HomeMy WebLinkAboutBlde-19-006459 Commonwealth of Official Use Only E Massachusetts Permit No. BLDE-19-006459 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date•5/15/2019 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to pc rm the electrical work d be w. Location(Street&Number) 4 TEMPLETON PL At-jj( (J t ( A CoSc Owner or Tenant J Telephone No. Owner's Address P , , Is this permit in conjunction with a building permit? ,Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system.(16 Panels) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatine Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Eauivalent No.of Water KW No.of No.of Data Wiring: Heaters Siens Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Eauivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: LLOYD R SMITH Licensee: Lloyd R Smith Signature LIC.NO.: 15688 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:30 1ST ST, MELROSE MA 021764010 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 tqie 6 f [q 6(-aehlY 644 `_ L.ommonweatth of �aladdaehusetts LI!UUC!U v I useniy r _ `/�, -' t Permit No.ct -`O i -- �I .--�cc��lepartment of gire Serviced k BOARD OF FIRE PREVENTION REGULATIONS [Rev.Occupancy y and Fee Checked �'"� � (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC).527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: _24 iLM9 City or Town of: yrsArtko,j--\- ___., To the Inspec or of Wires: By this application the undersignedgives notice of his or her intention to perform the electrical work described below. Location (Street&Number) C -7S)\ Parcel ID: Owner or Tenant VC' l d-\ ,C1 Telephone No. 5T -2()-21 Al Owner's Address 500,t CAS CLIME-. Is this permit in conjunction with a building permit? Yes/ No (Check Appropriate Box) Purpose of Building D wer\v('\ T Utility Authorization No. Existing Service /OD Amps t / Zi.ip Volts Overhead Undgrd No.of Meters New Service Amps / Volts Overhead/ Undgrd n No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: in rhllC ('irN 04 ma iCi\44 .r 0"kOli`str,tzC.. ,ScACt( kS\1S--em. 1 (0 ' lU iS ., Completion of the following table may he waived by the Inspector of Wires. `44- N .of Recessed Luminaires No.of Ceil.-Susp.(Paddle) Fans No.of Total Transformers KVA . N .of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above In- No.of Emergency Lighting ,� _ & grnd. ❑ grnd. ❑ Battery Units 1 +' No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones C_ : N .of Switches No.of Gas Burners No Inittiating Devices Nb.of Ranges No.of Air Cond. Total No.of AlertingDevices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection __ _ No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water No.of No.of KW Heaters Data Wiring: Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: Pq j t,,l_i I. 9 v (When required by municipal policy.) Work to Start: L I I L1(10) Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE CO GE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE BOND ❑ OTHER ❑ (Specify:) I certify, under the pains and penalties of perjury,that the information on this application i• rue and complete. FIRM NAME: V'J;A c S€)\G'C �e,\Jtt C 1 iJ-C. LIC.NO.: Licensee: L) d.