HomeMy WebLinkAboutPETITION VCOD 2017-2 DECISION WITH ATTACHMENTS 122917 T O W N O F Y A R M O U T H 1146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 02664-4492 Telephone (508) 398-2231, Ext. 1276, Fax (508) 398-2365 MEMORANDUM To: Planning Board From: Kathy Williams, Town Planner Date: December 15, 2017 Subject: 1121 Route 28 – VCOD Mixed Use Development Assessor Map 50, Parcel 108 A. General Description: The applicant is proposing a mixed-use development under Section 414 – Village Center Overlay District (VCOD) – VC4, to be located at 1121 Route 28. The applicant is proposing to retain the existing office building on the property, re-configure the parking and Wood Road access, and add 9 residential units in three buildings with associated utilities and site work on 1.78 acres (5.1 units/acre). The existing building will remain as office space and the drive-thru will be enclosed for use as additional office space. The pavement for the drive-thru will be eliminated and a new access off Wood Road created. The project will also utilize the existing Route 28 access and provide a total of 27 parking spaces, including two handicap spaces. The existing on-site septic will remain for use by the office building and a new septic system is proposed for the nine (9) new residential units. New stormwater management systems will be provided and water to the new condominiums is proposed to be accessed off Wood Road. The project is proposed to be constructed in two phases with the condominiums being part of Phase II. The project is proposing to be developed under the Village Center Overlay District (VCOD), VC 4, which allows for mixed use with up to 16 units/acre (5.1 units/acre proposed). One unit needs to be affordable. B. Process - VCOD Site Plan Review: The Planning Board reviews the project for compliance with the VCOD Design Standards is Section 414.8. This is not a Special Permit Decision and does not grant any zoning relief or make any zoning determination. The applicant has the right to appeal the decision of the Planning Board to the Zoning Board of Appeals. Any zoning relief required would be done through the Zoning Board of Appeals (ZBA). Planning Division Page 2 of 4 Planning Board 1121 Route 28 December 15, 2017 C. Comments from Other Committees: 1. Site Plan Review (SPR) and Design Review Committee (DRC): Please note that many of the comments from SPR involve noting other regulations or codes that the applicant must adhere to and not something that is required by zoning. a. Building: The Building Commissioner outlined the areas requiring relief including for the non-conforming location of the existing structure and to condominiumize the project. Applicant must address all Building Code and AAB regulations. b. Housing: One of the units needs to be affordable. There are multiple options outlined for meeting this requirement including a cash payment in lieu of creating an actual unit. c. Planning: Edits to the site plans have been made to address most of the SPR comments including modifications to the pedestrian connectivity; condenser locations/screening shown; 4’ catch basin sumps; and photometrics. Items remaining include: relocation of Reserve Area for the septic system outside required 20’ buffer; supplemental plantings within the center of the development to compensate for the loss of larger diameter trees; and provisions for future sewer connection to Route 28 (although most of the route would be under walkways and vegetated areas). d. Design Review: For VCOD projects, compliance with the Architectural and Site Design Standards are mandatory. The DRC noted numerous items where the standard could be met if the applicant made certain modifications. The applicant addressed DRC comments regarding building modulation; correction to roofline of the staircase dormer; and enlarging the dormer over the front entrance. However, the following items were identified in Design Review as being required to meet the standards, but were not included on the final architectural plans submitted to the Planning Board:  Denote on the plans that the columns on the front entrance shall have an overall 8” square dimension when trimmed out with azek.  Denote on the plans that window trim shall be 1”x4”.  Provide and denote on the plans 1”x8” frieze board.  Note all trim to be azek.  Denote on the plans that window grills shall be 5/8” contoured grill (rather than flat).  Note on the plans red cedar clapboards stained gray.  Provide a covering over the back door entrance to the two units facing the parking areas.  Dimensions on the elevations to show height. e. Engineering: Applicant to verify turning radii; ensure AAB compliance; provide for adequate snow storage and provide Phase I erosion control measures to protect natural infiltration area (DA6). f. Fire Comments: Applicant must address all fire code regulations; turning radii for fire vehicles; and chemical storage. g. Health Comments: Applicant must address all Health Department regulations. Page 3 of 4 Planning Board 1121 Route 28 December 15, 2017 h. Water: Provide proper water/sewer separation; implement backflow preventers on irrigation system; and consider the addition of a fire hydrant within the development. D. Planner Comments: The following is suggested language for consideration by the Planning Board should the Board wish to vote on this project at the December 20, 2017 meeting. These conditions are intended to address comments from SPR/DRC which were not incorporated into the drawings: On a motion by___________, and seconded by__________________, the Planning Board voted (?