Loading...
HomeMy WebLinkAboutResent taA !q- 000St4 2015 IECC R-406 RESNET IIESNET RESIDENTIAL ENERGY SERVICES NETVvORK Registered Energy Rating Index Report Property Organ'Report Energy Rating Index Information Builder:Toni Smith Company:Home Energy Raters LLC RESNET Registered Rating Address: Phone:508-833-3100 Rating No:733036350 75 Sisters Circle, Yarmouth Port,MA Rater:Andrew Popielarski Rater ID(RTIN):5363711 02675 Date Rated:2019-09-03 HERS Index Estimated Annual Energy Consumption* mom Energy Rated Home Calculated Rated Home Cost($/yr) Energy Use(MBtu) 150 Existing 140 Heating 34.5 $587 Homes 13o Cooling 0.3 $20 120 Water Heating 11.1 $183 110 Reference Lights &Appliances 16.7 $901 Home "`•i yo Photovoltaics 0.0 $0 eitaw 'Based on standard operating candhons 60 so '1 ERI with PV:55 This Home ERI without PV:55 30 20 Annual Estimates Zero Energy 10 Electric(kWh):4,237.1 CO2 Emissions(Tons):5.5 Home 0 Natural Gas(Therms):481.1 Energy Savings($)**:N/A 1414 Emir/ 01013 RESM Y 'Based on the 2015 IECC R406 ReleRroe design rome Maximum Energy Rating Index:55 This Home's Energy Rating Index:55 PASS This home MEETS the Energy Rating Index Score requirement of 2015 IECC R-406 for Climate Zone 5. It MEETS all of the requirements verified by Ekotrope. Mandatory requirements are summarized on the 2nd page of this report, some of which are not verified by Ekotrope. Name: Andrew Popielarski Signature: Pepiela t4/n Organization: Home Energy Raters LLC Digitally signed: 9/4/19 at 9:30 AM Rati • Provider Data and Seal 4 h�r Company:Energy Raters of Massachusetts ' ,• Address:2 Woodlawn Street Amesbury,MA 01913 Phone#:978-270-3911 \ ""'°"'16 4 Fax#: .4° C'ttarywtfO To determine if a provider is properly accredited go to:www.rennet.us/professionaUprograms/search_directory Home Energy Rating Certificate Rating Date: 2019-09-03 Final Report Registry ID: 733036350 p Ekotrope ID: YdxJXPZ2 HERS® Index Score: Annual Savings Home: Your home's HERS score is a relative 75 Sisters Circle performance score. The lower the number, $ 1 55 783 Yarmouth Port, MA 02675 the more energy efficient the home.To Builder: learn more, visit www.hersindex.com *Relative to an average U.S.home Toni Smith Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtu] Annual Cost criteria of the following: Heating 34.5 $587 2015 International Energy Conservation Code Cooling 0.3 $20 ;,; Hot Water 11.1 $183 Lights/Appliances 16.7 $901 Service Charges $0 Generation (e.g.Solar) 0.0 $0 • Total: 62.6 S1,691 HERS Index Home Feature Summary: Rating Completed by: • 41111•4 Ner•w•a Home Type: Single family detached Energy Rater.AndrewPopielarski sso Model: N/A RESNET I D:5363711 Existing 103 Community: N/A s iso Conditioned Floor Area: 1,641 ft� Rating Gompany:l ome Energy Raters LLC 1120 „ Number of Bedrooms: 3 180 State Rd,Suite 2U Sagamore Beach MA 02562 Reference 508-833-3100 Home ion Primary Heating System: Fu rnace•Natural Gas•95 AFUE 90 Primary Cooling System: Air Conditioner•Electric•13 SEER Rating Provider:Energy Raters of Massachusetts or . ` '`°R w PrimaryWater Heating Water Heater•Natural Gas•0.93 EnergyFactor 2 Wood lawn Street Amesbury,MA 01913 ;,- , ° ,o 9 I 1 bo House Tightness: 624 CFM50(2.51 ACH50) 978-2703911 v ypa 'o Ventilation: 74.0 CFM•13.2 Watts "'".•"°" ao This Home Duct Leakage to Outside: 55 CFM25(3.35/100 s.f.) 30 so Above Grade Walls: R-21 4/2/A so Ceiling: Attic,R-37 ,?(,1a e,GUL POWLA& Zero Energy 0 Home Window Type: U-Value:0.3,SHGC:0.3 Andrew Popielarski,Certified energy Rater e„1/,1„e, `""""" Foundation Walls: WA Digitally signed 9/4/19at9:3(1AM ., eicot ope, Ekotrope RATER-Version:3.1.0.2244 The Energy Rating Disclosure for this home is available from the Approved Rating Provider. This report does not constitute any warranty or guarantee. Building Specification Summary Property Organization Inspection Status 75 Sisters Cirde Home Energy Raters LLC 2019-09-03 Yarmouth Port, MA 02675 508-833-3100 Rater ID(RTIN): 5363711 Andrew Popielarski RESNET Registered Sisters Cirde 75-final (Confirmed) Sisters Cir 75- YdxJXPZ2 Builder Toni Smith Building