- Son k Signature i...044 Z ' I,,t l LIC. NO.: ) �� (If applicable enter "e, t"in the lice •e nurgber•line.) •�+ rsus.Tel.No.:1 I !-7"C12C3 Address: 2�U u1tCfi.� c °A �''n't Q I WC Alt.Tel.No.:3W-2{P-gtri *Per M.G.L. c. 147,s. 57-61,security work requires Department of Publit Safety"S"License: Lic. No. OWNER'S INSURANCE WAIVER: [am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below, I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE:$ .1UR1SDICTIONACNOTES: GOVERNING CODES 1 ALL WORK SHALL CONFORM TO THE FOLLOWING CODES I 1. 2015 INTERNATIONAL RESIDENTIAL CODE 2. 2015 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION a. 2017 NATIONAL ELECTRICAL CODE b. ANY OTHER LOCAL AMENDMENTS SHEET INDEX: COVER SHEET PV 1.0-SITE PLAN • S 1.0-MOUNT DETAILS E 1.0-ELECTRICAL DIAGRAM E 2.0-ELECTRICAL NOTES E 3.0-WARNING LABELS E 4.0-WARNING LABEL LOCATIONS GENERAL ELECTRICAL NOTES: GENERAL STRUCTURAL NOTES: 1. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL a. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING f M,,, MEANS DESIGNED AND LISTED FOR SUCH USE.FOR ROOF-MOUNTED THE ROCK-IT SYSTEM BY ECOFASTEN.THE MOUNTING FEET ARE TO BE m Lr'1 1/2 SYSTEMS,WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF SPACED AS SHOWN IN THE DETAILS,AND MUST BE STAGGERED TO 9 .T/f, THE ROOF SURFACE. ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 7 2. ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE b. UNLESS NOTED OTHERWISE,MOUNTING ANCHORS SHALL BE 516'LAG N. CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2.1"PENETRATION INTO ROOF FRAMING. 0 Z 3. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE c. THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. 10 " 4. RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE d. ROOF LIVE LOAD=20 psf TYPICAL,0 psf UNDER NEW PV SYSTEM. INVERTER.RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCEe. GROUND SNOW LOAD=30 psf VOLTAGE. f. WIND SPEED=140 mph / '\ �j 5. SEE'E 1.0 AND"E 2.0 FOR DIAGRAMS,CALCULATIONS,SCHEDULE AND g. EXPOSURE CATEGORY=B VI V I n}1.S o I a r SPECIFICATIONS. 1800 ASHTON BLVD.LEHI,UT,84043 4 Tenlpletnn Place 1.877.404.4129 MA LICENSE: HIC-170848, ME-15688A,SS-002342 PHOTOVOLTAIC SYSTEM SPECIFICATIONS: DA COSTA RESIDENCE I 4 TEMPLETON PL SYSTEM SIZE-5.040kW DC 3.800kW AC WEST YARMOUTH,MA,02673-1537 ' UTILITY ACCOUNT#:1430 638 0024 o MODULE TYPE&AMOUNT-(16)Jinko Solar JKM310M-60BL WITH 16 SolarEdge P320 OPTIMIZERS \_--UTILITY A 143 -- j v MODULE DIMENSIONS UWIH 66.34"/39.37"/1.26" ( ) SERVICE A S-6110393 INVERTER-(1)SolarEdge Technologies SE3800H-US000BNC4 REGIONAL COVER INTERCONNECTION METHOD-SUPPLY TAP OPERATING CENTER:MA 53 , DRRAE:5. C _ SHEET k DRAWN BY:CHARLSTON _.. 