HomeMy WebLinkAboutBlde-19-006458 o• Commonwealth of Official Use Only f. Massachusetts Permit No. BLDE-19-006458 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:5/15/2019 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to pertorm the electrical work described below. Location(Street&Number) 69 JOSHUA BAKER RD Owner or Tenant MENDEZ ALBINO S Telephone No. Owner's Address 69 JOSHUA BAKER RD,WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system. (12 Panels 3.72 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Siens Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: LLOYD R SMITH Licensee: Lloyd R Smith Signature LIC.NO.: 15688 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:30 1ST ST, MELROSE MA 021764010 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE:$150.00 j4:4- L-ommonweatth of ha/addact2udetts vi ii use kJ-my - cc�� ec77 Permit No. (.� t o��—£o�c6 aL Jepartmenf of }tre Serviced BOARD OF FIRE PREVENTION REGULATIONS [ Occupancy ev.1/0]y and Fee Checked (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK O TYPIE1ALL INFORMATION) Date: ` 3 113 I `c\ City or Town of: W.`lAC A To the Inspectorof Wires: By this application the undersigned gives notice o his or her intention to perform the electrical work described below. Location(Street& Number ,C )6Sht &Ne(' Co, . Parcel ID: Owner or Tenant Rh\h() Utrde,1. . Telephone No. 3•a&)•5(Q}CA Owner's Address SC\int. O C Is this permit in conjunction with a building permit? Yes No 7 (Check Appropriate Box) _, _ Purpose of Building . '\�i\ T Utility Authorization No. r Existing Service Amps / ZD Volts Overhead Undgrd No.of Meters ry', New Service Amps / Volts Overhead/ Undgrd No.of Meters , ---- Number of Feeders and Ampacity . < t Location and Nature of Proposed Electrical Work: in itktk koci-c rl Y o4 ma .e-ie Completion of the,following table may be waived by the Inspector of Wires. No.of -No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans Trans Total Transformers KVA . No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires SwimmingPool Above ❑ In- ❑ No.of Emergency Lighting grnd, grnd. Battery Units __ No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons b No.of Waste Disposers Heat Pump Number_Tons KW No.of Self-Contained Totals: - Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection_ No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: attach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: (de 5 La,O Cr (When required by municipal policy.) Work to Start:Co 12)1 Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE CI�VERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE S. BOND ❑ OTHER ❑ (Specify:) I certify, under the pains and penalties of perjury, that the information on this application( >LIC. true and complete. FIRM NAME: V`V t`nA- Sow(' �e'Jtt C €f LrLC. NO.: Licensee: ff ` �;.1 �nn �1-�, Signature {� : i,,i t t LIC.NO.: 1we (Ifctpplicabl ,,e er "ewe'ta'in the lice e neuter line.) L� ty0� aus.Tel.No.:1 (L/l�- ac Address: LL L/ °A s'W CIA-3 1 O I ELK— Alt.Tel.No.: J {P-9t-ii I *Per M.G.L. c. 147,s. 57-61,security work requires Department of Publi Safety"S"License: Lic. No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below, I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE:$ • JURISDIC I IONAL NO1 ES: GOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES 1. 