Loading...
HomeMy WebLinkAboutReview Checklist rl9 TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. ri..--• Lot 'il Zone of Contribution: In Out_Acreage '57 /f "' • Commercial: Residential: �-- Street: �/ C / Village: (/j, 1` Floor Plan: ✓ #Bedrooms: 7------ Owner: Installer Arlerjr gJ £p Address: Phone: Phone: Builder: Engineer: ./V7-''''. ' Cf-.,(..SAddress: Phone: �---M2- Z Phone: N/A YES NO _ 1.Required#of copies received Ci.' 2.Date of soils exam and percolation test not older than 2 years (....---- 3.4-5 .f3.4-5 ft of naturally occurringpervious materia)z above water table �,,-, 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: k -- 5.Water line 10 ft from septic components Var.: L.----- 6.Benchmark indicated and shown-NGVD if near wetlands t�----- 7.Septic tank minimum 10 ft from foundation,deck Var.: L.----- 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: t/ 9.Leaching minimum 100 ft from wetlands Var.: ...----,- 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: `/ 11.Tank/leaching minimum 10 ft from property line Var.: c.--..- 12.System meets all other setback requirements Var.: �----- 13.Uses adjustment for maximum high groundwater Var.: 1/4.-......- 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: _ k._..---: 15.System not in top or subsoil(A,B horizons)or 5'removal `---.- 16.Proposed contours are suitable ._-. _ 17.System meets slope requirements-min. 1/8", %4"preferred C 18. System meets breakout requirements PVC liner: Wall: l._1 19.Specified tee sizes are proper,gas baffle on outlet tee �-----. 20.Sewage is under 10,000 gpd for parcel l, 21.No garbage disposal (.i- 22.System adequately sized for its intended use L� . 23.Minimum 6"stone or compacted below tank and dbox L1 24.Manhole covers within 6"of grade,pump chamber cover to grade `f 25.Inspection port on plastic chambers/leach field L.---,,. 26.Electrical permit for pump chamber/Separate meter for duplexes _ t..._..----' 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28.Septic tank/pump chamber to be factory waterproofed `/ 29.Vent provided if leaching below 3 feet,under driveway/parking t.�-."" 30.Buoyancy calculations for tank/pump chamber �`, 31.Engineer to inspect and certify soils: wall: commercial: c......------ 32. 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature %.„/ 33.H-20 loading is subject to vehicular traffic,groundwater ✓' 34.Title V Application and permit fee,installer signature - 35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max.flow: gpd 'r 37.Check area lots for groundwater/Label groundwater in Assessor's Map ..-"--_ Plan reviewed by: Utl6ro30