'CALLEJO PV STRING(S): jt00F SEC I IONS) SYSTEM LEGEND 1 SLOPE-30 4 TEMPLETON PL #1)i6 MODULES AZIMUTH - MATERIAL- PV SYSTEM SIZE: FRONT OF HOUSE. OMPOSITION SHINGLE NEW 5.040kW DC I 3.800kW AC W SLOPE-30 EXISTING INTERIOR MAIN SERVICE PANEL TIED AZIMUTH-80 II TO UTILITY METER#2285430. MATERIAL- COMPOSITION SHINGLE fl NEW SMART PRODUCTION METER.LOCATED P WITHIN ID OF MSP. ® NEW PV SYSTEM AC DISCONNECT. LOCATED WITHIN 101 OF MSP. © n EXISTING UTILITY METER: I3a #22I85430 1 NEW PV SYSTEM INVERTER'.SolerEdge Technologies / I SE16 NEW U JINKO 4 (RSD EW W-60B 16 NEW JINKO SOLAR JKM31OMEOBL MODULES. NEW SOLAR EDGE P320 OPTIMIZERS,MOUNTED OF EACH MODULE. �/�/, NEW PV COND ON THE UIT RUN.*SEE EE1.0 CONDUIT SCHEDULEj % % % -NEW JUNCTION IBOX.(MOUNTED TO PV MODULE) RUN A Alt /i."V// o ® -, 0 _ , vivint.Solar 1.877.404.4129 DA COSTA RESIDENCE 4 TEMPLETON PL WEST YARMOUTH,MA,02673-1537 UTILITY ACCOUNT#:1430 638 0024 SITE PLAN SERVICER I10393A OPERATING CENTER MA-03 PV 1 .0 DATE'.5.9.2019 SCALE:1/8"=1 r-0" DRAWN BY:CHARLSTON _- —. — — — ----------- ----------------- ALL - -- MOUNTING LEGEND y` P 2•• COMP SHINGLES � ROCK-R COUPLING y'i U'''"Ve•r TIT \ MID CLAMP rrK sxr` ' ''e*: ,{N., rROCK-ITCOUPLING •gtt.• .. p:; t�:4it,:q MID CLAMP Pa' - �ent'S'�� '� ROCK-IT COUPLING © 1 .5h 4� },iier.4'*: y. MID CLAMP1117 t. �-T "` - 50 l( r ,�fky.4'T% 1yROCK-IT COUPLING SHELF Tr fr ROCK-IT �I, 1 k ROCK-IT SLIDE SHIP LAP ��/�■���` I,4, PEDESTAL METAL FLASHING / r ROCK-IT METAL (INSTALLED PER MANUFACTURES INSTRUCTIONS)TIE PLATE - 6/16'zt 1/2" COUPLING SHELF /- B/18"%3/6" `-' FLASHING HEX FLANGE BOLT HEX FLANGE BOLT MI ISOMETRIC VIEW SIDE VEW 300 SERIES SS ISOMETRIC VIEW 300 SERIES SS Ir�'� / COMP SHINGLES `t f SS LAG SCREW .- TORQUE=1332 FT-LBS. � � SIDE VIEW 1 8 ILSCO SGB-4 GROUNDING LUGS (788.) (2 . 00- 1 ROCK-IT MOUNT $1O NOTTU G4E ULLISTNO FOR ECOFASTE„2703 2 ROCK-IT COUPLING ASSEMBLY S 1.0 NOT TO SCALE WEIGHT. 236 S 1..0 NOT TO SCALE TOP VIEW CLAMP+ATTACHMENT CLAMP•ATTACHMENT COUPLING I I PERMITTED COUPLING 7 1 CANTILEVER U3 OR LESS CLAMP SPACING ANDSCAPE=MAX 72"(6') COUPLING PORCLAMPMAX 64'(5'4') I't'I I"'i RAFTER MODULE III ROCK-IT SLIDE MODULE METAL I'',II'11I MODULE FLASHING r EPDM BONDED WASHER 11111 RAFTER FORMS WATERTIGHT SEAL RAFTER I`-T RAFTERS I Al- I L=I ANCSCAPE CI AMP,SPACING ' ..� ._. .... 2'x6'AT 16'O.C. 1..... ■� 4 PV SYSTEM MOUNTING DETAIL S MODULES IN PORTRAIT/LANDSCAPE F� CLAMP SPACING COMP SHINGLES 21/2 MIN S 1 D Mm To sous S 1 0 MATT 3"MIN AND 6'MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE ONE HOLE STEEL STRAP CONDUIT �.__-- „_--____ ,..__ ___-_ .-.-_._.-_/ MIN 5/16"DIAM SS LAG SCREW >/ PV MODULE TYP.MOUNT ` ----- TOROUE=13x2 FT-LBS. ._ TO FRAMING OF EXISTING I v i v i n t.S o I a r � _1610 ROOF TYPE,PARALLELXIV -- -- WITH PLANE OF ROOF ' CONDUIT MOUNT BRACKET -6'MAXIMU - - _ 1.877 404.4129 SECTION VIEW1 2"FLASHING OR TILE STRAPZWI--- _ - DA COSTA RESIDENCE ANAIRRW} �W~t�� = AN•L � �V A� TEMPLETON PL WEST YARMOUT 02673-1537 3 SECTION VIEW UTILITY ACCOUNT B.1430 638 0024 S 1.0 NOT TO SCALE 6 PV ARRAY TYP.ELEVATION 7 CONDUIT MOUNTING DETAIL r $3.0 MOT TO SCALE 51.0 "OTT xAIE SERVICE It:S-6110393 REGIONAL S 1 .0 MOUNT