HomeMy WebLinkAboutBLD-20-1910GENERAL NOTES 1. THIS PROJECT AND ALL WORK ASSOCIATED WITH PROJECT SHALL CONFORM TO STATE AND LOCAL CODES AND ORDINANCES HAVING JURISDICTION OVER THIS PROJECT. 2. THE ARCHITECT SHALL NOT HAVE CONTROL OR CHARGE OF AND SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEAN, METHODS, TECHNIQUES, SEQUENCE OF PROCEDURE, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, ALL OF WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 3. THE DESIGN ADEQUACY, AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. DURING DEMOLITION AND/OR CONSTRUCTION IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR, AND HAS NOT BEEN CONSIDERED BY THE STRUCTURAL ENGINEER ORARCHITECT. 4. ALL WORK NOTED "N.I.C." OR "NOT IN CONTRACT" IS TO BE ACCOMPLISHED BY A CONTRACTOR OTHER THAN THE GENERAL CONTRACTOR AND IS NOT TO BE PART OF THE CONSTRUCTION AGREEMENT. THE GENERAL CONTRACTOR SHALL COORDINATE WITH "OTHER" CONTRACTORS PER REQUIREMENTS ESTABLISHED BY OWNER AND TENANT. 5. THE GENERAL CONTRACTOR AND, ALL SUBCONTRACTORS ARE RESPONSIBLE FOR EXAMINING CONTRACT DOCUMENTS, FIELD CONDITIONS, AND CONFIRMING THAT WORK IS BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IF THERE ARE ANY QUESTIONS REGARDING THESE OR OTHER COORDINATION ITEMS, THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH WORK IN QUESTION OR RELATED WORK. 6. CONTRACTOR SHALL MAINTAIN RECORD DOCUMENTS OF CONSTRUCTION CHANGES ("AS -BUILT DRAWINGS") AND SHALL PROVIDE SAID DOCUMENTATION TO THE ARCHITECT UPON COMPLETION OF CONSTRUCTION - NO EXCEPTION ALLOWED. 7. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE TO COORDINATE WITH ALL SUBCONTRACTORS PER REQUIREMENTS ESTABLISHED BY OWNER, TENANT, OR BOTH, WHICH ARE UNDER SEPARATE CONTRACT WITH THE OWNER, OR TENANT, OR BOTH. 8. INSTALL ALL MANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT IN STRICT ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS, U.N.O.. 9. ANY WORK INSTALLED IN CONFLICT WITH THE CONSTRUCTION DRAWINGS, WITHOUT THE PRIOR APPROVAL OF THE OWNER AND THE ARCHITECT SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. 10. THE GENERAL CONTRACTOR SHALL NOTIFY THE OWNER/ ARCHITECT IMMEDIATELY OF ANY SPECIFIED MATERIALS OR EQUIPMENT WHICH ARE EITHER UNAVAILABLE OR THAT WILL CAUSE A DELAY IN THE CONSTRUCTION COMPLETION SCHEDULE. THE CONTRACTOR SHALL SUBMIT CONFIRMATIONS OF DELIVERY DATES FOR ORDERS OF MATERIALS AND EQUIPMENT HAVING LONG LEAD TIMES. 11. ALL REQUEST FOR SUBSTITUTIONS OF ITEMS SPECIFIED SHALL BE SUBMITTED IN WRITING AND WILL BE CONSIDERED ONLY IF BETTER SERVICE FACILITIES, A MORE ADVANTAGEOUS DELIVERY DATE, OR A LOWER PRICE WITH CREDIT TO THE OWNER/ TENANT WILL BE PROVIDED WITHOUT SACRIFICING QUALITY, APPEARANCE, AND FUNCTION. UNDER NO CIRCUMSTANCES WILL THE ARCHITECT BE REQUIRED TO PROVE THAT A PRODUCT PROPOSED FOR SUBSTITUTION IS OR IS NOT OF EQUAL QUALITY TO THE PRODUCT SPECIFIED. 12. PROJECT SPECIFICATIONS ARE AN INTEGRAL PART OF THESE PLANS - SUBSTITUTIONS FOR SPECIFIED MATERIALS REQUIRE THE WRITTEN APPROVAL FROM THE ARCHITECT, 13. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED BUILDING PERMITS PRIOR TO STARTING CONSTRUCTION. 14. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, THE APPLICANT SHALL HAVE EVIDENCE OF CURRENT WORKMAN'S COMPENSATION INSURANCE COVERAGE ON FILE WITH THE STATE LABOR DEPARTMENT IN COMPLIANCE WITH CURRENT LABOR CODES. 15. PROVIDE CONTINUOUS INSPECTIONS AS SET FORTH IN STATE AND LOCAL CODES AND PER CONTRACT DOCUMENTS AS NEEDED. 16. CONTRACTOR SHALL VERIFY ALL BUILDING STANDARDS WITH BUILDING LANDLORD PRIOR TO BEGINNING ANY WORK. HOWEVER, THERE SHALL RE NO DEVIATIONS WHATSOEVER FROM THE CONTRACTOR DOCUMENTS WITHOUT THE ARCHITECT'S WRITTEN APPROVAL THEREOF. THE CONTRACTOR AGREES TO DEFEND, INDEMNIFY AND HOLD THE ARCHITECT HARMLESS FROM ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES. DRAWING NOTES 1. UNLESS OTHERWISE NOTED OR INDICATED, ALL DIMENSIONS ON THESE DOCUMENTS SHALL BE TO FACE OF CURB, FACE OF CONCRETE OR MASONRY, FACE OF FINISH OR CENTERLINE OF GRIDS. 2. ALL VERTICAL DIMENSIONS SHOWN ARE FROM FLOOR SLAB, U.O.N.. 3. DIMENSIONS SHOWN IN FIGURES TAKE PRECEDENCE OVER DIMENSIONS SCALED FROM DRAWINGS, LARGE SCALE DRAWINGS AND DETAILS TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS. 4. THE TERM "ALIGN" AS USED IN THESE DOCUMENTS, SHALL MEAN TO ACCURATELY LOCATE FINISHES IN THE SAME PLANE. 5. "TYPICAL" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITION IS THE SAME OR REPRESENTATIVE FOR ALL SIMILAR CONDITIONS THROUGHOUT, U.N.O.. 6. DETAILS ARE USUALLY KEYED AND NOTED "TYPICAL" ONLY ONCE, WHEN THEY FIRST OCCUR AND ARE REPRESENTATIVE OF ALL SIMILAR CONDITIONS THROUGHOUT, U.NA.. 7. COLUMN CENTERLINES (GRID LINES) ARE SHOWN FOR DIMENSIONING PURPOSES. 8. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK IN THE SAME BUILDING. INTERIOR 1 EXTERIOR NOTES 1. WHERE ELECTRICAL, MECHANICAL AND/OR PLUMBING ITEMS, SUCH AS LIGHTS, DUCTS, PIPING, DOWNSPOUTS, ETC.. ARE TO PENETRATE ANY BUILDING FOOTINGS, SLABS, FLOORS, STRUCTURAL FRAMING, WALL PARTITIONS, CEILINGS, ETC., IT IS REQUIRED THAT AN APPROPRIATELY SIZED OPENING OR CLEARANCE BE FURNISHED. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL ITEMS WITH THE CONSTRUCTION DOCUMENTS PRIOR TO THE INSTALLATION OF STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL WORK. ANY CONFLICT OR DISCREPANCY WITHIN CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION. 2. ALL PENETRATIONS AT RATED CONSTRUCTION SHALL BE PROTECTED TO MAINTAIN RATING. 3. WHERE OCCURS, CONTRACTOR SHALL PATCH ANY EXISTING WALLS AND/OR CEILINGS AS NEEDED TO REFURBISH THE LEASE SPACE AND REPAIR ALL DAMAGES CAUSED BY CONTRACTOR. 4. INTERIOR WALLS AND CEILINGS SHALL BE INSTALLED IN ACCORDANCE TO STATE AND LOCAL CODES, INCLUDING REQUIREMENTS FOR FLAME SPREAD AND SMOKE DENSITY RATING FOR FINISH MATERIALS. 5. WHEN USED, ALL NOISE BARRIER BATTS (SOUND INSULATION) AND INSULATION BATTS SHALL BE NON-COMBUSTIBLE AND SHALL NOT CONTAIN OR UTILIZE OZONE DELETING COMPOUNDS. 6. ALL NEW CONSTRUCTION MATERIALS SHALL BE 100% ASBESTOS -FREE. 7. CONTRACTOR, ALONG WITH MECHANICAL CONTRACTOR, SHALL PROVIDE AND LOCATE ACCESS DOORS/ PANELS IN WALL & CEILING CONSTRUCTION AS REQUIRED TO PROVIDE ACCESS TO MECHANICAL, FIRE SPRINKLER, PLUMBING & ELECTRICAL WORK. TENANT COMCAST ONE COMCAST CENTER 1701 JFK BLVD. 25TH FLOOR - 25.425 PHILADELPHIA, PA 19103 CONSTRUCTION MANAGER: Brian Jackson 917.932.4609 bjackson@macropm.com DESIGN MANAGER: REBECCA FORSBERG 215.286.1545 rebecca--forsberg@comcast.com DESIGN MANAGER: CAROLYN RAU 215.286.5760 carotyn_rau@comcast.com SYMBOLS LEGEND DETAIL REFERENCE ROOM NAME Room name Sim 101 ROOM NUMBER ( ` 1 NEW DOOR SHEET NUMBER 101 � A101 DETAIL SECTION REFERENCE DOOR 1 SIM NUMBER A101 101 SHEET NUMBER EXISTING SECTION REFERENCE DOOR SIM A101 SHEET NUMBER FINISH p MATERIAL 1 Ref.., ELEVATION REFERENCE F.E. FIRE EXTINGUISHER f SHEETNUMBER 1 Re WALL TYPE ELEVATION 1i Name � HEIGHT Elevation 1t WINDOWTYPE CEILING MATERIAL CLG. MATERIAL REVISION CLOUD CLG. HT. i ' r DELTA CEILING HT ARCHITECT ROBERT F. VANNEY ARCHITECT 55 EAST 5TH ST. SUITE 750 ST. PAUL, MN 55101 CONTACT: ROBERT F.VANNEY PHONE: (651) 294-7602 FAX: (651) 222-3034 bob.vanney@vanneyassociates.com LONG LEAD TIME ITEMS THE FOLLOWING ITEMS ARE CONSIDERED TO HAVE LONG LEAD TIMES. 1. WIRE CRAFTERS WIRE PARTITIONS MODULAR SYSTEM. GENERAL CONTRACTOR JDR FIXTURES, INC 264 SHOEMAKER ROAD POTTSTOWN, PA, 19464 CONTACT: KEITH T. SORRENTINO 610.323.6599 keiths@jdrrixtures.com VENDORS MILLWORK SPARKS 2828 CHARTER ROAD PHILADELPHIA, PA 19154 CONTACT: ED JANKINS 215.602.8062 ejankins@sparksonline.com INTERACTIVE DMG 385 MARKET ST KENILWORTH, NJ 07033 CONTACT: PETER KENEZ 908.445.2560 SIGNAGE • EXTERIOR ADVANCE SIGN GROUP 5150 WALCUTT COURT COLUMBUS, OH 43228 CONTACT: ANDY WASSERSTROM 614.429.2140 CEILINGS ARMSTRONG 2500 COLUMBIA AVE LANCASTER, PA 17603 CONTACT: MAUREEN CONE 703.389.2701 mmcone@armstrongceilings.com CONSULTANTS MEP ENGINEER HALLBERG ENGINEERING, INC. 1750 COMMERCE COURT WHITE BEAR LAKE, MN 55110 CONTACT: DAVE QUIGLEY 651.748.1100 dqu ig ley@hallberg eng i neeri ng.com LIGHTING CS ILLUMINATION 1210 KEYSTONE WAY, SUITE A & B VISTA, CA 92081 CONTACT: ALLISON LEWIS 760.477.1244 afewis@csilluminafion.com FLOORING TAN DUS CENTIVA US LLC 385 MARKET ST. KENILWORTH, NJ 07033 CONTACT: MATT SHIELDS 440.903.4680 matt.sh ields@tarkett.com Ar law m y . .. 4 �..,.n.,,. I C�NTER �A,.. �.. to-. ,.. - z '.,...= w,.,«,"...", TENANT LOCATI XFINITY 10 OLD TOWNHOUSE RD SOUTH YARM( 10 SOUTH TOWNHOUSE RD YARMOUTH. MA 02664 FOR TENANT IMPROVEMENT ONL ABBREVIATIONS @ AT DIAG DIAGONAL SHEETINDEX LL Review 8127119 Permit Set 8127/19 Bid Set 8/27/19 Revision 1 Revision 2 Revision 3 Revision 4 1 Sheet Number Sheet Name REQ'D. REQUIRED IE PROPERTY LINE X X X AO.1 TITLE SHEET X X X AO.2 2010 ADAACCESSIBILITY DETAILS X X X AO.3 SPECIFICATIONS X X X A1.0 DEMOLITION PLAN X X X A2.0 FURNITURE, FIXTURE & EQUIPMENT PLAN X X X A3.0 REFLECTED CEILING PLAN X X Ix A4.0 TERIOR ELEVATIONS X X X E1.0 ECTRICAL SYMBOL LEGEND, POWER AND LOW VOLTAGE PLAN RECTRICAL X X X E2.0 SPECIFICATIONS X Ix Ix S.C. @ AT DIAG DIAGONAL HDWR HARDWARE REINF. REINFORCING Ck CENTERLINE DIM DIMENSION Read HM HOLLOW METAL REQ'D. REQUIRED IE PROPERTY LINE DN DOWN HT HEIGHT REV REVISION # POUNDORNUMBER DR DOOR HVAC HEATINGNENTILATING/ RM ROOM H DIAMETER DS DOWNSPOUT -1-► CL AIRCONDITIONING RO ROUGH OPENING 0 SQUARE FEET DWG DRAWING HW HOT WATER RCP REFLECTED CLNG A.B. ANCHOR BOLT cn U ('3 HEATER PLAN A/C AIR CONDITIONING EA EACH INS. INSULATION S.C. SOLID CORE ACC. ACCESSIBLE E.I.F.S. EXTERIOR INSULATED INT INTERIOR SCHO'L SCHEDULE ACT ACOUSTIC TILE FINISH SYSTEM SLNT SEALANT ADJ ADJACENT E.J. EXPANSION JOINT JT JOINT - SECT. SECTION AFF ABOVE FINISH FLOOR ELEV ELEVATION SF SQUARE FEET ALT ALTERNATE ELEC. ELECTRIC(AL) LAM. LAMINATE(D) SIM SIMILAR ALUM ALUMINUM ENCL. ENCLOSE(URE) - LAV. LAVATORY SPEC SPECIFICATION APPROX. APPROXIMATE EQ EQUAL SQ SQUARE ARCH ARCHITECT EQUIP EQUIPMENT MAS. MASONRY SS STAINLESS STEEL AN AUDIONISUAL EST. ESTIMATE MAX MAXIMUM STD. STANDARD EXH. EXHAUST MED. MEDIUM STL STEEL BD BOARD EXIST EXISTING MEMB. MEMBRANE STOR. STORAGE BLDG BUILDING EXT EXTERIOR MEZZ. MEZZANINE SUSP. SUSPENDED BLKG BLOCKING MFR. MANUFACTURE(R) B.M. BENCH MARK / MIN MINIMUM TEL. TELEPHONE BID BOTTOM FDIC FURNISHED BY OWNER MISC MISCELLANEOUS TEMP TEMPERED OF INSTALLED BY CONTRACTOR MTD MOUNTED THK THICK(NESS) CER. CERAMIC FOIO FURNISHED BY OWNER MTL METAL TV TELEVISION C.G. CORNER GUARD INSTALLED BY OWNER TYP TYPICAL GJ CONTROL JOINT F.D. FLOOR DRAIN N.I.C. NOT IN CONTRACT APPROVED EXIT ROUTE CLG. CEILING F.E. FIRE EXTINGUISHER N.T.S. NOT TO U.N.O. UNLESS NOTED CLR CLEAR(ANCE) F.E.C. FIRE EXTINGUISHER CABINET SIGNAGE - SEE SHT AO.2 SCALE Z OTHERWISE CMU CONCRETE MASONRY UNIT FP. FIREPROOF OC ON CNTR COUNTER FT FOOT, FEET CENTER VCT VINYL COMPOSITION TILE C.O. CLEAN FTG FOOTING RLAM PLASTIC LAMINATE V.I.F. VERIFY IN COL 00¢UMN FURR FURRED, PLYWD PLYWOOD FIELD CONC CONCRETE FURRING PR. PAIR W/ WITH CONT CONTINUOUS GA. GAGE P.S.F. POUNDS PER SQ. FOOT W.C. WATER CLOSET CPT CARPET GALV. GALVANIZED P.S.I. POUNDS PER SQ. INCH WD WOOD C.T. CERAMICTILE G.B. GRAB BAR P.T. PRESSURE TREATED W.H. WATER HEATER CTR. CENTER GEN. GENERAL P.T.D. PAPER TOWEL W/O WITHOUT CU FT CUBIC FOOT GL. GLASS, GLAZING DISPENSER cm CU CUBIC GWB GYPSUM WALL BOARD R/A RETURN AIR N.I.C. , - / YD YARD GYP. GYPSUM R.D. ROOF DRAIN DEMO DEMOLITION 1; REF. REFERENCE ADJAOENT AREA DBL DOUBLE H.B. HOSE BIBB REFR. REFRIGERATOR DETL DETAIL HDR HEADER REG. REGISTER Date 09/13/2019 O.F. DRINKING E LAN FOUNTAIN Drawn By RFV N S ON MAP VICINITY MAP W E XFINITY 10 OLD TOWNHOUSE RD SOUTH YARMOUTH, MA 02664 r N W(lE S PROJECT DATA CITY OF SOUTH YARMOUTH YARMOUTH TOWN HALL 1146 ROUTE 28 SOUTH YARMOUTH, MA 02664 9TH EDITION 780 CMR BUILDING CODE 9TH EDITION 780 CMR MECHANICAL CODE 9TH EDITION 780 CMR ELECTRICAL CODE 9TH EDITION 780 CMR STRETCH ENERGY CODE 9TH EDITION 780 CMR PLUMBING CODE 9TH EDITION 780 CMR FIRE CODE 9TH EDITION 780 CMR CHAPTER 11 ACCESSIBILITY EXIT 1/8" -1"-0" USE GROUP: CONSTRUCTION TYPE: HEIGHT IN STORIES: MERCANTILE VB SPRINKLERED 1 USE GROUP: MERCANTILE SALES AREA SQUARE FOOTAGE: 580 S.F. / 60 = 10 OCC. ry d - W c� e I Town' m Read N LV U Q O W t^. U_ p= / W F- Wr^ U)0 I� VJ Z) W Z Q DRAWINGS BASED ON QUININE TEST FIT D N W(lE S PROJECT DATA CITY OF SOUTH YARMOUTH YARMOUTH TOWN HALL 1146 ROUTE 28 SOUTH YARMOUTH, MA 02664 9TH EDITION 780 CMR BUILDING CODE 9TH EDITION 780 CMR MECHANICAL CODE 9TH EDITION 780 CMR ELECTRICAL CODE 9TH EDITION 780 CMR STRETCH ENERGY CODE 9TH EDITION 780 CMR PLUMBING CODE 9TH EDITION 780 CMR FIRE CODE 9TH EDITION 780 CMR CHAPTER 11 ACCESSIBILITY EXIT 1/8" -1"-0" USE GROUP: CONSTRUCTION TYPE: HEIGHT IN STORIES: MERCANTILE VB SPRINKLERED 1 USE GROUP: MERCANTILE SALES AREA SQUARE FOOTAGE: 580 S.F. / 60 = 10 OCC. ry d - W c� Z N LV U Q O W � U_ p= / W F- Wr^ U)0 VJ Z) W Z Q DRAWINGS BASED ON QUININE TEST FIT D -1-► CL 0 S: W 0 D Z) 00 U r-- cn U ('3 TM I� W C O -1-► CL U W ADJACENT AREA / "' N f C EXISTING - REVIEWED FC, I I ly ;ANO ^V";3 CODE COMPLI- ® VESTIBULE ANCE. ERRORS V t (::JSSIO,'a CO NOT RELIEVE THE APPGCA NT FROM THE F-SPO?VVFIUiY OF "AS BUILT" COMPLIANCE. DATE: to jS'A8 / APPROVED EXIT TACTILE SIGNAGE -SEE SHTA0.2 BUILDINGOFFIU L FOR SIGNAGE DETAILS APPROVED EXIT ROUTE O SIGNAGE - SEE SHT AO.2 Z FOR SIGNAGE DETAILS COMMON PATH OF HATCHED AREAE e5 TRAVEL 48'-9" ��L f".y � Bid Issue: 09/13/2019 :INDICATES Landlord Issue: 09/13/2019 EXISTING TO RETAIL / REMAIN NO ! Permit Issue: 09/13/2019 WORK IN THESE'; AREAS 101 Construction Issue: T.B.D. i' cm TITLE SHEET ADJACENT AREA"� ATH OF EGRESS 44" MINIMUM N.I.C. , - / �'-/ 1; ADJAOENT AREA NICs Comm. Number $3-1189 Date 09/13/2019 E LAN Drawn By RFV N S Checked By RFV W 0,1 GENERAL NOTES 403 WALKING SURFACES 604 WATER CLOSETS THE INTENTION OF THIS SHEET IS TO SHOW THE REQUIREMENTS OF THE 2010 ADA DESIGN STANDARDS. BASED ON PROJECT LOCATION, STATE OR LOCAL 403.3 S403.2 lope. e. The runnioor or Ground ng slope of walkinrface. Floor or g shall notound surfaces be steeper lyithan th 01:20 The cross slope of walking surfaces shall not be steeper than 1:48. 