HomeMy WebLinkAboutEngineered Plan - 2009LEGEND 99 — EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR (98.4] PROPOSED SPOT EL. TH1 DATE: AUGUST 14, 2009 TEST HOLE 2� SLOPE OF GROUND (;ocheset UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW - - SEPTIC TANK: 330 GPD (2) 660 RE—USE EXIST..1000 GAL. SEPTIC TANK** LEACHING: SIDES: 2[2 (32 + 3) 2 (.74)] = 207 GPD BOTTOM 2[32 x 3 (.74)] = 142 GPD TOTAL: 471 S. F. 349 GPD *THE INSTALLER SHALL VERIFY THE USE (2) 32 LONG x 3' WIDE x 2DEEP LEACH TRENCHES LOCATIONS OF ALL UTILITIES AND ALL WITH 4" PERF. PVC PIPE AND DOUBLE WASHED ! STONE BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM APPROVED "INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE—USE. REPLACE WITH 1500 GALLON H-10 SEPTIC TANK IF NOT SUITABLE. 09-187 MA DATE BOARD OF HEALTH I I 4"S CH4 0 PVC C I SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE MINIMUM .75' OF COVER OVFR PRFrA(ZT ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORT TO WITHIN 3" OF FINAL GRADE 2% SLOPE REQUIRE OVER SYSTEM PRECAST H-10 RISERS (TYP.) 4"OSCH40 2'4 .41.5' _ PVC 3' MAX' N PIPES LE2 'EL 1ST ' 2 DOUBLE- WAH ED PEASTO E 0.75' MIN I _ OR GEOTEXTILE �ABRIC 10" EXISTING 14" 1000 GAL H-10 TEE TEE �jc 7.0-0o'0000000000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 40.1 f0° 0 0 0 0 0 0 0 0 0 0° 0 0 0 0 0 0 0 0 0 0 0 0 0 0 SEPTIC TANK uu0o°o°o°o°o°o°o°o°o°o°o°o°o°o°o°o°o°o°o°o° o°o°o°o°o°o°o 0 0 00000 0 38.45 000000000000000000000000000(RE—USE) o 0 0 0 0 0 o c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 •s 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0000000 0 00000000000000000000 00000036.3' GAS BAFFLE ., 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 00 000000000°0 °° °0°0°0°0°0°0°0°0°0°0°0°0°0°0°0°0°0°0°00 000°00000000000 10 38.65' 38.48' 4" PVC SET AT .005'/' SLOPE ON 6" DOUBLE WASHED 3/4" — 1 1 /2" STONE (2) 32' x 3' W. x 2' DEEP TRENCHES 59 6" CRUSHED STONE OR MECHANICAL WATER—TEST D'BOX FOR LEVELNESS COMPACTION. (15.221 [2]) (22% % SLOPE) (—!—% SLOPE) FOUNDATION EXIST. SEPTIC TANK 54' D' BOX 5' — i 1 q.ri nn' LEACHING FACILITY BOTTOM TH ELEV. 31.3'= NOTES 1. DATUM IS APPROX. NGVD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H—LQ 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE V.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. i LOCUS MAP NOT TO SCALE ASSESSORS MAP 64 PARCEL 27 LOCUS IS WITHIN APD NO CONSTRUCTION PROPOSED TEST D z ENGINEER: ARNE H. OJALA, PE, SE y. a WITNESS: c �pO�O'�O``Pii DATE: AUGUST 14, 2009 PERC. RATE Locus (;ocheset SOILS V' o Basset p» � Pon 41.3' 0 m 0/A LOCUS MAP NOT TO SCALE ASSESSORS MAP 64 PARCEL 27 LOCUS IS WITHIN APD NO CONSTRUCTION PROPOSED DATE 2.5Y 6/4 120" 31.3' NO GROUNDWATER ENCOUNTERED�� rl 12 COCHESET PATH WEST YARMOUTH PREPARED FOR B&B EXCAVATION/TURCO AUGUST 14, 2009 Scale:1 "= 20' ; (K9, i 0 10 20 30 40 50 FEET UGi 7 ��� off 508-362-4541 fax 508-362-9880 downcape.com down cape engiaeefiag, iac. civil engineers land surveyors >� 939 Main Street (Rte 6A) YARMOUTHPORT MA 02675 09-187.DWG(SBO) ' TEST HOLE LOGS ENGINEER: ARNE H. OJALA, PE, SE WITNESS: AMY *A./ f�tllUsc DATE: AUGUST 14, 2009 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS V' ELEV. p» 41.3' 0/A LS . _ 10YR 4/1 377 E FS 5'1 2.5Y 6/2 B LS 1OYR 5/6 36" C PER k r ti y$� rwr'a Lepar'(= t vizo MIS DATE 2.5Y 6/4 120" 31.3' NO GROUNDWATER ENCOUNTERED�� rl 12 COCHESET PATH WEST YARMOUTH PREPARED FOR B&B EXCAVATION/TURCO AUGUST 14, 2009 Scale:1 "= 20' ; (K9, i 0 10 20 30 40 50 FEET UGi 7 ��� off 508-362-4541 fax 508-362-9880 downcape.com down cape engiaeefiag, iac. civil engineers land surveyors >� 939 Main Street (Rte 6A) YARMOUTHPORT MA 02675 09-187.DWG(SBO) '