 12 305 6600 2993.8 3 1/2 91 48 1219 601/4 1530 121/4 311 7333 3326.2 4 103 18 457 27 3/8 695 9'3/8 238 4034 - 1829.8 4 103 24 610 35 1/8 892 11 1/8 283 5150 2336.0 4 103 30 762 39 3/8 1000 9 3/8 238 5644 2560.1 4 103 36 914 47 1194 11 279 6738 3056.4 4 103 42 1067 ''' 54 1372 12 305 7725 3504.1 4 103 48 1219 601/4 1530 121/4 311 8583 3893.2 4 103 60 1524 75 7/8 1927 15 7/8 403 10815 4905.7 'For information only,not a requirement as per UL Standard Chart continued on the next page Shipped in palletized cartons or bulk. Also available in the following Degrees(60°,45°,30°,22-1/2°,15°&11-1/41 KWIK-COUPLE AVAILABLE Trade Size 2-1/2 to 5 by special order �� NOTE: Special orders are non-cancelable, non-returnable and non-refundable 16100 S. Lathrop Ave., Harvey, IL 60426 Phone/708.339.1610 • Toll-Free/800.882.5543 wwvr.alliedeg.com Galvanized Rigid Conduit (GRC) Elbows & Nipples n¢allied TUBE&CONDUIT° ==.== =tk atkore Galvanized :i id Conduit Large Radius 90 DegreeElbows (continued) `J Listed to UL Safety Standard 6 '' Manufactured in accordance with ANSI C80.1 UL i< D Trade Metric Approximate ((lq!(I Size Designator Radius(A) Offset 93)2 Straight(D)2 Weight Per FR 100 Pieces in mm in mm in mm lb kg B 5 129 36 914 50 3/4 1289 14 3/4 375 10033 4551.0 D 5 129 48 1219 65 1/4 1657 17 1/4 438 12833 5821.0 5 129 60 1524 75 718 1927 15 7/8 403 14700 66679 ;( B 6 155 36 914 50 3/4 1289 14 3/4 375 13187 5981.6 6 155 48 1219 65 1/4 1657 17 1/4 438 16867 7650.9 6 155 60 1524 75 7/8 1927 15 7/8 403 19320 8763.6 2For information only,not a requirement as per UL Standard Shipped in palletized cartons or bulk. Also available in the following Degrees(60°,45°,30°,22.1/2°,15°&11-1/4°) KWIK-COUPLE AVAILABLE Trade Size 2-1/2 to 5 by special order Galvanized i id Conduit ( ; Nipples Listed to UL Safety Standard 6 43 Manufactured in accordance with ANSI C80.1 Approximate Trade Metric Total Thread Threads Standard Size Designator Length(A) Length(BY Per Inch' Weight Per Padcage T T 100 Pieces B in mm in mm lb kg 1 1/2 16 (Close)1 1/8 29 0.78 19.8 14 6 2.7 25 `.1 1/2 16 1 1/2 38 0.78 19.8 14 8 3.6 25 1/2 16 2 51 0.78 19.8 14 12 5.4 25 A 1/2 16 2 1/2 64 0.78 19.8 14 15 6.8 25 1/2 16 3 76 0.78 19.8 14 19 8.6 25 1/2 16 31/2 89 0.78 19.8 14 22 10.0 25 1/2 16 4 102 0.78 19.8 14 26 11.8 25 1/2 16 5 127 0.78 19.8 14 33 15.0 25 1/2 16 6 152 0.78 19.8 _ 14 40 18.1 25 1/2 16 8 203 0.78 19.8 14 54 24.5 25 112 16 10 254 0.78 19.8 14 68 30.8 25 1/2 16 12 305 0.78 19.8 14 82 37.2 25 3/4 21 (Close)1 3/8 35 0.79 20.1 14 9 4.1 25 3/4 21 1 1/2 38 0.79 20.1 14 10 4.5 25 3/4 21 2 51 0.79 20.1 14 14 6.4 25 3/4 21 2 1/2 64 0.79 20.1 14 19 8.6 25 3/4 21 3 76 0.79 20.1 14 24 10.9 25 3/4 21 3 1/2 89 0.79 20.1 14 28 12.7 25 3/4 21 4 102 0.79 20.1 14 34 15.4 25 3/4 21 5 127 0.79 20.1 14 43 19.5 25 3/4 21 6 152 0.79 20.1 14 52 23.6 25 3/4 21 8 203 0.79 20.1 14 73 33.1 25 3/4 21 10 254 0.79 20.1 14 " 89 40.4 25 3/4 21 12 305 0.79 20.1 14 109 49.4 25 'Mimimum requirement as per UL Standard Chart continued on the next page A tolerance of minus one thread applies to Total length of Thread NOTE:Special orders are non-cancelable, non-returnable and non-refundable ild 16100 S. Lathrop Ave., Harvey, IL 60426 Phone/708.339.1610 • Toll-Free/800.882.5543 wwvw r.alliedeg.corn Galvanized Rigid Conduit (GRC) Nipples nQallled TUBE&CONDUIT° ..a .4;atkore Galvanized Rigid Conduit (GRC) N (continued) Listed to UL Safety Standard 6 '' Manufactured in accordance with ANSI C80.1 UI Approximate Trade Metric Total Thread Threads Standard Size Designator Length(A) Length(B)' Per Inch' Weight Per Package - T 100 Pieces B in mm in mm lb kg � 1 1 27 (Close) 1 1/2 38 0.98 24.9 11 1/2 16 7.3 25 1 27 2 51 0.98 24.9 11 1/2 22 10.0 25 1 27 21/2 64 0.98 24.9 111/2 28 12.7 25 A 1 27 3 76 0.98 24.9 111/2 36 16.3 25 1 27 31/2 89 0.98 24.9 111/2 43 19.5 25 1 27 4 102 0.98 24.9 11 1/2 49 22.2 25 1 27 5 127 0.98 24.9 111/2 64 29.0 25 1 27 6 152 0.98 24.9 11 1/2 78 35.4 25 1 27 8 203 0.98 24.9 11 1/2 109 49.4 25 1 27 10 254 0.98 24.9 11 1/2 138 62.6 25 1 27 12 305 -'- 0.98 24.9 111/2 166 75.3 25 1 1/4 35 (Close) 1 5/8 41 1.01 25.7 11 1/2 22 10.0 25 1 1/4 35 2 51 1.01 25.7 11 1/2 28 12.7 25 1 1/4 35 2 1/2 64 1.01 25.7 11 1/2 37 16.8 25 1 1/4 35 3 76 1.01 25.7 11 1/2 47 21.3 25 1 1/4 35 3 1/2 89 1.01 25.7 11 1/2 55 24.9 25 1 1/4 35 4 102 1.01 25.7 11 1/2 66 29.9 25 1 1/4 35 5 127 1.01 25.7 11 1/2 84 38.1 25 1 1/4 35 6 152 1.01 25.7 11 