HomeMy WebLinkAboutReview Checklist • f e
SEWAGE PLAN REVIEW CHECKLIST
Location: AM g LOT SI Date of Subdivision Approval
Street /$ S,Kpyh,dVfAiuE Zone of Contribution: In )( Out
Village WEsr lem4u7H Commercial Residential )(
Owner .A( ► x-17"14 TH` 12LAGY Installer BEiiW (7, 1455/44/6
l &' Poud S,r E,DsrEev,uE, A4
BuilderT VdemHILiv.ppk Engineer bdr w CAPE Ev614EEeIAAi
J (o AlAw Sviri Yitei ou ni-Peet
N/A Yes No
1 . Required number of copies received. X
2. Date of soils exam and percolation test not older than 2 years. )X
3. 4 feet of naturally occcurring pervious material. X
4. Foundation 2 feet above high point in fronting road. X
5. Water availability letter from Water Department. �(
6. Benchmark indicated and shown. X
7. Building sewer does not exit center of house. X
8. Septic tank a minimum of 10 feet from house and deck. )(
9. Leaching a minimum of 20 feet (10 feet) from house and deck.
10. Leaching a minimum of 100 feet from wetlands. • X
11 . Leaching a minimum of 150 feet from wells. X
12. System meets all other setback requirements. X
13. USGS adjustment used for maximum high groundwater. �(
/ 14. Leaching 4 feet above adjusted water table or bottom of test pit. X
15. System not in top or subsoil or 10 foot removal.
16. Proposed contours are suitable. X •
17. System meets slope requirements. x
18. System meets breakout requirement. X
19. Specified tee sizes are proper. - X
20. Sewage flow not over 10000 gpd.
21 . No garbage disposal. X(
22. System adequately sized for its intended use. )(
23. Engineer to certify.
a. Clay removal. X
b. 25 foot removal.
c. Tight installation.
d. Commercial system.
24. Engineer and Land Surveyor Stamp and Signature. )(
25. H 20 Loading when system is subjected to vehicular traffic.
26. Title 5 application and fee signed by licensed installer )(
_
27. Foundation footing 2 feet above adjusted water table. X
aziezebrea,i4,,eaateno_
Plan reviewed by / e,
v
It ko 416.
2/4/881e64,4 `i
TH:fs �sz� .4 aN2F,4i,