2. 17" (PREFERRED - 36" MIN 54"MIN ACCESSIBILITY CODES MAY ALSO APPLY TO THE PROJECT. IF THERE IS A DISCREPANCY BETWEEN THE FEDERAL, STATE, OR LOCAL CODE THEN THE P g P gVERIFY STATE CODE) 24" MIN 12" MIN 2" 42" MIN STRICTER OF THE CODES SHALL BE ENFORCED IN THAT SITUATION. 403.4 Changes in Level. Changes in level shall comply with 303. 403.2 Floor or Ground Surface. Floor or ground surfaces shall comply with 302. JW 39" TO 41" 403.3 Slope. The running slope of walking surfaces shall not be steeper than 1:20. The cross slope of walking surfaces shall not be steeper than 1:48. C/L THE COMPLETE FEDERAL AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES CAN BE FOUND AT: http://www.access-board.gov/ada-aba/final.pdf 403.4 Changes in Level. Changes in level shall comply with 303. 1 TOILET PAPER o0 GENERAL NOTES: 7o 1. IF THE REQUIREMENTS OF THIS SHEET CANNOT BE ACHIEVED FOR ANY REASON THEN THE G.C. SHOULD NOTIFY THE ARCHITECT IMMEDIATELY. 403.5 CLEAR WIDTH 0 F AN ACCESSIBLE ROUTE _ _ OLL(9w 0LL0Lu TRANSFER I ~0z0 �� �OZQ a /SIDE C? (L iQ aMA) 48" MIN 4" MA) co 7-9' r MFIN IN 302 FLOOR OR GROUND SURFACES AND 303 CHANGES IN LEVEL ZEOF Z FIG. 604.3.1 SIZE OF CLEARANCE FIG. 604.5.2 REAR WALL GRAB FIG. 604.5.1 SIDE WALL GRAB AT WATER CLOSETS BAR AT WATER CLOSETS BAR AT WATER CLOSETS M 302.1 General. Floor and ground surfaces shall be stable, firm, and slip resistant. co =CM4 IB� 302.2 Carpet. Carpet or carpet tile shall be securely attached and shall have a firm cushion, pad, or backing or no cushion or pad. Carpet or carpet tile shall have a level loop, textured loop, level cut pile, or level cut/uncut pile texture. Pile height shall be % " max. Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge. Carpet edge trim shall comply with 303. FIG. 403.5 CLEAR WIDTH OF AN ACCESSIBLE ROUTE 303.2 Vertical. Changes in level of%" high max shall be permitted to be vertical. 303.3 Beveled. Changes in level between'/." high min and 1/2 " high max shall be beveled with a slope not steeper than 1:2. 404 DOORS 606 LAVATORIES AND MIRRORS CARPET PILE THICKNESS & ACCESSIBLE ROUTE404606.2 Clear Floor Space. A clear floor space complying with 305, positioned for a forward 404.2.2 Double -Leaf Doors and Gates: At least one of the active leaves of doorways with two leaves shall comply with .2.3 and 404.2.4. 404.2.3 Clear Width. Door openings shall provide a clear width of 32" min. Clear openings of doorways with swinging doors shall be measured between the face of the door and approach, and knee and toe clearance complying with 306 shall be provided. the stop, with the door open 90 degrees. Openings more than 24" deep shall provide a clear opening of 36" min. There shall be no projections into the required clear opening 606.3 Height. Lavatories and sinks shall be installed with the front of the higher of the rim 2 width lower than 34" above the finish floor or ground. Projections into the dear opening width between 34" and 80" above the finish floor or ground shall not exceed 4". or counter surface 34" max above the finish floor or ground. MIRROR 404.2.4 Maneuvering Clearances. min maneuvering clearances at doors and gates shall comply with 404.2.4. Maneuvering clearances shall extend the full width of the dfaucets 10 seconds min. oorway Faucets. Controls for faucets shall comply with 309. Hand -operated meter ng N and the required latch side or hinge side clearance. faucets shall remain open for f rfa 404.2.5 Thresholds. Thresholds, if provided at doorways, shall be'/ " high max. Raised thresholds and changes in level at doorways shall comply with 302 and 303. 606.5 Exposed Pipes and Surfaces. Water supply and drain pipes under lavatories and 404.2.6 Doors in Series and Gates in Series. The distance between two hinged or pivoted doors in series and gates in series shall be 48" min plus the width of doors or gates sinks shall be insulated or otherwise configured is protect against contact. There shall 8" MIN. KNEE be no sharp or abrasive surfaces under lavatories and sinks. CLEARANCE swinging into the space. 603.3 Mirrors. Mirrors located above lavatories or countertops shall be installed with the le Le operable arts on doors and gates shall comply with 309.4. Operable parts of such hardware shali be bottom edge of the reflecting surface 40" max above the finish floor or ground. Mirrors locks and other o P Y 9 Handles pulls, latches,9 9 404.2.7 Door and Gate Hardware., pP P FIG. 302.3 CARPET PILE THICKNESS FIG. 303.2 CHANGES IN LEVEL FIG. 303.3 BEVELED CHANGE IN LEVEL 34" min and 48" max above the finish floor or ground. Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides. not located above lavatories or countertops shall be installed with the bottom edge of LL cwt o 404.2.8.1 Door Closers and Gate Closers. Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a the reflecting surface 35" max above the finish floor or ground. O position of 12 degrees from the latch is 5 seconds min. C/L 0 � LU 0 Lu O U 304 TURNING SPACE TURNING SPACE AND CLEAR FLOOR S PAC E 404.2.9 Door/ Gate Opening Force. Fire door shat have a min opening force allowable b theappropriate administrative authority. force for pushing or pulling open a k - - - - 1 a z w w z door/gate other than fire doors shall be as follows: 71 w w O z U p g P 9 YY P 9 Interior hinged doors and gates: 5 pounds max. Sliding or folding doors: 5 pounds max. °x� z Y ZQ ~ U Y w 304.2 Floor or Ground Surfaces. Floor or ground surfaces of a 60" MIN z W Z Q O w , rn U turning space shall comply with 302. Changes in level are not U 0 LL w L - GATES IN SERIES W N� ME N� permitted. CLEAR DOOR WIDTH DOORS AND EXCEPTION: Slopes not steeper than 1:48 shall be / z 1 permitted. \� arm arm/ 48" MIN I- - - J 304.3.1 Circular Space. The turning space shall be a space of 60" z co J o Z 4 ^ 30" MIN. KNEE Z_ 32' MIN diameter min. The space shall be permitted to include knee and l � � CLEARANCE 6" MAX. TOE o Z r m 8" MIN 48' MIN 48' MIN CLEARANCE toe clearance complying with 306.:7 7 17" MIN DEPTH 304.3.2 T -Shaped Space. The turning space shall be a T-shaped \ / o �O �? �? 30" MIN space within a 60" square min with arms and base 36" wide \ \ / base - v " CLR. FRONT ELEVATION SIDE ELEVATION rr min. Each arm of the T shall be clear of obstructions 12" min. in L - - - - FIG. 404.2.3(a) CLEAR WIDTH each direction and the base shall be clear of obstructions 24" 60" MIN 12" 12" OF DOORWAYS FIG. 404.2.6 DOORS IN SERIES AND GATES IN SERIES min. in each direction. The space shall be permitted to include IN 36" MIN IN 609 GRAB BARS knee and toe clearance complying with 306 only at the end of FIG. 305.3 either the base or 1 arm. FIG 1 CIRCULAR TURNING SPACEFIG. 304. 1.2 T -SHAPED TURNING SPACE CLEAR FLOOR SPACE 404.2.4 PULL SIDE MANEUVERING CLEARANCES AT DOOR E FRONT APPROACH HINGE APPROACH #1 HINGE APPROACH #2 LATCH APPROACH LATCH APPROACH 609.2.1 Circular Cross Section. Grab bars with circular cross sections shall have an outside diameter of 1 %z' '/." min and 2" max. 305 CLEAR FLOOR OR GROUND SPACE 609.3 Spacing. The space between the wall and the grab bar shall be 1. The space between the grab bar and projecting objects below and at the ends shall be /z " min. The space between the grab bar and projecting objects above shall be 12" min. IN 609.4 on of Grab Bars. Grab bars installe in a horizontal 36" max above he floor d to 305.2 Floor or Ground Surfaces. Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. r - - - - - - - r 609.5 Surface Hazards. Grab as and anylw a or othedr surfces adjacent tot grab bas shallbebe free of sharp torr abrlasive el ments and shal have nded gripping surface. EXCEPTION: Slopes not ateeper than 1:48 shall be permitted. % \ 609.6 Fittings. Grab bas shall not rotate within their fittings. s ace shall be 30" min b 48" min. U i'\ 609.7 Installation. Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space. 305.3 Size. The clear floor or ground p Y / 305.4 Knee and Toe Clearance. Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306. o o �, rO l \ 609.8 Structural Strength. Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds is applied at any point on the grab bar, fastener, 305.5 Position. Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element. n -� ✓ \ \� I mounting device, or supporting structure. 1-6 T-0' -I - - 2, p„ J -- --'J 703 SIGNS 306 KNEE AND TOE CLEARANCE "21.0 ***NO CLOSER ***WITH CLOSER 703.1 General. Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual, 306.2 Toe Clearance. 306.2.1 General. Space under an element between the finish floor or ground and 9" above the finish floor or ground shall be considered AT DOOR and one with tactile characters, shall be provided. toe clearance and shall comply with 306.2. 404 .2 .4 PUSH SIDE MANEUVERING CLEARANCES 703.2 Raised Characters. Raised characters shall comply with 703.2 and shall be duplicated in braille complying with 703.3. Raised characters shall be installed in accordance with 703.4. 703.2.1 Depth. Raised characters shall be 1132" min above their background. 306.2.2 Max Depth. Toe clearance shall extend 25" max under an element. 703.2.2 Case. Characters shall be uppercase. 306.2.3 min Required Depth. Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17" min under the element. FRONT APPROACH HINGE APPROACH LATCH APPROACH FRONT APPROACH HINGE APPROACH I LATCHAPPROACH703.2.3 Style. Characters shall be sans serif. Characters shall not on italic, oblique, script, highly decorative, er of other unusual forms. .. �� � round "MIN _ _ 703.2.4 Character Proportions. Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 percent min and 110 percent max of the height of the uppercase letter "I". 306.2.4 Additional Clearance. Space extending greater than 6 beyond the available knee clearance at 9 above the finish floor or g r r - - - " j - ` , 703.2.5 Character Height. Character height measured vertically from the baseline of the character shall be 5/8" min and 2" max based on the height of the uppercase letter shall not be considered toe clearance. - - r height shall be permitted to be 112" min. 306.2.5 Width. Toe clearance shall be 30" wide min. n z U l / EXCEPTION: Where separate raised and visual characters with the same information 15 per are provided, raised charade g 3 Knee Clearance. z o -, � o o \ 0 703.2.6 Stroke Thickness. Stroke thickness of the uppercase letter "I" shall be 15 percent max of the height of the character. 306 - 1 < / v rn 703.2.7 Character Spacing. Character spacing shall be measured between the two closest points of adjacent raised characters within a message, excluding word spaces. Where characters have above the finish floor or round shall be considered knee clearance and v 306.3.1 General. Space under an element between 9" and 27" abo 9 shall comp/ with Space un -71 M r> \� rectangular cross sections, spacing between individual raised characters shall be 1/8" min and 4 times the raised character stroke width max. Where characters have other cross sections, yV Depth. Knee clearance shall extend 25" max under an element at 9" above the finish floor or ground. I -- ---spacing between individual raised characters shall be 1116 inch min and 4 times the raised character stroke width max at the base a the cross sections, and 1/8"min and 4 times the raised 306.3.2 Max Dep L - - character stroke width max at the top of the cross sections. Charactes shall be separated from raised bordes and decorative elements 3!8" min. 306.3.3 min Required Depth.Where knee clearance is required underan elementas partof a clear floor space, the knee clearance shall be 11"dee min at 9" above the finish floor or ground, and 8" deep min at 27 above the finish floor or ground. 