2015 INTERNATIONAL RESIDENTIAL CODE 2. 2015 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION a. 2017 NATIONAL ELECTRICAL CODE b. ANY OTHER LOCAL AMENDMENTS SHEET INDEX: COVER SHEET PV 1.0-SITE PLAN S 1.0-MOUNT DETAILS E 1.0-ELECTRICAL DIAGRAM E 2.0-ELECTRICAL NOTES E 3.0-WARNING LABELS E 4.0-WARNING LABEL LOCATIONS GENERAL ELECTRICAL NOTES: GENERAL STRUCTURAL NOTES: 1. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL a. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING MEANS DESIGNED AND LISTED FOR SUCH USE.FOR ROOF-MOUNTED THE ROCK-IT SYSTEM BY ECOFASTEN.THE MOUNTING FEET ARE TO BE p SYSTEMS,WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF SPACED AS SHOWN IN THE DETAILS,AND MUST BE STAGGERED TO THE ROOF SURFACE. ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2. ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE b. UNLESS NOTED OTHERWISE,MOUNTING ANCHORS SHALL BE Na"LAG CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2X'PENETRATION INTO ROOF FRAMING. 3. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE c. THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. 4. RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE d. ROOF LIVE LOAD=20 psf TYPICAL,0 psf UNDER NEW PV SYSTEM. INVERTER.RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCEe. GROUND SNOW LOAD=30 psf VOLTAGE. f. WIND SPEED=140 mph 5. SEE*E 1.0 AND*E 2.0 FOR DIAGRAMS,CALCULATIONS,SCHEDULE AND g. EXPOSURE CATEGORY=B v i v i n t.So I a r ,oa 10,.11,,,Bake,Rudd SPECIFICATIONS. 1800 ASHTON BLVD.LEHI,UT,84043 1.877.404.4129 MA LICENSE ME-115688A,SS-002342 PHOTOVOLTAIC SYSTEM SPECIFICATIONS: MENDEZ RESIDENCE SYSTEM SIZE-3.720kW DC 3.800kW AC ST YARMOJOSHU BAKER RD WEST YARMOUTH,MA.02673 MODULE TYPE&AMOUNT-(12)Jinko Solar JKM310M-60BL WITH 12 SolarEdge P320 OPTIMIZERS UTILITY ACCOUNT N:14298500027 MODULE DIMENSIONS-(L/W/H)65.55/39.45/1.38" , 40 SERVICE 9:S-6104738 INVERTER-(1)SolarEdge Technologies SE3800H-US000BNC4 COVER REGIONAL INTERCONNECTION METHOD-LOAD BREAKER OPERATING CENTER:MA-03 DATE.5/3/2019 SHEETB"' DRAWN BY:DIN PV STRING(S); F OOF SEC 110N(S): SYSTEM LEGEND - 32 69 JOSHUA BAKER RD 1 SLOPE- ® #1112MODULES -z2e PVSYSTEMSIZE: MATERIAL- NEW 3.720kW DC 3.600kW AC FRONT OF HOUSE. COMPOSITION SHINGLE EXISTING 2.860kW DC I 3.800kW AC C.," EXISTING INTERIOR MAW SERVICE PANEL& ..�����-__�____���_ __�^ a POINT OF INTERCONNECTION.TIED TO UTILITY METER 42115437. Te- a NEW SMART PRODUCTION METER.LOCATED M O WITHW IS,OF MSP. ® NEW PV SYSTEM AC DISCONNECT. LOCATED WITHIN 10'OF MSP. 0 1 1 SEN3EWRW IHL SSY0S00T6ENMC W4 R EERXa PPEWED Technologies 12 NEW JINKO SOLAR JKM310M-NOBL MODULES. NEW SOLAR EDGE P320 OPTIMIZERS,MOUNTED ON THE BACK OF EACH MODULE. . 1+EXISTING TRINA SOLAR TSM-260,0E5.1e ••.MODUL FS. 1 NEW PV CONDUIT RUN.SEE EE1.0 CONDUIT SCHEDULE -----"EXTERIOR RUN ---- -"ATTIC RUN "0 }(NEW JUNCTION BOX.