HomeMy WebLinkAboutReview Checklist SLE'
. TOWN OF YARMOUTH �_ 1:
SEWAGE PLAN REVIEW CHECKLIST �2�
'' Location: A.M. e� Lot 22) Zone of Contribution: In < Out_ Acreage
/����,, Commercial: Residential: �o -
Street: i.(4/�rc,�- �_
Village: Floor Plan: ,_/#Bedrooms:
Owner: 2Installer: "LI-ge.../X.7-17e,
Address: Phone: - -77-5--9 7
Phone:
Builder: Engineer: / '
Address: Phone:
._ `
Phone:
,---- //,,
r)/ il 4etek a2
N/A S NO
1.Required#of copies received ,i
2.Date of soils exam and percolation test not older than 2 years L.------
3.4-5
/3.4-5 ft of naturally occurring pervious material,above water table t----
4.
- -4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: L..----
5.
,/5. Water line 10 ft from septic components Var.: t/
6.Benchmark indicated and shown-NGVD if near wetlands L....--
7.
�7. Septic tank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: Z (----2 .--")A..---,
• 9.Leaching minimum 100 ft from wetlands Var.: <......-
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.: L�
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.: L.�
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: t------
15. System not in top or subsoil(A,B horizons)or 5'removal L-------
16.Proposed contours are suitable
(...------
17. System meets slope requirements-min. 1/8", '/a"preferred L_.-----
18. System meets breakout requirements PVC liner: Wall: (..----
19. Specified tee sizes are proper,gas baffle on outlet tee L.....--'
20. Sewage is under 10,000 gpd for parcel l,---
21.No garbage disposal C.i
22. System adequately sized for its intended use c-----
23.Minimum 6"stone or compacted below tank and dbox
24.Manhole covers within 6"of grade,pump chamber cover to grade 4/
25. Inspection port on plastic chambers/leach field L..----
26. Electrical permit for pump chamber/Separate meter for duplexes
27. Pump system-2" line,weep hole,check valve,tee in dbox,pump size ,..-.--
28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet, under driveway/parking
30. Buoyancy calculations for tank/pump chamber
31. Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33. H-20 loading is subject to vehicular traffic, groundwater �"
34.Title V Application and permit fee, installer signature
35.Foundation footing min.2 feet above adjusted ground water for new house .1
36. Deed Restriction required max. #bedrooms: -p-max. flow: - gpd . -
37.
37. Check area lots for groundwater/Label groundwater in Assessor's Map ,/
Plan reviewed by: Q:/t.
6!03/03