11" MIN 1'_1 p" 2'-0" 1'-10" 2'_p^ 703.2.8 Line Spacing. Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent min and 170 percent max of the raised character height. P 306.3.4 Clearance Reduction. Between 9" and 27" above the finish floor or ground, the knee clearance shall be permitted to reduce at a 703.3 Braille. Braille shall be contracted (Grade of and shall comply with 703.3 and 703.4. rate of 1" in depth for each 6" in height. FIG. 306.2(a) TOE FIG. 306.3(a) KNEE 1'-0" 703.3.1 Dimensions and Capitalization. Braille dots shall have a domed or rounded shape and shall comply with Table 703.3.1. The indication of an uppercase letter or letters shall only be used 306.3.5 Width. Knee clearance shall be 30" wide min. CLEARANCE CLEARANCE before the first word of sentences, proper nouns and names, individual letters of the alphabet, initials, and acronyms. 703.3.2 Position. Braille shall be positioned below the corresponding text. If text is multi -lined, braille shall be placed below the entire text. Braille shall be separated 3/8" min from any other tactile characters and 3/8" min from raised borders and decorative elements. 703.4 Installation Height and Location. Signs with tactile characters shall comply with 703.4. 307 PROTRUDING OBJECTS *** WITH CLOSER ***WITH CLOSER ***WITH CLOSER ***WITH CLOSER *** WITH CLOSER *** WITH CLOSER 703.4 .1 Height Above Finish Floor or Ground. Tactile characters on signs shall be located 48" min above the finish floor or ground surface, measured from the baseline of the lowest tactile OR LATCH OR LATCH OR LATCH AND LATCH AND LATCH character and 60" max above the finish floor or ground surface, measured from the baseline of the highest tactile character. 703.4.2 Location. Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with on 307.2 Protrusion Limits. Objects with leading edges more 4" MAX. ANY AMOUNT e active leaf, the sign shall be located on the inactive leaf. Where a tactile sign is provided at double doors with two active leafs, the sign shall be located to the right of the right hand door. Where there is no than 27" and not more than 80" above the finish floor or " horizontally into the wall space at the latch side of a single door or at the right side of double door, signs shall be located on the nearest adjacent wall. Signs containing tactile characters shall be located sot at circulation 1protrude 4 max ho y 602 DRINKING FOUNTAINS circulation path. a clear floor space of 18" min by 18" min, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position. e Vertical clearance shall be 80" high EXCEPTION: Signs with tactile characters shall be permitted on the push side of door with closers and without hold -open devices. comply with 703.5. 307.4 Vertical Clearance. 703.5 Visual Characters. Visual characters shallco p y be provided where 602.2 Clear Floor Space. Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit. Knee and toe clearance complying with EXCEPTION: Where visual characters corn with 703.2 and are accompanied b braille complying with 703.3, the shall not be required to comply with 703.5.2 through 703.5.9. min. Guardrails or other barriers shallp the vertical clearance is less than 80" high. The leading 306 shall be provided. PY P Y Y g y q P Y edge of such guardrail or barrier shall be located 27" max 602.3 Operable Parts. Operable parts shall comply with 309. 703.5.1 Finish and Contrast. Characters and their background shall have anon -glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on a light background. above the finish floor or ground. Z 602.4 Spout Height. Spout outlets shall be 36" max above the finish floor or ground. 703.5.2 Case. Characters shall be uppercase or lowercase or a combination of both. Required Clear Width. Protruding objects shall not 602.5 Spout Location. The spout shall be located 15" min from the vertical support and 5" max from the front edge of the unit, including bumpers. 703.5.3 Style. Characters shall be conventional in form. Charactersshall not be italic, oblique, script, highly decorative, or of other unusual forms. reduce the clear width required for accessible routes. 602.6 Water Flow. The spout shall provide a flow of water 4" high min and shall be located 5" max from the front of the unit. The angle of the water stream shall be measured horizontally relative 703.5.4 Character Proportions. Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 percent min and 110 percent max of the height of the uppercase letter "I". � � � to the front face of the unit. Where spouts are located less than 3" of the front of the unit, the angle of the water stream shall be 30 degrees max. Where spouts are located between 3" and 5 703.5.5 Character Height. min character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction =Z O O g max from the front of the unit, the angle of the water stream shall be 15 degrees max. O Q 0 w 602.7 Drinking Fountains for Standing Persons. Spout outlets of drinking fountains for standing persons shall be 38" min and 43" max above the finish floor or ground. 703.5.6 Height From preventing further approach towards the sign. Character height shall be based on the uppercfloor or ase letter "I". _ C`1 m N 703.5.7 Stroke Thickness. Stroke thicknish Floor or ness of theauppercaserlett all be shall be 10 percent min and 30 percent max of the height of the character. 1'-5" MI . 703.5.8 Character Spacing. Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be FIG 2 PARALLEL TO A WALL FIG 3 PERPENDICULAR TO A WALL 191.10 percent min and 35 percent max of character height. L 703.5.9 Line Spacing. Spacing between the baselines of separate lines of characters within a message shall be 135 percent min and 170 percent max of the character height. 703.6 Pictograms. Pictograms shall comply with 703.6. 308 REACH RANGES 0 - 703.6.1 Pictogram Field. Pictograms shall have a field height of 6" min. Characters and braille shall not be located in the pictogram field. 0 v APRON F_ r w UQ 0 C 703.6.2 Finish and Contrast. Pictograms and their field shall have a non -glare finish. Pictograms shall contrast with their field with either a light pictogram on a dark field or a dark pictogram on a 0 Q 0 U a Lu Z light field. 308.2.1 Unobstructed. Where a forward reach is unobstructed, the high forward reach shall be 48" max and the low forward reach shall be 15" min above the finish floor or ground. O \ ~ ~ 0 Z w O - C/L 703.6.3 Text Descriptor. Pictograms shall have text descriptors located directly below the pictogram field. 308.2.2 Obstructed High Reach. Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth = a M =O � 0 Z Text descriptor shall comply with 703.2, 703.3 and 703.4. over the obstruction. The high forward reach shall be 48" max where the reach depth is 20" max. Where the reach depth exceeds 20", the high forward reach shall be 44" max and the CO a N N(D 0 M a OLu 703.7 Symbols of Accessibility. Symbols of accessibility shall comply with 703.7. reach depth shall n.25" max. U U Cl) LL U 0 l _ - - - J 703.7.1 Finish and Contrast. Symbols of accessibility and their background shall have anon -glare finish. Symbols of accessibility 308.3.1 Unobstructed. Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48" max and the low side 8 6 rn g shall contrast with their background with either a light symbol on a dark background or a dark symbol on a light background. FLOOR SPACE 48"MIN. CLEAR reach shall be 15" min above the finish floor or ground. F 308.3.2 Obstructed High Reach. Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall MIN FL be 34" max and the depth of the obstruction shall be 24" max. The high side reach shall be 48" max for a reach depth of 10" max. Where the reach depth exceeds 10", the high side reach B.O. HIGHEST shall be 46" max for a reach depth of 24" max. FIG 5 DRINKING FIG 6 DRINKING FIG 7 DRINKING TACTILE CHARACTER B.O. TACTILE _ B.O. TACTILE CHARACTER f - 60" MAX. A.F.F. exr FOUNTAIN SIDE FOUNTAIN FRONT FOUNTAIN PLAN CHARACTER E%* ROUTE '.r 48" MIN. & 60" B.O. LOWEST 48" MIN. & 60 MAX. A.F.F. _)e 5. * TACTILE CHARACTER 5" MAX. A.F.F. 20" ,20.25" 604 WATER CLOSETS 48" MIN. A.F.F.-ir- MAXa EXIT SIGN EXIT ROUTE SIGN B.O. TACTILE _ 604.2 Location. The water closet shall be positioned with a wall or partition to the rear and to one side. The centerline of the water closet shall be 16" min to 18" max from the side wall. Water CHARACTER closets shall be arranged for a left-hand or right-hand approach. 48" MIN. & 60" X 604.3.1 Size. Clearance around a water closet shall be 60" min measured perpendicular from the side wall and 56" min measured perpendicular from the rear wall. MAX. A.F.F. q 604.3.2 Overlap. The re uired clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, g�g �shelves, accessible routes, clear floorspace and clearances required at other fixtures, and the turning space. No otherfixtuss or obstructions shall be located within the required water closeto ro v f _ clearance./ B.O. TACTILE Ln 00 z v Z M M 604.4 Seats. The seat height of a water closet above the finish floor shall be 17" min and 19" max measured to the top of the seat. Seats shall not be sprung to return to a lifted position. / CHARACTER �� 604.5.1 Side Wall. The side wall grab bar shall be 42" long min, located 12" max from the rear wall and extending 54" min from the rear wall / 48" MIN. & 60" 10" 10" >10-24' 604.5.2 Rear Wall. The rear wall grab bar shall be 36" long min and extend from the centerline of the water closet 12" min on one side and 24" min on the other side. / MAX. A.F.F. MAX MAX MAX _ 604.6 Flush Controls. Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 309. Flush controls shall be located on the open side of the water closet EXIT 604.7 Dispensers. Toilet paper dispenses shall comply with 309.4 and shall be 7" min and 9" max in front of the water closet measured to the centerline of the dispenser. The outlet of the / 0) 0 TOILET ROOM SIGNAGE FIG. 308.2.1 UNOBSTRUCTED FIG. 308.2.2 OBSTRUCTED FIG. 308.3.1 UNOBSTRUCTED FIG. 308.3.2 OBSTRUCTED HIGH dispenser shall be 15" min and 48" max above the finish floor and shall not be located behind grab bars. Dispensers shall not be of a type that controls delivery or that does not allow / w w FORWARD REACH HIGH FORWARD REACH SIDE REACH SIDE REACH continuous paper flow. � � LL Lu LL / o ZOU Z=U 6„ 309 OPERABLE PARTS > LL w LL ,B" \ w O ) O B.O. TACTILE \\ m z U m U MIN. CHARACTER 309.2 Clear Floor Space. A clear floor or ground space complying with 305 shall be provided. \ 48" MIN. & 60" 309.3 Height. Operable parts shall be placed within one or more of the reach ranges specified in 308. J x 0 MAX. A.F.F. 309.4 Operation. Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5 \ \ Z Q ¢ Q F CLEAR FLOOR � m U � m U SPACE CENTERED Co Z P \\ O F S O F ON SIGN INTERNATIONAL ACCESSIBILITY pounds max. \ of L .._ - J SIGNAGE LL LL C/L 1: f 11W Z Bid Issue: 09/13/2019 Landlord Issue: 09/13/2019 Permit Issue: 09/13/2019 Construction Issue: T.B.D. 2010 ADA ACCESSIBILITY DETAILS Comm. Number 83-1189 Date 09/13/2019 Drawn By RFV Checked By RFV W I-_ C.0 Z o U CQC G W 0 'w'n vJ D G 00� W = Q Z O� 0� ~0 D U � cn 11W Z Bid Issue: 09/13/2019 Landlord Issue: 09/13/2019 Permit Issue: 09/13/2019 Construction Issue: T.B.D. 2010 ADA ACCESSIBILITY DETAILS Comm. Number 83-1189 Date 09/13/2019 Drawn By RFV Checked By RFV a. GENERAL REQUIREMENTS: SUMMARY OF WORK: THE WORK UNDER THIS CONTRACT INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS AND EQUIPMENT, FEES AND SERVICES TO PERFORM ALL WORK FOR THE CONSTRUCTION OF AN "COMCAST/XFINITY". THIS WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THESE DRAWINGS AND SPECIFICATIONS PREPARED BY "ARCHITECT". CONTRACTOR WILL PROVIDE ROUGH -IN, FINAL HOOK-UPS, HARDWIRING, LABOR AND MATERIALS AS REQUIRED FOR PROPER OPERATION IN ACCORDANCE WITH ALL LOCAL, STATE AND NATIONAL CODES AS WELL AS MANUFACTURER RECOMMENDATIONS TO MAINTAIN WARRANTIES. CONTRACTOR USE OF PREMISES A. PROTECT WORK, ADJACENT TO PROPERTY, PUBLIC UTILITIES AND THE PUBLIC. B. ASSUME RESPONSIBILITY FOR ANY DAMAGE OR INJURY DUE TO CONTRACTOR NEGLECT. C. MAINTAIN INSURANCE AGAINST CLAIMS UNDER WORKMEN'S COMPENSATION ACTS. D. MAINTAIN INSURANCE AGAINST CLAIMS FOR PERSONAL INJURY OR DEATH RELATED TO THIS CONTRACT. E. MAINTAIN BUILDER'S RISK INSURANCE ON WORK, FROM DAY CONSTRUCTION BEGINS TO PROJECT COMPLETION. F. KEEP PREMISES FREE FROM EXCESS WASTE MATERIAL AND DEBRIS. UPON COMPLETION OF PROJECT REMOVE ALL RUBBISH, TOOLS, EQUIPMENT AND SURPLUS MATERIALS. LEAVE BUILDING COMPLETELY CLEAN, INCLUDING FLOORS, WINDOWS, DOORS, FRAMES, CEILINGS AND ALL SURFACES. PRODUCTS AND SUBSTITUTIONS SUBSTITUTIONS: CONTRACTOR'S REQUESTS FOR CHANGES IN PRODUCTS, MATERIALS AND METHODS OF CONSTRUCTION REQUIRED BY CONTRACT DOCUMENTS ARE CONSIDERED REQUESTS FOR "SUBSTITUTIONS" AND ARE SUBJECT TO REQUIREMENTS HEREOF. SUBMITTALS: SUBMIT 3 COPIES, FULLY IDENTIFIED FOR PRODUCT OR METHOD BEING REPLACED BY SUBSTITUTION, INCLUDING RELATED SPECIFICATION SECTION AND DRAWING NUMBER(S) AND FULLY DOCUMENTED TO SHOW COMPLIANCE WITH REQUIREMENTS FOR SUBSTITUTIONS. PRODUCT DELIVERY -STORAGE -HANDLING: DELIVER, HANDLE AND STORE PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND BY METHODS AND MEANS WHICH WILL PREVENT DAMAGE, DETERIORATION AND LOSS INCLUDING THEFT. WARRANTIES (GUARANTEES): CATEGORIES OF SPECIFIC WARRANTIES: WARRANTIES ON THE WORK ARE IN SEVERAL CATEGORIES, INCLUDING (BUT NOT LIMITED TO) THE FOLLOWING SPECIFIC CATEGORIES RELATED TO INDIVIDUAL UNITS OF WORK SPECIFIED THROUGH OUT THESE SPECIFICATIONS. SPECIAL PRODUCT WARRANTY (GUARANTEE): A WARRANTY SPECIFICALLY WRITTEN AND SIGNED BY CONTRACTOR FOR A DEFINED PORTION OF THE WORK; AND WHERE REQUIRED, COUNTERSIGNED BY SUBCONTRACTOR. PROJECT CLOSE-OUT- RECORD DOCUMENTS A. UPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT TO THE OWNER THREE (3) COPIES OF EACH OF THE FOLLOWING: - SERVICE MANUALS COVERING THE MAINTENANCE AND OPERATION OF ALL EQUIPMENT. - GUARANTEE AND BONDS AS REQUIRED BY THE VARIOUS SECTION OF THE SPECIFICATIONS. B. THE SUBMITTAL DATA SHALL BE NEATLY BOUND IN ONE OR MORE VOLUMES PER SET, UTILIZING HARD BACK THREE RING BINDERS. C. ORGANIZATION OF THESE MANUALS SHALL BE NEAT AND ORDERLY FOR EASY REFERENCE. FINAL INSPECTION: A. WHEN THE WORK IS COMPLETE AND READY FOR FINAL INSPECTION THE CONTRACTOR SHALL SO NOTIFY THE OWNER AND LANDLORD WHO SHALL MAKE THE FINAL INSPECTION AND FURTHER NOTE ANY ITEMS TO BE FURNISHED, COMPLETED AND/OR CORRECTED. B. THE ARCHITECT SHALL BE NOTIFIED OF ALL ITEMS NOTED BY OWNER IMMEDIATELY AFTER INSPECTION. PRODUCT RECORD DOCUMENTS -QUALITY ASSURANCE ACCURACY OF RECORDS: THOROUGHLY COORDINATE CHANGES OF ORIGINAL CONTRACT DOCUMENTS WITHIN RECORD DOCUMENTS, MAKING ADEQUATE AND PROPER ENTRIES ON EACH PAGE OF DOCUMENTS WHERE SUCH ENTRY IS REQUIRED TO PROPERLY SHOW CHANGE. ACCURACY OF RECORDS SHALL BE SUCH THAT FUTURE SEARCH OF ITEMS IN CONTRACT DOCUMENTS MAY REASONABLY RELY ON INFORMATION OBTAINED FROM RECORD DOCUMENTS. PRODUCTS: MAINTAIN AT JOB SITE ONE RECORD COPY OF ALL DOCUMENTS COMPRISING CONTRACT DOCUMENTS. SUBMITTAL: UPON SUBSTANTIAL COMPLETION, SUBMIT TO "COMCAST/XFINITY" CONSTRUCTION DEPARTMENT QUALITY CONTROL A. STANDARDS: COMPLY WITH INDUSTRY STANDARDS EXCEPT WHEN MORE RESTRICTIVE TOLERANCES OR SPECIFIED REQUIREMENTS INDICATE MORE RIGID STANDARDS OR MORE PRECISE WORKMANSHIP. B. PERFORM ALL WORK TO MEET OR EXCEED THE REQUIREMENTS OF ALL APPLICABLE CODES, ORDINANCES, LAWS, REGULATIONS, SAFETY ORDERS, AND DIRECTIVES FROM AUTHORITIES HAVING JURISDICTION OVER THE WORKAS WELL AS LANDLORD CRITERIA AND RULES AND REGULATIONS OF THE MALL. C. PERFORM WORK WITH PERSONS QUALIFIED TO PRODUCE WORKMANSHIP OF SPECIFIED QUALITY. D. INSTALL PRODUCTS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONFLICT EXISTS BETWEEN MANUFACTURER'S RECOMMENDATIONS AND THE SPECIFIED REQUIREMENTS. NOTIFY THE ARCHITECT IMMEDIATELY. E. EXAMINATION PRIOR TO INSTALLATION: - PRIOR TO STARTING WORK, CAREFULLY INSPECT INSTALLED WORK OF OTHER TRADES AND VERIFY THAT SUCH WORK IS COMPLETE TO THE POINT WHERE WORK OF THIS SECTION MAY PROPERLY COMMENCE. NOTIFY THE ARCHITECT IN WRITING OF CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE WORK. - DO NOT BEGIN INSTALLATION UNTIL ALL UNSATISFACTORY CONDITIONS ARE RESOLVED. BEGINNING WORK CONSTITUTES ACCEPTANCE OF SITE CONDITIONS AND RESPONSIBILITY FOR DEFECTIVE INSTALLATION CAUSED BY PRIOR OBSERVABLE CONDITIONS. F. TESTING AND LABORATORY SERVICES. THE OWNER WILL ARRANGE FOR THE SERVICES OF AN INDEPENDENT TESTING LABORATORY TO INSPECT AND TEST THE WORK TO VERIFY COMPLIANCE WITH THE CONTRACT DOCUMENTS. REPORTS OF ALL INSPECTIONS AND TESTS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW CONTRACTOR'S RESPONSIBILITIES: a. COOPERATE WITH TESTING LABORATORY PERSONNEL, AND FURNISH ACCESS, TOOLS, SAMPLES, CERTIFICATIONS, TEST REPORTS, DESIGN MIXES, EQUIPMENT, STORAGE, AND ASSISTANCE AS REQUESTED BY THE TESTING LABORATORY. b. FOR OPERATIONS REQUIRING INSPECTION AND TESTING. WHEN TESTS OR INSPECTIONS CANNOT BE PERFORMED, THROUGH THE FAULT OF THE CONTRACTOR, REIMBURSE THE OWNER FOR THE ADDITIONAL COSTS INCURRED. c. REMOVE AND REPLACE ALL WORK FOUND NOT COMPLYING WITH THE CONTRACT DOCUMENTS. REMEDIES SHALL BE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND CODE REQUIREMENTS. d. IF INITIAL TESTS AND INSPECTIONS INDICATE DEFICIENT WORK, THE CONTRACTOR SHALL REIMBURSE THE OWNER FOR THE COSTS OF ALL SUBSEQUENT TESTS AND INSPECTIONS RELATED TO THE DEFICIENCY. e. ALL DAMAGE WHICH MAY OCCUR TO THE WORK AS A RESULT OF NORMAL TESTING OPERATIONS SHALL BE REPAIRED TO MATCH SURROUNDING SURFACES. f. SCHEDULE TESTING AND INSPECTION SO THAT THE WORK OF TESTING AND INSPECTION PERSONNEL WILL BE AS CONTINUOUS AND BRIEF AS POSSIBLE. TESTS AND INSPECTIONS SHALL BE IN ACCORDANCE WITH CODE REQUIREMENTS. SITE WORK: DEMOLITION -GENERAL: CONTRACTOR SHALL SURVEY THE EXISTING CONDITIONS OF THE SITE AND DEMOLISH, REMOVE AND LEGALLY DISPOSE OF MATERIALS SPECIFICALLY INDICATED TO BE REMOVED. ALL PRODUCTS INCLUDED IN THIS PROJECT SHALL BE NEW AND UNUSED. EXISTING TENANT ELECTRICAL SERVICE INCLUDING: FEEDERS, PANELS, BREAKERS, AND TRANSFORMERS TO EXTENT INDICATED ON CONTRACT DOCUMENTS. THE EXISTING MECHANICAL HVAC SYSTEM SHALL REMAIN TO THE MAXIMUM EXTENT POSSIBLE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. ARCHITECTURAL: METALS: LIGHTGAGE FRAMING: METAL STUDS SHALL BE USED IN WALLS AS SHOWN ON DRAWINGS (WALL FRAMING PLAN). STRUCTURAL PROPERTIES SHALL CONFORM TO AISI SPECIFICATIONS FOR THE DESIGN OF LIGHTGAGE COLD FORMED STRUCTURAL MEMBERS. WOOD & PLASTICS: ROUGH CARPENTRY: PRODUCT DELIVERY, STORAGE AND HANDLING. A. STORE LUMBER OFF GROUND OR FLOOR, COVER WITH WATERPROOF COVERING AND PROVIDE ADEQUATE VENTILATION. B. DO NOT STORE SEASONED OR TREATED LUMBER IN DAMP LOCATION. FINISH CARPENTRY AND MILLWORK: QUALITY ASSURANCE: LUMBER GRADING RULES AND WOOD SPACES: IN ACCORDANCE WITH PS 20. COMPLY WITH APPLICABLE "ARCHITECTURAL WOODWORK STANDARDS" BY AWL PRODUCTS; TELEPHONE DISPLAY UNITS -FIXTURES SUPPLIED AND INSTALLED BY; (SEE CONTRACT SCHEDULE). THERMAL AND MOISTURE PROTECTION: BUILDING INSULATION; SOUND BATT INSULATION MATERIALS: PROVIDE OWENS/CORNING 3 112" BATT ACOUSTICAL INSULATION IN ALL WALLS BETWEEN CUSTOMER AREAS AND STORAGE AREAS AND IN TENANT DEMISING PARTITIONS AS SHOWN ON DRAWINGS. (WHEN SPECIFIED) EXECUTION: APPLICATION: INSTALL BATT INSULATION IN ACCORDANCE WITH MFG RECOMMENDATIONS JOINT SEALANTS: PRODUCT DELIVERY, STORAGE AND HANDLING: DELIVER MATERIALS TO SITE IN MFG ORIGINAL, UNOPENED CONTAINERS WITH LABEL INTACT AND LEGIBLE. PRODUCTS -MATERIALS: A. SEALANT: 1. BETWEEN STEEL AND CONCRETE OR BETWEEN ALUMINUM AND CONCRETE. 2. FOR INTERIOR JOINTS BETWEEN MASONRY AND OTHER MATERIALS: ACRYLIC LATEX CAULK, COLOR AS SELECTED BY ARCHITECT. APPLICATION: FOLLOW MFG INSTRUCTION REGARDING SURFACE PREPARATION, PRIMING APPLICATION LIFE AND APPLICATION PROCEDURE. CONSULT SEALANT MFG FOR RECOMMENDATION FOR APPLICATION OF SEALANT WHEN AIR TEMP IS BELOW 40 DEGREES F. DOORS AND WINDOWS: REFER TO DRAWINGS FOR LABELED DOORS AND/OR FRAMES REQUIRED. MATERIALS: A. HOLLOW METAL FRAMES: 1. FABRICATE FROM 16 GA COLD -ROLLED STEEL WITH WELDED CORNERS, GROUND SMOOTH. 2. DEPTH: AS REQUIRED FOR EACH INDIVIDUAL INSTALLATION. 3. FURNISH WITH 3 ANCHORS PER JAMB AND REMOVABLE SPREADER AT BOTTOM. 4. FINISH: FACTORY BAKED -ON PRIMER. WOOD DOORS: FURNISH DOORS WITH UL LABELS ATTACHED, SHOWING RATING, MFG AND LABELED HARDWARE REQUIREMENTS. HARDWARE: INCLUDE EACH ITEM TO BE FURNISHED; SHOW MFG'S CATALOG NUMBERS, FINISH, ACCESSORY ITEMS, KEYING AND LOCATION BY DOOR NUMBER IN ACCORDANCE WITH SCHEDULE INDICATED ON DRAWINGS. KEYING: ALL LOCKSETS AND CYLINDER LOCKS SHALL BE KEYED AND MASTER KEYED. VERIFY KEYING REQUIREMENTS WITH COMCAST REGION MANAGER. STANDARD QUALITY: REFER TO HARDWARE SCHEDULE ON DRAWINGS. EXECUTION -INSTALLATION: INSTALL IN ACCORDANCE WITH MFG'S DIRECTIONS, USING TEMPLATES FURNISHED BY MANUFACTURER WHERE APPLICABLE. GLAZING: FURNISH GLAZING MATERIALS IN ACCORDANCE WITH CPSC STANDARD NO. 16 CFR PART 1201, "ARCHITECTURAL SAFETY GLAZING STANDARD". MIRRORS: FS DD -G-451 MIRROR QUALITY FLOAT GLASS WITH TWO COATS SILVER AND ELECTROPLATED COPPER BACKING, GROUND AND POLISHED EDGES. A. MIRRORS: MOUNT ON WALL WITH EDGE CLIP AND GLAZING TAPE. B. INSTALL GLASS IN ACCORDANCE WITH FLAT GLASS JOBBER'S GLAZING MANUAL. USE WORKMEN SPECIALIZED IN INSTALLATION OF GLASS AND SEALANTS. FINISHES: GYPSUM DRYWALL: PRODUCT DELIVERY, STORAGE AND HANDLING: STORE MATERIALS IN PROTECTED, DRY AREA UNTIL USED. PRODUCTS -MATERIALS: A. GYPSUM BOARD: ASTM A36, TYPE X 518 FIRECODE, GOLD BOND, U.S.G. OR AN APPROVED EQUAL WHERE SHOWN ON DRAWINGS. B. TRIM: PROVIDE MFG'S STANDARD METAL TRIM ACCESSORIES OF BEADED TYPE WITH FACE FLANGES FOR CONCEALMENT IN JOINT COMPOUND EXCEPT WHERE SEMI -FINISHING OR EXPOSED TYPE IS INDICATED. C. JOINT TAPE: ASTM C 475 PERFORATED. D. JOINT COMPOUND: ASTM C 475 OF THE TYPE INDICATED. TILE PRODUCT DELIVERY, STORAGE AND HANDLING: DELIVER MATERIALS IN MFG'S ORIGINAL UNOPENED CONTAINERS,WITH IDENTIFYING LABELS INTACT AND LEGIBLE. JOB CONDITIONS: MAINTAIN MIN. 50 DEGREES F. TEMP. IN AREAS RECEIVING AND FOR MIN. 7 DAYS AFTER INSTALLATION. PRODUCTS -MATERIALS: SEE FINISH LEGEND FOR STYLE AND COLOR ACOUSTICAL CEILINGS: JOB CONDITIONS: DO NOT INSTALL CEILINGS UNTIL BUILDING IS SUBSTANTIALLY WATER WEATHER TIGHT AND UNTIL OVERHEAD MECHANICAL AND ELECTRICAL WORK HAS BEEN INSPECTED AND APPROVED. PRODUCTS -MATERIALS: REFER TO REFLECTED CEILING PLAN FOR GRID AND TILE TYPES. EXECUTION -INSTALLATION: A. VERIFY LIGHTING FIXTURE AND AIR DISTRIBUTION LAYOUT TO ASSURE POSITIONING WITHIN FINISHED CEILING. B. FOLLOW APPLICABLE REQUIREMENTS OF REQUIREMENTS OF ASTM C636 AND RECOMMENDATIONS OF CEILING AND INTERIOR SYSTEM CONTRACTORS ASSOC. C. SPACE 12 GA. HANGER WIRES NOT OVER 4'-0" O.C.; PROPERLY LEVEL AND ALIGN MAIN AND CROSS MEMBERS, ATTACH WALL ANGLE MAX. 24" O.C. D. CHECK FOR FINAL LEVELING AND CENTERING OF PANELS. E. REPLACE DAMAGED OR SOILED PANELS. FLOOR COVERINGS: JOB CONDITIONS: MAINTAIN TEMPERATURE IN SPACES TO RECEIVE TILE BETWEEN 70 DEGREES AND 90 DEGREES F. FOR 48 HOURS PRIOR TO, DURING AND FOR 48 HOURS AFTER INSTALLATION. PRODUCTS -MATERIALS: A. CARPET: AS SUPPLIED AND INSTALLED BY CONTRACTOR, GLUE DOWN APPLICATION. B. VINYL COVE BASE: STANDARD COLORS AND SIZE AS INDICATED ON FINISH SCHEDULE. 1. BASE TILE AREAS: COVED 2. PROVIDE PRE -MOLDED SHAPES FOR INSIDE AND OUTSIDE CORNERS. C. ADHESIVE: AS RECOMMENDED BY TILE, BASE OR CARPET MANUFACTURER. PAINTING JOB CONDITIONS: A. CAREFULLY AND ADEQUATELY PROTECT, AS REQUIRED, SURFACES NOT REQUIRING PAINTING IN AREAS WHERE PAINTING IS BEING CARRIED ON. B. APPLY PAINT UNDER DRY AND DUST -FREE CONDITIONS. C. DO NOT APPLY PAINT WHEN TEMPERATURE IS LESS THAN 50 DEGREES F. OR MORE THAN 90 DEGREES F. OR WHEN EXCESSIVELY HUMID. D. ALL PAINTED SURFACES ARE TO RECEIVE A MINIMUM OF (1) PRIMER COAT AND (2) FINISH COATS. E. ALL PAINT IS TO BE APPLIED WITH BRUSH & ROLLER. NO SPRAYING. PRODUCTS -MATERIALS: A. PAINTS: APPROVED COLORS SHALL BE AS SCHEDULED ON THE DRAWINGS OR SELECTED BY "COMCAST/XFINITY. B. GYPSUM BOARD TREATMENT: U.S.G. GYPSUM CO. "PERF -A -TAPE", "READY MIXED ALL-PURPOSE JOINT COMPOUND" AND "ALL PURPOSE TEXTURE FINISH" OR EQUAL. APPLICATION: A. APPLY PAINT UNIFORMLY WITHOUT VISIBLE LAPS, SAGS, CURTAINS, HOLIDAYS OR OBJECTIONAL BRUSH MARKS. B. INSURE THAT PRIMER AND INTERMEDIATE COATS OF PAINT ARE UNSCARRED AND COMPLETELY INTEGRAL AT THE TIME OF APPLICATION OF EACH COAT. ALLOW SUFFICIENT TIME BETWEEN COATS TO ENSURE PROPER DRYING. SPECIALTIES: IDENTIFYING DEVICES: A. PROVIDE SIGNAGE AS REQUIRED AND AS SPECIFIED ON DRAWINGS. B. INSTALL SIGNS AS REQUIRED BY ALL GOVERNING CODES AND MOUNT AT REQUIRED CODE HEIGHTS. FIRE EXTINGUISHERS, CABINETS AND ACCESSORIES: CABINETS AND EXTINGUISHERS SHALL MEET ALL REQUIREMENTS OF GOVERNING CODES. ACCEPTABLE MANUFACTURERS: POTTER-ROEMER, INC. OR LARSEN'S MFG COMPANY FIRE EXTINGUISHER: 2A-20BC CAPACITY: 5lbs./10 Ibs./201bs. SIZE AND LOCATION AS REQUIRED BY LOCAL CODES. SEE ELECTRICAL AND MECHANICAL DRAWINGS FOR ELECTRICAL AND MECHANICAL SPECIFICATIONS LL W Z W U W U_ ''W^ W L.L.. CW G 0 Z) U W i--1 r) C O 4� Q U U) W N 0 C� G Nq ^ Cn 0 0T(Y- Z 01-- I. Z) Q0 Bid Issue: Landlord Issue: Permit Issue: Construction Issue: 09/13/2019 09/13/2019 09/13/2019 T.B.D. SPECIFICATIONS AND RESPONSIBILITY SCHEDULE Comm. Number 83-1189 Date 09/13/2019 Drawn By RFV Checked By RFV A0.3 I I DEMOLITION PLAN KEY NOTES DEMOLITION NOTES EXISTING EXTERIOR WALL TO REMAIN. PREPARE FOR NEW FINISHES. 