1/2 100 45.4 25 1 1/4 35 8 203 1.01 25.7 11 1/2 136 61.7 25 11/4 35 10 254 1.01 25.7 111/2' 176 79.8 40 1 1/4 35 12 305 1.01 25.7 11 1/2 216 98.0 30 1 1/2 41 (Close)1 3/4 44 1.03 26.2 11 1/2 28 12.7 25 1 1/2 41 2 51 1.03 26.2 11 1/2 34 15.4 25 11/2 41 21/2 64 1.03 26.2 111/2 44 20.0 25 1 1/2 41 3 76 1.03 26.2 11 1/2 56 25.4 25 11/2 41 31/2 89 1.03 26.2 111/2 68 30.8 25 1 1/2 41 4 102 1.03 26.2 11 1/2 80 36.3 25 1 1/2 41 5 127 1.03 26.2 11 1/2 103 46.7 25 1 1/2 41 6 152 1.03 26.2 11 1/2 122 55.3 50 1 1/2 41 8 203 1.03 26.2 11 1/2 17D 77.1 40 1 1/2 41 10 254 1.03 26.2 11 1/2 216 98.0 30 1 1/2 41 12 305 1.03 26.2 11 1/2 260 117.9 20 2 53 (Close)2 51 1.06 26.9 11 1/2 44 20.0 25 2 53 2 1/2 64 1.06 26.9 11 1/2 59 26.8 25 2 53 3 76 1.06 26.9 11 1/2 72 32.7 25 2 53 3 1/2 89 1.06 26.9 11 1/2 88 39.9 40 2 53 4 102 1.06 26.9 11 1/2 103 46.7 40 2 53 5 127 1.06 26.9 111/2 132 59.9 40 2 53 6 152 1.06 26.9 111/2 160 72.6 30 2 53 8 203 1.06 26.9 11 1/2 220 - 99.8 20 2 53 10 254 1.06 26.9 11 1/2 285 129.3 20 2 53 12 305 1.06 26.9 111/2 335 152.0 15 'Mimimum requirement as per UL Standard Chart continued on the next page A tolerance of minus one thread applies to Total length of Thread NOTE:Special orders are non-cancelable, non-returnable and non-refundable 16100 S. Lathrop Ave., Harvey, IL 60426 Phone/708.339.1610 • Toll-Free/800.882.5543 www.alliedeg.com Galvanized Rigid Conduit (GRC) Nipples -®allied TUBE&CONDUIT' a,..a;.Aatkore Satvanized Rigid Conduit (GRC) Nipples (continued) ./ Listed to UL Safety Standard 6 (110 Manufactured in accordance with ANSI C80.1 Approximate Trade Metric Total Thread Threads Standard Length(A) Weight Per Size Designator Length(B)' 1 Per Inch100 Pieces B in mm in mm lb kg 1 2 1/2 63 (Close)2 3/4 70 1.57 39.9 8 84 38.1 1 2 1/2 63 3 76 1.57 39.9 8 100 45.4 1 2-1/2 63 31/2 89 1.57 39.9 8 120 54.4 1 A Package - T 2 1/2 63 4 102 1.57 39.9 8 150 68.0 1 2 1/2 63 5 127 1.57 39.9 8 197 89.4 1 2 1/2 63 6 152 1.57 39.9 8 240 108.9 1 2 1/2 63 8 203 1.57 39.9 8 329 149.2 1 21/2 63 10 254 1.57 39.9 8 422 191.4 1 21/2 63 12 305 1.57 39.9__, 8 505 229.1 „1- 3 78 (Close)2 5/8 67 1.63 41.4 8 118 53.5 1 3 78 3 76 1.63 41.4_,, 8 130 59.0 1 3 78 3 1/2 89 1.63 41.4 8 157 71.2 1 3 78 4 102 1.63 41.4 8 200 90.7 1 3 78 5 127 1.63 41.4 8 260 117.9 1 3 78 6 152 1.63 41.4 8 300 136.1 1 3 78 8 203 1.63 41.4 8 411 186.4 1 3 78 10 254 1.63 41.4. 8 528____ 239.5 1 3 78 12 305 1.63 41.4 8 630 285.8 1 3'1/2 91 (Close)rr23/4 70 1.68 42.7 8 160 72.6 1 3 1/2 91 4 102 1.68 42.7 8 240 108.9 1 3 1/2 91 5 127 1.68 42.7 8 320 145.2 ''' 1 3 1/2 91 6 152 1.68 42.7 8 373 169.2 1 3 1/2 91 8 203 1.68 42.7 8 510 231.3 1 3 1/2 91 10 254 1.68 42.7 8 655 297.1 1 3 1/2 91 12 305 1.68 42.7 8 785 356.1 1 4 103 (Close)2 7/8 73 1.73 43.9 8 180 81.6 1 4 103 4 102 1.73 43.9 8 285 129.3 1 4 103 5 127 1.73 43.9 8 380 172.4 1 4 103 6 152 1.73 43.9 8 440 199.6 1 4 103 8 203 1.73 43.9 8 600 272.2 1 4 103 10 254 1.73 43.9 8 775 351.5 1 4 103 12 305 1.73 43.9 8 925 419.6 1 5 129 (Close)3 76 1.84 46.7 8 240 108.9 1 5 129 5 127 1.84 46.7 8 480 2177 1 5 129 6 152 1.84 46.7 : 8 - 600 272.2- 1 5 129 8 203 1.84 46.7 8 825 374.2 1 5 129 10 254 1.84 46.7 8 1055 478.5 1 5 129 12 305 1.84 46.7 8 1260 571.5 1 6 155 (Close)3 1/8 79 1.95 49.5 8 350 158.8 1 6 155 5 127 1.95 49.5 8 660 299.4 1 6 155 6 _ 152 1.95 49.5 8 820 372.0 1 6 155 8 203 1.95 49.5 8 1125 510.3 1 6 155 10 254 1.95 49.5 8 1440 653.2 1 6 155 12 305 1.95 49.5 8 1720 780.2 1 'Mimimum requirement as per UL Standard A tolerance of minus one thread applies to Total length of Thread NOTE: Special orders are non-cancelable, non-returnable and non-refundable .11 16100 S. Lathrop Ave., Harvey, IL 60426 Phone/708.339.1610 • Toil-Free/800.882.5543 www.alliedeg.com ES sealing hubs and TSC epoxy Cl. I, Div. 1 & 2, Groups C, D 5F u, Explosionproof m sealing compound Watertight See pages 124-125 for L Chico sealing compound and fiber Applications: TSC epoxy sealing ES sealing nubs are used to'. compound • Seal vertical conduit risers at switchgear t and motor control centers,sheet metal - s;ructules or cast boxes and enclosures , • Seal horizontal conduit runs at enclosures :g - •. ovhen used with TSC sealing compound a1� A two-part epoxy sealing compound flay "< ' be used to seal ES sealing hubs It 1s quick Certifications and , ;, �,� ,� and easy to measure, mix ano install. The Compliances: compound is kneaded until a un f rm color • Class I, viS ones 1 & 2, Groups C, is obtained. It is then packed around the • standard• 1203 Ordering information: conductors to effectively seal the cable. • CSA standard. C22.2 No.30 Approximate Ordering information: Female Male internal hub hub volume in Standard Standard material: size size Cat.