Loading...
HomeMy WebLinkAboutEngineered Plans - 2009z rn �'�� OF METtK N o' 1140 "' 1 'SEG/STE0 J SNI \�p� S LEGEND GONS'(PNC� PROPOSED CONTOUR ® PROPOSED SPOT GRADE- - EXISTING CONTOUR SITE + 96.52 EXISTING SPOT GRADE m W EXISTING WATER SERVICE ® TEST PIT I( 3 c SHEFFIELo Ro T M v LOCUS MAP N.T.S. GENERAL NOTES: L 2ci._ 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL D F O'J �J G BOARD OF HEALTH AND THE DESIGN ENGINEER. . 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: — 310 CMR 15.405 (1) (B): 1) A 2 FT. VARIANCE FROM 310CMR15.221(7) TO ALLOW LEACHING TO BE Existing Leach Pit 18 FT FROM DWELLING VS REQ'D 20 FT. (Note 10) _ _ 2) A 0.11 FT. VARIANCE FROM 310CMR15.221(7) TO ALLOW LEACHING TO BE 3.11 FT BELOW GRADE VS REQ'D 3 FT. (H20/VENT PROVIDED) Permit valid for REPAIR Or SEPTIC SYS"fENI 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR CINLY, Cue to State 2-€d t-eca! sei.tic 11;_0:1'ces- TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE Esard of tlealth rev9e.» ^.nd approval is required DESIGN ENGINEER. for asiy future addit?ors/renob'atiors/zlterations to 4• ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN � ;.ataae faci?ities and/or structurt.•s/dwelling. ENGINEER BEFORE CONSTRUCTION CONTINUES, Yarmouth Health i3epat'tent 5. ALL ELEVATIONS BASED ON ASSUMED DATUM, C 5 � J �THE 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF CONTRACTOR OWNER NOTIFY LOCAL A OF / ION. HEALTH FORPRO ER NSECT ONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 2 ! �� 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. ' 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY e ' -' THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING CESSPOOL TO BE PUMPED, CRUSHED AND FILLED PER TITLE V. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY I ° AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY y 13. NO PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. All PIPING TO BE 4" SCH 40 {ID 1 /8"/FT (UNLESS SPEC. OTHERWISE) j 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 17. PROPERTY IS IN ZONE II (2BR DEED RESTRICTION REQ'D) 17. INSTALLER TO FIELD VERIFY H2O CERTIFICATION PRIOR TO INSTALLATION PROPOSED SEPTIC SYSTEM UPGRADE PLAN 28 FLICKER LANE, WEST YARMOUTH, MA. MAP: 086 _ Prepared for: Blue Water Septic LOT.• 222 Engineering - 'by: Surveying by: SCALE DRAWN DARRENM. MEYER, R. S. Weller and Assoc. 1 "=20' DMM POBOX981 EASTSANDWICH, MA 02537 Route 28 Centerville, MA 02632 DATE: CHECKED SHEET NO. 508-362-2922 (508) 775-0735 11/05/09 DMM 1 of 2 NOTE: TO PREVENT BREAKOUT, THE PROPOSED ' NOTE: MAGNETIC 'PAPE TO BE PLACED OVER ALL COVERS FINISH GRADE SHALL NOT BE < EL:24.39 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. SEPTIC TANK INSTALL RISERS & COVERS OVER INLET & PROPOSED D -80X PROPOSED INSTALL RISER & COVER INSTALL S.A.S. A 4" DIAMETER INSPECTION OVER. OF MASS9 T.O.F. EL=30.0 "PORT KIT eta BED OUTLET AND SET TO 6' OF FINISH GRADE SET TO 6' OF GRADE ONE CHAMBER (MIN.) AND SET TO 3 OF F.G. RM yeti �'y I�F.G. EL.=28.7± F.G. EL.=28,0± F.G. EL: 27.51 F.G. EL: 27.5-27.0 MAX. VENT ( ) GAR. j o/ DA f7EN �Eh R " No. 1140 y' LIV. BED 9" MIN COVER/RM ® S=1% (MIN.) 36" MAX COVER L m 10' L s 1O'(MAX) INSTALL TWO INSPECTION PORTS (MIN.) RM �Elrc� 0 S=1% (MIN.) 4"SCH40 PVC 4"SCH40 PVC 0 S=1R (MIN.) 4"SC/I PVC MNITAR�P� 10" t4• rs 11.3" TO •" INV.