(MOUNTED WITH SOLADECK) v i /�j��j O •.•.�•��.��4 1�♦:.�.�♦.�.�.�.�1 E SE301 00A-J5TING�SYSTEM INVERTER(S)SULAREDGE '�'�"t•Y'�"�tiV.V. 4V4:7/"i"i"•:i"�"•��i"i�"4 U EEISTINI( PJ SYSTEM AC DISGONNE:'T 1i;���;��� ���4;+iii �iiiiii♦ < iTO RE AOEI ED'SYSTEM A' ►�����..., m.........,.,........ ❑ EXISTING UTILITY METER: O vivint.Solar 1.877.404.4129 MENDEZ RESIDENCE 69 JOSHUA BAKER RD WEST YARMOUTH.MA.02673 UTILITY ACCOUNT#:14298500027 S RVICE 10 736 SITE PLAN REGIONING CENTER REGIONAL PV 1"O OPERATING :MA-03 1 DATE:5/312014 SCALE:3/16"=1'-0" DRAWN BY DIN / \ MOUNTING LEGEND Twv4, WY ' '� OMP SHINGLES \ ROCK-R COUPLING 1 ? \ MID CLAMP � + ,wt., ROCK-IT COUPLING ROCK4T COUPLINGlik '}-JXr•�,�4 `� -4.1 vp4„r hr MID CLAMP MID CLAMP „� S �y}1 .r pyPP,; t ��\ ^ ., J°`�' rt,- ROCK-IT COUPLING SHELF i ft il ROCK-IT LI ROCK4T SLIDE SHIP LAP fj/, PEDESTAL METAL FLASHING ROCK-IT . METAL (INSTALLED PER MANUFACTURE'S INSTRUCTIONS)TIE PLATE 5/16-x1 112- COUPLING SHELF 5/16"x3/8- FLASHING HEX FLANGE BOLT HEX FLANGE BOLT el ISOMETRIC VIEW SIDE VIEW 30o SERIES SS ISOMETRIC VIE4y •300 SERIES SS '� a ter �� COMP SHINGLES `I SS LAG SCREW TOROUE-1332 FT-LBS. ♦, ►.. ��1 SIDE VIEWriMPIONE 1 B ILSCO SGB-4 GROUNDING LUGS 1 ROCK-IT MOUNT 510 1q 1O ILL LISTING voREcaureK:MO 2 ROCK-IT COUPLING ASSEMBLY —.._ _......_ S 1.0 NOT TO SCALE WEIGHT MIL S 1.0 NOT TO SCALE �_ roPvl W \. J CLAMP+ATTACHMENT CLAMP.ATTACHMENT COUPUNG �I PERMITTED COUPLING CANT V R 3OR CLAMP SPACING DSCAPE=MA%64"(5'-4') AX COUPLING P�CLAMPM �"(4) I"'II"'I RAFTER MODULE 111111 ROCK-IT SLIDE MODULE I„'II„'I MODULE METAL FLASHING r • ,I EPDM • BONDED WASHER RAFTER 111111 RAFTER —L FORMS WATERTIGHT SEAL RAFTER 2"x8"AT 16.O.C. !.� ^ SYSTEM MOUNTING DETAIL ODULES IN PORTRAIT(LANDSCAPE LAMPRTRA 51.0 ,nrro T �MOT TOSO. COMP SHINGLES 21/2 MN 3"MIN AND 8"MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE MIN 5/16"DIEM 1 ONE HOLE STEEL STRAP CONDUIT SS LAG SCREW u� A PV MODULE,TYP.MOUNT AI jark TOROUE=13t2 FT-LBS. ��//�' TO FRAMING OF EXISTING `, `, ROOF TYPE,PARALLELMr1 — �� 1 Y'Ytnt.Sol ar WITH PLANE OF ROOF CONDUIT MOUNT BRACKET '+✓ 1.877.404.4129 6"MAXIMU i SECTION VIEW // I 2" Al FLASHING OR TILE STRAP l.". MENDEZ RESIDENCE .w+v.e•r+rLw...... .,wrre•v+,ewer c.n 4r-+: wr�.Mut:ra tLwzr.:;>;" 69 JOSH UA BAKER RD SECTION VIEW 673 UTILITYTACCOUO ACCOUNT 14298500027 NOT TO SCALE 6 PV ARRAY TYP.ELEVATION 7 CONDUIT MOUNTING DETAIL S 1.D S 1.0 NOT W L/ SIT RA.... SERVICE k 6-6104738 MOUNT DETAILS REGIONAL OPERATING CENTER:MA-03 1.0 DATE:5,312019 SCALE:NOT TO SCALE DRAWN BY:DIN Photovoltaic System Conduit Conductor Schedule(ALL CONDUCTORS MUST BE COPPER) DC System Size(Watts) 3720 Tag 8 Description Wire Gauge C of Conductors/Color Conduit Type Conduit Size vsn .__.. AC System Size(Watts) 3800 1 PV Wire 12 AWG `2(V+,V-) N/A-Free Air N/A-Free Air o N __- L Total Module Count 12 1 Bare Copper Ground-EGC 6 AWG 1 BARE N/A-Free Air N/A-Free Air c W a 1 /`- — -- existing Inverter mtormanon. 