HomeMy WebLinkAboutEngineered Plans - 2019-- 94-- --- EXISTING CONTOUR
BH
x 90.98 EXISTING SPOT GRADE
m
yy- EXISTING WATER SVC. •�
BATH
BED RM.BED RM --- EXISTING GAS SERVICE
KITCHEN 98 Wandward Way
OVERHEAD WIRES ck�el„y Wey'
IS TEST PIT /
BED RM. UVI. ROOM �• BENCHMARK s "
LEGEND
FLOOR PLAN s `
a CL�V� LOCUS
SMTP
N
`� N
d 99.41
-D Ty�q
99.58
y
edge ofPov 99.45
0
98.78 x 99.
p0 '2$'40" 99.06
0 0.27. E x 99.80
0
x 99.72 BENCHMARK
B7
25, ZD ORANGE DOT/BH
EL. -99.29
>- _ N(`:•. 0 VENT
BSEAL o K 2
98.
m 99
98.19 . x
.16
LOT 45 m STP 9e)
17,415. ±SF x 98.84 -1
N
98.8
PROPOSED SEPTIC TANK
,
x'.....
9 98.94
9757 EXISTING CESSPOOL
0
- (FROM RECORD AS -BUILT)
T
,e ' BH U Id 0 o TO BE PUMPED, FILLED
o- WITH SAND & ABANDONED
9914,98.9
xo
x`
.....96)R1NSE98
o 82 z
98 +; N o G�� pmC 98 64 . � � 9 5 EXIS77NG LEACH PIT
78
(FROM RECORD AS -BUILT)
TO BE PUMPED, FILLED
ti 97,27 9817
PATIO WITH SAND & ABANDONED
+ 98.18
96.58 DECK
... 98.58 97.64
.,,..,..
tNr" a - x x 96.84
�., "sr� N
0 H 518.51
Nrn
97__
t� P. x 96.56
96 6 x 6.33 + 96.85 51,1 01.
J.� 96.56 i �' N �'
F--1 95.38 96:03 "' � O � ca
\J
DRIVEWAY 0
0-
96.0 96.28
t� x t 96
x
95.67 v, 96.01
x
✓
9448 95.54�
m
m
�1PvSt{ OF /,igSS� 4
, 42 LOT 45 6
Qm Permit valid fur REPA ¢d' S ; TIC SYSTEM
02
JOHN L. 17,415±S.F. ONLY, dna to State atie variances.
"s
CHURCHILL JR. ur 94.17 Board of Health r grllraeal required for
v NO.48066 0: any at ditiosts9reno8 aflions/a erations 10
Ao,t >� x 95.43 a facdfities andlor structuresldweR g.
Fsy GIST x 94.55 151
hA p W YBrtnflf nadtta { ;1rleraeaat
c�dz� x 9A.90 �0��1'6 p0"
S 3 APPROVED
CB
94.51
UE MgSs�C�o 93.69Datea
� e
��Pl��
MAP 1
PETER r. r
MCEN EEE
V
CIVILPROPOSED SEPTIC SYSTEM UPGRADE PLAN
No.5109
98 WENDWARD WAY, WEST YARMOUTH, MA
0
S Prepared for: Kenneth Doherty, 40 Clements Road, Waltham, MA 02453
OWNER OF RECORD
DOHERTY, KENNETH M Engineering by: Survey Re rew by: SCALE DRAWN JOB. NO.
"=20'
t DOHERTY, ROBIN G Engineering Works, Inc. JCEngineering, Inc. 1 P.T.M. 262-19
40 CLEMENTS RD 12 West Crossfield Road 2854 Cranberry Hwy. DATE CHECKED SHEET NO.
i Forestdole, MA 02644 E.Wareham, MA 02538
WALTHAM, MA 02453
(508) 477-5313 (508) 273-0377 10�8�19 P.T.M. 1 Of 2
NOTE: TO PREVENT BREAKOUT, FINAL GRADE
SHALL NOT BE AT, OR BELOW, EL=94.70
FOR A DISTANCE OF 15' FROM THE EDGE
SEPTIC TANK PROPOSED D -BOX OF THE PROPOSED S.A.S.
INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER PROPOSED SAS.
OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE
INSTALL RISER & COVER OVER EACH CHAMBER AND
T.O.F.-99.26+ SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT
F.G. EL.=98.9± F.G. EL=98.8± F.G. EL=99.0± F.G. EL. -99.5± VENTMAINTAIN2% SLOP OVER SAS.
L = 17' L = 26'
L - 22,
O S -1X (MIN.) O S�iX (MIN.) O Sm1X (MIN.)
4"SCH40 PVC 4"SCH40 PVC 4"SCH40 PVC 2� LAYER OF 1/8" TO 1/2"
DOUBLE WASHED STONE
10'1 ®®�®®® (OR APPROVED RLTER FABRIC)
tb 2' EFF. aaaaaaa
48' LIQUID DEPTH y6 ��"��'N„ am 0000 -3/4' TO 1-1/2- DOUBLE
TINV.�=95.1
LEVEL ADD INV. -94.57 PROPOSED INV -9440 4 4.e' 4' WASHED STONE
. .