= 26.58 48" LIQUID INV.=26.33 INVERT FIRST FLOOR LEVEL GAS 13AFFLE 1 PROPOSED INV.=24.80 D -BOX 3 ROWS OF 5 UNITS AT 6.25'/UNIT + 0.75' WEDGE 32.0'/ROW INV.=25.0 DB -3(H-10 INV.= 24.0 SOIL ABSORPTION SYSTEM (PROFILE) EXISTING 1.000 GALLON SEPTIC TANK RESTORE VEGETATIVE COVER EXISTING SEWER OUTLET BACKFILL WITH CLEAN PERC SAND 75" TO TOP OF CHAMBERS NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING `': ' ., ; '`,:'.•` =' • ; PIPE INVERTS PRIOR TO CONSTRUCTION BREAKOUT=TOP ELEV.=24.39 ,. 2) D -BOX SHALL BE SET LEVEL AND TRUE TO INV. ELEV.= 24.0 GRADE ON A MECHANICALL COMPACTED SIX . BOTTOM ELEV.= 23.06 INCH CRUSHED STONE BASE, AS SPECIFIED IN EXISTING SUITABLE 310 CMR 15.221(2) 2.83' MATERIAL 3 REPLACE EXISTING 1,000 GALLON SEPTIC 5' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 3 x 2.83 = 8.49' I • 76" `I TANK WITH 1500 GALLON SEPTIC TANK (5.81' PROVIDED) USE 3 ROWS OF 5 -HIGH CAPACITY IF FAILED, DAMAGED, OR LESS THAN 1,000G IN CAPACITY. BOTTOM OF TESTHOLE EL.=17.25 - ADS BIODIFFUSER UNITS -NO STONE PROFILE 4) INSTALL INLET & OUTLET TEES AS REQUIRED _ W/ CONTOURED WEDGE SEPTIC SYSTEM PROFILE TYPICAL SECTION .16" N.T.S. N.T.9. 11.2" DESIGN CRITERIA SOIL LOG 34" � NUMBER OF BEDROOMS: 3 BR EXIST. DATE: OCTOBER 7, 2009 CLASS I SOIL EVALUATOR: DARREN M. MEYER, R.S., CSE. #1614 SECTION END CAP SOIL TEXTURAL CLASS: WITNESS: PHIL RENAUD, YARMOUTH B.O.H. DESIGN PERCOLATION RATE: <2 MIN/IN TP -1 16"" HIGH CAPACITY (H-20) BIODIFFUSER UNIT DAILY FLOW: 110 G.P.D/BR. Depth Elev. _� DESIGN FLOW: 330 G.P.D. 27'25 A LOAMY SAND 0" MODEL 16" HICAP GARBAGE GRINDER: NO NOT DESIGNED FOR GARBAGE GRINDER) ( 26.59 IO 4 8„ B LENGTH 76" SUBJECT PROPOSED SEPTIC TANK: USE EXISTING 1,000G SEPTIC TANK -SANDY LOAM 10YR 5/8 NOTE: UNIT CONFIGURATION AND AVAILABILITY EFFECTIVE LENGTH 75" TO CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY LEACHING AREA REQUIRED: (330) = 445,94 S.F. 24.09 c1 38 „ SIDE WALL HEIGHT 11.2 DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE. .74MEDIUM OVERALL HEIGHT 16" DISTRIBUTION BOX: 3 OUTLETS (MINIMUM) SAND 2.5Y 7/4 OVERALL WIDTH 34" Ems* 4640 TRUEMAN BLVD PRIMARY S.A.S. PERC 0 23.33 13.6 CF HILLIARD, OHIO 43026 USE 3 ROWS OF 5 - 16" ADS 16008D 810DIFFUSER H-20 UNITS CAPACITY (101.7 GAL) ADVANCED DRAINAGE SYSTEMS, INC. NO STONE AND EXTENDED 0.75' W/ CONTOURED WEDGES PROPOSED SEPTIC SYSTEM SITE PLAN BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.70 SF/LF OF BIODUFUSER) 28 FLICKER LANE ' WEST YARMOUTH MA ' (BIODIFFUSERS) 15 UNITS x 6.25 LF x 4.70 SF/LF = 440.63 SF 17.25 120" (CONTOURED WEDGE) 3 ROWS, x 0.75' x 4.70 SF/LF = 10.58 SF PERC RATE <2 MIN/IN. ("C" HORIZON) Prepared for: P Blue Water Septic P TOTAL AREA = 451.21 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(451.21 SF) = 333.89 GPD > 330 GPD req'd NO GROUNDWATER OBSERVED Engineering by: SCALE DRAWN DARREN M. MEYER, R.S. NTS D.M.M. • I, Darren M. Meyer, R.S., CSE, hereby certify that.) am currently approved by MADEP pursuant to 310 CMR 15.017 p080X981 DATE: to conduct soil evaluations and that the above analysis has been performed b me consistent with the EAST SANDWICH, MA 02537 CHECKED SHEET N0. requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Evol. Exam in October, 1999. 508-362.2922 11/05/09 D.M.M. 2 of 2