Loading...
HomeMy WebLinkAboutEngineered Plan - 2019N O� KEY: 4 �O EXISTING CONTOUR: — — — — ��Q� PROPOSED CONTOUR: ------------• p LOCUS EXISTING SPOT ELEVATION: 25.5 O PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: * UTILITY POLE: �— FENCE LINE: �O 0\r1G� HYDRANT: .-6- S� RETAINING WALL: LOCATION MAP LOT 17 (9,149 SF) ASSESSORS MAP: 58 PARCEL: 377 LAND COURT CASE 305618 BENCHMARK AT--\ PAINT MARK ON DECK SONO -TUBE ELEVATION = 103.01 101 1 12" oak rI 24" oak '` 25.0' 60 CV LEACH AREA DETAIL 102 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 2 BEDROOMS AT 110 GAL / DAY = 220 GAL / DAY SEPTIC TANK: 220 GAL / DAY x 2 DAYS = 440 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: (3 BEDROOM DESIGN, MINIMUM) USE 2 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) SIDE AREA: (25' + 12.8') x 2 x 2 = 151 SF (0.74) = 112 GAUDAY BOTTOM AREA: 25'x 12.8'= 320 SF (0.74) = 237 GAUDAY CAPACITY= 349 GAUDAY o O0 o� 0 G� s �o tioQ aG6 o�'m W \ 101 / r \ 36 twin oak \\ i �0, \ CP >\ ' 12" oak 5 �o i d 12" oak r �\ o \or,o° fire pit 7'e\\ 2 - 8" oaks \ Shed \ \ \ 103 M19-44 x.104 5 .,\14 G % 5y6o I ' 104 . Permit valid for REPAIR OF SEPTIC SYSTEM ONLY, due to State and Local septic variances. Foard or Health review and approval is required for any future ad4Ntiors/renovations/alterations to sewage facilities and/or structures/dwelling. Yarmouth Health Department APPR VED tf /a 6 °k Name Drte SEPTIC SYSTEM SECTION LOOR COVERS WITHIN 6" 104.40 XN OF FINISHED GRADE TOP OF d FOUNDATION ,,,, „ / 1/4" per ft 101.42 ELEV. a d 100.25 ELEV. 1500 GAL SEPTIC TANK (6" OF STONE UNDER OR MECHANICALLY COMPACTED) TEE SIZES: TO BE CONFIRMED) INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN GARAGE LIVING BED ROOM ROOM —r— DINING AREA BATH ROOM KITCHEN sh FAMILY ROOM DECK EXISTING FLOOR PLAN ERR`( 0 ANN WARNER � N No. 33721 F;. T MAX. COVER (V MIN) 1/4" per ft D -BOX " 6" OF STONE UNDER OR MECHANICALLY COMPACTED) ELEV. -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: PHIL RENAUD DATE: 9-25-19 PERCOLATION RATE: < 2 MIN/IN 2" PEASTONE OR FILTER FABRIC j — 3/4" - 1 1/2" DOUBLE WASHED STONE INSPECTION PORT ELEV.= 100.0 I,ril1° °°^°°°°^°^°I'IJ 97.17 4 4 ELEV. E 25'x 12.8' 2 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) 144"1 1 91.0 NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7, THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12, THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING CESS POOLS ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. MAS J. SITE PLAN LOCATION: 7 MIRROR BROOK RD., W. YARMOUTH, MA PREPARED FOR: SARA BLAKE XE: 9-26-19 SCALE: 1" = 20' BASS RIVER ENGINEERING I, E P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048 TH-1 103.0 O/A HORIZON ELEV. LOAMY SAND 11" 10YR 3/3 102.1 B HORIZON LOAMY SAND 30" 10YR 5/8 100.5 C HORIZON MEDIUM SAND 2.5Y 7/4 PERC AT 54" 144"1 1 91.0 NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7, THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12, THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING CESS POOLS ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. MAS J. SITE PLAN LOCATION: 7 MIRROR BROOK RD., W. YARMOUTH, MA PREPARED FOR: SARA BLAKE XE: 9-26-19 SCALE: 1" = 20' BASS RIVER ENGINEERING I, E P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048