Loading...
HomeMy WebLinkAboutBLDE-19-007105 Commonwealth of Official Use Only Permit No. BLDE-19-007105 f_ ` Massachusetts BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked (Rev_1/07J APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:6/18/2019 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to pertorm the electrical work described below. Location(Street&Number) 151 BEACON ST Owner or Tenant GRUDZINA ROBERT Telephone No. Owner's Address GRUDZINA ARLENE J, 151 BEACON ST,SOUTH YARMOUTH, MA 02664 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system.(18 Panels 5.67 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: BRIAN K MACPHERSON Licensee: Brian K Macpherson Signature LIC.NO.: 21233 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:32 GROVE ST,DBA TRINITY SOLAR,PLYMPTON MA 023671306 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 f&&,&tF 43 (i'ct �(236? £E C..nnttnanweaiTh n)frlamrrrku3at/h (71lieial Use Only 'ec i -.t ]� ^�j� Permit No. Eli- J �0S 1Jlpartnwst O�..TGre )arrozai ! Occupancy and Fee Checked BOARD OF FIRE PREVENTION REGULATIONS tttev. I%071 (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK AA work to be performed in accordance with the M asaelrwetts Electrical Code t,MEC), 577 CAR 12 Ott (PLEASE PRINT rMINK OR TYPE AU INFORMATION) Date: 6/13/19 City or Town of: Sat ith Yarmouth I o the Inspector u;?Wires. By this application the undersigned gives notice of his or her intention to perform the electrical work describes below Location(Street&Number) 151 Beacon St. Owner or Tenant Arlene Gruti7ina Telephone No. 914-804-0016 Owner's Address 151 Beacon St. Is this permit in conjunction with a building permit? Yes iir- No ❑ (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service 100 Amps 120/240 Volts Overhead❑ Undgrd❑ No.of Meters 1 New Service Amps 120/ 240 Volta Overhead❑ Undgrd❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Install 5.67 kw solar panels-on roof_ Will not exceed roof panel, but will add 6"to roof height. 18 total panels. Completion of the followinxiable Inv,be waived&the of WIri n. No.of Recessed Luminaires No.of Ceil:SuP•(Paddle)sFans No. s Total TrTransformers [CVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting Bgrad. grad. Battery nags No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS INo.of Zones No.of Switches No.of Gas Burners 1Yo of Detection sad t Iaftiatlue Devices No.of Ranges No.of Air Cond. Tons[ No.of Alerting Devices Heat Pump Number Tons KW -No.oT e[f-Coaiaised DisposersTotals: Deteedonn!Alertio Devi Na of Waste ces No.of Dishwashers Space/Area Heating KW Local❑ Pono la ❑ Other HeatingAppliances merit'Systems:* No.of Dryers PP KW No.of Derkes or Equivalent No.of Water No.of No.of Data Wiring: Heaters KW Signs Ballasts No.of Devices or Equivalent No.H drom,assa a Bathtubs No.of Motors Total HP 'TelecommunicationsNfDeior Wiring: vl 3' g No.of