Information Rating Conditioned Area(ft2] 1,641.00 HERS Index 55 Conditioned Volume[ft3j 14,931.00 HERS Index w/o PV 55 Thermal Boundary Area[ft2] 5,210.00 Number Of Bedrooms 3 Housing Type Single family detached Building Shell Ceiling w/Attic I R37,DPCE,10",10x16,G1 U-0.03 Windows(largest)I U-Value:0.3, SHGC:0.3 Vaulted Ceiling I None Window/Wall Ratio 10.12 Above Grade Walls I R21,FG,6x16,G1 U-0.05 Infiltration(624 CFM50(2.51 ACH50) Found.Walls 1 None Duct Lkg to Outside 155 CFM25(3.35/100 s.f.) Framed Floors I R30,FG,12x16,G1 R-30 Total Duct Leakage 155 CFM25(Rough-In,with Air Handler) Slabs I None Mechanical Systems Heating Furnace •Natural Gas •95 AFUE Cooing Air Conditioner•Electric • 13 SEER Water Heating Water Heater• Natural Gas•0.93 Energy Factor Programmable Thermostat Yes Ventilation System 74.0 CFM • 13.2 Watts Lights and Appliances Percent Interior LED 100% Clothes Dryer Fuel Bectric Percent Exterior LED 100% Clothes Dryer CEF 4.3 Refrigerator(kWh/yr) 633.0 Clothes Washer LER (kWh/yr) 82.0 Dishwasher Efficiency 269 kWh Clothes Washer Capacity 3.2 Ceiling Fan(CFM/Watt) 70.4 Range/Oven Fuel Natural Gas Ekotrope RATER-Version 3.1.02244 N results are based on data entered by Ekotrope users.Ekotrope disclaims all fabiiy for the information shown on this report. Air Leakage Report Property Organization Inspection Status 75 Sisters Cirde Home Energy Raters LLC 2019-09-03 Yarmouth Port, MA 02675 508-833-3100 Rater ID(RTIN): 5363711 Andrew Popielarski RESNET Registered Sisters Cirde 75-final (Confirmed) Sisters Cir 75- YdxJXPZ2 Builder Toni Smith General Information Conditioned Floor Area[sq.ft.] 1,641 Infiltration Volume[cu.ft.] 14,931 Number of Bedrooms 3 Air Leakage Measured Infiltration 624 CFM50(2.51 ACH50) ACH50(Calculated) 2.51 ELA[sq. in.] (Calculated) 34.32 ELA per 100 s.f. Shell Area(Calculated) 0.659 CFM50(Calculated) 624 CFM50/s.f. Shell Area(Calculated) 0.120 Duct Leakage System 1 Leakage to Outdoors 55 CFM25 (3.35/100 s.f.) Total Leakage Test Type Rough-In, with Air Handler Total Leakage[CFM 0 25 Pa] 55.0 Total Leakage [CFM25/100 s.f.] 3.4 Total Leakage[CFM25/CFA] 0.034 Mechanical Ventilation Rate[CFM] 74.0 Hours per day 19.4 Fan Watts 13.2 Recovery Efficiency% 0.0 Runs at least once every 3 hrs? true Average Rate[CFM] 59.8 2010 ASHRAE 62.2 Req.Cont.Ventilation 46.4 2013 ASHRAE 62.2 Req.Cont.Ventilation 59.7 Ekotrope RATER-Version 3.1.02244 Al results are based on data entered by Ekotrope users.Ekotrope disclaims al lability for the information shown on this report. RESNET HOME ENERGY RATING Standard Disclosure For home(s) located at: 75 Sisters Circle, Yarmouth Port, MA Check the applicable disclosure(s) in accordance with the instructions on the reverse of this page: 011. The Rater or the Rater's employer is receiving a fee for providing the rating on this home. 02. In addition to the rating, the Rater or the Rater's employer has also provided the following consulting services for this home: —A. Mechanical system design D B. Moisture control or indoor air quality consulting C. Performance testing and/or commissioning other than required for the rating itself O D. Training for sales or construction personnel E. Other(specify) 3. The Rater or the Rater's employer is: LJA. The seller of this home or their agent f[B. The mortgagor for some portion of the financed payments on this home VC. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home j4. The Rater or Rater's employer is a supplier or installer of products, which may include: Products Installed in this home by OR is in the business of HVAC systems IIRater [ [Employer LIRater [—Employer Thermal insulation systems jRater . Employer Rater Employer Air sealing of envelope or duct systems FiRater Employer FiRater fEmpbyer Energy efficient appliances [Rater 'Employer [Rater liEmpbyer Construction (builder, developer,construction contractor, etc) ERater I [Employer [Rater Employer Other(specify); r Rater j [Employer Rater l[Employer Wit5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET). Rater Certification#: 5363711 To report any complaints