2 THWN-2 12 AWG 2(1V+,1V-)B/R EMT 1/2" . Y m tasting Module intormatiu": Type.SOLAREDGE SE3000A US 2 THWN-2 EGC 12 AWG 1(GRN) EMT 1/2" •y m j a I Trina Solar 4Gry ti I ype:Tins So or o count. 3THWN-2 12 AWG 3(1L11L21N)B/R/W EMT 1/2" d n f c count a ,�/� 3THWN-2 EGC 12 AWG 1(GRN) EMT 1/2" c o a S d �/m Both AC Disconnects will be labelled 1 of 2 and 2 2 m , a ../� of 2 and a placard will be at the revenue meter o w %2 stating there are two disconnects for the PV. $ ( 0 4.1 VISIBRE IOCKAHtr C 'ENIFE VI 3of TISCONNEC' c4 EATON ER6NNP4 • LUA/240V u) UNFUSED NEMA3 0 OR EQUIVAIFNT m A 8 m N �� 7 • K N R S N F- Solar Edge m o SE3800H-US 5 M .:i `Conforms to ANSI C12.1-nog cC 2 20 Point of Interconnection,Load J LigJ Z 9 Side 705.12030)13HW Q U Q n Rapid Shutdown a LZN H Disconnect,Square D of Z R . DU221RB 240V/30A Unfused,NEMA3,or M SHEET equivalent,with 7S'C NAME: PV System SMART Meter terminations " LINE OD200A Existing 240V/200A C Service Panel,Single G '; STRING 1:12 PV f 2 12 20A Phase,with 200A Main 3 to MODULES NEMA 4 Junction Box 3 LO A A __ Disconnect W/OPTIMIZERS 3 IVI © W 20A SHEET 1 NUMBER: / - 10PV MODULES PER INVERTER=3100 WATTS I' f e 1' STC Visible/Lockable'Knife'AC Minimum GEC size4 tj 1"I Disconnect AWG capper W • ° PV Module Rating @ STC Conductor Calculations ,, Module Make/Model Jink°Solar JKM310M-60BL o us r. Wire gauge calculated from code art.310.15(B)(16)with ambient temperature calculations from mw g Max.Power-Point Current(Imp) 9.4 Amps- a .1art.310.15(13)(2)(a). w Max.Power-Point Voltage(Vmp) 33 _Volts For"On Roof"conductors we use the 90'C column ampacity,the relevant ambient temperature :2 Q i N Open-Circuit Voltage(Voc) 40.5 Volts d m •- a adjustment,and raceway fill adjustments from 310.15(6)(16). z m _Optimizer Solar Edge P32D Short-Circuit Current(Isc) 9.92 Amps For"Off Roof"conductors we use the 75°C column ampacity,or the 90°C column ampacity with g = f DC Input Power 320 Watts Max.Series Fuse(OCPD) 20 Amps the relevant ambient temperature and raceway fill adjustments,whichever is less. 1._ate`, vs c g 11 DC Max.Input Voltage 48 Volts Nom.Max.Power at STC(Pmax) 310 Watts The rating of the conductor after adjustments MUST be greater than,or equal to,the continuous g a, } a: DC Max.Input Current 13.75 Amps Max.System Voltage 1000 VDC(UL/IEC) duty uprated output current. 1s 3.' ..a.DC Max.Output Current 15 Amps Voc Temperature Coefficient -0.29 I %/C Calculation Example-Wire Rating(90°C)x Ambient Temperature Adjustment x Conduit Fill 3 7, Max.string rating inverter dependent.See SE documents. Adjustment>=Continuous Duty Output Current Inverter Make/Model Solar Edge 5E3800H-US AC Output Current According to art.690.8(B)(1) 15.83 Amps (On Roof,Tag 2):12 gauge wire rated for 30 A, 30 A x 1 x 1(2 Conductors)=30 A>=18.75 A CEC Efficiency 99_% Nominal AC Voltage 240 Volts (Off Roof,Tag 3):12 gauge wire rated for 25 A, 25 A>=19.79 A AC Operating Voltage 240 Volts THIS PANEL IS FED BY MULTIPLE SOURCES(UTILITY AND SOLAR) ._.. Cont.Max.Output Current 16_Amps ( DC Max.Input Current 10.5 r Amps Rooftop conductor ampacities designed in compliance with art. 0 Short Circuit Current 17.5 Amps 690.8,Tables 