Devices igeivaleot OTHER: 18 total panels. ` 25,000 Attach additional detail ifdesired,or,rs required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to Start: TBD Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent The undersigned certifies that such coy age is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE INSURANCE Vi BOND ❑ OTHER ❑ (Specitl:) I certify,under the pains an penalties ofperjury,that the information on this application is Mar and conwiete FIRM NAME: -r,h; `! So v LIC.NO.: Licensee: / �.,.,� /'1'a.ep�{+Sc]h Signature J a...# d4-1 C+-.-t. [AC.NO.: 61Ic 3) 4 (If apprertble enter'exempt"in the{'cease p+mher inns? f Bus.Tel.No.: Address: 3n 6 ro.c 5 fl' trig out (4-- O4236 f Alt.TeL Si).:cdl' f77 319 I *Per M.G.L..c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lie,No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Own eens PERMIT FEE:$ Signature ___. .___..__. ____._ Telephone No. r INSTALLATION OF NEW BEACON STREET. ROOF MOUNTED PV SOLAR SYSTEM b` 151 BEACON STREET • SOUTH YARMOUTH, MA 02664 Issued I Revisions • • VICINITY MAP SITE NO DESCRIPTION DATE SCALE:NTS L. Project Title: GRUDZINA,ARLENE- TRINIT/ACCTI:2U19-05-342217 Project Address: 151 BEACON STREET SOUTH YARMOUTH,MA 02664 41.687270,-70.197435 GENERAL NOTES GENERAL NOTES CONTNNE= GENERAL NOTES CONTINUED MEBREWATLONS CONTINUED SHEET INDEX Drawing Title: I.THE INSTALLATION CONTRACTOR IS B. THE DC VOLTAGE FROM THE PANELS IS 14. N CURRENT PREVAILINGUTSLTV JB JUNCTpNBOA PV-1 COVER SHEET W/SITE INFO&NOTES RESPONSIBLE FOR INSTALLING ALL ALWAYS PRESENT AT THE DC COWAN Y SPECIFICATIONS. ACIAL THOUSAND CIRCULAR MIS EQUIPMENT AND FOLLOWNGALL DISCONNECT ENCLOSURE AND THE DC STANDARDS,AND REQUIREMENTS RCA KLOVOLT AMPERE PV-2 ROOF PLAN W/MODULE LOCATIONS PROPOSED PV SOLAR SYSTEM DIRECTIONS AND INSTRUCTIONS TERMINALS OF THE INVERTER DURING 15 THIS SET OF PLANS HAVE BEEN kW KILOWATT CONTAINED IN THE DRAWING PACKAGE ANC DAYLIGHT HOU RS.ALL PERSONS PREPARED FOR THE PURPOSE OF RATH KILOWATT HOUR PV-3 ELECTRICAL 3 LINE DIAGRAM INFORMATION RECEIVED FROM TRINTTY. WORMNO ON OR INVOLVED WITH THE MUMCPAL AND AGENCY REVIEW AND L LINE 2.THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM ARE WARNED APPROVAL.THIS SET OF PLANS SHALL MGR MAIN CIRCUIT BREAKER AP APPENDIX Drawing Information RESPONSIBLE FOR INSTALLING ALL TINT THE SOLAR MODULES ARE NOT BE UTB4'ED AS CONSTRUCTION MLW MAW LUGCIBIRION PANEL DRAWING DATE: E/3/2019 EQUIPMENT AND FOLLOWING,ALL ENERGIZEDUVHENEVER THEY ARE DRAWINGS UNTIL REVISED TO INOICATE MLO MA.N ONLY MID MOUNTED DRAWN BY. MS IS IRE IOrvSLEDINSTILIAL. CON TMNEO EXPOSED TOLIGHT. ALL INFORMATION ONSSHOAR!TE MTG MOUNTING IIfVKED BY. N E IN T LLATIO ACON TR. L. ALLCIPORTIONSVOLTI THIS SOLAR IS ALL EDPRIOR USE TENT BE N NEUTRAL 3.THE RESPONSIBLE FOR READING ANDS MARKED PHOTOVOLTAIC SYSTEM SHALL E CONSTRU PRIOR TO USE FOR NEC NATIONAL ELECTRICAL CODE RESPONSIBLE