GAS BAFFLE BOX EFFECTIVE WIDTH 12.8'
....... .... INV.=94.85
3 OUTLETS
INV.=94.20
PROPOSED SEPTIC TANK 2-500 GALLON LEACHING CHAMBERS
SURROUNDED WITH STONE AS SHOWN
CONNECT TO EXISTING SUITABLE SEWER PIPE/S H-20 RATED
AT HOUSE, AT OR ABOVE, INV.=95.42±(ver
TOP CONC. ELEV.=95.3±
BREAKOUT ELEV.-94.70 p
INV. ELEV.=94.20 a----
NOTES: aaaaaaaaaaa
aaaaaaaaaaa
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE BOTTOM ELEV.=92.20
INVERTS, PRIOR TO INSTALLATION. 4' 2 x 8.5' - 17.0' 4'
2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND 4' OF NATURALLY OCCURRING EFFECTIVE LENGTH - 25.0'
TRUE TO GRADE ON A MECHANICALLY COMPACTED PERVIOUS MATERIAL
STABLE BASE OR OR SIX INCH AGGREGATE BASE, AS 5' (MIN.) ABOVE G.W.
SYSTEM SECTION
LEACHING
SPECIFIED IN 310 CMR 15.221(2). BOTTOM OF TEST PIT, EL=87.2
r
3) INSTALL INLET & OUTLET TEES AS REQUIRED.
4) A GAS BAFFLE SHALL BE INSTALLED ON OUTLET TEE
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL.
SEPTIC SYSTEM PROFILE
SOIL LOG
GENERAL NOTES:
DATE: OCTOBER 2, 2019
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
SOIL EVALUATOR: PETER McENTEE PE(SE#1542)
BOARD OF HEALTH AND THE DESIGN ENGINEER.
WITNESS: PHIL RENAUD HEALTH AGENT
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE
ELEv.TP-1 DEPTH ELEv. TP -2 DEPTH
LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW:
0 0"
-310 CMR 15.405(1)(b):
98.7 A 99.1 A
1) A 1.5 variance to the 3' maximum cover requirement, for up to
LOAMY SAND LOAMY SAND
10YR 4/2 10YR 4/2
4.5 of max. cover. S.A.S. shall be H-20 and vented.
98.2 98.7
6"B 5"
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
B
LOAMY SAND LOAMY SANG
LOAM5
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
/ 4 10YR 5/4
DESIGN ENGINEER.
96.7 24" 96.9 26"
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
C1C1
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
PERC
M -C SAND M -C SAND
5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM.
2.5Y 6/4 33/51" 2.5Y 6/4
5. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
5% GRAVEL 5% GRAVEL
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
92.7 72" 92.9 74"
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
C2 C2
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
MED. SAND MED. SAND
8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S.
2.5Y 6/6 2.5Y 6/6
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
138' 87.6 138'
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
87.2
DIRECTED BY THE APPROVING AUTHORITIES.
PERC RATE <2 MIN/IN. "C" HORIZONS
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
NO GROUNDWATER ENCOUNTERED
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL.
62,1'
13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND
NOT CONSIDERED TO BE A PROPERTY LINE SURVEY.
SEPTIC
�' oi' R 4
14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED
THE PLAN
QO
/
SYSTEM COMPONENTS NOT SHOWN ON
p Qcor
0' �i0 _ DECK
DESIGN CRITERIA
41,6' eH
7281 29.5 _
NUMBER OF BEDROOMS: 3
I
SOIL TEXTURAL CLASS: CLASS 1 (LOADING RATE=0.74 GPD/SF)
IEXISTING E
��6'
DESIGN PERCOLATION RATE: <2 MIN/IN
g9� HOUSE(,f98)
DAILY FLOW: 330 GPD
DESIGN FLOW: 330 GPD
GARBAGE GRINDER: NO -not allowed with design
LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF
.74 GPD/SF
SEPTIC LAYOUT
PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY
PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-10 RATED
9-500 LEACHING CHAMBERS IN SERIESPROPOSED
SEPTIC SYSTEM UPGRADE PLAN
98 WENDWARD WAY WEST YARMOUTH MA
USE GALLON
SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES
Prepared for: Kenneth Doherty, 40 Clements Road, Waltham, MA 02453
SIDEWALL AREA: 2(12.8" + 25.0') X 2 = 151.2 S.F.
En9inee^n9 by.
Survey Ravi " by:
SCALE
DRAWN
BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F.
Engineering Wor4 Inc.
JCEngineerfng Inc.
N.T.S.
P.T.M.
262-19
TOTAL AREA: .............................................................. 471.2 S.F.
12 west CrouMield Road
2834 Cronb" Hwy.CHECKED
Forestdole, MA 02644
E.Wareham, MA 02538
DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.7 GPD
(308) 477-5313
(508) 273-0377
10/8/19
P.T.M.
1 Of 2