Loading...
HomeMy WebLinkAboutEngineered Plan - 200023.5 MANHOLE COVERS TO EXTEND TO WITHIN 6" OF FINISH GRADE 10' MIN. --� _2% f 22.9 u EXISTING U bi 1,000 GAL r o TO REMAIN 26' 5 BAFFLE REQ'D /NEW DIST. BOX REQ'D 1"0 3 D. B. 1%_ 22.63 22.46 1O' 6' CRUSHED TONE 3' 20' MIN. SOIL TEST LOG P 13C RATE= < 2 MIN/INCH PROPOSED SEPTIC SYSTEM NO SCALE DwPT0 4. P4_ _ 24.8 A;E LOAMY SAND 1OYR 4/1 ,.. 7 t I_OAMY SAND 1QYR 6/6 .. .22,^6 —� Q i MEDIUM SAND 10YR 7/6 - — C2 MEDIUM SAND IOYR 8/1 ' i28.. . r �a t13 SOIL TIE -ST CONDUQTFD ON, MARCH 4, 2000 BY :HUNTER ENGINEE WITNESSED BY: KE A HOLGREN, AGENT YARMOUTH HEALTH PARTMENT NO WATER OBSERVED @ 128" PERC BOTTOM @ 40" LEGEND: EXISTING CONTOUR EXISTING SPOT ELEV 24.7 WATER GATE a— W. M. WATER SERVICE _w_W_ TEST HOLE GAS SERVICE _G_G BENCH MARK 0� 31 BM 24 — 24.4 A 0 a C) 21.59 M LOCUS (SAS) SHALL BE 34.25' LONG 11.0' WIDE q 10" DEEP o <<Fr o NEV` (SAS) _;�i �` : :ui:::-�. :+oi: i:.'•::Ui �: uc 2" P EAS TO N E TOPPING CAP ENDS J 3 4" DOUBLE WASHED STONE ALL AROUND LOCUS MAP GENERAL NOTES: 31.25' ji 5' — ELEVATIONS SHOWN BASED ON U.S.G.S. DATUM. SYSTEM PIPE SHALL BE EITHER C.I. OR USE FIVE (5) INFILTRATORS SCHEDULE 40 P.V.C. WITH 4' OF STONE @ SIDES — THE BOARD OF HEALTH SHALL BE NOTIFIED & 1.5' OF STONE @ ENDS PRIOR TO BACKFILLING OF SEPTIC SYSTEM. NOTE: PRIOR TO INSTALLING THE NEW (SAS) THE �— CONTRACTOR SHALL PUMPOUT ! EACH PIT AND BACK FILL WITH CLEAN MEDIUM SAND 24.8 it 25 - \v MARCHANT N/A PLAN 1 it = 20' MOB 0. F� � � HUN i`ER u <� SYK%3 n GIV!! R 005413 (r No. 36145 a � 9FS71 — SEPTIC SYSTEM STRUCTURAL COMPONENTS SHALL BE CAPABLE OF WITHS7ANDING A H-10 LOADING, UNLESS SPECIFIED OTHERWISE — SEPTIC SYSTEM UNDER DRIVEWAYS SHALL COMPLY WITH A H-20 LOADING. — THE DESIGN AND COMPONENTS OF THE SEPTIC SYSTEM SHALL BE IN COMPLIANCE WITH THE STATE OF MASSACHUSETTS SANITARY CODE TITLE V, AND SHALL BE IN COMPLIANCE WITH THE LOCAL BOARD OF HEALTH RULES AND REGULATIONS. — THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATION OF ALL UNDERGROUND UTILITIES AND Ji-1HLL ..� i i� 1• Usry —• .�N:' � ii�il.ii� i CONSTRUCTION. NO GARBAGE GRINDER DESIGN CRITERIA: DESIGN FLOW 3 BEDROOMS AT 110 G.P.B. / DAY 330 G.P.D. REQUIRED SEPTIC TANK: USE EXISTING 1.000 SR�LTIC TANK PROVIDED NONE DESIGN PERC RATE <2 MIN/INCH SIZE OF REQ'D (SAS) AREA = 330/0.74 = 446 S.F. SIDEWALL (2)(0.83)(34.25)+(2)(0.83)(1 1)=75.12 S.F. BOTTOM (11)(34.25) = 376.75 S.F. SIZE OF LEACHING FACILITY PROVIDED: 376.75 S.F. + 75.12 S.F. = 451.87: S.F. 334.4 GPVr EFFECTIVE DEPTH: 10" EFFECTIVE LENGTH: 34.25' EFFECTIVE WIDTH: 11.0' I-FA CONSULTING ENGINEERS E c E 7 WEEKS POND DRIVE SANDWICH, MA 02601 MAR 17 2000 (508) 477-8268 Hunter Engineering Associates, inc. HEALTH DEPT. PROJECT: SEPTIC SYSTEM REPAIR 6 MARCHOANT WAY SCALE: AS SHOWN DRAWN BY: JPH DATE 3/15/00 NEW MAP 47 / LOT 24 REVISED BY: OWNER: ROBERT DIVERDI 159 OLD MILL ROAD SHREWSBURY, MA 01545 FN E: MARCHANT