FOR READING AND MARKED CLEARLY W ACCORDANCE WITH CONSTRUCTION ACTIVITIES. NEC NOT N CONTRACT System Information: UNDERSTANDING ALL DRAWINGS,MA, THE NATIONAL ELECTRICAL CODE NOI NUMBER COMPONENT AND INVERTER MANUALS ARTICLE ISO&TON. PRIOR TO INSTALLATION.THE INSTALLATION TO. PRIOR TO THE INSTALLATION OF THIS ABBREVIATIONS NTS NOT TO SCALE DC SYSTEM SIZE, 5.67kW CONTRACTOR IS ALSO REQUIRED TO HAVE PHOTOVOLTAIC SYSTEM.THE OCP MBA CURRENT PROTECTION AC SYSTEM LIE: LW ALL COMPONENT SWITCHES IN THE OFF INSTALLATION CONTRACTOR SHALL AMP AMPERE P POLE TOTAL MOUE COUNT. POSITION ANO FUSES REMOVED PRIOR TO ATTEND A PRE-NBTALLTION MEETING C ALTERNATING CURRENT PS DULL BOX MODULES USED HANWHA 315 THE INSTALLATION OF ALL FUSE BEARING FOR THE REVIEW DE THE INSTALLATION AL AALMP. PVC. POLO- MODULE SPEC A: LI PEAK DUO BLK.GS 31S SYSTEM COMPONENTS PROCEDURES,SCHEDULES,SAFETY AND aF AMP.FRAM: PVC POLY-VNYL CHLORIDE CONDUIT N.ONCE THE PHOIOVOLTP.IO MODULES ARE COORDINATION. AFF ABOh FINI E FLOOR PAR POWER UTILITY COMPANY: EVERSDURCE MOUNTED.THE INSTALLATION IT PRIOR TO THE SYSTEM START UP THE AFL' ABOVE FINISHED GRADE TITTASS QUANTITY UIILRY ACCT I. DIN335 DOM CONTRACTOR SHOULD HAVE A MINIMUM OF INSTALLATION CONTRACTOR SHALL. C AMEPIOAN WIRE(AMIGO ROS GALVANIZED STEEL C CONDUIT I GENERIC TERM OF SN SOLID NEUTRAL UlIU1Y METER p: 23GSAi6 ONE ELECTRICIAN WHO HAS ATTENDED A ASSIST W PERFORMING ALL INITIAL RACEWAY PROVIDE AS ISWBD SWITCHBOARD 'DEAL TYPE SOLAR PHOTOVOLTAIC INSTALLATION HARDWARE CHECKS AND DC".VIRINO SPECIFIED) TYP TYPICAL COURSE ON SITE. CONDUCTIVITY CHECKS. CA COMBINER BOX U.O.I. UNLESS OTHERWISE INDICATED S.FOR SAFETY.IT IS RECOMMENDED THAT 12. FOR THE PROPER MAINTENANCE NC OAT CIRCUIT LW WEATHERPROOF • THE INSTALLATION CREW ALWAYS HAVE A ISOLATION OF THE INVERTERS REFER TO CT CURRENT TRANSFORMER OFMR TRANSFORMER Roy,No. Shoot MINIMUM OF TWO PERSONS WORKING THE ISOLATION PROCEDURES N THE CU COPPER .72 MOUNT 72 INCHES TO BOTTOM TOGETHER ONE THAT EACH OF THE OPERATION MANUAL DC DIRECT CURRENT OF ABOVEFINSHED FLOOR OR INSTALLATION CREW MEMBERS BE TRAINED AR, THE LOCATION OF PROPOSED ELECTRIC DISC DISCONNECT SWITCH GRADE E"�/B P\ / - Al IN FIRST AID AND CPR. TNDTELEPHONE AL OF THE ARE SUBJECT DIY, o wWIN, 1V 1 V I S.THIS SOLAR PHOTOVOLTAIC SYSTEM IS TO TO FINAL APPROVAL OF TFHE EC ELECTRICAL SYSTEM INSTALLER BE INSTALLED FOLLOWING THE APPROPRIATE UTILITY COMPANIES AND EMT ELECTRICAL METALLIC TUBING CONVENTIONS OF THE NATIONAL OWNERS. FS FUSIBLE SWITCH ELECTRICAL CODE.ANY LOCAL EOOF IS. ALL MATERIALS,ER WORKMANSHIP AND FU FUSE W HICN MAY SUPERSEDE THE NEC SHALLON FOR CONSTRUCTION THE OEINSATE GIRD GROUND GOVERN. IMPROVEMENTS SHOWN HEREIN SHALL CPI GROUND FAULT INTERRUPTER Anityle T.ALL SYSTEM COMPONENTS TO BE BE IN ACCORDANCE WITH: HZ FREQUENCY(CYCLES PER INSTALLED WITH THIS SYSTEM ARE TO BE AT CURRENT PREV.ALNG MUNICIPAL SECOND) 'EL'LISTED.ALL EQUIPMENT WILL BE NEAR ANCAOR COUNTY SPECIFICATIONS, SROUTDOOR RATED UNLESS INDOORS. STANDARDS AND REQUIREMENTS GENERA NOTES IF ISSUED DRAWING IS MARKED WITH A REVUE ION CHARACTER OTHER THAN'A",PLEASE BE ADVISED THAT FINAL EQUIPMENT AAWOP-SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AYABABUTY OF EQUIPMENT. 