DETAILS OPERATING CENTER MA-03 DATE:5.9.2019 DR AWNBY:CHARLSTON - SCALE:NOT TO SCALE - - - - L ALLEJO Photovoltaic System Conduit Conductor Schedule(ALL CONDUCTORS MUST BE COPPER) DC System Size(Watts) 4960 Tag it Description Wire Gauge tf of Conductors/Color Conduit Type Conduit Size o N AC System Size(Watts) 3800 1 PV Wire 12 AWG 2(V+,V-) N/A-Free Air N/A-Free Air o m co Total Module Count 16 1 Bare Copper Ground-EGC 6 AWG 1 BARE N/A-Free Air N/A-Free Air c a N , 2 THWN-2 12 AWG 2(1V+,1V-)B/R EMT 1/2" -• 0 .1m 2 THWN-2 EGC 12 AWG 1(GRN) EMT 1/2" cT W 2 3 THWN-2 12 AWG 3(111 1L2 1N)B/R/W EMT 1/2" „., c « c g J U F E 3 THWN-2 EGC 12 AWG 1(GRN) EMT 1/2" p o $ 4 THWN-2 6 AWG 3(111 1L2 1N)B/R/W EMT 3/4" p v ? 4 THWN-2 GEC 8 AWG 1(GRN) EMT 3/4" - M f: C f N oi f 0 ul v W w lJ of N V C 0 C ri cc O K N Solar Edge PV System SMART Meter Rapid Shutdown Point of Interconnection,Supply Z m O_ SE3800H-US 705.12(A) > j am, Disconnect,Square D *Conforms to ANSI C12.1-2008 DU221RB 240V/30A Square D D222NRB > Z iii et ;,, Unfused,NEMA3,or 240V/60A Fused,NEMA3, w w Z rn equivalent,with 75"C or equivalent,with 75°C Q Q U m / terminations terminations N z Q C Z Z e v Existing240V/100A SHEET ® 7 Service Panel,Single NAME: -A %' 1 Phase,with SODA Main ■+rlq l LINE Disconnect Ts 2 C pa .. _ ., 20A 11 100A �_ 41 STRING 1:16 PV 0 2 16 D I/ -lt_____. 3 LOA MODULES NEMA4 Junction Box }� re, C1 W/OPTIMIZERS . .3f. 0 0 0 SHEET ■ ) L , I Minimum GEC size NUMBER: _ K.y _- (1� ._ AWG copper 16PV MODULES PER INVERTER=4960 WATTS s,s a oca a nife'AC 'sile'Knife'AC ti STC Disconnect Disconnect,In Sight of Tap W PV Module Rating @ STC Conductor Calculations IN Module Make/Model linko Solar JKM310M-60BL 8 Wire gauge calculated from code art.310.15(B)(16)with ambient temperature calculations from 1: w Max.Power-Point Current(Imp) 9.4 Amps a art.310.15(B)(2)(a). Max.Power-Point Voltage(Vmp) 33 Volts For"On Roof"conductors we use the 90°C column ampacity,the relevant ambient temperature ° p ¢ m Open-Circuit Voltage(Voc) 40.5 Volts adjustment,and raceway fill adjustments from 310.15(B)(16). ci, W f .a, Optimizer Solar Edge P320 Short-Circuit Current(Isc) 9.92 Amps For"Off Roof"conductors we use the 75°C column ampacity,or the 90°C column ampacity with A d 5 j DC Input Power 320 Watts Max.Series Fuse(OCPD) 20 Amps the relevant ambient temperature and raceway fill adjustments,whichever is less. 8 E °u o DC Max.Input Voltage 48 Volts Nom.Max.Power at STC(Pmax) 310 Watts The rating of the conductor after adjustments MUST be greater than,or equal to,the continuous m o aa > DC Max.Input Current 13.75 Amps Max.System Voltage 1000 VDC(UL/IEC) duty uprated output current. _ DC Max.Output Current 15 Amps Voc Temperature Coefficient -0.29 I %/C Calculation Example-Wire Rating(90'C)x Ambient Temperature Adjustment x Conduit Fill 5 Max.string rating inverter dependent.See SE documents. Adjustment>=Continuous Duty Output Current Inverter Make/Model Solar Edge 5E3800H-US AC Output Current According to art.690.8(B)(1) 15.83 