E-19-5241
Commonwealth of Official Use Only Massachusetts Permit No. BLDE-19-005241 "° BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked i[Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date•3/18/2019 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 34 CIRCUIT RD NORTH Owner or Tenant CROWLEY STEPHEN J Telephone No. Owner's Address 34 CIRCUIT RD NORTH,WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system. (38 Panels) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number , Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: LLOYD R SMITH Licensee: Lloyd R Smith Signature LIC.NO.: 15688 (Inapplicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:30 1ST ST, MELROSE MA 021764010 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 44. 4(( (0( (a - Application ivumoer: aa�//t;.I.U.g: Commonwealth o///Ia98acLeti4 CIA Use Only * AA! cc�� c7 Permit No. G 9 —S-2 -( 'tr _ t 2epartment o/ ire Serviced T�_0 Occupancy and Fee Checked ,,. BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC).527 CMR 12.00 ' (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 3) 1 City or Town of: ( r LW A-V1 To the Inspector of)'Wires: By this application the undersignedgives notice of his or her intention to perform the electrical work described below. Location(Street&Number)c .�i ( CA\CCU i } Parcel ID: Owner or Tenant &i IQ Telephone No. 7 Zg Z..- r - ... _Owner SO '�a Spy C�wn�3r's Address (�(� S al ,._' Isrth4 permit in conjunction with a building permit? Yes No ❑ (Check Appropriate Box) ' i�grpisse of Building u �r1\� Utility Authorization No. �.istfing Service 2, Amps � / Z140 Volts Overhead Undgrd❑ No.of Meters Nvervice Amps / Volts Overhead Undgrd n No.of Meters i0 •-....�\Q m. P1gmler of Feeders and Ampacity ' t''4"sJ Location and Nature of Proposed Electrical Work: insi kkkocfRKl a.c Y t.""0 maxikkek `l3PAC c trtcc, ‘SC\C/C SytS +Y\• ,38 0Cl S . Completion of the followingtable may be waived by the Inspector of Wires. No. rano No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Transformers KVA . No.of Luminaire Outlets No.of Hot Tubs Generators KVA Above ❑ In- 121 No.of Emergency Lighting No.of Luminaires Swimming Pool grbno grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones 11 No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges • No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water Kam, No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunicationso fDevices or qu in No.of Devices Equivalent OTHER: � �� ,4ttach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: ZSp.J 1 1- qq•o -) (When required by municipal policy.) Work to Start: I/ //1 9 Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE C GE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ❑ BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application •• ue and complete. FIRM NAME: v'V ia-k S v\fJ- Theot.