# cubic inches carton qty. Tube size Cat.#0 • Feraloy iron alloy 1" ES31 0.65 '" 1'" ES32 0.65 10 5 oz. TSCO5 1 1/" ES53 3.20 10 1.0 cz. TSC1 Standard finish: -IA" 2-- ES64 4.90 4.0 oz. TSC4 • Electrogal�-anized 1/1" 2' ES65 4.70 2" 2/1' ES76 9.10 3' 4" ES1OB 36.00 4" 5" ES01210 95.00 6" E5014012 155.00 Note: tOss'SO sealing gasket a sd losanut separately. Typical installations: Clots I,Division Area 0 J,., Class i, O Not-Hazardous area DirJsior z . 'J _ ,% -f 0 0 around Level �� © O �0 I Class Divis on i Area Class I,D-.is on I Area . r i72 h j .rum class I,Division I 1. ES sealing hub 1. ES sealing hub 1. ES sealing hub 2. EJB junction box 2. LT connector 2. Locknut 3. UNY union 3. Locknut 3. Sealing gasket 4. EDS factory sealed control 4. Sealing gasket 4. Sheet metal station 5.Junction box structure, motor 5. EYS horizontal seal 6. UNY union control center, 6. Explosionproof motor 7. Synchronous motor panelboard,unit 8. EDS factory sealed sub-station,etc. control station 9. LT conduit Dimensions (in inches): 0 Cat.# a b c d e -b 1 ES31 1/,r 71 2 /,, I .Male ES32 1+/ '/e 2 f,a 1`, ES53 2'2 Pk3/�' 1 /,L 1'', in Hub ES64 21+ VA 3',4 1''/,, 2`/s ES65 2/_ 1.: 3 271, �� / TA I _ ES76 3' 3'/. 2 3 �`�i ES 1 U8 5/, 37, 4 /, 2 1,, 41, d @ ES01210 65,4 43: 65A- 47, 5'/a 7 Female ES014012 TA: / 7 , 57, 6' Hub Sear g hubs are approved for use in hazardous locations when Chico X fiber and Chico A sealing connpound are used to i make the seal. Sealing hubs a-e approved for no-zontal conduit cans for use in hazardous locations when used wt'n TSC --e sealing compound-order 1 oz.tube as TSC':. ()Cyder quantity of one 111 TSCOE or TOO' equals ten('01 tubes;one 1,11 TSC3 equals`'we 51 4.0 oz.tubes. Fir_T N CROUSE-HINDS SERIES sae:*Crouse-hlnds.com US.'-86 64-5A54 CAN.1-E0O-265-0502 Coovright 2o19 Eaton 123 , EYD and EZD conduit CI. I, Div. 1 & 2, Groups B, C, Do Explosionproof 5F CI. II, Div. 1, Groups E, F, G Dust-ignitionproof sealing fittings with drains Ci. II, Div. 2, Groups F, G CI. HI Applications: Standard materials: Options: EYD drain and EZD drain:and inspection • Bodes andinspection or drain covers Description Suffix sealing fittings: Feraloy iron alloy anther ductile i or: • Copper-free aluminum bodies. • Restrictpassage ofti • Closure for"rain—copper-free aluminum nipples and enclosures - SA the pa_sag gases, vapors (P or flames from one portion of the or ductile on electrical installation to another at • Small closure plug—Feraloy iron alloy Size ranges: atmospheric pressure and normal ambient and/or steel temperatures • EYD—'%:,, 4" • Drain—stainless steel • Limit explosions to the sealed off • EZD—'L" -2" • Removable nipples—steel enclosure • Prevent pre-compression or "pressure Standard finishes: piling" in conduit systems raloy iron:alloy and;trot Ili iron— Drain sealing fittings are installed in vertical electrogalvanized and aluminum acrylic conduit runs and at law points in conduit paint systems to prevent accumulation of condensate above seal. • Copper-free aluminum—natural For sealing fittings requirements. see page • Stainless steel—natural 1 1 1. • Steel—electrogalvanized Features: Ordering information: EYD and EZD drain sealing fittings include: EYD • Drain to provide continuous. automatic drainage of condensate kil • Large openings with threaded closures to 1 .71 SO provide easy access to conduit tubs`... r ; c. ,x 1 r tit making darns • Integral bushings to protect conductor insulation from damage • Taper tapped hubs :o ensure ground C . continuity EZD drain and inspection sealing fittings also ' ,,.„„„,' include. 12"-1" '/2" -1" 1'/ -4" 17l,-4" • Removable covers for periodic inspection female hub male and female hub male and of seals female hub female hub • Barrier for sealing compound easily installed after dams are made and before Approximate compound is poured Cat.# Cat.# internal Hub Cat.# Male and Cat.# Male and volume in size Female hub female hub Female hub female hub cubic inches Certifications and EYD10 EYD160 EYD11 EYD116 compliances: J«��.