Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 70 Lot 2- (0 Zone of Contribution: In Out I/Acreage Commercial: Residential: Street: /G S /1/c eci c /Wq r,) ,S7 3 Village: xtaf V�5i,.,.yl. c__,..)Floor Plan: #Bedrooms: s Owner: y�<;�,c.., .-,p,2t-- ISS' Installer: ( `, Address: AinE' 7 . s----z Phone: Phone: Builder: Engineer: .M 0`fE', Iv Address: �..y,..� -�''' Phone: g 9 _ it G/ Phone: _ N/A YES NO 1.Required#of copies received C.. 2.Date of soils exam and percolation test not older than 2 years al 2 ///! I, 3.4-5 ft of naturally occurring pervious material,above water table ✓ ✓ 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: V 6.Benchmark indicated and shown-NGVD if near wetlands _ V 7. Septic tank minimum 10 ft from foundation, deck Var.: V /7.a P 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: t, •Ve.4./5" 9.Leaching minimum 100 ft from wetlands Var.: ✓ y 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: j/ 11.Tank/leaching minimum 10 ft from property line Var.: L/ 26.21)' 12. System meets all other setback requirements Var.: / 13.Uses adjustment for maximum high groundwater Var.: ✓ 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: V /9t1 15.System not in top or subsoil(A,B horizons)or 5'removal Per c 6 ✓ _ 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", IA"preferred f .ye.- 18. System meets breakout requirements PVC liner: Wall: / 19. Specified tee sizes are proper, gas baffle on outlet tee 1/ 20. Sewage is under 10,000 gpd for parcel 1/ 21.No garbage disposal V 22. System adequately sized for its intended use .# 23.Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade,pump chamber cover to grade / 25.Inspection port on plastic chambers/leach field / 26.Electrical permit for pump chamber/Separate meter for duplexes / 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size J 28. Septic tank/pump chamber to be factory waterproofed ✓ 29.Vent provided if leaching below 3 feet,under driveway/parking V 0 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: / 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature / 33.H-20 loading is subject to vehicular traffic, groundwater L Vc, 6-) 17 34.Title V Application and permit fee,installer signature / n 35.Foundation footing min.2 feet above adjusted ground water for new house V 476 36.Deed Restriction required max. #bedrooms: max.flow: gpd ✓ 37.Check area lots for groundwaat�er//Label/groundwater in Assessor's Map J le- Plan reviewed by: i 4, /I vi,,/ / 669"/ 6/03/03