<< Qr Li-C LIC.NO.: Licensee:L l t, Srnikr Signature Lid.t LIC.NO.: I Of applicable. enter a +et"in the ice a nu er line.) pus.Tel.No.: -�-1n Address: 214 U Ut\( C(l c SY1'(Jj(U O S Alt.Tel.No.: *Per M.G.L. c. 147,s. 57-61,security work requires Department of Publr Safety"S" License: Lic. No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent PERMIT FEE:$ /50 Signature Telephone No. 4 1 a JURISDICTIONAL-NOTES: _-_-- -- GOVERNING GOVERNING CODES `r ALL WORN SHALL CONFORM TO THE FOLLOWING CODES a. 2015 INTERNATIONAL RESIDENTIAL COD b. 2017 NATIONAL ELECTRICAL CODE c. ANY OTHER LOCAL AMENDMENTS SHEET INDEX: COVER SHEET PV 1.0-SITE PLAN S 1.0-MOUNT DETAILS E 1.0-ELECTRICAL DIAGRAM E 2.0-ELECTRICAL NOTES E 3.0-WARNING LABELS E 4.0-WARNING LABEL LOCATIONS GENERAL ELECTRICAL NOTES: GENERAL STRUCTURAL NOTES: . ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL a. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING MEANS DESIGNED AND LISTED FOR SUCH USE.FOR ROOF-MOUNTED THE SFM SYSTEM BY UNIRAC.THE MOUNTING FEET ARE TO BE SPACED AS SYSTEMS,WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF SHOWN IN THE DETAILS,AND MUST BE STAGGERED TO ADJACENT FRAMING et,' THE ROOF SURFACE. MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. . ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE b. UNLESS NOTED OTHERWISE,MOUNTING ANCHORS SHALL BE X6 LAG -. k CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2;1"PENETRATION INTO ROOF FRAMING. `.� a. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE c. THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. .,,,; , RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE d. ROOF LIVE LOAD=20 psf TYPICAL,0 psf UNDER NEW PV SYSTEM. • INVERTER.RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCEe. GROUND SNOW LOAD=30 psf VOLTAGE. I. WIND SPEED=140mph , J -: 1: , 1 r.h _ . 'E SEE"E 1.0 AND 2.0 FOR DIAGRAMS,CALCULATIONS,SCHEDULE AND g. EXPOSURE CATEGORY=B V I V I n t.SOIa r SPECIFICATIONS. `tic's''',. 1800 ASHTON BLVD.LEHI,UT,84043 ! 1.877.404.4129 I t MA LICENSE: HIC-170848, ' 4 �_.... ME-15688A,SS-00234 J PHOTOVOLTAIC SYSTEM SPECIFICATIONS: �_ CALLE RESIDENCE / C ; SYSTEM SIZE-11.780kW DC 7.600kW AC 34 CIRCUIT RD N a„ WEST YARMOUTH,MA,02673-3607 MODULE TYPE&AMOUNT-(38)Jinko Solar JKM310M-60BL WITH 38 SolarEdge P320 OPTIMIZERS UTILITY ACCOUNT#:2710 667 0030 MODULE DIMENSIONS-(L/W/H)65.55"/39.45"/1.38" - INVERTER-(1)SolarEdge Technologies SE7600H-USOOONNC2 SERVICE p 56057528 REGIONAL 4(' INTERCONNECTIONMETHOD-SUPPLYTAP OPERATING CENTER,MA-03• COVER ,» '•„ DATE:2.19.2019 SHEET DRAWN BY JC -- -- PV STRING(S): • • SYSTEM LEGEND Q SLOPE-45.7 ® #1)19 MODULES AZIMUTH-306.66 PV SYSTEM SIZE: MATERIAL- NEW 11.780kW DC I 7.600kW AC ® #2)19 MODULES „COMPOSITION SHINGLE 2 SLOPE-45 EXISTING INTERIOR MAIN SERVICE PANEL \o \ AZIMUTH-306.66 ®POINT OF INTERCONNECTION.TIED TO UTLITY \\T MATERIAL„COMPOSITION