-?) that the project at 1121 Route 28 as presented at the Planning Board meeting of December 20, 2017 and in accordance with the plans and materials submitted is in compliance with the VCOD Design Standards and is subject to the following conditions: 1. All materials and finishes as depicted in the enclosed plans, and presented and approved by the Design Review Committee (DRC) and Site plan Review (SPR) Team shall be included in the project, including, but not limited to: a. All sidewalks to be concrete. b. Retaining wall to be stone faced. c. Columns on the front entrance shall have an overall 8” square dimension when trimmed out with azek. d. Window trim shall be 1”x4”. e. 1”x8” frieze boards shall be provided. f. All trim to be azek. g. Window grills shall be 5/8” contoured grill (rather than flat). h. Siding to be red cedar clapboards stained gray. i. Door landings to the two units facing the parking areas shall have a roof or covering to protect from the elements. 2. Landscaped areas to be irrigated. 3. Septic Reserve Area to be located outside the 20’ buffer area required adjacent to residential zoning districts. 4. The project is required to have one affordable unit in accordance with Section 412. 5. The site design shall ensure turning movements for fire and emergency vehicles. 6. Phase I erosion control measures shall be provided to protect natural infiltration area (DA6). 7. A fire hydrant shall be provided within the development. Page 4 of 4 Planning Board 1121 Route 28 December 15, 2017 Attachments:  VCOD Site Plan Review Application, including: Narrative dated October 5, 2017 and October 17, 2017; and Aerial & Locus Maps  Site Plan Review Comment Sheet dated November 14, 2017  Design Review Committee Comment Sheet dated November 1, 2017  Material Cut Sheets  PLANS: o Site Plans – All plans entitled “Site Plan of Land of #1121 Route 28 South Yarmouth, MA - Wood Road Condominiums prepared for Shoestring Properties LP”, prepared by Down Cape Engineering and dated and stamped December 6, 2017, unless otherwise noted below:  Sheet 1 of 6 – Layout/Landscape  Sheet 2/6 – Utilities/Grading  Sheet 3/6 – Existing Conditions  Sheet 4/6 – Erosion Control  Sheet 5/6 - Septic Detail Sheet  Sheet 6/6 – Detail Sheet o Architectural Plans – Existing Building – All plans entitled “Building Plans of #1121 Route 28 South Yarmouth, MA prepared for Shoestring Properties, LLC”, prepared by Down Cape Engineering, and dated and stamped October 5, 2017:  Existing – East, West and South Elevation  Existing – North Elevation & Floor Plan  Proposed – North Elevation & Floor Plan  Proposed – East, West and South Elevation o Architectural Plans – Proposed Building – All plans entitled “Proposed Townhouses for Shoestring Properties LP #1121 Route 28 South Yarmouth Massachusetts”, prepared by DP Architect, and last revised November 12, 2017:  A-1 – 1st Floor Plans  A-2 – 2nd Floor Plans  A-3 – Exterior Elevations  A-4 – Exterior Elevations 10/30/2017 Design-Pro Fiberglass Glass Panel Exterior Door | JELD-WEN Windows & Doors http://www.jeld-wen.com/en-us/products/exterior-doors/styles/glass-panel/design-pro-fiberglass-glass-panel-exterior-door#/group=All&model=modelM0…1/1 DESIGN-PRO FIBERGLASS GLASS PANEL EXTERIOR DOOR Design-Pro Fiberglass Glass Panel Exterior Door Price Range: $$ MODEL FIR 1/2 VIEW 9-LIGHT 2-PANEL WAYS TAAO BUY THIS PRODUCT FIND A STORE (/EN-US/FINDASTORE?URI=) The JELD-WEN Design-Pro Fiberglass doors feature the beautiful appearance of Mahogany, Oak or Fir woodgrains. Glass options include pet panel, blinds between the glass, energy efficient, decorative, direct glaze, or privacy glass. FEATURES ENERGY STAR® Qualified Options: yes Finish Options: ready to paint or stain Glass Options: energy efficient, protective, privacy, direct glaze, decorative, blinds between the glass Maintenance Level: minimal Project Type: new construction and replacement Sizes: Typical sizTTes include 3’0” X 6’8”, 3’0” X 8’0.”” For detailed available sizing please contact your Dealer.rr Warranty:limited lifetime Woodgrain Options: mahogany, oak, fir Back to Top TT  (/en-us/) Sheet 1 of 4Drawing No.Not for ConstructionSheet ContentsRevised: Nov. 12, 2107Date: May 13, 2017Drawn by: DRPConcept DrawingA-11st Floor PlansScale: 1/4" = 1'-0"Graphic Scale0155102025 Concept DrawingNot for Construction2nd Floor PlansDate: May 13, 2017Sheet 2 of 4Drawing No.A-2Drawn by: DRPSheet ContentsRevised: Nov. 12, 2017Graphic Scale0510152025Scale: 1/4" = 1'-0" ExteriorConcept DrawingDate: May 13, 2017Not for ConstructionSheet 3 of 4Drawing No.A-3Drawn by: DRPSheet ContentsRevised: Aug. 16, 2017ElevationsScale: 1/4" = 1'-0"Graphic Scale0155102025Nov. 12, 2017 Sheet 4 of 4Date: May 13, 2017ElevationsSheet ContentsDrawn by: DRPA-4Drawing No.ExteriorNot for ConstructionConcept DrawingRevised: Nov. 12, 2017Scale: 1/4" = 1'-0"Graphic Scale0510201525