Loading...
HomeMy WebLinkAboutEngineered Plans - 2019LEGEND --[�--1 PROPOSED CONTOUR ® PROPOSED SPOT GRADE -- g$ -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE —W— EXISTING WATER SERVICE TEST PIT SCALE: 1'=20' 1`4R YARMOUTH LOCUS LOCUS MAP 6d 00 LOCUS INFORMATION 3e 45 . / PLAN REF: 278/041 j O TITLE REF: 5461/0281 j O PARCEL ID: MAP 116 PAR. 087 ° /45.G FLOOD ZONE: PROPERTY NOT IN FLOOD ZONE 45.7 6430, r O F�F 45. C. 4)O4)0 41 .5 LOT 1 AREA=0.25 ACRES r, 39.8 0 A sOa /32 00 vent N 4G 48 Permit valid for REPAIR OF SEP'T'IC SYSTEM ONLY, due to State and Local septic variances. Board of health review and approval is required for any future additions/renovationsi;eiterations to sewage facilities and/or structures/dwelling. Yarmouth health Department APPROVE id LICT Date OF �S,,0 Fa i SIRv 35J 1 Q N0. 0 :P 10 --6- k9 SURVEY CONDUCTED BY: WELLER AND ASSOCIATES SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 165 WEIR ROAD YARMOUTHPORT, MA PREPARED FOR BART GUINEY/ READY ROOTER EXC. OCTOBER 2, 2019 MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5@gmail.com Raba 894 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS SEPTIC TANK INSTALL RISERS & COVERS OVER INLET & PROPOSED D -BOX T.O.F. EL=47.0± OUTLET AND SET TO 6" OF FINISH GRADE INSTALL RISER & COVER INSTALL LOCKING COVERS IF AT FINISH GRADE SET TO 6" OF GRADE /-F.G. EL.=41.50± /- F.G. EL.=39.8± r-F.G. EL: 40.0± 9' MIN COVER/ O S=1X (MIN.)E�38.� O S 1X (MIN.) 4`SCH40 PVC _. 4"SCH40 PJC INV.=37.45)- I 48. 1 [EAE[ INV.=37.20 \ .. CIS BAFFLE.. INV.=36.90 EXISTING 1.000 GALLON SEPTIC TANK I EXIST. SEWER OUTLET I NOTES: 1) CONTRACTOR SHALL. VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) REPLACE EXISTING 1,000 GALLON SEPTIC TANK WITH 1500 GALLON SEPTIC TANK IF FAILED, DAMAGED OR UNDERSIZED. JT4jSiT"j�A e e, L L - 10'(MAX 4 "SCH40 S-Ix(MPV C) 73 BREAKOUT=TOP ELEV.=37.02 INV. ELEV.= 36.63 BOTTOM ELEV.= 35.69 NOTE. TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL -37.02 FOR A DISTANCE OF 15' AROUND THE PROPOSED S.A.S. PERIMETER OF THE S.A.S. INSTALL A 4" DIAMETER INSPECTION PORT OVER ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. VENT /-F.G. EL: 43.0(MAX.) 5' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. (6.79' PROVIDED) BOTTOM OF TESTHOLE: EL -28.90 - 4) INSTALL INLET & OUTLET TEES W/ SEPTIC SYSTEM PROFILE GAS BAFFLE AS REQUIRED N.T.S. DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOM DESIGN (NOT IN ZONE 11) DESIGN FLOW: RESIDENTIAL: 3 BEDROOMS O 110 GPD/BR = 330 GPD DESIGN PERCOLATION RATE: <2 MIN/IN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) GARBAGE GRINDER: NO (not designed for garbage grinder) DISTRIBUTION BOX: USE DB -5 (H20) SEPTIC TANK: 330 gpd x 200% - 660 gpd USE EXIST. 1,000G SEPTIC TANK LEACHING AREA REQUIRED: (330)/.74 - 445.94 S.F. PRIMARY S.A.S. USE 4 ROWS OF 4 - HI -CAP INFILTRATOR H-20 UNITS -NO STONE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) (CHAMBER) 16 UNITS x 6.25 LF x 4.73 SF/LF = 473 SF TOTAL AREA = 473 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(473SF) = 350 GPD > 330 GPD req'd INSTALL TWO INSPECTION PORTS (MIN.) 4 ROWS OF 4 UNITS AT 6.25/UNIT = 25'/ROW SOIL ABSORPTION SYSTEM (PROFILE) VEGETATIVE COVER PLACE FILTER FABRIC OVER ALL UNITS PRIOR TO BACKFILL EXISTING SUITABLE MATERIAL EFFECTIVE WIDTH = 4 x 2.83' = 11.3 USE 4 ROWS OF 4 -HIGH CAPACITY INFILTRATOR (H20) UNITS TYPICAL SECTION x TA SOIL LOGS DATE: SEPTEMBER 19, 2019 SOIL EVALUATOR: DARREN M. MEYER, RS, CSE 1614 WITNESS: PHIL RENAUD, YARMOUTH HEALTH GENERAL NOTES: I. ALL CHANGES TO THIS PIAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE. TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REOUESIED BELOW: - 310 CMR 15.405 (1) (B): 1) A 298 FL VARIANCE FRDM 3100MR15.221(7) TO ALLOW LEACHING TO BTL 5.98 Fr (MAX) BELOW GRADE VS ROWD 3 FT. (H20/VENT PROVIDED) 3. THE SEWAGE DISPOSAL SYSTEM SHALL HOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE THMP�TO N THE LOCAL BOARD OF HEALFORROPER INSPECTIONS WNG CONSTRUCTION. 7. DWELLING IS SERVICED BY TOWN WATER. B. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT Stall BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES. PRIOR M STARTING WORK. 10. EXISTING LEACH PIT TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO KNOWN PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 O 1/8"/Fr (UNLESS SPEC. ) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW '\FOR THE USE OF A GARBAGE GRINDER. �yG 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING M. N 75` Elev. TP -1 Depth El". TP -1 A D 0. 39.40 0" 42.70 FILL LOAMY SAND 10YR 5/8 16" 97% 32.0788` 40.87 22" 1 17-0 B 10YR %6DLOAMY SAND 31.32 97• IGYR 5/4 LOAMY SAND 39.37 40" SECTION f1• C tOYR 7/1 INVERT HEIGHT END CAP 29.65 717" pERC a MEDIUM B MEDIUM EL 37.20 SAND INFILTRATOR - HI CAPACITY (H2O) CHAMBER 2.SY 8/2 SAND 10YR 5/8 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 28.90 126" 32.70 120" PERC PATE <2 MIN/IN. (`C• HORIZON) NO GROUNDWATER OBSERVED • 1. Damm M. Meyer, RS.. CSE, hereby certify Mat I am currently approved by MADF.P Pursuant to 310 CMR 15.017 to conduct soil evatuadone and Mat the above analysis tm been perfar ad by me aoneletent with tbe repWnmenG of 310 CMR 15.017. 1 further certify Mot I have paeaed the Soil Evac. Exam in October. 1999. 165 WEIR ROAD, YARMOUTHPORT, MA Prepared for. Guiney/Re dRooter Exc. Design and Site Plan by: SCALE DRAWN DATE MEYER& SONS, INC. N.T.S. DMM 10/02/1 PO BOX 981 EASTSANDW/CH, M402537 CHECKED SHEET NO. 50"62-2922 DMM 2 of 2