MPOII- METER#2291188. OMPOSITION SHINGLE NEW PV SYSTEM AC DISCONNECT. LOCATED SLOPE-45.7 a WITHIN 10'OF MSP. \\ . \\\ AZIMUTH-126.66 — 1 NEW PV SYSTEM INVERTER:SolarEdge Technologies MATERIAL- I SE7600H-USOOONNC2(RSD EQUIPPED) COMPOSITION SHINGLE 38 NEW JINKO SOLAR JKM310M-60BL MODULES. O NEW SOLAR EDGE P320 OPTIMIZERS,MOUNTED 1 ON THE BACK OF EACH MODULE. NEW PV CONDUIT RUN.'SEE EE1.0 CONDUIT SCHEDULE _-_=EXTERIOR RUN — =ATTIC RUN V/j O O �\ NEW JUNCTION BOX.(MOUNTED TO PV MODULE) A 1r` � EXISTING1 UTILITY METER / j j elj Z /� j %%r 0rr:\W-.. A�% A% UE \\\\\\\\''\. O j •4Y4 vivint.Solar / \ 1.877.404.4129 j \ j■ ~ / ‘,\.\\ CALLS RESIDENCE 34 CIRCUIT RD N WEST YARMOUTH,MA,02673-3607 UTILITY ACCOUNT#:2710 667 0030 O M O I SERVICE#.S-6057528 SITE PLAN REGIONA OPERATI - RNG CENTER:MA-03 PV 1.0 DATE 2.192019 SCALE:3/16"=1 i-0a ,DRAWN BY:JC f J .._.-______-_... _-._- -. _.-__.._ _. -.___.._. _ -_.__ __.__-_._._ -_ .. -.__-__ ___-_..-_ -�__ II _ MOUNTING LEGEND ��`o y` Al�� PER MfR RMFR HEw ! `'! NND MOWLE1111- ,. i',,1 - �n :: ,i\�1 'll 4 SFM-9"ATTACHED SPLICE \,. "-'�'--• . S 1.0 NDT TD SCALE I I V 41 -IENN / 4 21/2'MIN .. ......ir.--..iri 'lc - ---011144CLC .1, ,,,.. ..ram si \' SFM-TRIMRAIL WITH 1 SFM-ROOF ATTACHMENT 2 SECTION VIEW 3 ROOF ATTACHMENT 5 SFM-3"RAIL S 1.0 NOT TO SCALE S 1.0 NOT TO SCALE S 1.0 NOT TO SCALE S 1.0 NOT TO SCALE SFM 9'ATTACHED SPLICE ..% ,�� LIAMP.ATTACHMENT CLAMP.ATTACHMENT - / `� cODPLING COUPLING SFM 9'SPLICE _ SFM J' I 1111111111 RAFTER MODULE 4 I IIIIIIII I ®ILLSCOO SGB-4 GROUNDING LUGS �I I 1111111111 NODDLE 11111111�� FT RAFTER. TRIMRAIL SPLIC 9 MODULES IN PORTRAIT/LANDSPACE TRIMRAIL ROOF ATTALIIMENTESEE TABLE ' $SO NOT TO SCALE 6 SFM LAYOUT TRIMRAIL B SFM-9"SPLICE $1.0 NOT TO SCALE S 1.0 NOT TO SCALE _ CANTILEVER LOR LESS vivint.Solar 1 1 MAA�. wuxwc :iirIL \-__ 1.877.404.4129 J CLAMP JSnun PROFILE 6'MAX T MGaLE i/ CALLE RESIDENCE 11 A 11 11 RAFTER ► t 34 CIRCUIT RD N WEST YARMOUTH, MA,02673-3607 19 PV SYSTEM MOUNTING DETAIL 11 SFM-TRIMRAIL l UTILITY ACCOUNT#:2710 667 0030 S 1.0 NOT TO SCALE $1.0 NOT To SCALE 00mm PROFILE SERVICE 8:S-6057528 1 .0 MOUNT DETAILS REEp � S REGION OPERATING CENTER.MA-03 DATE:2.19.2019 SCALE:NOT TO SCALE DRAWN BY JC Photovoltaic System Conduit Conductor Schedule(ALL CONDUCTORS MUST BE COPPER) DC System Size(Watts) 11780 Tag 8 Description Wire Gauge 0 of Conductors/Color Conduit Type Conduit Size ,,., cz m AC System Size(Watts) 7600 1 PV Wire 12 AWG 2(V+,V-) N/A-Free Air N/A-Free Air us 8 Total Module Count 38 1 Bare Copper Ground-EGC 6 AWG 1 BARE N/A-Free Air N/A-Free Air a z < 4, 2 THWN-2 12 AWG 4(2V+,2V-)B/R EMT 1/2" d a x 2 THWN-2 EGC 12 AWG 1(GRN) EMT 1/2" v I- N 3 THWN-2 8 AWG 3(111 1L2 1N)B/R/W EMT 3/4" a s O 3 THWN-2 EGC 10 AWG 1(GRN) EMT 3/4" w it z o 4 THWN-2 6 AWG 3(1L1 1L2 1N)B/R/W EMT 3/4" U m i 4 THWN-2 GEC 8 AWG 1(GRN) EMT 3/4" `r'3 L en 4.1 0 4, b o, N rt a a