__ EYD2O EYD260 EYD21 EYD216 2 NEC/CEG: 1" EYD30 EYD360 EYD31 EYD316 37_ 1','4" EYD40 EYD460 EYD41 EYD416 8 EYD11-EYD101,EYD116-EYD1016 1'/2_ EYD50 EYD560 EYD51 EYD516 107: • Class I. Divisions 1 &2, Groups B, C, D 2 "EYD60 EYD660 EYD61 EYD616 220 2/,: EYD70 EYD760 EYD71 EYD716 35 • Class II, Division 1, Groups E F, G 3" EYD80 EYD860 EYD81 EYD816 57 • Class II, Division 2, Groups F, G 3!." EYD90 EYD960 EYD91 EYD916 75 • Class III 4" EYD100 EYD1060 EYD101 EYD1016 105 EYD 1-EYD 10,EYD 16-EYD 106, EZD111-EZD611 • Class I, Divisions 1 &2, Groups C. D • Class II, Division 1, Groups F,G • Class II, Division 2, Groups F, G • Class III UL standard: • UL1203 CSA standard: • C22.2 litol Sealing fittings are approved for use in hazardous Humors on y wnen Chico X fiber and Chico A.searing co ,pouna or C'-:co SpeedSeal are..see t,mare the sear. ()See Certifications and compliances sec'au-for class f catpon of each uroduct. OAvailable in coppe=free alumi:^.um. To order,add suffix'SC to ens of catalog number. 118 www.crouse-r-rnOnccm US. 866-754-54 CAN 1-800-265-0502 Cop;ng^r' 20i9Ea±en f CROUSE-HINDS a SE�IEs e EYD and EZD conduit CI. I, Div. 1 & 2, Groups C, D Explosionproof 5F to CI. II, Div. 1, Groups E, F, G Dust-ignitionproof sealing fittings with drains CI. II, Div. 2, Groups F, G Cl. III .i Ordering information Dimensions (in inches): (continued): EYD drain seal EZD with drain and Hub Turning b 0 size a b radius inspection cover 3'/ 1 : -. " 3"/. 1/ (1:: a 11" 51e 2. nzV 7 6'1, 3 ii L Turning Turning radius radius EYD'/z" - 1" EYD 1'/." -4" Approximate internal 1 With blank cover volume in Hub size Cat.# cubic inches e C 1.' b I EZD111 J t • EZD217 6 11111 1• EZD311 10 -- 1'J�" Ez[s411 11 /Ilk\ 11" EZD511 13 2" EZD611> 40 a - .4 WI a1r - 4 L y C Dotted lines show drain With drain cover cover. Full lines show blank cover EZD drain and inspection seals Hub c(drain Turnip size a b cover) radius 3 31- 21,; '/a" 4/,0 3 314 2 i',G 1" 1./4" 4-/.6 3'/ 4'/ 214 1'1- a'/ie 3'/; 4y 2"/i 2- 74 5/a 5'/ 3';c Ova tc cover oved. EA•N GROUSE HSND$ .,;: ,c odse^rods cam US 866-764- -54 CAN.1-8c0-265-0502 Covyrgnf 2019 Eaton 119 CI. I, Div. 1 & 2, Groups Bo, C, D Ex losion roof Condulet GUA conduit CI. II, Div. 1, Groups E F, G Dust-ignitionproof 3F outlet boxes with covers CI. II, Div. 2, Groups F, G Raintight CI. III Wet Locations NEMA 3, 4, 7CD, 9EFG Applications: Standard finishes: Accessories (ordered GUA conduit outlet boxes are installed within • Feraloy iron alloy—e!ectroga!vanizeo and separately): hazardous area conduit systems to: aluminum acr li paint • Protect conductors in?breaded rigid • Aluminum—natural Description Cat.# conduit • Replacement ground screw GSP1 Options: • Act as pull and splice boxes Description Suffix • Connect lengths of conduit • Bodies—copper-free aluminum SA • Change conduit direction • Covers—Feraloy!rcn alloy WOD • Prov:de access to conductors for maintenance and future system changes EIRC,r.gaivo'nizec and alu nern acrylic paint*MIS"; IS"; Ac t • GUA Form 6 i iith. cover opening) VW A.S• as mounting outlets for fixture_ ✓ah appropriate covers` d s,adie , -.ona vev,,ing r,,;oar:,- • Act as sealing fittings(with appropriate • Corro-free epoxy powder coat S752 covers) • To order box less cover Add'0'to end of catalog number Features: • Factory installed terminal blocks mounted to DIN rail DIN12-122 see page 55 far ' gtnfo,rnaton GUT•,condo t coxes have: • Factory,nstalled terminal blocks d redly mounted to cutlet box TB14-112 • Neoprene c-ring standard to meet NEMA 4 C page 56 o O •ry"rr ,r �atior,. requirements Note: lhe assemblea wi-h sealing type :JJ '.a ou ie boxes provide ide i,o r <Jin. -ill in hazardous • Cast ears on cover topermit easy removal p areas .,L,S ._ Class ,.,r„ups -arid Class If Seals be rc.aar ..her,,crizcntal or vertical and tightening Use Chi,i A seal _::'v-_und,.Chico ho_edSea'cnly Cor.i-ju::t.. splice,;J,.,dare,,O ust ,.:i be made in encbs,i,es where sealing co J is -is;33 per N_.,. • Internal green around screw#8 • Four standard mounting pads except for Ordering information: boxes with bottom hubs • Threaded cover openings GUA GUAR • Ten different huh arrangements • Taper threaded hubs to provide grounding continuity ,. `/ • Smooth integral hub bushing p-ateca '.°' conductor insulation when pulling • Surface covers furnished with boxes • Sealing covers, dome covers and fixture Cover Cover hanger covers are available Hub size opening dia. Cat.# Hub size opening dia. Cat.