Loading...
HomeMy WebLinkAboutReview Checklist Neem C S TOWN OF YARMOUTH ja binP� SEWAGE PLAN REVIEW CHECKLIST c.S 8 Lot PIE/'^• I'c Location: A.M. 7 es Zone of Contnbution: In Out- Acreage Commercial: Residential: /V Street: 6 ZCie, i1 ri< . Village: Sof -/ re� i nRJ),•2Q..,17,( Floor Plan: 17 #Bedrooms: 1-71 Owner: 49;71 3r ady Installer: t2c,her-f 3. O()� co.. Address: Phone: ,5c,ce, y 3 Z, -,x 5 3 0 Phone: /� Builder: Engineer: 7"-v/)7 /Yt A2/J4,,7 Address: Phone: bbs 3 ee y 90 yS . Phone: 444a l . G rot..,d ,lt� N/A YES NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years 8-'-j I ,� 3.415 ft of naturally occurring pervious material, above water table V 4.Foundation 2 ft above high point of road . H.P.: Fnd: Var.: ✓ 5.Water line 10 ft from septic components Var.: ,a„r V 6.Benchmark indicated and shown-NGVD if near wetlands / 7. Septic tank minimum 10 ft from foundation, deck Var.: l 5 I 'V 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: a.B ' V 9.Leaching minimum 100 ft from wetlands Var.: 1 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: l/ 11.Tank/leaching minimum 10 ft from property line Var.: /' 12. System meets all other setback requirements Var.: ,/ �r 13.Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: X2. 15. System not in top or subsoil(A,B horizons)or 5'removal Y ie._. ‘S- ✓ Illak16.Proposed contours are suitable Ive \-- 9" coe -iNl* IX) 17. System meets slope requirements-min. 1/8", 1 "preferred $./` - 18. System meets breakout requirements PVC liner: J Wall: V 19. Specified tee sizes are proper, gas baffle on outlet tee ✓ • 20. Sewage is under 10,000 gpd for parcel 11941 GPD. ✓ 21.No garbage disposal ✓ 22. System adequately sized for its intended use ✓' 23.Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade,pump chamber cover to grade ✓ 25.Inspection port on plastic chambers/leach field / 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ✓ 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet,under driveway/parking J 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: ✓ - 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature LS 5h-10 0 33.H "-20 loading is subject to vehicular traffic,groundwater T!/ 34.Title V Application and permit fee, installer signature ,7 35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: 6/03/03