a cc r. Solar Edge g ,i SE7600H US p `,d 'Conforms to ANSI 2 N C12,1-2008Point of Interconnection,Supply Side H m m PV System SMART Meter Rapid Shutdown Z O Disconnect,Square D 705.121A) 7 DU222RB240V/60A Square D222NR8 5 Z Unfused,NEMA3,or W w Z 240V/60A fused,NEMA3, 40 j equivalent with 75'C or equivalent,with 75°C J J u — terminations ''' _ terminations N N Q f\i STRING 2:19 PV 0 19 Existing 240V/200A SHEET MODULES (( Service Panel,Single NAME: W/OPTIMIZERS . .°� 14 r - -�_-- LINE - Phase,with 200A Main m Disc nect • lit V sy, _ -_ .._.__..:._-- - - t. 40A 11 200A c LI m STRING 1:19 PV t 2 19 -- / MODULES NEMA 4 Junction Box T ��� ���,,,...,,, W/OPTIMIZERS /�-- LOAN • �� SHEET - ��ll - Minimum GEC size 4 NUMBER: AWG copper 38PV NODULES PER INVERTER=11780 WATTS T , vi STC Vis a oc a e rife AC is a oc a le'Knife'AC Disconnect Disconnect,In Sight of Tap W •1 PV Module Rating @ STC I Conductor Calculations o Module Make/Model Jinko Solar 1KM310M-60BL . o Wire gauge calculated from code art.310.15(B)(16)with ambient temperature calculations from ^' i. Max.Power-Point Current(Imp) 9.4 Amps a, Z < e art.310.15(B)(2)(a). o g w Max.Power-Point Voltage(Vmp) 33 Volts For"On Roof"conductors we use the 90°C column ampacity,the relevant ambient temperature are _o9 Open-Circuit Voltage(Voc) 40.5 Volts adjustment,and raceway fill adjustments from 310.15(B)(16). v •-• 1- ^^7 Optimizer Solar Edge P320 Short-Circuit Current(Isc) 9.92 Amps For"Off Roof"conductors we use the 75'C column ampacity,or the 90°C column ampacity with w it 0 E. DC Input Power 320 Watts Max.Series Fuse(OCPD) 20 Amps the relevant ambient temperature and raceway fill adjustments,whichever is less. ;I, ° DC Max.Input Voltage 48 Volts Nom.Max.Power at STC(Pmax) 310 Watts The rating of the conductor after adjustments MUST be greater than,or equal to,the continuous U DC Max.Input Current 13.75 Amps Max.System Voltage 1000 VDC(UL/IEC) duty uprated output current. w DC Max.Output Current 15 Amps Voc Temperature Coefficient -0.29 I %/C Calculation Example-Wire Rating(90"C)x Ambient Temperature Adjustment x Conduit Fill 3 Max.string rating inverter dependent.See SE documents. Adjustment =Continuous Duty Output Current Inverter Make/Model Solar Edge 5E7600H-US AC Output Current According to art.690.8(B)(1) 31.67_Amps (On Roof,Tag 2):12 gauge wire rated for 30 A, 30 A x 1 z 0.8(4 Conductors)=24 A>=18.75 A CEC Efficiency 99 % Nominal AC Voltage 240 Volts (Off Roof,Tag 3):8 gauge wire rated for 50 A, 50 A>=39.58 A AC Operating Voltage 240 Volts THIS PANEL IS FED BY MULTIPLE SOURCES(UTILITY AND SOLAR) (Off Roof,Tag 4):6 gauge wire rated for 65 A, 65 A>=39.58 A Cont.Max.Output Current 32 Amps __. DC Max.Input Current 20 Amps Rooftop conductor ampacities designed in compliance with art. Short Circuit Current 40 Amps 690.8,Tables 310.15(B)(2)(a),310.15(B)(3)(a),310.15(B)(3)(c), Max.Output Fault