# • Cover threads are 12 pitch standard; 16 GUA14 GUAB140 pitch on select aluminum shaves and '/.° 2 GUA24 'I," 2" GUAB24 sizes 3" GUA16 3` GUAB160 ,4 %-„ 3" GUA260 ' ' „ 3` GUAB260 Certifications and 1" GUA36 3" GUAB360 17.1„ 3'/-� GUA47 1'.7,- 3�'/s„ GUAB470 compliances: 1/`," 5' GUA59 1;2„ 5" GUAB590 NEC/CEC: 2" 5" GUAB690 • Class I, Divisions 1 &2, Groups BO, C, D GUAC • Class II, Division 1, Groups E, F, G , , ,, GUAD • Class II, Division 2, Groups F, G „, • Class 111 - UL standard: ` : ,::,a s, h x`s € ANSI standard: • C33.27 Cover CSA standard: Hub size opening dia. Cat.# Cover • C22,2 No.30 /> GUAC140 Hub size opening dia. Cat.# I., 2" GUAC240 '/2 z GUAD14 Environmental ratings: ,. 3 GUAC160 '_" 2'" GUAD24 • NEMA/EEMAC 3,4 /•" 3" GUAC260 3' GUAD16 1" 3" GUAC360 74" 3`. GUAD26O 1'/,. 3'J.. GUAC470 1" 3., GUAD360 Standard materials: 17, GUAC490 1/"" 5., GUAD49 • Bodies—Feraloy iron alloy 1'%2" b" GUAC590 2 ., GUAC690 i • Covers—CC peer free aluminum Ow,en ordered with suffix SA are listed for Class I,Divisions 1&2,Groups B,C and D Class II,Division 1,Croups E,F,G and Gass III. Covers have 16 010 threads. ()Available in copper-free aluminum. To Dicer,add s.;ff x'SA.' 52 .evdve.crouse-e::nds.com US:"'-86a-764-5454 CAN.1-800-265-0502 Copyright' 2019 Eaton EoT•N CROUSE-HINDS Condulet GUA conduit Cl. I, Div. 1 & 2, Groups Be, C, D Explosionproof 3F w Cl. II, Div. 1, Groups E, F, G Dust-ignitionproof ,1 outlet boxes with covers CI. II, Div. 2, Groups F, G Raintight Cl. III Wet Locations NEMIA 3, 4, 7CD, 9EFG Ordering information (continued): GUAL GUAN GUAT Cover Cover Cover Hub size opening dia. Cat.# Hub size opening dia. Cat.# Hub size opening dia. Cat.# 2" GUAL140 '." ::`, GUAN14 ,/,';" �,' GUAT14 ' f,„ 2„ GUAL240 2 GUAT240 ,,3" GUAL16e , GUAN24 GUAN16 3" GUAT16e r� 1<" 3„ GUAL26e 't,," 3" GUAN26 ,II 3.' GUAT26e 1" 3` GUAL36e 1` 3" GUAN36 1" 3" GUAT36e 1/ 3'�:" GUAL470 1 is"" 3`;�t,. GUAN47 1"' 3;1," GUAT37 1 i•' GUAL49e 1 i" 5'" GUAN59 1/_" ' GUAT470 1'V," 5" GUAL59e 2" 5' GUAN6S 1/" 5^ GUAT49e 2" GUAL690 1';" 5` GUAT59e 2" 5"'' GUAT69e GUAX GUAM GUAW „ Z Cover Cover Cover Hub size opening dia. Cat.# Hub size opening dia. Cat.# Hub size opening dia. Cat.# 2' GUAX14 2" GUAM14 GUAW14 jc`" 2'" '' GUAX24 ''' 2" GUA 24 :. /"...... 2" GUAW240 3' GUAX16e 3 GUAM16 //" 3" GUAW16 1" 3' GUAX26e „ 3 GUAM26 I" 3,, GUAW26e 1" 3" GUAX36e 1" 3' GUAM36 1" 3`,/." GUAX370 1 1," 3/" GUAM47 ;" :''" GUAX470 2" 5" GUAM69 1'�i, 1 7.„ 5" GUAX49e >I 5` GUAX59e 2" 5` GUAX69e eVvnen o d_r_d with suffix'SA'are listed for Class I.Divisions 1 &2,Groups B,C and D,Class II,Division 1,Groups E,F,G and Class Ill. Covers have 6 pitc".threads. OAva.lable In copper=ree aluminum. To order,add suffix'SA.' * GROUSE-HINDS n r SERIES wvwv,',c-ouse-:^ninds.corn S."-86 ;64-51_4 CAN; 8C0-26505.2 i,c:osrighY. 2.:1„Eaton 53 Condulet GUA conduit a I, Div. 1 & 2, Groups Bo, C, D Explosionproof 3F c., a II, Div. 1, Groups E, F, G Dust-ignitionproof outlet boxes with covers Cl. II, Div. 2, Groups F, G Raintight Cl. III Wet Locations NEMA 3, 4, 7CD, 9EFG \....1 Dimensions (in inches): GUA, GUAD, GUAM, GUAW, GUAX - e -- S.Ja Cat.# a b c d ` 1- , I i , # . 14 : ''emtra '' 4 - PIT4 . 1 - ' ' I k ' '''' r;---:'' H b 2145 2 12 2 2 74 --,1- 1 w 1- .L.--l-- i 1 ' 'pas d d fw,. ":_-_+_a' ' , . ,,, .......esr,__ .40#., "__.t.. 26 372 2 2'/Ic. 7,..wi e 36 ,„ s):, 2si., TA, 7, --- a — ' 47 47. ,; , ., 2-1, 49 4/., 431.; ,,-----., 1/2 j\,,..•--\,...,.__ ,,,,...‘7' y , ', , Dimension'e' Hub size length 1- 174' 1 J GUAB only All others GUAC, GUAT GUAN GUAB, GUAL Cat.# a b c d Cat.# a b c d Cat.# a b c d 24 2/ 2 2 ',/... 24 Th 27,e 2/ I 24 272 2': TA, '14 16 3 I: 2 2/c .A 16 3,I- 2 2/6 :". 16 3/,. 2 2 26 3 1, 2 271, ',4, 26 3'/, 2 2/,; 3/, 26 37, 2 21 hc 36 3 l, 2/lc 27:s: ,'s 37 4' 2',/,'; 211 'is 47 4'/- 2-13 2"../z. ly,-.2 47 4'/4 2-,lic 25/e 1^1r 47 4/- 27E. 2'/: 1r.,'..; 49 51, 4',/, 4j/1F 11r, 69 5/,. 4/..:. 41, 1.12 59 5/.1 4/v. 4/,,, 1'ir 59 57 4'ir 41, 1 k. 69 574 47 E 17, 69 57. 4732 481,c 17? • Isd liCtv'hen ordered wits sdfhz'SA'we Izted for Class I,Dhas.ons 1&2,Groups B,C and 1:,) Class II,Llvision 1.Groups E,F,G and Class III. Covers have 16 p tch dr-eads. 54 www.crouse-..