1. 1 DRAWINGS OF EXISTING CONDITIONS HAVE BEEN COMPILED FROM EXISTING DATA SUPPLIED BY THE OWNER TO THE ARCHITECT. THE ARCHITECT MAKES NO WARRANTY, EITHER EXPRESSED OR IMPLIED, FOR THE ACCURACY OF THE COMPLETENESS OF THE EXISTING O/-+ INFORMATION RECORDED. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS THAT MIGHT ARISE IN THE COURSE OF THE DEMOLITION WORK. WALL DEMOLITION LEGEND O EXISTING STOREFRONT GLAZING SYSTEM TOREMAIN (V.I.F.)CLEAN TO'LIKE NEW EXTERIOR ELEVATION 51A4.0 FOR ADDITIONAL WINDOWS. 2. VERIFY LOCATIONS OF EXISTING MECHANICAL, PLUMBING AND ELECTRICAL UTILITIES. LOCATE AND PROTECT UTILITIES TO REMAIN. DISCONNECT, REMOVE BACK TO NEAREST JUNCTION BOX OR PANEL, AS REQUIRED, AND CAP DESIGNATED UTILITIES WITHIN THE V _ CONDITION. (7YP.) -SEE DEMOLITION AREA. REFER TO THE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFO. V - - - _ -I MATERIAL TO BE DEMOLISHED - - O EXISTING STOREFRONT ENTRY DOOR TO OIES WITH (ARIA REQUIREMENTS, TOA'LIKE AND W' COS DITION 3. EXISTING ELECTRICAL AND TELEPHONE OUTLETS LOCATED ON DEMOLISHED WALLS ARE TO BE REMOVED INCLUDING CONDUIT AND WIRING BACK TO JUNCTION BOX. LOCATIONS ARE TO BE PATCHED AND REPAIRED TO BE FLUSH WITH ADJACENT WALL SURFACE. ARC HITS{ T EXISTING WALL TO REMAIN G.C. SHALL ENSU. AR.. . . . :11 . . . , LOCAL, STATE, AND NATIONAL CODES FOR ACCESSIBILITY. 4. WHERE PLUMBING FIXTURES ARE BEING REMOVED OR WHERE EXPOSED PLUMBING PIPES OCCUR, CAP LINES BEHIND FINISHED SURFACES. PATCH AND REPAIR AS REQUIRED. OEXISTING INTERIOR WALL TO REMAIN. PREPARE FOR NEW FINISHES. 5. ALL EXISTING CONSTRUCTION WHERE INDICATED INCLUDING ELECTRICAL, TELEPHONE, PLUMBING AND MECHANICAL DEVICES NOT OTHERWISE INDICATED ON THESE CONSTRUCTION DRAWINGS SHALL BE REMOVED IN A CAREFUL MANNER SO AS NOT TO DAMAGE O5 EXISTING CEILING FINISHES AND LIGHT FIXTURES TO REMAIN. CLEAN CEILING GRID & ADJOINING CONSTRUCTION. EXISTING FIXTURES, REPLACE DAMAGED OR SOILED CEILING TILES. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR 55 S 5T S R _�T 11 STE. 750 / ADJACENT AREA / , REMOVE EXISTING FLOORING FINISHES AND WALL BASES AND PREP FOR NEW FINISHES. OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF HIS WORK. NNE _ ON DURING CONSTRUCTION. PROVIDE REROUTING OF UTILITIES SERVING ADJACENT AREAS THAT ARE TO MAINTAIN UNINTERRUPTED SERVICE. ANY TEMPORARY SUSPENSION OF SERVICE SHALL BE _ 651. 222.41642 2.A 42 F 6 1 T 2 3 01 ' EXISTING DISPLAYS TO BE REMOVE I 7. ALL EXISTING BUILDING UTILITIES SHALL REMAIN IN OPERATION 7 G D SPLA D (V.I.F.). COORDINATED AND APPROVED BY THE FACILITY MANAGER, NOT LESS THAN 24 -HOURS IN ADVANCE. GEXISTING COUNTER TO BE REMOVED (V.I.F.) 8. THE CONTRACTOR WILL VERIFY AND CONFORM TO ALL REQUIREMENTS OF ALL UTILITY COMPANIES UNLESS OTHERWISE NOTED IN THE PLANS AND SPECIFICATIONS. EXISTING �9 REMOVE EXISTING DOOR. 3 9. THE DEMOLITION PLAN KEYNOTES ARE DIAGRAMMATIC AND GENERAL IN NATURE. THE INTENT IS TO ILLUSTRATE THE COMPLETE DEMOLITION OF THE SPACES INDICATED UNLESS NOTED OTHERWISE. FIELD VERIFICATION OF THE EXISTING CONDITIONS AND SPECIFIC VESTIBULE 4 QUANTITIES IS THE RESPONSIBILITY OF THE CONTRACTOR. 10 EXISTING DOORS &HARDWARE TO REMAIN. 100 10. REMOVAL AND DISPOSAL OF DEMOLITION DEBRIS IS THE RESPONSIBILITY OF THE CONTRACTOR. VERIFY THE HAULING ROUTE THROUGH THE BUILDING, THE DEMOLITION STAGING AREA, AND THE LOCATION OF THE DUMPSTERS WITH THE OWNER PRIOR TO THE START / 11 EXISTING VESTIBULE DOOR & GLAZING TO REMAIN - CLEAN TO "LIKE NEW" CONDITION. OF DEMOLITION. DISPOSAL OF RUBBISH SHALL BE DONE IN A LEGAL MANNER. / i 9 11 5 7 12 REMOVE EXISTING INTERIOR WINDOW. 11. THE OWNER RESERVES THE RIGHT TO SALVAGE ANY DEMOLISHED ITEM. VERIFY ITEMS TO BE SALVAGED WITH THE OWNER PRIOR TO THE START OF DEMOLITION. REMOVE, PROTECT, CLEAN, REPAIR FOR THE REUSE AND TURN OVER SUCH ITEMS AS DIRECTED BY THE 2 OWNER. j i 12. IN ORDER TO INSTALL SOME OF THE NEW WORK INCLUDING, BUT NOT LIMITED TO MECHANICAL, PLUMBING OR ELECTRICAL) IT WILL BE NECESSARY FOR THE CONTRACTOR AND HIS SUBCONTRACTORS TO REMOVE AND REPLACE (OR REFINISH) EXISTING WALLS, v�g� i 4 FLOORS, OR CEILING IN THE AREAS OF THE BUILDING NOT SHOWN ON THESE PLANS. THE CONTRACTOR SHALL INCLUDE ALL RELATED COSTS IN HIS BASE BID, WHETHER SHOWN ON THESE PLANS OR NOT. �G,Z -RRyy 1Ng§ 1 Y 13. PROTECT ADJACENT SPACES NOT SCHEDULED FOR DEMOLITION. PATCH AND REPAIR DAMAGED FINISHES, ITEMS AND FIXTURES TO REMAIN AND/OR REPLACE IN KIND TO MATCH EXISTING FROM DAMAGE DURING THE PROGRESS OF THE WORK. PROVIDE TEMPORARY y foE� SAFETY BARRIERS REQUIRED BY CODE AND AS INDICATED TO INSURE PUBLIC SAFETY AND TO ALLOW BUILDING OCCUPANCY. CONTRACTOR TO SUBMIT FOR APPROVAL, BARRIER LOCATIONS, AND METHOD OF CONSTRUCTION TO THE ARCHITECT PRIOR TO e `z -<-'-; fi i INSTALLATION. S AU ; 2 14. NO STRUCTURAL ELEMENTS ARE INCLUDED IN THIS SCOPE OF WORK. / 15. PROVIDE DUST BARRIERS AROUND OPENINGS, TO AND FROM THE CONSTRUCTION AREA. PROVIDE ALL MEANS NECESSARY TO INHIBIT DUST FROM ENTERING OTHER PORTIONS OF THE FACILITY. SUBMIT BARRIER LOCATIONS TO THE ARCHITECT FOR APPROVAL, PRIOR qtx Gr TO INSTALLATION. 4 16. PROVIDE ADEQUATE SHORING, BRACING, BARRICADES AND PROTECTIVE MEASURES AS REQUIRED TO SAFELY EXECUTE THE WORK IN THE CONSTRUCTION AREA AND THE AREAS ADJACENT TO THE CONSTRUCTION AREA. CEASE OPERATIONS AND NOTIFY THE HATCHED AREA ARCHITECT IMMEDIATELY IF THE STRUCTURE APPEARS TO BE ENDANGERED. DO NOT RESUME OPERATIONS UNTIL CORRECTIVE MEASURES HAVE BEEN TAKEN. INDICATES RETAIL EXISTING TO ' " 17. CONTRACTOR SHALL MAINTAIN REQUIRED MEANS OF EGRESS AND ENSURE THAT EXIT ROUTES ARE SIGNED, LIGHTED AND PROTECTED IN ACCORDANCE WITH CODE REQUIREMENTS. RELOCATE EXISTING AND/OR PROVIDE SMOKE PROTECTORS AND LIFE SAFETY i 101 EQUIPMENT FOR ADEQUATE COVERAGE. REMAIN. NO WORK IN THESE , 1 i j AREAS 18. PROVIDE TEMPORARY NON-COMBUSTIBLE CONSTRUCTION BARRIERS WHERE REQUIRED BY CODE AND THE GOVERNING FIRE AUTHORITY. MINIMUM REQUIREMENTS: GHT WALL OM FLOOR B. STUDS AA. FULL IT 24" O C., WITH H 5 8' TYPE "OX CEILING. BOARD. ADJACENT AREA N.LC,! C. NON-COMBUSTIBLE ACCESS DOOR WITH (3) HINGES AND SPRING CLOSER. � 19. SURVEY EXISTING FLOORS AND CLEARLY MARK ON FLOOR SURFACE THE LOCATIONS OF ALL BEAMS AND JOISTS. MARK ALL CORE DRILL PENETRATIONS OR SAW CUT LOCATIONS AND RECEIVE STRUCTURAL ENGINEER'S APPROVAL PRIOR TO DRILLING CONCRETE. --------- -- --------------------------- -- - ' g 20. C RIGID MATERIALS USING MASONRY SAW OR CORE DRILL. PNEUMATIC TOOLS ARE NOT ALLOWED WITHOUT PRIOR APPROVAL. UT ------------- 22. ---- --- ------------ ---- 21. ALL CORE DRILLING, SAW CUTTING OR OTHER NOISY WORK SHALL BE SCHEDULED 48 -HOURS IN ADVANCE WITH THE OWNER. i , 2 22. APPLY CEMENT BASE FLOOR PATCH AS REQUIRED TO FILL DINGS, NAIL HOLES, CHIPS AND CRACKS. 23. AT FLOOR AREAS SCHEDULED TO RECEIVE NEW FLOOR COVERING, REMOVE EXISTING FLOOR COVERING AND PREPARE SUBSTRATE FOR NEW FLOOR COVERING PER SPECIFICATIONS AND MANUFACTURER'S REQUIREMENTS. 24. AT ABANDONED PENETRATIONS OF FIRE RATED WALLS, CEILING OR FLOOR CONSTRUCTION, COMPLETELY SEAL VOIDS WITH FIRE RATED MATERIAL TO FULL THICKNESS OF THE PENETRATED ELEMENT. ALL PATCHING OF EXISTING WORK TO REMAIN SHALL MATCH 4 FINISH PER SCHEDULE OR WHERE UNSCHEDULED TO MATCH EXISTING FINISHES TO REMAIN, AND SHALL MEET OR EXCEED FIRE RATING INDICATED ON FLOOR PLAN AND AS REQUIRED BY THE FIRE/LIFE SAFETY INSPECTOR. 10 10 1 25. COORDINATE EXISTING SPRINKLER LINE AND HEAD LOCATION WITH NEW PLAN. SUBMIT SPRINKLER SHOP DRAWINGS TO ARCHITECT FOR REVIEW WITH THE CITY FIRE DEPARTMENT. 4 26. CONTRACTOR IS RESPONSIBLE FOR BUILDING SECURITY DURING DEMOLITION PHASE. PROTECT ALL OPENINGS FROM WEATHER CONDITIONS AND SECURE THEM TO PREVENT VANDALISM. To', 4 27. DO NOT PERFORM ANY WORK THAT WILL VOID WARRANTIES OF EXISTING WEATHER EXPOSED OR MOISTURE RESISTANT ELEMENTS WITHOUT PRIOR APPROVAL FROM THE OWNER. 28. ARCHITECT ASSUMES NO RESPONSIBILITY RELATING TO ANY TOXIC MATERIALS, INCLUDING ASBESTOS, AND ASSUMES NO RESPONSIBILITY TO ITS EXISTENCE OR REMOVAL. THE OWNER WILL TAKE ACTION FOR DIRECTLY CONTRACTING WITH A CONSULTANT OR i ADJACENT AREA ' i 2 SPECIALIST, LICENSED BY THE STATE, FOR SUCH SERVICES SHOULD THOSE SERVICES BE REQUIRED ON THE PROJECT. W (D 29. IF THE EXISTING BUILDING CONSTRUCTION IS CLASSIFIED SUCH THAT FIREPROOFING INSULATION IS PRESENT, THEN THE CONTRACTOR, PRIOR TO STARTING ANY WORK, SHALL VERIFY THE CURRENT FIRE -RESISTANCE RATING(S) OF THE EXISTING BUILDING z N ELEMENT(S). IF THE EXISTING FIREPROOFING INSULATION IS DAMAGED/AFFECTED DURING THE COURSE OF THE WORK, AS DEFINED BY THIS PROJECT SCOPE, THEN THE CONTRACTOR SHALL PATCH/ REPAIR THE FIREPROOFING INSULATION TO A CONDITION THAT 7 N E SHALL MATCH OR EXCEED THE ORIGINAL FIRE -RESISTANCE RATING(S) OF THE EXISTING BUILDING ELEMENT(S) W DEMOLITION PLAN N g 30. CONTRACTOR TO RELOCATE AND REUSE EXISTING DOORS AND HARDWARE WHERE POSSIBLE. W 1 � U C G W 31: EXISTING DOORS TO REMAIN U.N.O. rW, ^ U TRENCHING PLAN KEY NOTES W Uj O ODASHED LINE INDICATES SAW CUT TRENCH FOR ELECTRICAL V / D 2 CONDUIT RUNS - SEE NOTES (THIS SHEET) FOR ADDITIONAL INFORMATION. N L.L GEXISTING DOOR & HARDWARE TO REMAIN (V.I.F.). W 2 3 2i z OEXISTING STOREFRONT ENTRY AND VESTIBULE DOOR(S)TO REMAIN (V.I.F.) CLEAN TO ALIKE NEW " CONDITION. G.C. O SHALL ENSURE THRESHOLD COMPLIES WITH ADA NATIONAL4CODES FOR ACCESSIBILITY. IL L, STATE AND (n ADJACENT -AREA N.LC. U r U) TRENCHING PLAN GENERAL NOTES ' EXISTING I 3 BE / I VESTIBULE A AS PENETRATION PEER CONDITION ON CENTERLINE OF WALL OR 4_1 i 100 �� � B. REFER TO FFE PLAN FOR CRITICAL HOLD DIMENSIONS BETWEEN FIXTURES. C. VERIFY FINAL FIXTURE AND PENETRATION LOCATIONS IN FIELD PRIOR TO SAW CUTTING AND INSTALLATION OF OUTLETS (TYP.) u RETAIL ' 101 3 D. GENERAL CONTRACTOR TO BE RESPONSIBLE FOR SAW CUTTING OF CHANNEL IN EXISTING CONCRETE SLAB FOR O RUNNING OF TELECOMMUNICATIONS AND ELECTRICAL � / CONDUITS. REFILL SAW CUT WITH 3,000 PSI CONCRETE WHEN FINISHED. U U) 4 `ro 10'-5' M in � 1 3 i A1.0 _ HATCHED AREA i�INDICATES i- i EXISTING TO REMAIN. NO'/,/ NOTE: COORDINATE ALL SAW CUTTING AND WORK IN THESE AREAS - REP. PRIOR TO CONSTRUCTION START. CONCRETE SLAB ON GRADES MATCH DEPTH OF CORE DRILLING WITH LANDLORD'S ON SITE i EXISTING (V.I.F.) WITH #3 BARS AT 16" O.C. EACH WAY AT MIDDLE DEPTH OF SLAB. DRILL AND ADJACENT AREA / EPDXY 6" INTO EXISTING SLAB i SAW CUT AND Bid Issue: 09/13/2019 REMOVE EXISTING LOCATE CONDUIT ABOVE VAPOR BARRIER Landlord Issue: 09/13/2019 E 1 SLAB FOR TRENCH AS i REQUIRED VAPOR BARRIER TO MATCH EXISTING - Permit Issue: 09/13/2019 ? ��' C J SEALED TO EXISTING V.B. TO MAINTAIN / - EXISTING SLAB ON INTEGRITY OF V.B. Construction Issue: T.B.D. - o GRADE AS OCCURS - COMPACTED FILL AS REQUIRED 4 A1.0 ° a . DEMOLITION 4'-1 112' TYR PLAN & y / /,� /,� TRENCHING ' LAN �s P a �. v. Comm, Number $3-1189 ' iADJACENT AREA . EXIST. CONC. SLAB 1'-0" EXIST. CONC. SLAB Date 09/13/2019 / N.I.C. 34" MAX, Drawn By RFV Checked By RFV E 3 TRENCHING DETAIL 2 TRENCHING PLAN N S 1.� 1/4' -1'-0• A1.