2211 ABenorood Road Wall,New Toni,07719 877.78E7283 l NAI S..REFER TO MODULE SPECS FOR MODULE DIMENSIONS 'fJEPIOTEO MODULES MAY BE PORTENT OF.LANDSCAPE UMRAC CLAMP I rvEWPv souR MODULE,nPIul (PIFER r,QbE(TEST FUR DEWLN (REFS OCR AlAENTSCHEOULE F IR SF£CS FNDOWNlIT1E8 � � �/ ! SOLAR MODULE SOLAR MODULE � F \11111 PAND DET.NLs) .6 INTER TNWetPESTPOEPOENq NEw ANRAC RaL nPIUL B nFUUUTED FE1v9nDCuuR TO nFEaT UNIRAC FLASHING—Ns - EXISTING ASPHALT SHINGLES ft:TUNE(REFER TO LAIPAC rt JEFi ERR NEON A 'xFFFaT ENYNEF P r EA FOR IRE PE ARf:anou,DATA SHEET FOR DE'rc) NEW ENO CUP TYPICAL S.S.LAG BOLT APOC SEALANT ,S :~\ (EFE TD UNR<.0 SPEtlFICA.TH)N, • • SOLAR MODULES SHALL NOT R iii � DATA SHEET FJR DETAILS) REFEATOE EXISTING RAFTER ten. EXCEED PEAT(HEIGHT. NEW MID CUP,ngCAL xrlxEEac LOUR rpt42c (REFER rO UNRAC SPECIFICA NON, SOP..SOT &CLIP DETAIL DATA SHEET FOR D TAXsl MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF T'lfEIGH7 FROM GROUND LEVEL TO PEALS OF ROOF SGA.NOT SCALE LE NOT TO SCALE SCALE.NOT TO SCALE -.-... ARRAY SCHEDULE Issued I Revisions FRONT h NO. DESCRIPTION DATE EP M{� Project Title: D p 6, UD GRUDZINA,ARLENE- ® TRINITI ACCT(:2019-05-342217 Tom—'---- � I Project Address:` I ` FRONT \ 151 BEACON STREET I ee\ SOUTH YARMOUTH,MA 02664 1 ® 3N -- I ' 41687270,-70.197435 i _ Rol AE It II- Drawing Title: II ® ' ■ Y I. 1 - PROPOSED Pi/SOLAR SYSTEM BACK \ ElOMI�fl 1 L _A . ., Drawing Inf.-elation L__ (PROPERTY LINE - .=Ii 11 DRAWING DATE: 6/3/i015 DAAWH BY. MS 1111 WKfD BY. MD ® - - —-- Systom SIZE: AC DC SYSTEM S11E: MS:w AC SYSTEM SAE'. SAW TOTAL MDDULL C WIT. LS MODULES USED. HANWHA 315 ROOF MODULES:D ITCH:30` MODULE SPECS OPEAN DUO&R-GS] ORENTAIIDN'351'. UTILITY COMPANY: EVERSOURCE BACK UTILITY ACCT F. .86 335 DON ROOF PITCHMODU1F5: NOT ES: 9 UTILITY METER A 7365416 :30 ORIENTATION:171 DEAL TYPE: 5A 1.1 ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE ROOF3 WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS MODULES.O 1.1 ARRA` VERIFICATION BONDING TO COMPLY WITH MANUFACTURER SPE N. ORIENTATION.351. 3.1 ALL LTCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFIFl CA4 TION Roy.NO. Shoot AC DISCONNECT SHALL BE GROUPED WITH INVERTER(5)NEC 690.13 I ED. ' ROOF 5L ALL OUTDOOR.EQUIPMENT SHALL BE INN TIGHT UL SwrrtiHALL W MINIMUM NEFM 3R RATING („ 0 6.1 ROOFTOP SOLAR INSTALLATION ONLY PVARRAY SHALLNOT EXTEND BEYOND T EXISTING ROOF EDGE P1 PV - ORIENTATION TION.171" ROOF SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE MODULES:9 CITY SPEC PITCH:30 INDICATES ROOF DESIGNATION.REFER TO INDICATES NEW UNFUSED PV DISCONNECT TO BE SP INDICATES