-•nos.com US, l-866-764-5454 CAN, l-80G-265-0502 .:opyrig^t- 20'9 Eaton E1T•N CROUSE-HINDSSEF • Condulet GUA conduit 3F w outlet boxes Covers and accessories Applications: Ordering information: Threaded covers, cano'cies and extensions are used: GUA threaded extension Sealing cover • To prizivioe a seal in na:ard us areas ,,,,- 0 (sealing cover); see note below . • To mount pendant lighting fixtures such 1 �'� as EVA series (fixture canopy) � �� � r • To mount EVA pendant lighting fixtures on cover which is then screwed Into outlet box without Twisting conductors(union hub cover) Cover opening die. Ext.depth Cat.# Cover • To mount pendant lighting fixtures on opening dia. Thread pitch Cat.# 1.'° GUA0631 cover which is then screwed into outlet 2" 12 GUA041 box as above, for wiring after fixture stem 3" 12 GUA062 is installed (nipple cover) 3" 16 GUA062 GEO • To provide means of increasing outlet box o-. J 12 GUA072 depth (threaded extension) C) _:•_,. 12 GUA092 Features: Nipple cover • Surface covers are supplied with GUA Cat.# boxes Replacement GUA cover opening o-ring gasket T� • Sealing cover has removable plug for filling enclosure with sealing compound 2 GASK1713 atter installation,sealing cover meets 3' GASK1151 40% fill requirement of IncNEC; see rote ��'„` GASK9259 belo,,,v • Fixture canopy has a threaded cover in its side to provide access for mak:.ing Surface cover Cover Fixt. splices or taps;fixture wit':. its conduit opening stem Thread V stem and canopy can be assembled and dia. size pitch Cat.# wired before installation arid conductors ix 3" 12 GUA0672 can be spliced in canopy after it has been e, screwed into the body ��s Fixture cover • Cover threads are 12 pitch unless otherwise specified Union hub type Cover Thread Standard materials: opening dia. pitch Cat.# 2„ • Surface and dome covers, union hub 11 GUAt)s covers, nipple covers—copper free 3" 16 GUA06 GEO ' aluminum 3`%' 12 GUA07 • Sealing covers,fixture canopies,threaded 5" 12 GUA09 extensions—Feraloy iron alloy 5" 16 GUA09 GBO .. '' Cover Fixt. Standard finishes: Dome cover opening stem Thread dia. size pitch Cat.# • Aluminum—natural 3" 14" 12 GUA0687 • Feraloy iron alloy—electro galvanized and aluminum acrylic paint Fixture canopy Options: Description Suffix • Corro-free epoxy powder coat S752 c • Iron surface cover WOD Z� ': Cover opening Ext. Thread r „, Size ranges: dia. depth pitch Cat.# • Fixture stems—1" 2" 2" 12 GUA047 • Bodyopenings enings—2" to 5' 3" 2" 12 GUAos7 2" 12 GUA077 Cover Fixt. Note GnuDeuth oi.seal no comp.:,no, body—List :is`v f�' 4" 12 GUA0716 opening stem Thread `/ eq me as NECoect en 50 5(C:i Splices 5.. 4" 12 GUA514 dia. size pitch Cat.# an.,tabs In seal' g fittings are prohibited by NEC. 5" 10" 12 GUA5110 3" 12 GUA068 OGUA covers wile suffix'GB'arc used with Group E.rated GUA aluminum oodles Identified with symbols C0 or 00 on pages 52-53. E AT•N CROUSE-HINDSERIS ES wee•:w.crnuse-ninds.com US.':-866-764-5454 CAN.1-800-2e5-0502 Couyrigh' 2019 Eaton 55 .. Condulet GUA conduit 3F th outlet boxes Factory installed terminal block ordering guide • Ordering information: DIN rail mounted terminal blocks Electrical specifications: 30A, 150V, AWG 26-10 Cat.# Description DIN rail mounted,2 terminal blocks DIN12 GUA.{shapes L,T.Xi ., orm C &9 c0 ei diameter openings 9�, ` , DIN rail mounted,3 terminal blocks 4v ��� ::: GUA(shapes C•,l„T,Xj Form 4,6,7&9 cover diameter openings JIP,rail mounted,4 terminal blocks GUA(shape L,T, Form 6,, &P cover diam,.er open inc„, DIN rail mounted,6 terminal blocks , DIN16 GUA(shapes C,L,T,X),GUAN26 Form 6,7&9 cover diameter openings '-'"*04 a „ DIN rail mounted,8 terminal blocks DIN18 GUA(shapes C,L.T X) Form 7&9 cover diameter opening DIN rail mounted,12 terminal blocks DIN112 GUA.(shapes C,L.T,X( Form 9 cover diameter opening Direct mounted terminal blocks Electrical specifications: `/ 30A, 300V, AWG 26-10 .''' Cat.# Description Direct mounted terminal block,4 poles T814 GUA(shapes C,L,T,}:i , Form 6,7&9 cover diameter openings Direct mounted terminal block,6 poles Ts16 Gt1A shapes C,L,T,Xjill Form 6,7&9 cover diameter openings ? Direct mounted terminal block,8 poles , ,' TB18 GUA(shapes L,I.X) ;- Form 7&9 cover diameter opening Direct mounted terminal block,12 poles ek'....1ii(iiiii' TB112 GUA(shapes C.L,T.X( Form 9 cover diameter opening , • CROUSE-HINDS 56 wvww.crouse-:^.nos.com US.1-866-764-5454 CAN. 1-800-265-0502 Copyright' 20i9 Eaton SERIES Condulet GUA conduit CI. I, Div. 1 & 2, Groups C, D Explosionproof 3F ,,,, Cl. II, Div. 1, Groups E, F, G Dust-ignitionproof outlet boxes with covers — Cl. II, Div. 2, Groups F, G Raintight Cl. HI Wet Locations stainless steel NEMA 3, 4X Applications: Certifications and Accessories (ordered G..IA.conduit o�tiet boxes are installed compliances: separately): within hazardous area conduit systems to: NEC/GEC: Description Cat.