HomeMy WebLinkAboutReview Checklist C-)-')--IS TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 2.1 Lot 21- Zone of Contribution: In Out acreage Commercial: Residential: Street: 2Pt..-/Y9 ��� / 1 Village: ,fr- Floor Plan: s�� #Bedrooms: Owner: � 7 Installer: r Address: Phone: _ / Phone: - ` , //en ;._ fl. //elite '-q./1Z, , t 446 7 Address: Phone: Builder: Engineer: Phone: way '3/715,/_,A'7,5---;t7.94:21-4f,. i r7 a N/A YES NO fres 1�'�� 1.Required#of copies received ✓ 9:ANIS 2.Date of soils exam and percolation test not older than 2 years C.--'-- e _cc,// 3.4-5 ft of naturally occurring pervious material, above water table ( -UV 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ,..._-------- 5. ..._-/5. Water line 10 ft from septic components Var.: t 6. Benchmark indicated and shown-NGVD if near wetlands (...---- 7. Septic tank minimum 10 ft from foundation, deck Var.: L----- 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: l �� 9.Leaching minimum 100 ft from wetlands Var.: t ' `)i -- 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: '- 11.Tank/leaching minimum 10 ft from property line Var.: t 12. System meets all other setback requirements Var.: '..-- 13.Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj. water or botto of tesfiioWar.: 15. System not in top or subsoil(A,B horizons) 5'remo 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", '/4"preferred ,.--- 18. System meets breakout requirements PVC liner:, 4( Wall: 1.�' 19. Specified tee sizes are proper, gas baffle on outlet tee / 20. Sewage is under 10,000 gpd for parcel .!' 21.No garbage disposal 22. System adequately sized for its intended use % u_ ,' �- 23.Minimum 6"stone or compacted below tank and dbox i � 24.Manhole covers within 6"of grade,pump chamber cover to grade ;,,/- 25.Inspection port on plastic chambers/leach field --t------ 26.Electrical permit for pump chamber/Separate meter for duplexes L------ 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed ‘... -*- 29. _ '29.Vent provided if leaching below 3 feet, under driveway/parking \...---" 30.Buoyancy calculations for tank/pump chamber / � - 31.Engineer to inspect and certify soils: 1l: commercial: •_....----- 32. --- 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee, installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house --'f y 36.Deed Restriction required max. #bedrooms: max. flow: gpd -------. 37.Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: eit>i'' 6/03/03