NEW PY ONLY SUaPANEL ORIENTATION:1)3 OD SCHEDULE FOR MORE INFORMATION UL INSTALLED OUTSIDE(UTILITY ACCESSIBLE I TOSS INSTALLED 14 WANWHA 315 IIPEAA DUO IILXG53151 • ROOF 6 MODUES:D ARCM:30° INDICATESPANES THAT U MODULE.RONVE1500.MODULES ] SES(DDN-USODONN[2 DRIENTAiION'Si' M INDICATES EXISTING IAETER LOCATION REFER EQUIPMENT NT USE MICROFOR SPECS. ROOF T REFER TO EfXAPMENi SCHEDULE FOR SPECS. MoouLEs D - OTHER OBSTRUCTIONS ORIENTATION 81' INDICATES EXISTING ELECTRICAL PANEL INDICATES NEW PRODUCTION METER TO BE s __ E-. LOCATION.INSIDE INSTALLED INSTALLED OUTSIDE. SOLAR ROOF 8 �T1F MODULES D INDICATES A) Q INDICATEDINSIDEUSED PV DISCONNECT TO BE ED dITLD INVERTER TO BE • 11L1 Allenwood M'oad 07719 BT-)S6J1b3 ORIENTATION 1]Iie • w REFER TO EQUIPMENT SCHEDULE FOR SPECS f i Engineer/License Holder N A ARRAY CIRCUIT WIRING NOTES 1.)LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS AND EXECUTING INSTALLATION IN ACCORDANCE WITH NEC 2017 SOLAR MODULES MOUNTED TO ROOF ON 2 ARRAYS l0-3ISW MODULES WI I SOLAR EDGE P320 PER MODULE - 2.)LOW F5T EXPECTED AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB 8"XB• __ __ TT MK RALLIRE FOR ASHRAE LOCATION MOST SIMILAR TO SSTRING OF IB MODULES IN SERIES•3B0 Ana ____ .-- ]UNCTION - INSTALLATION LOCATION LOWEST EXPECTED AMBIENT CA BOX TEMP-l6'C "TERMINATED IN610E INVERTER I 3.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHEN HIGHEST MONTH 1%DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION.HIGHEST CONTINUOUS TEMP- 33°C 4.I 2005 ASHRAE FUNDAMENTALS 2%DESIGN \ -TE MPE NATURES DO NOT EXCEED 41'C IN THE UNITED ---- STATES(PALM SPRINGS.CA ISa ATT.FOR LESS THAN CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED Issued I Revisions SUNLIT CONDUIT AT LEAST 0.5.ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47"C OR LESS (ALL OF UNITED STATES) S.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT YI H.W-Yorex rm..n HP"' NYmY CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH NEC 690.12(4)THROUGH(DI NO_ DESCRIPTION DATE 6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERM,TEO Project Title: TO OPERATE WITH UNGROUNDED PHOTOVOL INC SOURCE AND OU FPO"CIRCUIT AS PER NEC 690.41(A)(4) GRUDZINA,ARLENE- 7.)UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED WITH THE FOLLOWING OUTER FINISH 1RINIT!ACCT E:1019-05-342217 POSITIVE CONDUCTORS=RED NEGATIVE CONDUCTORS=BLACF, p,,,.""�,,.Address: NEC 110.5(CR2) Project B.I ARRAY AND SUB ARRAY CONDUCTORS SHALL BE N10 PV EXISTING NO_- WIPE TYPE RH -1 OR EQUIVELANT AND SHALL BE 10 120/240V t 240V 10 TATEWNAL REVENUE GRADE MONITORING 151 BEACON STREET W PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT UTILITY METER fy' IOU1 MAIN BREABER CONTAINED WITHIN SOLAR EDGE INVERTER SOUTH YARMOUTH,MA 02664 torn BuseAR 41.667270,-70.197435 SUNLIGHT SUB0ARRAY T CARVIN LONGER THAN21"SHALL SOLAR EDGE PIE.RAND -MB CONTAINAlU ED TA CARVING CONDUCTORS AND . WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CON TAINII 9 CURRENT CARRYING CONDUCTORS. - DIRWBIg Title: ES 9.)ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLESS = OTHERWISE NOTED • SMART METER PROPOSED PV SOLAR SYSTEM 10.)FLFXIBIE CONDUIT SHALL NOT BE INSTALLED ON ". IOCNABLE 60A DISCONNECT PRODUCTION 60A MEUSED ROOFTOP AND SHALL BE LIMITED TO 12"IF USED • FUSED W/30A FUSES METER DISCONNECT OUTDOORS • n, INVERTER E3 D 11)OVEflCURNEN PROTECTION FOR CONDUCTORS 2400LlpsiRgX�It 24,s�iay.T,lw ).0 Drawing Information CONNECTED TOTHE SUPPLY SIDE OF A SERVICE SHALL BE = D u F9V°PPPF =n �eji LNG WTE: 6/3/2019 LOCATED WIT 1 N 10 OE T E PO T OF ONNE-TION NEC ` LJ� DR4WN BY MS 05.31 ��I���.�.�.HTTTIII ��HHIL ® - .�� T ...- REVISED BY12.)WHEPEiWO SOURCES FEEp ABUSSBAR.ONEA IRt+ '�RI a $ U �LP�I-{mil Y- UTIITYANDTHEOTHERANINVERTER.PV BACXEEED . B Oyy�',-'. B ♦ ♦ u N System Information: BREA PERISI SHALL BE LOCATED OPPOSITE FROM UTILITY r ot - ) I- 0O0 I NEC 705.12(BR2R3)(b) --__f ; _ I l 1 I -__ DC SYSTEM SITE: S.67XW EXISTING ETAPS A S A CENTER SQUARE O SQUARED ` vN J ACSYSTEM SIZE'. SAW ALL SOLARCIRCUEM LOAD CENTERSUNUSED POSITIONS ONLY INSULATED LINE INSTALLEDFEEDERS MODULES ON PM D322N DU221RB DU MODULE LDUNT. M GENERATION CIRCUITS AND NO UNUSED P051TION50R MAIN FEEDERS USED H0.NWNA 315 LOADS = NEC 706.12(A) MODULE SPEC N. OPEAX DUO BLX-SS 31S 14.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE UTILITY COMPANY: EVERSOURCE A NEMA 3R RATIN,L UTIIfIV ACRt 1486l350030 CALCULATIONS FOR CURRENT CARRYING CONNTORS UTILITY METER 4 1365416 OL REQUIRED CONDUCTOR 1.2S)L TV PER STRING DEAL TYPE: SUNNOVA .NEC RCfi90.B(B)(1)1:115.00•l.lSj1-IB.ISA PV MODULE SPECIFICATIONS AWG PIO.DERATED AMPACITY HANR'HA 315 IQDEAX DUO BLX-G531S) Rev.No. Shoot MOMENT TEMP:3VC,TEMP DERATING FACTOR.96 rEE THE RACEWAY DEBATING=2 CCC'.1.00 Imp 9.41 TOMEET Oa E1.10RAGTOCaSFnLO RECOMEEMSRTION('UtiiPAI?UR (40'-.96)1 W=38.40A Vmp 33.Z6 TO MEET On uCLLO NECrvLC ANC LDCALAHlO RLODmAN[nr5 P1 PV -j 38.40A118.754,THEREFORE WIRE SIZE IS VALID Mc 40.29 A NB THIY'N-Z DEC TO ELATING GROUND ROO TOTAL PC REQUIRED CONDUCTOR AMPACIT'I He 949 B 3/4"CONDUIT VI/2-N10 THWN-2,1410THWN-I,IMBSOTHWN-1 GROUND 21.00,1.25=26.25A C 3/4'CONDUIT W/2410 THWN.2,1M0 THWN..GROUND NAG N10,DE RATED AMPACTTY INVERTER NI-5E5000H-USODONNC2 AMBIENT TEMP:30'C,TEMP DERATING:10 M DC AC D 3/4"COMIT W/Zi10 THWN-1,1410 THWN.2 GROUND RACEWAY DERATING'3 CCC.N/A 404•1.0=40A Imp 13.5 Pout 5000 E 3/4"CONMIO W/1410 THWN-I,1419 THWN.2,1410 THWN-1 GROOM 4DA:26.25A,THEREFORE AC WIRE SIZE IS VALID HITS 380 Mum 21 Mc 4B0 OCDdnln 26.29 F YID PV WARE MIFF AIR.W{B6 BARE COFFER BOND TOAMAY SOLAR CALCULATION FOR PV OVERCURRENI PROTECTION TOTAL INVERTER CUPREN I:21.00A ER 15 Mom 240 A 3/I"CUIDUn W/3-B6 THVVNEIHI6 THWN2,t-4/THWN-3GRWND 2100A•1.25=26.25A 1l,A Road ---30A OVERCURRENT PROTECTION IS VALID Wall, R 411,Neeww leDeHu ey D>iA9 877186-7183