# • Protect conductors in threaded rigid conduit • Class I, Divisions 1 . 2, Groups C., D • o_" to 'ij" reducer RDU303029 • Act as pull and splice boxes • Class II, Division , Groups E, F, G Se Sector,41_for more infor.rnaton • Connectlengths c. conduit • Class il. Division 2. Groups F, G • Change conduit direction • Class III • Provide access to conductors for UL standard: maintenance and future system changes • UL1203 ANSI standard: Features: • C33.27 GUA conduit boxes have: CSA standard: ?2 • .2 ;0 • Neoprene o-ring standard to meet NNEMA �o. . 4X requirements Environmental ratings: • Cast ears on cover to 'e,- removal • NEMA/EEMAC I=., "'"'dt easy _: .r,�C�('`v�.=i 3 4X and tightening • Internal green ground screw#10 Ordering information: • Threaded cover openings • Five different hub arrangements GUAC GUAX • Taper Threaded hubs to p •ide grounding continuity • Smootn integral hub busning protects f I z � conductor Insulation who pulling �. • Surface covers furnished with boxes • Cover threads are 12 pitch ram Stainless steel benefits: • Self-healing properties help reduce the Cover Cover penetration of rust/corrosion and eliminate Hub size opening dia. Cat.# Hub size opening dia. Cat.# damage to the fitting 3' GUAC26 SS " 3" GUAX26 SS 1" 3" GUAC36 SS 1" 3" GUAX36 SS • Retain strength n extreme heat and extreme cold conditions • Surface is easy to maintain and keep clean GUAL GUAT • Easy cleaning capabilities make these fittings perfect for foodprocessingand } other hygienic areas where wash downs are common • Superior strength and durability greatly gi. reduce replacement—this will lower your total cost of ownership and increase your return on investment • Do not require harsh envi,ronment- damaging cleaners to keep them look'ng Cover Cover Hub size opening dia. Cat.# Hub size opening dia. Cat.# like new 3" GUAL26 SS sC' 3" GUAT26 SS 1" 3" GUAL36 SS 1" 3" GUAT36 SS Standard material: • Bodies and covers—316 stainless steel GUAB m 3 u Cover Hub size opening dia. Cat.# 3" GUAB26 SS 1" 3" GUAB36 SS E=T•N GROUSE HS(DS �,.,U_,w.c'o -hinds.ccm US.'-866-764-5.54 CAN. 8 v 295-05n2 cyrigh' 2019Eaton l57 Condulet GUA conduit CI. I, Div. 1 & 2, Groups C, D Explosionproof 3F • M CI. II, Div. 1, Groups E, F, G Dust-ignitionproof outlet boxes with covers — CI. II, Div. 2, Groups F, G Raintight Cl. III Wet Locations stainless steel NEMA 3, 4X Dimensions (in inches): a a --{ Cat.# a b c d e e e e--- GU.A.B26 SS 3.60 211 1.93 UI 0.78 d o GUA 36 SS 3.63 2.11 1293 0.88 0.97 GUA`26 SS 3.6] 2.11 1.93 0.66 3.78 e 3 A 3C SS 3.60 2.'1 1.93 0.88 0.97 SUAX26 SS 3 60 2"1 1.93 0.66 0.78 o-I r G.,Ax36 SS 3.60 2.11 1,.93 0'88 0,97 A\ r- ) / \ N GUAB Only All Others assi Ci A� N CROUSE-HINDS ��3 •.v:�ave.crouse-h naacom US:`:-85E-'64-545A CAN: 1-800-2E5-0502 Cop;ngnT' 209 Eaten - � SERIES Condulet GUR conduit Cl. I, Div. 1 & 2, Groups C, D Explosionproof 3F CI. II, Div. 1, Groups E, F, G Dust-ignitionproof „ outlet boxes with covers CI. II, Div. 2, Groups F, G Raintight CI. III Wet Locations NEMA 4 Applications: Fs conduit outlet boxes are installed within hazardous areas' ▪ protect conductors s n threaded rigid conduit ':cam • To act as put and splice boxes • To connect lengths of conduit � • To provide access to conductors for maintenance and future system changes • g charge conduit dire. :ior: • `f':then.Space is limited, such as underneath gasoline pumps T � } 3 Features: (R outlet boxesfeature: < �.'. • Neoprene o-ring standard in cover to meet NEMA 4/UL Type 4 40,-. n l� requirements • Internal green ground screw#10 L •'' • • • Five standard hubs with three pipe plugs included • Threaded cover opening • Recesses in cover to assist in cover tightening and removal Ordering information: • Smooth, integral hub bushing to protect conductor Insulation when pulling Hub size Cat.# • Compact design for conned spaces GUR1 • UL and cUL Listed 1 GUR2 GUR3 • Optional all-aluminum construction Dimensions (in inches): Certifications and compliances: NEC/CEC: --26g' - • Class I, Divisions 1 &2. Groups C, D —, too" • Class II, Division 1, Groups E, F, G • Class Ill • • Zones 1 &2r t UL standard: \\\ • UL1203 fit 312 I 4 CSA standard: • Its • cUL to CSA.standard C222 No. 30 :. I Environmental rating: � � • • NEN1A 4 Standard materials: • Bodies-Feraloy iron alloy • Covers—copper-free aluminum Standard finishes: • Feraloy iron alloy—electroaalvanized with aluminum acrylic paint • Aluminum—natural Options: Description Suffix • Bodies—copper-free aluminum SA Accessories (ordered separately): Description Cat.