Current 40 A/20 ms 310.15(B)(16),Chapter 9 Table 4,5,&9. Location specific temperature obtained from ASHRAE 2017 data tables. ASHRAE 2017- �� Highest Monthly 2%D.B.Design Temp.:29.1°C cin Lowest Min.Mean Extreme D.B.:-19.2°C •5 "' N a a m a v m N OCPD Calculations a 8 a Breakers sized according to continuous duty output current.PV circuit nominal current based off ccm inverter continuous output current X(1.25[art.690.8(A)]). O .: v, ,i 01 m Inverter 1:5E7600H-U5 Max Output=31.67 A x 1.25[art.690.8(A)] z coo =39.SSA<40A(OCPD) ti> system output current w/continuous duty=39.58<40A(System OCPD) W cc ;n w JN f` Other Notes 1— N N (Z' z g •Designed according to,and all code citations are relevant to,the NEC 2017. SHEET •All interior raceways carrying DC current shall be metallic. NAME: r, sr o m 2 d SHEET NUMBER: N W 0 Conduit,Raceways,and 1-Boxes (Labeled Every 10')Per Plaques and Directories at the Service Equipment(MSP)and the SE7600H-US String 1 DC Disconnecting Means Per 690.53 N o 690.31(G)(3)&(4) Location of All System Disconnects Per 690.56(B)&705.10 z a n PHOTOVOLTAIC DC POWER SOURCE DISCONNECT M ,c WARNING:PHOTOVOLTAIC POWER SOURCE UTION: STRING 1 `m z m o POWER TO THIS BUILDIO IS ALSO SU) 3LIED FROM gE MAXIMUM VOLTAGE: 400 V f- 1— FOLLOWING SOURCE WITH DISCONNETS LOCATEI c AS MAXIMUM CURRENT: 15 A u o Interactive System Point of Interconnection Per 690.54 �c —------ --��. SHOWN „�C� r„�> IDC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: 15 A m PHOTOVOLTAIC AC POWER SOURCE '.) !,, N m 8 `< RATED AC OUTPUT CURRENT:31.67 A I aQ ,,,^:, .r,, � ,\ � ;,,, � NOM.OPERATING AC VOLTAGE:240 V Ste' r=-, ., St'TER D SEptytCE SE7600H-US String 2 DC Disconnecting Means Per 690.53 w N _ . 3 j ; �` DC� ECT PHOTOVOLTAIC DC POWER SOURCE DISCONNECT PV System Disconnects Per 690.13(B) , �,. INV T i ," STRING 2 �'r �`�. MAXIMUM VOLTAGE: 400 V PV SYSTEM DISCONNECT 'L -- �, _ _ <... 'N. MAXIMUM CURRENT: 15 A All Disconnecting Means Per 690.13(B)&690.15(D) DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: 15 A WARNING PV With Rapid Shutdown,Installed Within 3 ft of the Service ,___ ELECTRICAL SHOCK HAZARD Disconnecting Means Per 690.56(C)(1)(a) TERMINALS ON THE LINE AND LOAD SIDES SOLAR , • TIPPED MAY BE ENERGIZED IN THE OPEN POSITION SYSTEM _ fa Power Source Output Connection,Adjacent to Back- SHUTDOWNMTH RAPID c fed Breaker Per 705.12 — �/ al WARNING �C7 ''' POWER SOURCE OUTPUT CONNECTION TURN RAPID SHUTDOWNii DO NOT RELOCATE THIS OVERCURRENT SWITCH TO THE v DEVICE "OFF"POSITION TO ACtalra alcricL W SHUTDOWN PV SYSTEM U AND REDUCE Rapid Shutdown Switch Per 690.56(C)(3) SHOCK HAZARD SI N RAPID SHUTDOWN SWITCH FOR IN ARRAY a SOLAR PV SYSTEM § r, ¢ m z N z co o > z W w w w m 71 J N N Q r` z z Q 8 b SHEET NAME: C c •C N 'a .moo m 3 3 in SHEET NUMBER: ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY SHALL BE REFLECTIVE,THEY SHALL CONTAIN