310.15(B)(2)(a),310.15(B)(3)(a),310.15(B)(3)(c), Max.Output Fault Current 17.5 A/20 ms 310.15(6)(16),Chapter 9 Table 4,5,&9. Location specific • temperature obtained from ASHRAE 2017 data tables. '� ASHRAE 2017- o, Highest Monthly 2%D.B.Design Temp.:29.1°C m Lowest Min.Mean Extreme D.B.:-19.2°C :I o in w m V Inverter Make/Model SOLAREDGE SE3000A-US _ PV Module Rating(i STC _ m N CEC Efficiency 0.99 % Module Make/Model Trina Solar TSM-260PD05.08 OCPD Calculations '" a AC Operating Voltage 240 Volts Max.Power-Point Current(Imp) 8.5 Amps yyyy Cont.Max.Output Current 12.5 Amps Max.Power-Point Voltage(Vrnp) 30.6 Volts n Breakers sized according to continuous duty output current.PV circuit nominal current based off m n DC Max.Input Current 9.5 Amps Open-Circuit Voltage(Voc) 38.2 Volts co inverter continuous output current X(1.25[art.690.8(A)]). g Short Circuit Current 9.5 Amps Short-Circuit Current(1st) 9 Amps O m°'. m m Max.Output Fault Current 17 Max.Series Fuse(OCPD) 15 Amps Inverter 1:5E3800H-US Max Output=15.83 A x 1.25[art.690.8(A)) z m o_ _ Nom.Max.Power at STC(Pmax) 260 Watts =19.79 A<20 A(OCPD) - m .-. Max.System Voltage 1000 V(IEC)/600 V(UL) system output current w/continuous duty=19.79<20A(System OCPD) > z ill iii a Voc Temperature Coefficient -0.32 I %/C Existing System output current w/continuous duty=15.625<=20A(Existing System OCPD) '_'i Z cc Other Notes �+ rn a z z g m •Designed according to,and all code citations are relevant to,the NEC 2017. SHEET •All interior raceways carrying DC current shall be metallic. NAME: N sm z a SHEET NUMBER: N W • • Irl N Conduit,Raceways,and 1-Boxes (Labeled Every 10')Per Plaques and Directories at the Service Equipment(MSP)and the SE3800H-US String 1 DC Disconnecting Means Per 690.53 o N ,v 690.31(G)(3)&(4) Location of All System Disconnects Per 690.56(8)&705.10 u z < PHOTOVOLTAIC DC POWER SOURCE DISCONNECT c z WARNING:PHOTOVOLTAIC POWER SOURCE CAUTION: STRING 1 ' Y •m POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE MAXIMUM VOLTAGE: 380 V y m a FOLLOWING SOURCES WITH DISCONNETS LOCATED AS MAXIMUM CURRENT: 15 A < 0 Interactive System Point of Interconnection Per 690.54 _ n c SHOWN DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: 15 A d x 5 o PHOTOVOLTAIC AC POWER SOURCE -- NO < n. RATED AC OUTPUT CURRENT:15.83 A AT i' m F NOM.OPERATING AC VOLTAGE:240 V I,`,� .°. METER AND MAIN SERVICE LD w &^I ' iti AC DISCONNECT 3 PV System Disconnects Per 690.13(B) I t NVERTERNNECT PV SYSTEM DISCONNECT (+ ,. --� All Disconnecting Means Per 690.13(8)&690.15(D) a..... WARNING PV With Rapid Shutdown,Installed Within 3 ft of the Service H ELECTRICAL SHOCK HAZARD Disconnecting Means Per 690.56(C)(1)(a) TERMINALS ON THE LINE AND LOAD SIDESLi - :� MAY BE ENERGIZED IN THE OPEN POSITION ° .)1 ;- Power Source Output Connection,Adjacent to Back- . m fed Breaker Per 705.12 • $ WARNING iii POWER SOURCE OUTPUT CONNECTION TURN RAPID SHUTDOWN DO NOT RELOCATE THIS OVERCURRENT SWITCH TO THE w DEVICE "OFF"POSITION TO ; SHUTDOWN PV SYSTEM AND REDUCE Rapid Shutdown Switch Per 690.56(C)3) SHOCK HAZARD RAPID SHUTDOWN SWITCH FOR IN ARRAY ,mi m v a . 