# • Replacement gasket GASK1801 E=T•N CROUSE HSND$ ;,,,•c o.. e-hinds.ccm US?-866 64-5454 CAN: -8 o-265-0502 Cooyrigh:' 2019 Eaton 59 Condulet OE conduit CI. I, Div. 1 & 2, Groups C, D Explosionproof 3F Ci. II, Div. 1, Groups E, F, G Dust-ignitionproof bodies with covers Cl. II, Div. 2, Groups F, G CI- III NEMA 7CD, 9EFG Applications: Ordering information: OE conduit bodies are installed in conduit systems within hazardous areas to: OEC OELB • Protect conductors in threaded rigid 4 conduit • Act as pulling and splice fittings %;*: ll . '` b•,„ • Interconnect lengths of conduit • Change direction of conduit «• ` • Provide access for maintenance and future system changes Features: Hub size Cat.# Hub size Cat.# OE conduit outlet bodies have. "., ,e, OELB1 • Taper threaded hubs for ground ort rutty 4,, OEC1 e' OELB2 • Smooth integral hub bushings to protect 1" OEC3 SA OELB3 SA conductor insulation- when pulling • Five different hub arrangements OELL OELR • Accurately machined body vvith blind tapped screw holes • Most compact design c all hazardous „-: area outlet bodies tti, . Certifications and , ��+ °�compliances: NEC/CEC: • Class I, Divisions 1 &2, Groups C, D Hub size Cat.# Hub size Cat.# , • Class II, Division 1, Groups E, F, G ` OELL1 C OELR1 v • Class II, Division 2, Groups F; G V,"` OELL2 1-` OELR2 1" OELL3 SA OELR3 SA • Class III UL standard: OET • UL1202 r CSA standard: • C22.2 No.30 Standard materials: _4 • Feraloy iron alloy( ' and fittings) • Copper-free aluminum 4 itt.mgsl 1 lf Hub size Cat.# Standard finish: OET1 • Electrogalvanized j," OET2 1" OET3 SA Options: Description Suffix Dimensions (in inches): • Corro-free epoxy powder coat S752 e , Size ranges: l g • Hub— / " to 1 " �_ b 1 d I- -- a ----- d I a e-- Hub size a b c de f ' V /a" A't%'' 1/s 271 ''Is A '14 E a. CROUSE-HINDS SER!ES ,.,\AA.-.crouse,-Inds corn ILS --866-764-545= CF-N:1-8CD-265-0502 Ccoyngh 2015 E 69 &() -22-c\D -27 (AMP ( (izs'A) els50 ( 06/9 / W LAY? EL UP) 00 � (3 c nrce) (-z t s �2 i i\IP) c rs-- ZCL�IJ . �OM /lAL $ �C-,bflt2-0 t N�•J r (De efielfa / (0> �li�j' AWED CONSULTING ENGINEERING SERVICES KDI September 20,2018 17 Ivaloo Street Somerville,MA 02143 Subject: Yarmouth Commons Ground Connections Attention: Mr.William Chalfant Mr. Chalfont, At the subject project it is acceptable to use a grounding clamp connector as listed for the purpose served in lieu of an exothermically welded connection. Sincerely, Amis!Patel,P.E. wwwalliedconsulting.net 235 Littleton Road.Unit 5 151 Cavan Street 29 West Broad Street,Unit 2 Westford,MA 01886 Warwick.R102888 Pawcatuck,CT 06379 978.443.7888 401.461.7888 860.506.7888 KHALSA DESIGN INCORPORATED Architects & Engineers , ,i+f ntt I t KHALSA TO: Mark Grylls DATE: 03-13-19 Yarmouth Building Commissioner 1146 Route 28 South Yarmouth,MA 02664 FROM: Khalsa Design, Inc. 17 Ivaloo Street Suite 400 Somerville, MA 02143 RE: Yarmouth Commons—Odor Control Room Dear Mr.Grylls, I am writing you to provide clarity on the Odor Control Room within the Waste Water Treatment building at Yarmouth Commons located at 881 Routed 28 in Yarmouth Massachusetts. The Odor Control Room is classified as Hazard, Class 1, Division 1. This classification is due to the presence of the Carbon filter within the room. As a result of this classification the room needs to have a 3-Hr Rating to protect itself from the surrounding structure. This rating is being accomplished through a combination of Shaft-Liner panels on the interior of the interior and exterior walls. Additionally, the ceiling is being treated with 3-Hr rated intumescent paint. The use of the intumescent paint was driven by the clearances needed above the Carbon canister,using shaft-wall in this location would not have worked. The door to this will be a 3-Hr rated door to fully enclose the room in 3-hour protection. This room also requires an ERV within it to provide a minimum of 6 air changes per hour. If you have any questions about this,please feel free to give me a call. Sincerely, Will Chalfant,Project Manager-Khalsa Design, Inc. CC: File