HomeMy WebLinkAboutAir Leakage Report 411D - 1D , 001-t6‹. s' HOME ENERGY RATERS L LC BUILDING PERFORMANCE TESTING Air Leakage Report 237 Main Street Test Mode Yarmouth Depressurization 05/28/2019 Test Pressure Lohr Construction 50.0 Pascals Test Equipment 2009 IECC Energy Code Retrotec RECEIVEf BUILDING DEPARTMEN"T By J Total Air Leakage Or Air Changes Per Hour Gauge 864 2.59 Conditioned Volume 20000 This project meets the criteria for the following: 2009 International Energy Conservation Code 2012 International Energy Conservation Code 2015 International Energy Conservation Code 180 STATE ROAD SUITE 2U SAGAMORE BEACH,MA 02562-(508)833-3100-ENERGYCODEHELP.COM-INFO@ENERGYCODEHELP.COM powered bycgocanvos www.gocanvas.com �_. >_3 •• HOME ENERGY RATERS L LC BUILDING PERFORMANCE TESTING Duct Leakage Report 237 Main Street Test Mode Yarmouth Depressurization 05/28/2019 Test Pressure Lohr Construction 25.0 Pascals Testing Equipment 2009 IECC Energy Code Minneapolis 111 Total CFM@25 or Total Duct Leakage Percentage 72.00 0.03 Total Square Footage 2300.00 Maximum Allowable Leakage 92.00 HVAC Duct Test Mechanical Room 2300 B 72 0.03 180 STATE ROAD SUITE 2U SAGAMORE BEACH,MA 02562-(508)833-3100-ENERGYCODEHELP.COM-INFO@ENERGYCODEHELP.COM powered by gocanvos www.gocanvas.com ,• -� ._ • HOME ENERGY RATERS L LC BUILDING PERFORMANCE TESTING Ventilation Report Ventilation Tests 1st floor bath 75 6 hrs - coNflG tons 2nd floor bath 73 6 hrs ME AVG UNITS caries u.,.. n.,. 180 STATE ROAD SUITE 2U SAGAMORE BEACH,MA 02562-(508)833-3100-ENERGYCODEHELP.COM-INFO@ENERGYCODEHELP.COM powered bycgocanvas www.qocanvas.com - - •• HOME ENERGY RATERS L LC BUILDING PERFORMANCE TESTING Compliance Option t1: Follow these steps to determine compliance for the fan Airflow. 1) Determine the floor area of the conditioned space of the home=(A ) 2) Determine number of Bedrooms.al&.f) 3) Insert these number in the formula Below: Fan airflow(CFM)=0.01Anoor+7.5(Na+1) Fan Airflow for Homes with Average Air Leakage Floor Area(ft2) No.Of Bedrooms 0-1 2-3 4-5 6-7 >7 <1500 30 45 60 75 90 1501-3000 45 60 75 90 105 3001-4500 60 75 90 105 120 4501-6000 75 90 105 120 135 6001-7500 90 105 120 135 150 >7500 105 120 135 150 165 Fan airflow is CFM. Chris Mazzola RTIN# 8873503 •Z 180 STATE ROAD SUITE 2U SAGAMORE BEACH,MA 02562-(508)833-3100-ENERGYCODEHELP.COM-INFO@ENERGYCODEHELP.COM powered by goconvos www.Boca nvas.com