4 3 o & 2", m m S 2 .,i • Z LI W W Z • u A G G < 8 Zzg ,o SHEET NAME: ea C N q z m 33a SHEET NUMBER: ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY SHALL BE REFLECTIVE,THEY SHALL CONTAIN NO SMALLER THAN 3/8"WHITE ARIAL FONT TEXT,AND HAVE A RED BACKGROUND,UNLESS OTHERWISE DEPICTED OR DESCRIBED. m ALL PLACARDS SHALL BE WEATHER-RESISTANT,PERMANENTLY ETCHED PLACARDS.HANDWRITTEN SIGNS WILL NOT BE ACCEPTABLE. tai • RATED TO••"DUE TO SOLAR PHOTOVOLTAIC AC POWER SOURCE RATED AC OUTPUT CURRENT:'•`A �� PHOTOVOLTAIC DC POWER SOURCE DISCONNECT*"Vm C MAIN BREAKER DE-CIRCUITS �� J �� MAXIMUM VOLTAGE: *"A "•-value calculated for each o ry MAX OF***AMPS PV SOURCE ALLOWED NOM.OPERATING AC VOLTAGE:***V MAXIMUM CURRENT: • V account,for specific value see the $ °G a' a DO NOT INCREASE MAIN BREAKER RATING Property of Vivint Solar DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: ***A previous warning label page c Y m Property of Vivint Solar / .. Property of Vivint Solar 'II Property x k- ' 5 WARNING:PHOTOVOLTAIC POWER SOURCE cc cc < p 2 WARNING �- Property of Vivint Solar 9 SITE PLAN PLACARD SHOWING ADDITIONAL POWER SOURCE c N 0 ELECTRICAL SHOCK HAZARD \� AND DISCONNECT LOCATIONS.PLACARD SHALL BE • o a S TERMINALS ON THE LINE AND LOAD SIDES MAYBE (" WARNING 2 m r a ENERGIZED IN THE OPEN POSITION 6 MOUNTED ON EXTERIOR OF ELECTRICAL PANEL �o w ,; J POWER SOURCE OUTPUT CONNECTION Property of Vivint Solar 3 Property of Vivint Solar DO NOT RELOCATE THIS OVERCURRENT DEVICE C PV SYSTEM DISCONNECTProperty of Vivint Solar /Property of Vivint Solar10PV rapid shutdown label required by J ; RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM �J 690.56(C)(1)indicated on E.3 Property of Vivint Solar 0.3 tI r C a 4310) u V IF APPLICABLE m ROOFTOP ARRAY 7 $1CP INSIDE PANEL (j INSIDE PANEL O 9 0 r EVERY 10'AND p, ^L O ,'•'SO?aG O L 4 O 1 IF APPLICABLE , �s 2 o g ,..., O 9p�"�,a IF APPLICABLE „�� m .o- O M , ZN. W W Z co O _ r, DISCONNECT G N a g INSIDE z z 2 SHEET R VISIBLE/LOCKABLE VIVINT SOLAR METER VISIBLE/LOCKABLE SUB PANEL MAIN SERVICE t NAME: �, SOLAR INVERTERS COMBINER PANEL\ \ JUNCTION (MAY BE ON ROOFTOP (WHEN USED) A/C DISCONNECT (WHERE REQUIRED) A/C DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL BOX O INTEGRATED WITH (WHERE REQUIRED) 'E =^ ARRAY) TYPICAL SOLAR GENERATION INSTALLATION p ell (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) 3 d SHEET ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY SHALL THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT(DC)CONDUIT, NUMBER: BE REFLECTIVE,THEY SHALL CONTAIN NO SMALLER THAN 3/8'WHITE ARIAL FONT TEXT,AND ENCLOSURES,RACE-WAYS,CABLE ASSEMBLIES,JUNCTION BOXES COMBINER BOXES,AND DISCONNECTS TO ALERT HAVE A RED BACKGROUND,UNLESS OTHERWISE DEPICTED OR DESCRIBED.ALL PLACARDS THE FIRE SERVICE TO AVOID CUTTING THEM.MARKINGS SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT(3048 SHALL BE WEATHER-RESISTANT,PERMANENTLY ETCHED PLACARDS.HANDWRITTEN SIGNS WILL MM),ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES,WALLS OR BARRIERS. et NOT BE ACCEPTABLE. yj