NO SMALLER THAN 3/8"WHITE ARIAL FONT TEXT,AND HAVE A RED BACKGROUND,UNLESS OTHERWISE DEPICTED OR DESCRIBED. M ALL PLACARDS SHALL BE WEATHER-RESISTANT,PERMANENTLY ETCHED PLACARDS.HANDWRITTEN SIGNS WILL NOT BE ACCEPTABLE. ui MAIN BREAKER DE-RATED TO 'DUE TO SOLAR �AA� PHOTOVOLTAIC AC POWER SOURCE �- PHOTOVOLTAIC DC POWER SOURCE DISCONNECT ro ,�' ‘.01 CIRCUITS" �`+J RATED AC OUTPUT CURRENT:`"'A MAXIMUM VOLTAGE: ""A ***-value calculated for each $ MAX OF***AMPS PV SOURCE ALLOWED NOM.OPERATING AC VOLTAGE:"**V J MAXIMUM CURRENT: ***V account,for specific value see the w Z a DO NOT INCREASE MAIN BREAKER RATING Property of Vivint Solar DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: "*A previous warning label page d z f o Property of Vivint Solar r Property of Vivint Solar 74 t= 1- r^, WARNING:PHOTOVOLTAIC POWER SOURCE � u O .1 .,- WARNING Property of Vivint Solar ( y SITE PLAN PLACARD SHOWING ADDITIONAL POWER SOURCE a 6 ¢ o ���/, ELECTRICAL SHOCK HAZARD /' AND DISCONNECT LOCATIONS.PLACARD SHALL BE 7 m TERMINALS ON THE LINE AND LOAD SIDES MAY BE (- 1 WARNING ENERGIZED IN THE OPEN POSITION 6 MOUNTED ON EXTERIOR OF ELECTRICAL PANEL �1 POWER SOURCE OUTPUT CONNECTION Property of Vivint Solar 3 Property of Vivint Solar DO NOT RELOCATE THIS OVERCURRENT DEVICE 1 PV SYSTEM DISCONNECT Property of Vivint Solar 3 Property of Vivint Solar \1 PV rapid shutdown label required by RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM �J 690.56(C)(1)indicated on E.3 Property of Vivint Solar • •C al • ti N U m N V IF APPLICABLE m ROOFTOP ARRAY0 INSIDE PANEL 0 INSIDE PANEL 0 0 ry v r-Zg EVERY 10'AND `I- .PG2 T © © 3 O O O IF APPLICABLE oOPoo�F o� IF APPLICABLE i- d m '5,(ti i z fO 2— pq.9�•( O O ; ce 0, DC M M ww " Z . ® "-,• DISCONNECT a � DI _ INSIDE ———• ——— -- -- -- -- ■ z SHEET • SOLAR INVERTERS COMBINER PANEL VISIBLE/LOCKABLE VIVINT SOLAR METER VISIBLE/LOCKABLE SUB PANEL MAIN SERVICE NAME: (MAY BE ON ROOFTOP (WHEN USED) A/C DISCONNECT (WHERE REQUIRED) A/C DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL m JUNCTION O INTEGRATED WITH (WHERE REQUIRED) E BOX ARRAY) TYPICAL SOLAR GENERATION INSTALLATION "3 .CI ba 3 a (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) SHEET ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY SHALL THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT(DC)CONDUIT, NUMBER: BE REFLECTIVE,THEY SHALL CONTAIN NO SMALLER THAN 3/8"WHITE ARIAL FONT TEXT,AND ENCLOSURES,RACE-WAYS,CABLE ASSEMBLIES,JUNCTION BOXES COMBINER BOXES,AND DISCONNECTS TO ALERT HAVE A RED BACKGROUND,UNLESS OTHERWISE DEPICTED OR DESCRIBED.ALL PLACARDS THE FIRE SERVICE TO AVOID CUTTING THEM.MARKINGS SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT(3048 SHALL BE WEATHER-RESISTANT,PERMANENTLY ETCHED PLACARDS.HANDWRITTEN SIGNS WILL MM),ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES,WALLS OR BARRIERS. mr NOT BE ACCEPTABLE. u j