Loading...
HomeMy WebLinkAboutEngineered Plan - 2019TOP FOUND. EL. 58.4' PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE uIKU11 W SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH. MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM PRECAST H-10 MORTAR ALL DL.U%.r\a "" RISERS (7YP.) COMPONENTS PRECAST RISERS 2'0 56 7' 4"S�SCH40 PVC H-20 ' PIPES LEVEL 1ST 2' 6" MIN. SUMP q' 5' (TYP.) 5' 12" MIN. INT. DIM. ENDS ri BET. HS16ES5 1 EXISTING 14" :P;o�=s�;s;a, . 00000000 10" 1 O O O O 's I UO °e:O i TEE SEPTIC TANK** TEE 55.4'* ° ° ° ° ®®®® ®®®® '0,000N..0 o a o ®��® _®11 00000000 o0 0 0 D > o 0 0 0 j_,'0R_�_,,?0,eo_0o? °°°o°° WATERTEST D'BOX ;00000000 . ®®�®®®®®®® o10 ®®®®®®®®��0 ;00000000GAS BAFFLE°° FOR LEVELNESS °°°°°°°° ®®®®®®®®®®® °°0®®® ° ° 00000000 ®®®®�®®��®® 000000 ®®®®D®®®®�® 0000000°o°o°o° °°o°o°. °a°o 5 55.154.95 • 6" MIN. SUMP 12" MIN. INT. DIM. t I L H-20 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. 3/4"-1-1/2" DOUBLE WASHED STONE (2) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 30' X 9.83' COMPACTION. (15.221 [21) � ori (—Z—% SLOPE) (2 % SLOPE) FOUNDATION EXIST. SEPTIC TANK 14' D' BOX 17' LEACHING FACILITY 47.0' BOTTOM TH-1 NO GROUNDWATER FOUND *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS 1000 GALLONS AND ITS SUITABILITY FOR RE—USE. REPLACE PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE LEGEND _99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[99]-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 Y TEST HOLE 2Y2% SLOPE OF GROUND C -0-D UTILITY POLE V FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 AMY .VON HONE, RS WITNESS. DATE: 7/24/2019 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS . ELEV. o„ 4 58' FILL 12 $1 2" LS 1OYR 2/2 B LS 1OYR 5/8 C MS 1OYR 7/4 24" 33" 55.2' PERC 132" 47' NO GROUNDWATER ENCOUNTERED DCE #19-23> 0 49 V_ yI ELECTRIC `METER ) / BENCHMARK: MAG NAIL = 59.1' NAVD88 55 56 7 LOT AREA 10,095±S.f, i 100 00' CARL s Y 9 � \W < W ,uo, 2 i " O t\ S;74,4.08) 3 4'e 100 oo, 58 SRR Y W \\W\.�. NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-24 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE ' WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4". PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1a): REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 4.1') EXISTING DWELLING TOF=58.4 j PORCH / 7 / p a� I Scale:1 "= 20' 0 10 20 30 40 50 FEET R a s- fe 6.4 a 7 o o v 0 Locus ooh �i moa i / i / 0 3 xit 0 Route 6 a. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING AND VERIFYING ITHEFLOCATION OF ALL UNDERGROUND & LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1"=2000'± WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 115 PARCEL 193 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (AREA OF MINIMAL FOOD HAZARD) AS AND REMOVED OR PUMPED AND FILLED WITH CLEAN SHOWN ON COMMUNITY PANEL #25001 CO578J SAND. DATED 7/16/2014 SITE IS WITHIN ZONE 11 SYSTEM DESIGN: • GARBAGE DISPOSER IS NOT ALLOWED BED ROOM DINING. zo ROOM DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD 0 GARAGE 1/2 J� USE A 330 GPD DESIGN FLOW BATH I KITCHEN BATH HALLWAY SEPTIC TANK: 330 GPD (2) = 660 **RE -USE EXISTING 1000 GAL. SEPTIC - TANK BED BED ROOM ROOM LEACHING: SIDES: 2 (30 + 9.83) 2 (.74) = 118 GPD FLOOR PLAN BOTTOM 30 x 9.83 (.74) = 218 GPD NOT TO SCALE 454 S F 336 GPD Permit valid. for -REPAIR- OF SEPTIC_ SVS1'FM'.. ONLY,- dile to 'State and Local septic'; variances:` Board of Ilealth review and approval is required for any 6tore additions/renovations/alterations to sewage facilities and/or str.uihu es/dwelling. Yarmouth Iteal((tti I)epartiitent 'PR®VE ". 7/:Oat -7 -_Lr, DATE TOTAL: USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 2.5' STONE AT SIDES, 4' AT ENDS AND 5' BETWEEN UNITS APPROVED • 'DATE BOARD OF HEALTH � MA TITLE 5 SITE PLAN OF #52 EARLY RED BERRY LANE YARMOUTH PORT, MA PREPARED FOR DANIEL A. OJALA, P.E.,. P.L.S. BETH STANDRING DATE: JULY 26, 2019 off 508-362-4541 fax 508-362-9880 ` downcape.com down cdpe engineerin60, Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 19-231 STANDRING.DWG