Loading...
HomeMy WebLinkAboutReview Checklist SLE' . TOWN OF YARMOUTH �_ 1: SEWAGE PLAN REVIEW CHECKLIST �2� '' Location: A.M. e� Lot 22) Zone of Contribution: In < Out_ Acreage /����,, Commercial: Residential: �o - Street: i.(4/�rc,�- �_ Village: Floor Plan: ,_/#Bedrooms: Owner: 2Installer: "LI-ge.../X.7-17e, Address: Phone: - -77-5--9 7 Phone: Builder: Engineer: / ' Address: Phone: ._ ` Phone: ,---- //,, r)/ il 4etek a2 N/A S NO 1.Required#of copies received ,i 2.Date of soils exam and percolation test not older than 2 years L.------ 3.4-5 /3.4-5 ft of naturally occurring pervious material,above water table t---- 4. - -4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: L..---- 5. ,/5. Water line 10 ft from septic components Var.: t/ 6.Benchmark indicated and shown-NGVD if near wetlands L....-- 7. �7. Septic tank minimum 10 ft from foundation, deck Var.: 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: Z (----2 .--")A..---, • 9.Leaching minimum 100 ft from wetlands Var.: <......- 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: L� 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: L.� 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: t------ 15. System not in top or subsoil(A,B horizons)or 5'removal L------- 16.Proposed contours are suitable (...------ 17. System meets slope requirements-min. 1/8", '/a"preferred L_.----- 18. System meets breakout requirements PVC liner: Wall: (..---- 19. Specified tee sizes are proper,gas baffle on outlet tee L.....--' 20. Sewage is under 10,000 gpd for parcel l,--- 21.No garbage disposal C.i 22. System adequately sized for its intended use c----- 23.Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade,pump chamber cover to grade 4/ 25. Inspection port on plastic chambers/leach field L..---- 26. Electrical permit for pump chamber/Separate meter for duplexes 27. Pump system-2" line,weep hole,check valve,tee in dbox,pump size ,..-.-- 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet, under driveway/parking 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33. H-20 loading is subject to vehicular traffic, groundwater �" 34.Title V Application and permit fee, installer signature 35.Foundation footing min.2 feet above adjusted ground water for new house .1 36. Deed Restriction required max. #bedrooms: -p-max. flow: - gpd . - 37. 37. Check area lots for groundwater/Label groundwater in Assessor's Map ,/ Plan reviewed by: Q:/t. 6!03/03