Amps (On Roof,Tag 2):12 gauge wire rated for 30 A, 30 A x 1 x 1(2 Conductors)=30 A>=18.75 A CEC Efficiency 99 % Nominal AC Voltage 240 Volts (Off Roof,Tag 3):12 gauge wire rated for 25 A, 25 A>=19.79 A (Off Roof,Tag 4):6 gauge wire rated for 65 A, 65 A>=19.79 A AC Operating Voltage 240 Volts THIS PANEL IS FED BY MULTIPLE SOURCES(UTILITY AND SOLAR) Cont.Max.Output Current 16 Amps ,______ DC Max.Input Current 10.5 Amps Rooftop conductor ampacities designed in compliance with art. Short Circuit Current 17.5 Amps 690.8,Tables 310.15(B)(2)(a),310.15(B)(3)(a),310.15(B)(3)(c), Max.Output Fault Current 17.5 A/20 ms 310.15(B)(16),Chapter 9 Table 4,5,&9. Location specific temperature obtained from ASHRAE 2017 data tables. ASHRAE 2017- Highest Monthly 2%D.B.Design Temp.:29.1°C • Lowest Min.Mean Extreme D.B.:-19.2°C $ -a m Si ti m N OCPD Calculations a a a Breakers sized according to continuous duty output current.PV circuit nominal current based off ccro inverter continuous output current X(1.25[art.690.8(A))). 5 .: O z 0 W N Inverter 1:SE3800H-US Max Output=15.83 A x 1.25[art.690.8(A)] > f o_ =19.79A<20A(OCPD) > system output current WI continuous duty=19.79<20A(System OCPD) w w vm z m J m 0 Other Notes 1° •Designed according to,and all code citations are relevant to,the NEC 2017. SHEET •All interior raceways carrying DC current shall be metallic. NAME: N I. W m 2 d SHEET NUMBER: N tL Conduit,Raceways,and 1-Boxes(Labeled Every 10')Per Plaques and Directories at the Service Equipment(MSP)and the SE3800H-US String 1 DC Disconnecting Means Per 690.53 0 ^� o0 690.31(G)(3)&(4) Location of All System Disconnects Per 690.56(B)&705.10 PHOTOVOLTAIC DC POWER SOURCE DISCONNECT �c a VD al 1.4 WARNING:PHOTOVOLTAIC POWER SOURCE CQ UTION: STRING 1 v O ¢ o POWER TO THIS BUILDIIJ�'IS ALSO SO}LIED FROM TbE MAXIMUM VOLTAGE: 380 V al „�, f ., Interactive System Point of Interconnection Per 690.54 FOLLOWING SOURCE WITH DISCO` TS LOCATEQ-AS MAXIMUM CURRENT: 15 A o 8 4 ,j3, I SHOWN -,. DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: 15 A e PHOTOVOLTAIC AC POWER SOURCE U i E 8 RATED AC OUTPUT CURRENT:15.83 A i. AM:� ,A `<i p .4. ', ¢ NOM.OPERATING AC VOLTAGE:240 V �.`- . TER D'rigp,`y�SE E T r CONNECT �. PV System Disconnects Per 690.13(B) r i ° v 1, PV SYSTEM DISCONNECT yy h All Disconnecting Means Per 690.13(8)&690.15(D) WARNING PV With Rapid Shutdown,Installed Within 3 ft of the Service ,__ ELECTRICAL SHOCK HAZARD Disconnecting Means Per 690.56(C)(1)(a) TERMINALS ON THE LINE AND LOAD SIDES SYSTEM� � " MAY BE ENERGIZED IN THE OPEN POSITIONMAR PY RAPO!� `.