regarding this Rater's service, please visit: http://www.energyratersma.com/Feedback_New.html Name: Andrew Popielarski Signature: /i(r,, uat Pepielandd Organization: Home Energy Raters LLC Digitally signed: 9/4/19 at 9:30 AM I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality control provisions of the rating standard are contained inChapter One 4.C.8. of the standard and are posted at http://resnet.us/standards/RESNET_Mortgage_Industry_National_H ERS_Standards.pdf The Home Energy Rating Standard Disclosure for this home is available from the rating provider. RESNET Form 03001-2 -Amended April 24, 2007 Mass Save RNC PFS Savings Report Property Organization Inspection Status 75 Sisters Circle Home Energy Raters LLC 2019-09-03 Yarmouth Port,MA 02675 508-833-3100 Rater ID(RTIN):5363711 Andrew Popielarski RESNET Registered Sisters Orde 75-final (Confirmed) Sisters Or 75-YdXJXPZ2 Builder Toni Smith Annual End-Use Consumption Reference Home Rated Home Savings % Saved Heating[Natural Gas Therms] 560.6 458.9 101.7 18.1% Heating[Electric kWh] 170.3 141.2 29.1 17.1% Cooling[Electric kWh] 194.0 200.9 -6.8 -3.5% Hot Water[Natural Gas Therms] 138.4 110.7 27.7 20% Lights&Appliances[Natural Gas Therms] 29.2 29.2 0.0 0% Lights&Appliances[Electric kWh] 4,041.3 4,041.3 0.0 0% Total[Natural Gas Therms] 728.2 598.8 129.4 17.8% Total[Electric kWh] 4,405.6 4,383.3 22.3 0.5% Electric Savings Incentive $7.79 Fuel Savings incentive $452.94 Percent Savings Incentive $444.58 Rater Incentive' $350.00 Participant Incentive $905.30 Percent Savings 14.82% 'Rater Incentive is distributed directly to Rater by Mass Save Program. Ekotrope RATER-Version 3.1.02244 AM results are based on data entered by Ekotrope users.Ekotrope dsclaims all lability for the information shown on this report. IECC 2015 Label 75 Sisters Circle Ekotrope RATER -Version:3.1.0.2244 HERS® Index Score: 55 Ceiling: R-37 Above Grade Walls: R-21 Foundation Walls: N/A Exposed Floor: R-30 Slab: null Infiltration: 624 CFM50(2.51 ACH50) Duct Insulation: R-6 Duct Lk• to Outdoors: 55 CFM25 3.3.5/100 s.f. . U-Value: 0.3, SHGC: 0.3 Door: R-7 Heating: Furnace • Natural Gas• 95 AFUE Cooling:Air Conditioner • Electric • 13 SEER Hot Water:Water Heater• Natural Gas •0.93 Ener.) Factor (Confirmed and tested) Climate Zone 5 Mandatory Requirements Provision Number Topic Compliance Decision 2009 IECC Table Building thermal envelope minimum insulation levels and PASS 402.1.1 or 402.1.3 maximum fenestration U-factor and SHGC R401.3 Post a permanent certificate listing the level of efficiencies Certificate required for CO installed in the house R402.4.1.2 Envelope ak leakage maximum leakage rate PASS R402.4.1 /Table Comply with air sealing and insulation requirements in Table Checklist required for CO R402.4.1.1 R402.4.1.1 R402.4.4 Rooms containing fuel-burning appliances PASS* R402.5 Maximum fenestration U-factor and SHGC (U-Factor) PASS (SHGC) PASS R403.1.2 Heat pump controls PASS* R406.2 Ducts outside of conditioned space to be insulated to a PASS* minimum of R-6. R403.3.2 Duct seeing on all ducts PASS* R403.3.3 Duct testing for ducts in unconditioned space PASS* R403.3.5 Building cavities not used as ducts. PASS* R403.5.1 Heated water circulation and temperature maintenance PASS* systems comply R403.5.3 Hot water pipe insulated to R-3 FAIL R403.6 Mechanical ventilation meeting the requirements of the IRC PASS* or IMC. Outdoor air and exhaust dampers installed R403.7 ACCA Manual J and S conducted for all heating and cooling ACCA forms required for systems. permit R403.8 Systems serving multiple dwelling units to meet the PASS* mechanical requirements of IECC commercial code R403.9 Snow melt and ice system controls installed where applicable PASS* R403.10 Pools and permanent spa energy consumption meet PASS* requirements for heaters,time docks and covers R403.11 Portable spas meet the requirements of APSP-14. PASS* R404.1 High efficacy lights installed in 75%of permanently instated PASS fixtures. These items have been field-verified by the Rater,Field Inspector, Code Inspector,or Builder.