`T��RI P c Power Source Output Connection,Adjacent to Back- Vlirli Yf 7Y i V4/ N ,, fed Breaker Per 705.12 • o WARNING POWER SOURCE OUTPUT CONNECTION TURN RAPID SHUTDOWN d DO NOT RELOCATE THIS OVERCURRENT SWITCH TO THE , DEVICE "OFF"POSITION TO ALL SHUTDOWN PV SYSTEM u AND REDUCE Rapid Shutdown Switch Per 690.56(C)(3) SHOCK HAZARD El N IN ARRAY RAPID SHUTDOWN SWITCH FOR a v 0 Tr cc m O N cC m 1-- W m z fO o_ • Z w .1idw Z J T J• J 01 M O Z Z 2 7, SHEET NAME: m c N ft m 3 3 a SHEET NUMBER: ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY SHALL BE REFLECTIVE,THEY SHALL CONTAIN NO SMALLER THAN 3/8"WHITE ARIAL FONT TEXT,AND HAVE A RED BACKGROUND,UNLESS OTHERWISE DEPICTED OR DESCRIBED. en ALL PLACARDS SHALL BE WEATHER-RESISTANT,PERMANENTLY ETCHED PLACARDS.HANDWRITTEN SIGNS WILL NOT BE ACCEPTABLE. W CMAIN BREAKER DE-RATED TO•••DUE TO SOLAR ' AA \ PHOTOVOLTAIC AC POWER SOURCE PHOTOVOLTAIC DC POWER SOURCE DISCONNECT ra„ CIRCUITS �`+J RATED AC OUTPUT CURRENT:*••A ��� MAXIMUM VOLTAGE: *••A ••*-value calculated for each $ MAX OF•**AMPS PV SOURCE ALLOWED NOM.OPERATING AC VOLTAGE:'••V MAXIMUM CURRENT: *•*V account,for specific value see the c ii rrn label pageiD DO NOT INCREASE MAIN BREAKER RATING Property of Vivint Solar DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: "'A previouswarning P B -•o zo a m Property of Vivint Solar (S1 Property of Vivint Solar m w WARNING:PHOTOVOLTAIC POWER SOURCE �� c i 0_ WARNING �/� Property of Vivint Solar LJ SITE PLAN PLACARD SHOWING ADDITIONAL POWER SOURCE o ,§ 1 ��L , ELECTRICAL SHOCK HAZARD ��// coy E AND DISCONNECT LOCATIONS.PLACARD SHALL BE TERMINALS ON THE LINE AND LOAD SIDES MAY BE �� WARNING oar <,, ENERGIZED IN THE OPEN POSITION POWER SOURCE OUTPUT CONNECTION = Property of Vivint Solar �J MOUNTED ON EXTERIOR OF ELECTRICAL PANEL DO NOT RELOCATE THIS OVERCURRENT DEVICE Property of Vivint Solar D E,.,� PV SYSTEM DISCONNECT Property of Vivint Solar (�,S/, Property of Vivint Solar 77 // 10 PV rapid shutdown label required by • 7\ RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 690.56(C)(1)indicated on E.3 Property of Vivint Solar • C • 0s • o v 0 m v IF APPLICABLE m ROOFTOP ARRAY INSIDE PANEL O INSIDE PANEL 0 0 8 a EVERY 10'AND • 2 .1,ir 2 T 2 3 2 3 0 O O IF APPLICABLE a , OG O Pp` IF APPLICABLE I- w m O."a\1' ' Z 00 0_, F � � P M M > Z DC ; _ � ODISCONNECT N a o \ INSIDE ——— -- -- -- -- — I Z Z SHEET s. SOLAR INVERTERS COMBINER PANEL VISIBLE/LOCKABLE VIVINT SOLAR METER VISIBLE/LOCKABLE SUB PANEL MAIN SERVICE NAME: (MAY BE ON ROOFTOP (WHEN USED) A/C DISCONNECT (WHERE REQUIRED) A/C DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL m JUNCTION O INTEGRATED WITH (WHERE REQUIRED) 1 BOX ARRAY) TYPICAL SOLAR GENERATION INSTALLATION 3 (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) SHEET ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY SHALL THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT(DC)CONDUIT, NUMBER: BE REFLECTIVE,THEY SHALL CONTAIN NO SMALLER THAN 3/8"WHITE ARIAL FONT TEXT,AND ENCLOSURES,RACE-WAYS,CABLE ASSEMBLIES,JUNCTION BOXES COMBINER BOXES,AND DISCONNECTS TO ALERT HAVE A RED BACKGROUND,UNLESS OTHERWISE DEPICTED OR DESCRIBED.ALL PLACARDS THE FIRE SERVICE TO AVOID CUTTING THEM.MARKINGS SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT(3048 SHALL BE WEATHER-RESISTANT,PERMANENTLY ETCHED PLACARDS.HANDWRITTEN SIGNS WILL MM),ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES,WALLS OR BARRIERS. a NOT BE ACCEPTABLE. yj 1