� 1112' -1'-0' A1,0 W FINISH MATERIAL LEGEND MARK ITEM MANUFACTURER SPECIFICATION & COLOR COMMENT CEILING MATERIAL XFINITY Internet Wall Small EXISTING Bench -Gra FN -03A 5 Eiffel Chair -Gray FX -04 1 CEILING TO FX -12A 2 Freestanding Transaction Station - 42 in. XR-128 11 ADA POS Table REAMAIN 1 3' - 0" T- 0" WALL FINISHES PTA PAINT Company: Benjamin Moore Product: Paint Location: Retail Walls PT -1 B2 Contact: Customer Service Color: Coventry Gray -HC -169 -- Phone: 866.708.9181 Finish: Satin Email: Web: www.benjaminmoore.com Company: Johnsonite Product: Mandalay: MW -69-H3 Location: F.O.H. WB -3 WALL BASE Contact: Color: #69-StedingSilver Phone: 800.899.8916 Thickness: 3/8' Email: Dimensions: 3" Height Web: www.'ohnsonite.com FLOORING LVT-1 VINYL Company: Armstrong Flooring Product: ID70 Location: F.O.H. COMPOSITION Contact: Dennis Scott Color: Antik Oak Beige 24201001 TILE Phone: 972.841.2951 Tread: Email: dlscott@armstrongflooring.com Dimensions: 7.87" x 48" Web: Thickness: .098" Installation: TS -2 TRANSITION Company: Johnsonite Product: Reducer Location: F.O.H. Entry Contact: Model: CRS -40-B STRIP Phone: 800.899.8916 Dimensions: 318" to 0", 11/2" width Email: Color: 40 - Black Web: www.johnsonite.com WMA WALK OFF Company: Mats Inc. Product: Berkshire Synthetic Cocoa Mat Location: Entry MAT Contact: Color: Charcoal Phone: 800.628.7462 Dimensions: 5'-0' X 8'-71/2" V.I.F. Email Thickness: Web: www.matsinc.com Installation: Glue Down EQ -1200 Il Express Pay Kiosk CX -01 11 Equipment Storage (Small CX -046 1 XFINITYXI Information Wall Small CX -04C 1 XFINITY Internet Wall Small FN -01A 1 Bench -Gra FN -03A 5 Eiffel Chair -Gray FX -04 1 Device Table FX -12A 2 Freestanding Transaction Station - 42 in. XR-128 11 ADA POS Table RETAIL TO BOH 1 3' - 0" T- 0" 13/4" A DOOR SCHEDULE MARK ROOM COUNT WIDTH HEIGHT THICKNESS TYPE DOOR MATERIAL DOOR FINISH FRAME TYPE FRAME MATERIAL FRAME FINISH HARDWARE GROUP FIRE RATING CARD READER COMMENTS 101 RETAIL TO BOH 1 3' - 0" T- 0" 13/4" A SOLID CORE WD PT -1 1 HM PT -1 B2 0 Y -- DOOR GENERAL NOTES A. REFER TO THE PARTITION PLAN AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. B. ALL DOORS AND FRAMES TO BE PAINTED WITH SEMI -GLOSS PAINT TO MATCH ADJACENT WALL COLOR. C. ALL CARD READERS WILL BE PROVIDED AND INSTALLED BY COMCAST SECURITY VENDOR. D. ALL CARD READERS TO BE FAIL SAFE AND TO BE TIED INTO FIRE ALARM SYSTEM. E. PROVIDE A SIGN ON OR NEAR THE MAIN EXIT DOOR READING: "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED". F. DOOR HANDLES, PULLS OR KNOBS SHALL BE INSTALLED AT 40" ABOVE FINISH FLOOR. ALL OTHER OPERABLE PARTS OF DOOR HARDWARE (SUCH AS DEADBOLTS, KEYHOLES... ETC) ARE TO BE CENTERED BETWEEN 34" AND 44" ABOVE FINISH FLOOR. IF EXISTING BUILDING STANDARD EXISTS, MATCH BUILDING STANDARD AND CONFIRM COMPLIANCE WITH ACCESSIBILITY REQUIREMENTS. G. MAXIMUM UNDERCUT OF ALL DOORS NOT IN A RATED CORRIDOR SHALL NOT EXCEED 1/2" ABOVE FINISH FLOOR SURFACE. H. ALL DOORS TO BE OPERABLE FROM THE INSIDE WITHOUT A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. I. ALL REQUIRED FIRE DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY SHOWING THE SPECIFIC RATING. J. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. K. COORDINATE CARD READER INSTALLATION REQUIREMENTS WITH COMCAST SECURITY VENDOR HARDWARE GROUPS SINGLE WOOD OR HOLLOW METAL DOOR B2 INTERIOR DOOR WITH CARD READER BUTT HINGES 450 T88 STOP W1276CCS CLOSER 8581 BF LATCH GUARD LP2 CLASS ROOM LOCK ND 80 PD - SCHLAGE "ND" SERIES LATCH -#626 SATIN CHROME ELECTRIC STRIKE ADAMS RITE 7400 SERIES 12" STAINLESS STEEL KICKPLATE B6 INTERIOR DOOR WITHOUT CARD READER BUTT HINGES 450 T88 STOP W1276 CCS CLOSER 8581 BF PASSAGE LOCK ND 10 S - SCHLAGE "ND' SERIES LATCH -#626 SATIN CHROME 12" STAINLESS STEEL KICKPLATE DOOR TYPES SOLID CORE WOOD DOOR W/ SOLID HARDWARE EDGES - SPECIES TO MATCH FACE VENEER - SEE DOOR SCHED. FOR FINISH TYPE A DR. 101 FRAME TYPES HOLLOW METAL DOOR FRAME - SEE DOOR SCHED. FOR FINISH ®rm AMUWftl 114' - T-0' E N S 7F7 W CLEAR FLOOR SPACES: CLEAR FLOOR SPACE DIMENSIONS ARE FROM FACE OF FINAL FINISH MATERIAL WHICH INCLUDES ANY PROJECTING FINISHES SUCH AS: CASING, FLOOR BASE MATERIAL, CORNER GUARDS, ETC. BEYOND THE FINISH WALL. VERIFY WALL TYPES AND WALL FINISHES TO MAINTAIN PROPER CLEARANCES DOOR CLEARANCES: THE DASHED RECTANGLES AT DOORS INDICATE CLEAR FLOOR SPACE NEEDED FORA HANDICAPPED PERSON TO MANEUVER. NO OBJECTS (WALLS, FIXTURES, ETC.) ARE TO BE PLACED WITHIN THE DASHED RECTANGLES. SEE SHEET AO.2 FOR ADDITIONAL INFORMATION. EXIT PATH & FIXTURE CLEARANCES: A MAIN ACCESS AISLE, 44" WIDE SHALL BE PROVIDED FROM STOREFRONT ENTRY DOORS TO SECOND EXIT DOOR. THE MINIMUM WIDTH OF DISPLAY AISLE SHALL BE 36". 4 tArIll 9 0 11/2' -1"-0' G.C. TO COORDINATE WITH C.P.M. TO OBTAIN DRILL TEMPLATE FROM REGION MANAGER FOR EXPRESS PAY KIOSKS, THIS SIDE FLUSH AGAINST WALL BASE TEMPLATE FOR KIOSK ANCHOR LOCATIONS NTER TEMPLATE ON PAY KIOSK �S PAY KIOSK DRILL GENERAL NOTES A. VERIFY DIMENSION WITH MILLWORKER PRIOR TO FRAMING. B. UNLESS OTHERWISE NOTED OR INDICATED, ALL DIMENSIONS ON THESE DOCUMENTS SHALL BE TO FACE OF CURB, FACE OF CONCRETE OR MASONRY, FACE OF GYPSUM BOARD OR CENTERLINE OF GRIDS. C. UNLESS OTHERWISE NOTED, ALL GYPSUM BOARD SURFACES, WALLS, AND CEILINGS SHALL BE TAPED, SANDED SMOOTH TO A "LEVEL 4" FINISH, SO AS TO RECEIVE PAINT OR WALL COVERING MATERIAL D. EQUIPMENT SPECIFICATIONS & COUNTS SHOWN FOR DESIGN INTENT ONLY AND SHOULD NOT BE USED FOR ORDERING. COORDINATE ALL EQUIPMENT COUNTS, LOCATIONS & SPECIFICATIONS WITH CLIENT PRIOR TO FINALIZING, E. FURNITURE COUNTS SHOWN FOR DESIGN INTENT ONLY AND SHOULD NOT BE USED FOR ORDERING. COORDINATE ALL FURNITURE COUNTS, LOCATIONS & SPECIFICATIONS WITH CLIENT PRIOR TO FINALIZING. F. CONTRACTOR MUST NOTIFY ARCHITECT / DESIGNER OF ANY DISCREPANCY IN PLANS. FINISH ITEMS CLEARLY SHOWN IN PLANS, BUT OMITTED FROM SCHEDULES OR LEGENDS MUST STILL BE PROVIDED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO VERIFY OMITTED FINISHES WITH ARCHITECT OR DESIGNER PRIOR TO ORDERING PRODUCTS. G. ALL FILE PEDESTALS ARE TO BE CONFIGURED FOR "FRONT TO BACK" FILING AND BE ABLE TO ACCEPT METAL HANGERS TO ACCEPT PENDAFLEX TYPE FILE FOLDERS, UNLESS NOTED AS LATERAL. H. ALL COUNTER TOPS TO BE 24" DEEP, UNLESS OTHERWISE SPECIFIED. COUNTER TOPS TO BE SCRIBED TIGHTLY TO BACK AND SIDE WALLS. I. ALL BACKSPLASHES TO BE SCRIBED TO WALLS, AND MUST BE FLUSH TO EDGE OF BASE, UNLESS OTHERWISE SPECIFIED. ALL COUNTER TRANSITION SEAMS MUST BE CAULKED SEALED, VERIFY EITHER MATCHING COLOR CAULK OR CLEAR SILICONE. J. PROVIDE SIDE SPLASHES AT LOCATIONS ADJACENT TO WALLS OR WINDOWS, U.N.O. K. FACES OF PIGEONHOLES TO MATCH WORK SURFACE LAMINATE. COLOR OF EDGE BANDING ON ALL DOORS TO MATCH FACE MATERIAL. L. INSTALL MATERIALS ACCORDING TO MANUFACTURER'S SUGGESTED INSTALLATION AND PREPARATION/ MAINTENANCE SPECIFICATIONS OR BETTER, U.N.O.. MAX ALUMINUM �1 THRESHOLD- 2 ADA COMPLIANT e a FLOORING SUBSTRATE WALK OFF MAT AS SPECIFIED 6' - T-0' FLOORING SUBSTRATE GLUE DOWN WALK -OFF MAT AS SPECIFIED - 69-11-01 PLATE AT STOREFRONT/ WALK_ OFF MAT REDUCER STRIP AS SPECIFIED 77a a L�VZT FLOORING AS SPECIFIED q STRIP DETAIL - WAL OFF MAT FURNITURE, FIXTURE AND EQUIPMENT KEYNOTES OCOORDINATE ACCESS TO POWERIDATA FOR FURNITURE - SEE ELECTRICAL DRAWINGS. OG.C. TO PROVIDE F.R.T. BLOCKING WITHIN WALLS BEHIND VERTICAL MEMBERS OF FIXTURES AS REQ'D. COORDINATE WITH FIXTURE VENDOR. OPRE -FABRICATED FIXTURES - PROVIDED AND INSTALLED BY FIXTURE VENDOR OPROVIDE LEVEL FLOOR IN RETAIL AREA FOR LEVEL INSTALLATION OF MILLWORK AND FLOOR FINISHES OIF NOT EXISTING G.C. TO PROVIDE - "EXIT ROUTE" TACTILE SIGNAGE REQUIRED AT ALL EXITS. SEE SHEET A0.2 FOR REQUIREMENTS. OIF NOT EXISTING G.C. TO PROVIDE TACTILE "EXIT" SIGNAGE - TACTILE SIGNAGE REQUIRED AT ALL EXITS. SEE BHT A0.2FOR REQUIREMENTS. OPROVIDE AND INSTALL ALL NECESSARY WALL BACKING, STIFFENERS,BRACING, BACK-UP PLATES AND/OR SUPPORTING BRACKETS AS REQUIRED FOR THE INSTALLATION OF WALL -MOUNTED OR SUSPENDED EQUIPMENT OR BUILT-IN ITEMS. VERIFY REQUIREMENTS WITH MANUFACTURERS PRIOR TO INSTALLATION. OALL WALLS AT SALES AREA TO BE PAINTED PT -1 UP TO EXISTING CEILING (U.N.O.) O3'-9'X V-10" XR MARCON NON -LIT FRAME GRAPHIC - MOUNT BOTTOM AT 6-118" A.F.F. 10 EXISTING GLAZING AND STOREFRONT FRAME TO REMAIN -CLEAN TO "LIKE NEW" CONDITION. G.C. TO PROVIDE AND INSTALL 3M SCOTCHSHIELD SAFETY AND SECURITY WINDOW FILM AT ALL STOREFRONT GLAZING. INSTALL PER MFG. RECOMMENDATIONS. SEE EXTERIOR ELEVATION 51A4.0 FOR ADDITIONAL WINDOWS. 11 COUNTERTOP TO BE 34" A.F.F. MAXIMUM 12 DASHED LINES INDICATE LOCATION OF FUTURE FN -07 CONSULTATION TABLE &(2) FN -04A EIFFEL BARSTOOL 13 PIN MOUNTED STAINLESS STEEL CUSTOMER COMMITMENT SEAL - MOUNTED AT 6-10" A.F.F. TO BOTTOM 14 NEW TV - CONFIRM MOUNTING HEIGHTS WITH FIXTURE VENDOR 15 NEW EQUIPMENT TRANSFER 16 NEW ENTRANCE MAT 17 NEW EXPRESS PAY KIOSK. SEE 4/A2.0 FOR MORE INFORMATION EXISTING STOREFRONT ENTRY DOOR TO REMAIN (V.I.F.) CLEAN TO A 18 'LIKE NEWCONDITION. G.C. SHALL ENSURE THRESHOLD COMPLIES WITH ADA REQUIREMENTS, AND MEETS ALL LOCAL, STATE AND NATIONAL CODES FOR ACCESSIBILITY. 19 EXISTING DOOR & HARDWARE TO REMAIN (V.I.F.) 20 EXISTING VESTIBULE GLAZING TO REMAIN. 21 INFILL FORMER WINDOW LOCATION. MATCH ADJACENT CONSTRUCTION AND ALIGN FINISHES ON EACH SIDE (V.I..F.) 518" TYPE "X" GYP. BD EACH SIDE OVER 3-5/8" METAL STUD - SEE STUD TABLE FOR SPACING INSULATION WHERE IT OCCURS -3.518" METAL TRACK 3-518" METAL STUD NESTED IN METALTRACK DOOR FRAME PER SCHEDULE F.R.T. WOOD BLOCKING AS REQ'D PER DOOR SCHEDULE TYPICAL HEAD DET, 1-1/21-11-01 EXISTING VCT FLOORING FEATURE STRIP AS SPECIFIED LVT FLOORING AS SPECIFIED r r f h i FLOORING SUBSTRATE TRANSITION STRIP - VCT /LVT 6' - T -0 - WALL LEGEND EXISTING CONSTRUCTION TO REMAIN NEW 3 5/8" METAL STUDS W/ 518' TYPE'X" W1 GYP. BD. ON BOTH SIDES - TO 6" ABOVE CEILING 1 W Z CV W Q U � W U > rr W^ U) 0 U) W O Q 0 �:17-_ U) O Z) 00 U r U) 0 W no II Bid Issue: 09/13/2019 Landlord Issue: 09/13/2019 Permit Issue: 09/13/2019 Construction Issue: T.B.D. FURNITURE, FIXTURE & EQUIPMENT PLAN Comm. Number 83-1189 Date 09/13/2019 Drawn By RFV Checked By RFV A2.0 LIGHTING SYMBOL LEGEND SYMBOL DESCRIPTION I COMMENTS SYMBOL DESCRIPTION 1 COMMENTS EXISTING EXIT SIGNAGE TO REMAIN n IIIII�UI�u�� IIIIIIIIII EXISTING FIXTURE TO REMAIN EX EXISTING FIXTURE TO REMAIN o EX EXISTING FIXTURE TO REMAIN 0 EXISTING FIXTURE TO REMAIN EX EXISTING FIXTURE TO REMAIN � U 4 EXISTING SPRINKLER HEAD TO REMAIN NOTE: REFER TO ELECTRICAL DRAWINGS FOR MODEL NUMBERS, AND ELECTRICAL INFORMATION 0M11000mmi MMMMMM1 101 DKIIIIIIII TYP. 4 TYP. � I O EX EX 3 TYP. EXISTING VESTIBULE 100 10 7'-10 314" A.F.F. EXISTING SUSPENDED CLG. 7'-10 1/2" A. F.F. EXISTING SUSPENDED CEILING T-1' A.F.F. EXISTING GYP. BD. SOFFIT is EX I LEX _r 1 7-10 1/2" A.F.F. EXISTING SUSPENDED CEILING REFLECTED CEILING PLAN 1/4° -1'-0' RCP KEYNOTES: O NOT USED 0 NOT USED O G.C. TO CLEAN EXISTING GRID AND REPLACE DAMAGED OR SOILED PANELS -TYP. O EXISTING LIGHTING TO REMAIN. REPAIR I REPLACE AS NECESSARY. E N�S W GENERAL NOTES: A. FIELD VERIFY ALL CLEARANCES OF DUCTS, PIPES, SPRINKLERS, ETC., AND NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO INSTALLATION OF LIGHTS, ETC.. B. ALL LIGHT FIXTURES ATTACHED TO THE CEILING GRID, MUST ALSO BE INDEPENDENTLY SUPPORTED. C. PROVIDE BACK-UP POWER FOR EXIT SIGNS PER STATE AND LOCAL CODES. D. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED TOALEVEL OF NOT LESS THAN ONE FOOT CANDLE AT THE WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. E. EMERGENCY LIGHTING SHALL BE (2) SEPERATE SOURCES OF POWER AND SHALL COMPLY WITH THE NEC. F. CONTRACTOR SHALL PROVIDE EMERGENCY LIGHTING, STROBE LIGHTS, AUDIO-VISUAL ALARMS AND OCCUPANCY SENSORS TO MEET ALL APPLICABLE CODES. G. CONTRACTOR SHALL PROVIDE LAMPS WITH TYPE IC RATED HOUSING WHERE FIXTURES COME IN DIRECT CONTACT WITH INSULATION. H. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED AT ALL TIMES AND SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM (BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR) THAT WILL AUTOMATICALLY ILLUMINATE THE EXIT SIGNS FORA DURATION OF NOT LESS THAN 90 MINUTES. I. FIELD VERIFY ALL CLEARANCES OF DUCTS, PIPES, SPRINKLERS, ETC., AND NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO INSTALLATION OF LIGHTS, ETC.. J. ALL JUNCTION BOXES AND MECHANICAL EQUIPMENT REQUIRING ACCESS FOR SERVICE SHALL BE LOCATED OVER ACOUSTICAL CEILINGS. NO ACCESS HATCHES SHALL BE INSTALLED IN GYPSUM BOARD CEILINGS WITHOUT PRIOR APPROVAL BY ARCHITECT. (NO EXCEPTIONS). K. COORDINATE SECURITY REQUIREMENTS WITH SECURITY VENDOR FOR ALL CEILING MOUNTED ITEMS. L. PROVIDE EXTRA BOX OF EACH CEILING TILE USED TO STORE MANAGER FOR FUTURE USE. M. FIELD VERIFY CEILING GRID LOCATION AND NOTIFY ARCHITECT OF ANY DISCREPANCIES ON PLANS. N. FIELD VERIFY ALL CLEARANCES OF DUCTS, PIPES, SPRINKLERS, ETC., AND NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO INSTALLATION OF CEILING, ETC.. 0. ALL FIRE SPRINKLERS TO BE RECESSED. SPRINKLER HEADS TO BE WHITE. AVOID STROBES IN SOFFITS. CENTER SPRINKLER HEAD IN CEILING TILE. P. SPRINKLER HEADS ARE TO BE CENTERED BETWEEN LIGHTS IN A UNIFORM ARCHITECTURAL PATTERN. Q. LOCATE RECESSED DOWN LIGHTS, WALL WASHERS, SMOKE DETECTORS, EXIT SIGNS, SPEAKERS, FIRE SPRINKLERS, ETC. IN CENTER OF CEILING TILES. R. GYPSUM BOARD WALL FINISH TO EXTEND 6" ABOVE ADJACENT CEILING. S. DIMENSIONS ON THIS PLAN ARE FROM FINISH FACE, UNLESS NOTED OTHERWISE. T. PROVIDE FULLY RECESSED HEADS WITH TRIM PIECES TO MATCH ADJACENT COLOR IF LOCATED IN GWB SOFFITS. tc`a L.I". d' W F_ Z o T 0 101 DKIIIIIIII TYP. 4 TYP. � I O EX EX 3 TYP. EXISTING VESTIBULE 100 10 7'-10 314" A.F.F. EXISTING SUSPENDED CLG. 7'-10 1/2" A. F.F. EXISTING SUSPENDED CEILING T-1' A.F.F. EXISTING GYP. BD. SOFFIT is EX I LEX _r 1 7-10 1/2" A.F.F. EXISTING SUSPENDED CEILING REFLECTED CEILING PLAN 1/4° -1'-0' RCP KEYNOTES: O NOT USED 0 NOT USED O G.C. TO CLEAN EXISTING GRID AND REPLACE DAMAGED OR SOILED PANELS -TYP. O EXISTING LIGHTING TO REMAIN. REPAIR I REPLACE AS NECESSARY. E N�S W GENERAL NOTES: A. FIELD VERIFY ALL CLEARANCES OF DUCTS, PIPES, SPRINKLERS, ETC., AND NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO INSTALLATION OF LIGHTS, ETC.. B. ALL LIGHT FIXTURES ATTACHED TO THE CEILING GRID, MUST ALSO BE INDEPENDENTLY SUPPORTED. C. PROVIDE BACK-UP POWER FOR EXIT SIGNS PER STATE AND LOCAL CODES. D. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED TOALEVEL OF NOT LESS THAN ONE FOOT CANDLE AT THE WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. E. EMERGENCY LIGHTING SHALL BE (2) SEPERATE SOURCES OF POWER AND SHALL COMPLY WITH THE NEC. F. CONTRACTOR SHALL PROVIDE EMERGENCY LIGHTING, STROBE LIGHTS, AUDIO-VISUAL ALARMS AND OCCUPANCY SENSORS TO MEET ALL APPLICABLE CODES. G. CONTRACTOR SHALL PROVIDE LAMPS WITH TYPE IC RATED HOUSING WHERE FIXTURES COME IN DIRECT CONTACT WITH INSULATION. H. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED AT ALL TIMES AND SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM (BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR) THAT WILL AUTOMATICALLY ILLUMINATE THE EXIT SIGNS FORA DURATION OF NOT LESS THAN 90 MINUTES. I. FIELD VERIFY ALL CLEARANCES OF DUCTS, PIPES, SPRINKLERS, ETC., AND NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO INSTALLATION OF LIGHTS, ETC.. J. ALL JUNCTION BOXES AND MECHANICAL EQUIPMENT REQUIRING ACCESS FOR SERVICE SHALL BE LOCATED OVER ACOUSTICAL CEILINGS. NO ACCESS HATCHES SHALL BE INSTALLED IN GYPSUM BOARD CEILINGS WITHOUT PRIOR APPROVAL BY ARCHITECT. (NO EXCEPTIONS). K. COORDINATE SECURITY REQUIREMENTS WITH SECURITY VENDOR FOR ALL CEILING MOUNTED ITEMS. L. PROVIDE EXTRA BOX OF EACH CEILING TILE USED TO STORE MANAGER FOR FUTURE USE. M. FIELD VERIFY CEILING GRID LOCATION AND NOTIFY ARCHITECT OF ANY DISCREPANCIES ON PLANS. N. FIELD VERIFY ALL CLEARANCES OF DUCTS, PIPES, SPRINKLERS, ETC., AND NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO INSTALLATION OF CEILING, ETC.. 0. ALL FIRE SPRINKLERS TO BE RECESSED. SPRINKLER HEADS TO BE WHITE. AVOID STROBES IN SOFFITS. CENTER SPRINKLER HEAD IN CEILING TILE. P. SPRINKLER HEADS ARE TO BE CENTERED BETWEEN LIGHTS IN A UNIFORM ARCHITECTURAL PATTERN. Q. LOCATE RECESSED DOWN LIGHTS, WALL WASHERS, SMOKE DETECTORS, EXIT SIGNS, SPEAKERS, FIRE SPRINKLERS, ETC. IN CENTER OF CEILING TILES. R. GYPSUM BOARD WALL FINISH TO EXTEND 6" ABOVE ADJACENT CEILING. S. DIMENSIONS ON THIS PLAN ARE FROM FINISH FACE, UNLESS NOTED OTHERWISE. T. PROVIDE FULLY RECESSED HEADS WITH TRIM PIECES TO MATCH ADJACENT COLOR IF LOCATED IN GWB SOFFITS. tc`a L.I". d' W F_ Z o 0 Q w � U q_ > 0�ry I - w cW O U Z) 2 MQ LU 0 �_ 0Z) U) 00 U cn M r C O CL U N O r1w CO rA Bid Issue: 09/13/2019 Landlord Issue: 09/13/2019 Permit Issue: 09/13/2019 Construction Issue: T.B.D. REFLECTED CEILING PLAN Comm. Number 83-1189 Date 09/13/2019 Drawn By RFV Checked By RFV 3.0 INTERIOR E 1/4' -1'-0' 4 IF LEVATION ILLWORK PROVIDED, ASSEMBLED & INSTALLED BY XFINITY VENDOR CIGNAGE BY XFINITY FIXTURE VENDOR tlenceXl In[eme � 13 LL ll \ O \ p Z \ iI F 9 6 X W 10 o — — ----N 5112.. 1'-1112" FX -12B WBS'CX-04B WB -3 X -04B WB -3 EQ -1200 WB -3 CL ti ( rL (L INTERIOR ELEVATION 1/4' - T-0' PIN MOUNTED STAINLESS STEEL CUSTOMER COMMITMENT SEAL r. NTERIOR ELEVATION �_) 1/4' -1'-0' IF NOT EXISTING G.C. TO PROVIDE TACTILE EXIT SIGNAGE. SEE AO.2 FOR REQUIRMENTS----� 1 INTERIOR E 4A 1/4' - T-0' EXISTING VESTIBULE - EXISTING FRONT ENTRY BEYOND 1'-8718" 1'•87/8' EQ EQ PT -1 �I LEVATION J U O z X W O Cd O H N71-3 c1 [F3 EXTERIOR ELEVATION INTERIOR & EXTERIOR INTERIOR & EXTERIOR d• ELEVATION KEYNOTES ELEVATION NOTES OT_9" X F-10" XR MARCON NON -LIT FRAME GRAPHIC - MOUNT BOTTOM AT 6.118" A. ALL GRAPHICS TO BE DETERMINED. REFER TO- INo A.F.F. SEPARATE COMCA GRAPHIC PRODUCTION U � TTT n m w WORKSHEET FOR ADDITIONAL INFORMATION. D �lj ARCHITECT STOREFRONT SIGNAGE IS SHOWN FOR2O > EXISTING CONSTRUCTION AND FINISHES TO REMAIN (TYP.) W 1}{U 1Njll ju'j' GRAPHIC REPRESENTATION ONLY. FINAL U) p 75 W Dry W =Q SIZE AND LOCATION IS TO BE COORDINATED 3 O EXISTING GLAZING SYSTEM AND STOREFRONT FRAME TO REMAIN O �:_ . . _ WITH THE SIGN CONTRACTOR. - CLEAN TO A "LIKE NEW" CONDITION. G.C. TO PROVIDE AND D 00 U . . . . (n INSTALL 3M SCOTCHSHIELD SAFETY AND SECURITY WINDOW FILM 55 5 TH RC S. , AT ALL STOREFRONT GLAZING. INSTALL PER MFG. SAINT PAUL._I E T O 5 RECOMMENDATIONS. '1 6 1 2 t3:3 4 O NOT USED I OINTERNALLY ILLUMINATED TENANT SIGN. SIGN CONTRACTOR TO PROVIDE SHOP DRAWINGS IN ACCORDANCE WITH ALL LANDLORD CRITERIA PRIOR TO FABRICATION. ALL SIGNS TO BE IN ACCORDANCE WITH MALL CRITERIA AND LOCAL REQUIREMENTS AND TO BE INSTALLED UNDER SEPARATE PERMIT O6 EQUIPMENT STORAGE, G.C. TO PROVIDE (1) WALL DUPLEX POWER,(2) DATA. OUTLETS LOCATED AS SHOWN IN ELEVATIONS. MOUNTED VERTICAL. ONOT USED. ED ARcNT ags B INTERNET WALL DISPLAY, G.C. TO PROVIDE (1) WALL DUPLEXs POWER, (2) DATA (1) COAX. OUTLET LOCATED AS SHOWN IN A. ELEVATIONS. MOUNTED VERTICAL. = R'L /t OEXPERIENCE X1 TV WALL, G.C. TO PROVIDE (1) WALL DUPLEXrpiaryy'� POWER, (2) DATA, (1) COAX. OUTLETS LOCATED AS SHOWN IN13,¢yiR f rnas ELEVATIONS. MOUNTED VERTICAL. 10 ACCESSIBLE POS. G.C. TO PROVIDE (1) WALL DUPLEX POWER, (2) DATA OUTLETS LOCATED WHERE SHOWN IN ELEVATION. MOUNTED VERTICAL. 11 S TV- G.C. TO PROVIDE (1) WALL DUPLEX POWER, (2) DATA, (1) COAX. OUTLETS LOCATED WHERE SHOWN IN ELEVATION. MOUNTED VERTICAL. 12 NOT USED. 13 NEW EXPRESS PAY KIOSK. G.C. TO PROVIDE (1) WALL DUPLEX POWER, (1) DATA OUTLET LOCATED WHERE SHOWN IN ELEVATION. MOUNTED HORIZONTALLY. 14 SIGN VENDOR TO VERIFY LOCATION WITH XFINITY/ COMCAST CONSTRUCTION MANAGER. 5 o�� O 2 uu ,4 3 3 `J 0 o �� 0 yr Q �L U U) N r1, r Bid Issue: 09/13/2019 Landlord Issue: 09/13/2019 Permit Issue: 09/13/2019 Construction Issue: T.B.D. ELEVATIONS - INTERIOR & EXTERIOR Comm. Number 83-1189 Date 09/13/2019 Drawn By RFV Checked By RFV 0. d• Z INo U Q w � U p= > W uwj O U) p 75 W Dry W =Q O �:_ U OI.- D 00 U t- (n a� 10 0 yr Q �L U U) N r1, r Bid Issue: 09/13/2019 Landlord Issue: 09/13/2019 Permit Issue: 09/13/2019 Construction Issue: T.B.D. ELEVATIONS - INTERIOR & EXTERIOR Comm. Number 83-1189 Date 09/13/2019 Drawn By RFV Checked By RFV CABLE TYPE KEY CABLE CODE MANUFACTURER ELECTRICAL SYMBOLS DESCRIPTION LIGHTING CONTROL DESCRIPTION MOUNTING WIRING DEVICE DESCRIPTION MOUNTING BRANCH CIRCUITING x SWITCH, WHERE "X" CAN BE 46" ZQ RECEPTACLE OPTIONS DENOTED BY "X", WHERE 169' ONE OF THE FOLLOWING: W "X" CAN BE ONE OF THE FOLLOWING: JACKET COLOR LP -1-1 —PANEL NAME 0 2 = DOUBLE POLE BELDEN 2413 IG =ISOLATED GROUND 23 1,3,5 ---CIRCUIT NUMBER(S) UNSHIELDED 3 = THREE WAY BLUE PREMISE HORIZONTAL CABLE, GIGABIT GFI = GROUND FAULT INTERRUPTER Z) GROUND CONDUCTOR 4 = FOUR WAY W TR = TAMPER RESISTANT <C / NEUTRAL CONDUCTOR -�— ETHERNET, POE, POE+, 100BASETX, K = KEYED 0 >_ SS = SURGE SUPPRESSOR3�a" CABLES �- PHASE CONDUCTORS LV = LOW VOLTAGE o= WP = WEATHERPROOF 00 16 U MC = MOMENTARY WITH RTC 0 USB = COMBINATION USB/RECEPTACLE CONDUIT AND WIRE SIZE OS = OCCUPANCY SENSOR (blank) = STANDARD RECEPTACLE (1 /2" C, 2#12, UNLESS (blank) = SINGLE POLE NOTED OTHERWISE) -ex SIMPLEX RECEPTACLE, NORMAL POWER 18" 600W DIMMER SWITCH, OPERATING 46" :IQx DUPLEX RECEPTACLE, NORMAL POWER 18" ',. WATTAGE INDICATED ALIGHT �x DUPLEX RECEPTACLE, UPS POWER 18" LIGHT FIXTURE DESIGNATOR, REFER TO SWITCH WITH PILOT LIGHT 46" A'�FIXTURE SCHEDULE FOR TYPE AND VOLTAGE x DUPLEX RECEPTACLE, EMERGENCY POWER 18" ® S Y r ® OCCUPANCY SENSOR, WHERE 96" OR 6" BELOW *X FOURPLEX RECEPTACLE 18" ° \'CIRCUIT NUMBER \SWITCH "Y" IS THE RATED AREA OF FINISHED CLG WHICH LEG COVERAGE AND "X" IS ONE OF EVER IS LOWER THE FOLLOWING: � FLOOR OUTLET BOX, DT =DUAL TECHNOLOGY POWER, VOICE AND/OR DATA EXAMPLE: US = ULTRASONIC ANLL BOUNDARY LINE. CIRCUIT PIR = PASSIVE INFRARED 10-30RALL DEVICES WITHIN THIS BORDER SPECIAL PURPOSE RECEPTACLE, WITH NEMA CONFIGURATION NOTED 18" - - TO THE PANEL(S) INDICATED. DAYLIGHT SENSOR, WHERE "X" CLG. 46 GFI DUPLEX GFI RECEPTACLE X IS THE TYPE OF SENSOR PC 5� MULTIOUTLET ASSEMBLY, REFER TO SPEC I 4A I MOUNTED AT 46" AFF, 'WIRED FOR TYPE AND RECEPTACLE SPACING I I TO PANEL LP -1-1A, CIRCUIT 4. r��� LJ- DISCONNECT SWITCH, NON-FUSED IG ISOLATED GROUND DUPLEX 7 RECEPTACLE MOUNTED IAT 18" DESIGN PRESENTATION DESCRIPTION DISCONNECT SWITCH, FUSED I I AFF, WIRED TO PANEL LP -1-1, CIRCUIT 7. O KEY NOTE, REFER TO UST OF KEY NOTES MS MOTOR STARTER SWITCH WITHOUT I 1 cc:DUPLEX RECEPTACLE MOUNTED IG AT 18" AFF, WIRED TO '!PANEL ON THE SAME PLAN 54" LP OVERLOAD PROTECTION -11-11A, ELP-1-1 ELP-1-1, CIRCUIT 1. OFEEDER NOTE, REFER TO FEEDER SCHEDULE MSS � MOTOR STARTER SWITCH WITH 54" ON THE SAME PLAN OVERLOAD PROTECTION Q1 DRAWING REVISION NOTE EF -1 MAGNETIC MOTOR STARTER WITH ® EQUIPMENT NUMBER INDICATED CONCEALED RACEWAY EF -1 COMBINATION MOTOR STARTER AND POWER DISTRIBUTION NAMING CONVENTION RACEWAY INSTALLED BELOW M FUSEDDISCONNECTWTH EQUIPMENT 0 a ©� ❑-❑-� ❑ FINISHED GRADE/UNDER SLAB � � EXPOSED RACEWAY AHU EQUIPMENT TAG REFER TO EQUIPMENT ( } I� EQUIPMENT ID: " " SINGLE TUB 1 SCHEDULE) "A" SECOND TUB I ✓^�j RACEWAY UP "B" THIRD TUB i RACEWAY DOWN 208/120 VOLT PANELBOARD EQUIP. NUMBER: "1" FIRST PANEL "2" SECOND PANEL, ETC... /^y CONDUIT STUB, BUSHED AND CAPPED ® 480/277 VOLT PANELBOARD FLOOR NUMBER (�— UNDERFLOOR DUCT, POWER AND TERMINAL CABINET I (ADDITIONAL SPACE AS NEEDED) Lam- COMMUNICATIONS RACEWAYS ANNUNCIATOR PANEL EQUIPMENT TYPE: "P" BRANCH CIRCUIT PANELBOARD "D" DISTRIBUTION PANEL "T" TRANSFORMER "SB" SWITCHBOARD FIRE ALARM DESCRIPTION MOUNTING"SG" SWITCHGEAR "MCC" MOTOR CONTROL CENTER MISCELLANEOUS DESCRIPTION MOUNTING "SUB" SUBSTATION x"ATS" AUTOMATIC TRANSFER SWITCH F FIRE ALARM DEVICE, WHERE "X" CAN BE "MTS" MANUAL TRANSFER SWITCH �j JUNCTION BOX, RECESSED WALL ONE OF THE FOLLOWING: SERVICE VOLTAGE: "L" 208 OR 208/120 VOLTS Q JUNCTION BOX, RECESSED CEILING (blank) FIRE ALARM MANUAL PULL STATION 46" "H" 480 OR 480/277 VOLTS K FIRE ALARM MANUAL KEYED STATION 46" D PUSHBUTTON 46" H THERMAL DETECTOR ELECTRICAL SYSTEM: NORMAL (UTILITY) P PHOTOELECTRIC SMOKE DETECTORE EQUIPMENT rc TIME CLOCK DS DUCT SMOKE DETECTOR "Co CRITICAL "S" FL SPRINKLER VALVE FLOW SWITCH LIFE SAFETY MM MONITOR MODULE "T" TECHNOLOGY Ci CONTACTOR CM CONTROL MODULE "U" UPS D MAGNETIC DOOR HOLDER COAX OUTLET TS DUCT DETECTOR REMOTE TEST STATION 80" H kE< FIRE ALARM HORN 90" OR 6" BELOW SECURITY DESCRIPTION MOUNTING FINISHED CEILING EVER IS WHICH LOWER ELECTRICAL SHEET INDEX S FIRE ALARM SPEAKER 90" OR 6" BELOW XF a SECURITY DEVICE, WHERE "X" CAN BE FINISHED CEILING WHICH ONE OF THE FOLLOWING: EVER IS LOWER E1.0 - ELECTRICAL SYMBOL LEGEND, POWER AND I� O FIRE ALARM STROBE 90" OR 6" BELOW LOW VOLTAGE PLAN DC =MAGNETIC DOOR CONTACTS FINISHED CEILING WHICH ODC = MAGNETIC OVERHEAD DOOR CONTACTS EVER IS LOWER E2.0 -ELECTRICAL SPECIFICATIONS GB = GLASS BREAK DETECTOR H MD = MOTION DETECTOR F FIRE ALARM HORN WITH 90" OR 6" BELOW CR = CARD READER 46" STROBE FINISHED CEILING WHICH KP = KEYPAD 46" EVER IS LOWER S F FIRE ALARM SPEAKER WITH 90" OR 6" BELOW COMMUNICATIONS DESCRIPTION MOUNTING STROBE FINISHED CEILING WHICH EVER IS LOWER < DATA OUTLET 18" b F FIREFIGHTER PHONE 46" JACK I� FIRE ALARM BELL 80" SPRINKLER VALVE POSITION SWITCH CABLE TYPE KEY CABLE CODE MANUFACTURER PART # DESCRIPTION AWG INSULATION MATERIAL OUTER SHIELD OUTER JACKET STANDARD USED FOR UL FLAME TEST 111 U W DIAMETER (IN) JACKET COLOR U_ 0 TYPE A BELDEN 2413 MULTI -CONDUCTOR -ENHANCED 23 FRPO/FEP UNSHIELDED 0.22400 BLUE PREMISE HORIZONTAL CABLE, GIGABIT NFPA 262 Z) CATEGORY 6 NONBONDED-PAIR W <C ETHERNET, POE, POE+, 100BASETX, PLENUM FLAME 0 >_ CABLES o= 100BASEVC ANYLAN, 155 ATM, 622 ATM, 00 U T- 0 250MHZ CATEGORY 6 NOTE; EXISTING CONDITIONS WERE TAKEN FROM SITE VISITS AND MAY NOT REFLECT EXACT "AS -BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. IF ANY DISCREPANCIES, CONTACT ENGINEER AT (651) 748-1100. NOTE: SEE ARCHITECTURAL SHEET A4.0 FOR WALL POWER AND DATA LOCATIONS ON SALES FLOOR. NOTE: HVAC UNITS AND ALL ASSOCIATED COMPONENTS, DUCT SMOKE DETECTORS, RECEPTACLES, CONDUITS, FEEDERS, DISCONNECT SWITCHES, ETC. ARE EXISTING TO REMAIN. MAINTAIN EXISTING ELECTRICAL CONNECTIONS AND CONTROL. ELECTRICAL GENERAL NOTES A. ALL CORE BORING, TRENCHING AND PATCHING OF CONCRETE SLAB FLOORS AS REQUIRED FOR THE INSTALLATION OF THE ELECTRICAL SYSTEMS SHOWN SHALL BE BY THE ELECTRICAL CONTRACTOR. ALL CONDUITS SHALL BE IN COMMON TRENCH WHERE PRACTICAL. FINISH ALL SURFACES TO MATCH EXISTING SURFACES, CUTTING OR WELDING OF STRUCTURAL MEMBERS SHALL BE ALLOWED ONLY WITH WRITTEN APPROVAL OF THE LANDLORD, STRUCTURAL ENGINEER AND ARCHITECT. MAINTAIN RATINGS OF ALL ASSEMBLIES.. B. ALL CUTTING AND PATCHING OF THE ROOF AS REQUIRED FOR THE INSTALLATION OF THE ELECTRICAL SYSTEMS SHOWN SHALL BE PROVIDED BY THE LANDLORD'S ROOFING CONTRACTOR AT THE TENANT'S ELECTRICAL CONTRACTOR'S EXPENSE. C. EXISTING EQUIPMENT, DEVICES, CONDUIT AND WIRING MAY BE RE -USED WHERE APPLICABLE AND MEETS CURRENT CODE REQUIREMENTS, UNLESS OTHERWISE NOTED. D. REMOVE ALL EQUIPMENT, DEVICES, EXPOSED CONDUIT AND WIRING NOT BEING RE -USED. E. COORDINATE WITH THE LANDLORD IF CONCEALED CONDUIT NOT BEING RE -USED MAY BE ABANDONED IN PLACE. F. SPECIFIC CIRCUITS WERE CHOSEN IN ACCORDANCE WITH THE INFORMATION AVAILABLE IN ORDER TO CORRESPOND TO THE EXISTING INSTALLATION. THE ELECTRICAL CONTRACTOR SHALL MAKE MAXIMUM PRACTICAL USE OF EXISTING CONDUIT AND WIRING AND RE -ASSIGN CIRCUITS AS REQUIRED. PROVIDE NEW TYPE WRITTEN DIRECTORIES IN PANELBOARD DOOR(S). G. THE CONTRACTOR CAN COMBINE HOMERUNS WHEN CONDUIT AND WIRE CODE REQUIREMENTS ARE ADHERED TO. H. ELECTRICAL CONTRACTOR SHALL VERIFY VOLTAGE AND PHASE OF ALL MECHANICAL EQUIPMENT FURNISHED BY OTHERS PRIOR TO ANY ROUGH -IN. IF THERE IS A CONFLICT BETWEEN DRAWINGS AND EQUIPMENT FURNISHED, NOTIFY THE ENGINEER AT (651)748-1100. I. ALL LINE VOLTAGE WIRING SHALL BE IN E.M.T. OR RIGID CONDUIT. PVC MAY BE USED WHEN BURIED. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTION FROM A J -BOX OR OVER CURRENT DEVICE TO A LIGHT FIXTURE, MOTOR, APPLIANCE, ETC PER N.E.C., MAXIMUM LENGTH 6 FEET, LIQUIDTIGHT COATED PVC SHALL BE USED IN ALL DAMP OR WET LOCATIONS. TYPE BX, ROMEX OR ARMORED CABLE SHALL NOT BE ALLOWED. J. ALUMINUM CONDUCTORS SHALL NOT BE ALLOWED WITHOUT WRITTEN APPROVAL OF THE ENGINEER, (651)748-1100. K. ALL PANELBOARDS SHALL BE BALANCED BETWEEN PHASES AS PER LANDLORD REQUIREMENTS, ADJUST CIRCUITING AS REQUIRED PER FIELD CONDITIONS. L. ALL EMERGENCY AND EXIT LIGHTING SHALL MEET OR EXCEED THE LOCAL AUTHORITIES REQUIREMENTS. 1 ADJUST THE INDICATED SYSTEM AS NEEDED. COORDINATE WITH THE LOCAL AUTHORITY PRIOR TO BID. M. TENANTS ELECTRICAL CONTRACTOR SHALL DISCONNECT, REMOVE AND DISPOSE OF ALL EQUIPMENT, DEVICES, CONDUIT, WIRE, ETC., NOT BEING RE -USED. N. ELECTRICAL MATERIALS REQUIRING DISPOSAL TO A HAZARDOUS CLASSIFICATION SHALL BE DISPOSED OF AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. ALL COSTS SHALL BE INCLUDED IN THE CONTRACT. UPON REQUEST, CERTIFICATION OF PROPER DISPOSAL SHALL BE SUBMITTED TO THE OWNER. 0. LOCATE, IDENTIFY AND PROTECT ALL ELECTRICAL SERVICES PASSING THROUGH THE TENANT SPACE. WHEN SERVICES MUST BE INTERRUPTED, COORDINATE WITH LANDLORD AND OWNER PRIOR TO ANY CONSTRUCTION, POWER AND LOW VOLTAGE PLAN KEYED NOTES 1. LOCATE POWER AND DATA DEVICES SUCH THAT THEY ARE CENTERED ON A CABINET DOOR. MOUNTING HEIGHT AS INDICATED. COORDINATE EXACT POWER AND DATA LOCATIONS WITH ARCHITECTURAL SHEETS AND MILLWORK MANUFACTURER. 2. EXISTING LIGHTING, POWER, FIRE ALARM DEVICES AND DATA IN THESE AREAS TO REMAIN UNLESS NOTED OTHERWISE. NO WORK REQUIRED. 3. PROVIDE CAT6 LOW VOLTAGE CABLES TO EACH LOCATION AS INDICATED. QUANTITY OF LV CABLES IS NOTED AT EACH FIXTURE. ROUTE LOW VOLTAGE CABLE FROM DEVICE TO SERVICE RACK. SEE CABLE SCHEDULE THIS SHEET FOR CABLE TYPE. COORDINATE EXACT REQUIREMENTS WITH FIXTURE VENDOR FOR COAX LOW VOLTAGE AND POWER REQUIREMENTS AT FLOOR FIXTURE. 4. TRENCH FLOOR TO LOCATION SHOWN FOR ROUTING OF POWER �P) AND CAT6 LOW VOLTAGE (LV) CABLING TO FLOOR FIXTURE. PROVIDE (2) 1 CONDUITS IN TRENCH AND STUB UP AT LOCATION SHOWN. PROVIDE A RECESSED FLUSH, 1 -GANG PLASTIC FLOOR BOX WITH 1 -GANG ALUMINUM FLANGE AND DUPLEX RECEPTACLE COVER PLATE. PROVIDE (1) DUPLEX RECEPTACLE IN BOX, HUBBELL -NO S1PFB BOX S1D1V1 DIVIDER, S1SP SUB -PLATE AND SICFCAL COVER. PROVIDE 2#12 AND 1#12 GROUND FROM ELECTRICAL PANEL. PROVIDE CONDUIT STUBBED 6" ABOVE CEILING, DOWN WALL AND COVER TO FLOOR FIXTURE. COORDINATE EXACT REQUIREMENTS WITH FIXTURE VENDOR. 5. TRENCH FLOOR TO LOCATION SHOWN FOR ROUTING OF POWER (P) AND CAT6 LOW VOLTAGE (LV) CABLING TO FLOOR FIXTURE. PROVIDE (2) 1" CONDUITS IN TRENCH AND STUB UP AT LOCATION SHOWN. PROVIDE AN EMT TO FLEX CONNECTOR AND FLEXIBLE METAL CONDUIT AT STUB UP LOCATION FOR CONNECTION TO PRE-INSTALLED J -BOX IN FLOOR FIXTURE. E.C. TO FURNISH AND INSTALL DUPLEX RECEPTACLE IN JBOX. PROVIDE 2#12 & 1#12 GROUND FROM ELECTRICAL PANEL, CIRCUIT AS INDICATED. PROVIDE CONDUIT STUBBED 6" ABOVE CEILING, DOWN WALL AND OVER TO FLOOR FIXTURE. COORDINATE EXACT REQUIREMENTS WITH FIXTURE VENDOR. 6. PROVIDE FIRE ALARM DEVICES AS INDICATED AND CONNECT TO EXISTING BUILDING FIRE ALARM SYSTEM. COORDINATE WITH LANDLORD FIRE ALARM CONTRACTOR. FIRE ALARM DEVICE LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL LOCATIONS NEED TO BE INSTALLED PER CODE AND ARE THE RESPONSIBILITY OF THE CONTRACTOR INSTALLING IT. MATCH EXISTING TYPE AND MANUFACTURER AS NECESSARY. REUSE/RELOCATE EXISTING DEVICES IF APPLICABLE. 7. AT EXPRESS PAY KIOSK PROVIDE THE FOLLOWING: •ONE (1) J -BOX FOR A DUPLEX RECEPTACLE MOUNTED HORIZONTALLY AT 4-1/2"A.F.F. TO BOTTOM OF J -BOX. •ONE (1) J -BOX FOR DATA MOUNTED HORIZONTALLY AT 4-1/2"A.F.F. TO BOTTOM OF J -BOX. PROVIDE A WHITE FACE PLATE WITH A 1"GROMMET CUT OUT FOR DATA J -BOX. PROVIDE (1) 6 -CONDUCTOR / 18 -GAUGE BARE WIRE AND (1) 2 -CONDUCTOR / 18 -GAUGE STRANDED WIRE FROM THIS LOCATION TO SECURITY PANEL. 8. DATA OUTLET CEILING MOUNTED FOR WIRELESS ACCESS POINT. COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE CAT6 LOW VOLTAGE CABLE FROM DEVICE TO SERVER RACK. 9. PROVIDE DATA JACK OUTLET CEILING MOUNTED FOR SHOPPER TRAK SYSTEM. PROVIDE CAT6 LOW VOLTAGE CABLE FROM DEVICE TO SERVER RACK. COORDINATE EXACT POWER REQUIREMENTS PRIOR TO BID AND ROUGH -IN. 10. AT WALL COAX JACKS PROVIDE PLASTER RING AND STEEL COMMUNICATION MOUNTING BRACKET. PROVIDE RG6 COAXIAL CABLE TO SERVER RACK. COAX CABLE TO BE INSTALLED ON PLYWOOD BEHIND SERVER RACK. QUANTITY AS NOTED. 11. AT THE WALL DATA DEVICES PROVIDE PLASTER RING AND STEEL COMMUNICATION MOUNTING BRACKET. PROVIDE LOW VOLTAGE CAT6 CABLES TO EACH LOCATION AS INDICATED. PROVIDE LOW VOLTAGE CABLE FROM DEVICE TO COMCAST SERVER RACK. SEE CABLE SCHEDULE ON THIS SHEET FOR CABLE TYPE. QUANTITY AS NOTED. COORDINATE EXACT REQUIREMENTS WITH FIXTURE VENDOR. 12. EXISTING ELECTRICAL PANEL "L1" RECESSED IN STORAGE AREA TO REMAIN. PROVIDE NEW CIRCUIT BREAKERS AS REQUIRED. MATCH EXISTING EQUIPMENT TYPE AND AIC RATING. FIELD VERIFY EXACT AVAILABLE LOADS AND SPACE IN EXISTING PANEL PRIOR TO BID AND INSTALLATION. 13. PROVIDE J -BOX AND DISCONNECTING MEANS IN ACCESSIBLE LOCATION FOR CONNECTION TO ILLUMINATED EXTERIOR SIGNAGE. COORDINATE EXACT REQUIREMENTS WITH SIGN VENDOR. PROVIDE CONDUIT WITH PULL STRING FROM ELECTRIC PANEL INDICATED TO SIGNAGE J -BOX. SIGN CIRCUIT TO BE CONTROLLED BY EXISTING TIME CLOCK (TC1). RE -USE EXISTING CIRCUITRY IF APPLICABLE. XR = EXISTING TO BE REMOVE. EX = EXISTING TO REMAIN. ,' — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J POWER AND LOW VOLTAGE PLAN 1/4" = 1'-0" I, Ryan J. Lindahl certify that this plan Specification, or report was prepared by me or Under my direct supervision, and that I am a duly Licensed Engineer under the laws of the State of Massachusetts. 5W Preliminary Issue: Q9/06/2019 Bid Issue: 09/10/2019 Landlord Issue: 09/10/2019 Permit Issue: 09/10/2019 i� 09/10/2019 co Z N 111 U W � U_ 0 Ldp Uj 05 O r1r.1�.1 vJ Z) O W <C 0 >_ U o= :D 00 U T- 0 5W Preliminary Issue: Q9/06/2019 Bid Issue: 09/10/2019 Landlord Issue: 09/10/2019 Permit Issue: 09/10/2019 Construction Issue 09/10/2019 ELECTRICAL SYMBOL LEGEND, 'OWER SND LOW VOLTAGE PLAN Comm. Number R19-3627.012 Date 09/10/2019 Drawn By Checked By CTC DJQ/PJF E1.0 16010 - GENERAL PROVISIONS A. WORK CONSISTS OF FURNISHING LABOR, MATERIALS, EQUIPMENT AND SERVICES REQUIRED FOR THE COMPLETE INSTALLATION OF ELECTRICAL WORK SHOWN IN THE CONTRACT DOCUMENTS AND SPECIFIED IN DIVISION 16. B. INCLUDE ALL PARTS AND LABOR, WHICH ARE INCIDENTAL AND NECESSARY FOR A COMPLETE AND OPERABLE INSTALLATION EVEN THOUGH NOT SPECIFICALLY MENTIONED IN THE CONTRACT DOCUMENTS. SUCH ITEMS INCLUDE NUTS, BOLTS, ANCHORS, BRACKETS, SLEEVES, OFFSETS IN CONDUIT, FITTINGS, RELAYS, ETC. C. ARRANGE WITH LANDLORD TO PROVIDE TEMPORARY AND PERMANENT UTILITY SERVICES AS REQUIRED AND COORDINATE THEIR INSTALLATION WITH CONSTRUCTION PROGRESS OF THIS PROJECT. PAY ALL FEES AND COSTS CHARGED BY UTILITY COMPANIES FOR UTILITY SERVICES. D. OBTAIN ALL TEMPORARY AND PERMANENT PERMITS AND LICENSES REQUIRED IN CONNECTION WITH THIS DIVISION'S WORK. PAY ALL FEES AND EXPENSES REQUIRED FOR SUCH PERMITS AND LICENSES. E. REQUEST INSPECTIONS AS REQUIRED BY REGULATING AGENCIES AND/OR REGULATIONS. PAY ALL CHARGES FOR INSPECTIONS BY REGULATING AGENCIES OF INSTALLATIONS OF PLANS AND SPECIFICATIONS. F. INCLUDE STATE AND LOCAL SALES TAXES IN THE BID. KEEP ACCURATE RECORDS OF THESE TAXES AND FURNISH SUCH RECORDS TO THE TENANT UPON REQUEST. G. MEET OR EXCEED ALL CURRENT APPLICABLE CODES, ORDINANCES AND REGULATIONS FOR ALL INSTALLATIONS. PROMPTLY NOTIFY THE ENGINEER, IN WRITING, IF THE CONTRACT DOCUMENTS APPEAR TO CONFLICT WITH GOVERNING CODES AND REGULATIONS. CONTRACTOR ASSUMES ALL RESPONSIBILITY AND COSTS FOR CORRECTING NON -COMPLYING WORK INSTALLED WITHOUT NOTIFYING THE ENGINEER. H. HIGHER QUALITY OF WORKMANSHIP AND MATERIALS INDICATED IN THE CONTRACT DOCUMENTS TAKES PRECEDENCE OVER THAT ALLOWED IN REFERENCED CODES AND STANDARDS. 1. THE TERMS DEFINED BELOW APPLY TO ALL WORK INCLUDED IN DIVISION 16. 1. THE WORK - AS DEFINED IN THE 1997 AIA DOCUMENT A201: "THE TERM 'WORK' MEANS THE CONSTRUCTION AND SERVICES REQUIRED BY THE CONTRACT DOCUMENTS WHETHER COMPLETED OR PARTIALLY COMPLETED, AND INCLUDES ALL OTHER LABOR, MATERIALS, EQUIPMENT AND SERVICES PROVIDED OR TO BE PROVIDED BY THE CONTRACTOR TO FULFILL THE CONTRACTOR'S OBLIGATIONS. THE WORK MAY CONSTITUTE THE WHOLE OR A PART OF THE PROJECT." 2. FURNISH - TO OBTAIN IN NEW CONDITION READY FOR INSTALLATION INTO THE WORK. 3. INSTALL - TO STORE, SET IN PLACE, CONNECT AND PLACE INTO OPERATION INTO THE WORK. 4. PROVIDE - TO FURNISH AND INSTALL. 5. CONNECT - TO BRING SERVICE TO THE EQUIPMENT AND MAKE FINAL ATTACHMENT INCLUDING NECESSARY SWITCHES, OUTLETS, BOXES, TERMINATIONS, ETC, 6. CONDUIT - INCLUDES IN ADDITION TO CONDUIT, ALL FITTINGS, PULL BOXES, HANGERS AND OTHER SUPPORTS AND ACCESSORIES RELATED TO SUCH CONDUIT. 7. CONCEALED - HIDDEN FROM SIGHT IN CHASES, FURRED SPACES, SHAFTS, HUNG CEILINGS, EMBEDDED IN CONSTRUCTION, IN CRAWL SPACES OR BURIED. 8. EXPOSED: NOT INSTALLED UNDERGROUND NOR CONCEALED AS DEFINED ABOVE. J. THE DRAWING AND SPECIFICATIONS CONSTITUTE THE CONTRACT DOCUMENTS. ANY ITEM NOTED IN THE SPECIFICATION OR SHOWN ON THE DRAWINGS IS INCLUDED IN THE CONTRACT DOCUMENTS. K. ALL ELECTRICAL DETAILS AND DRAWINGS ARE DIAGRAMMATIC, UNLESS SPECIFICALLY NOTED. FIELD VERIFY ALL DIMENSIONS AND NOTIFY THE ENGINEER OF ANY CONFLICTS OR DISCREPANCIES, IN WRITING, PRIOR TO INSTALLATION. L. INITIATE, MAINTAIN AND SUPERVISE ALL SAFETY PRECAUTIONS REQUIRED WITH THIS WORK IN ACCORDANCE WITH THE REGULATIONS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) AND OTHER GOVERNING AGENCIES. M. DO NOT REMOVE OR DISTURB ANY ASBESTOS CONTAINING MATERIALS FROM THE PROJECT. IMMEDIATELY STOP WORK AND NOTIFY THE TENANT IF ASBESTOS CONTAINING MATERIALS ARE SUSPECTED. N. BEFORE SUBMITTING A PROPOSAL ON THE WORK CONTEMPLATED, EXAMINE THE SITE OF THE PROPOSED WORK AND BECOME THOROUGHLY FAMILIAR WITH EXISTING CONDITIONS AND LIMITATIONS. NO EXTRA COMPENSATION WILL BE ALLOWED BECAUSE OF MISUNDERSTANDING AS TO THE AMOUNT OF WORK INVOLVED NOR BIDDERS LACK OF KNOWLEDGE OF EXISTING CONDITIONS WHICH COULD HAVE BEEN DISCOVERED OR REASONABLY ANTICIPATED PRIOR TO BIDDING. 0. CONDUITS, PIPES, DUCTS, LIGHTS, DEVICES, SPEAKERS, ETC., SHOWN ON THE DRAWINGS AS EXISTING HAVE BEEN BASED ON EXISTING PLANS AND MAY NOT BE INSTALLED AS ORIGINALLY SHOWN. IT IS THE CONTRACTORS RESPONSIBILITY TO VISIT THE SITE AND MAKE EXACT DETERMINATION OF THE EXISTENCE, LOCATION AND CONDITION OF SUCH FACILITIES PRIOR TO SUBMITTING A BID. P. CONSULT THE DRAWINGS AND SPECIFICATIONS OF MECHANICAL AND OTHER TRADES FOR CORRELATING INFORMATION AND LAY OUT WORK SO THAT IT WILL COORDINATE WITH OTHER TRADES. VERIFY DIMENSIONS AND CONDITIONS (I.E., FINISHED CEILING HEIGHTS, FOOTING AND FOUNDATION ELEVATIONS, BEAM DEPTHS, ETC.) WITH THE ARCHITECTURAL AND STRUCTURAL DRAWINGS. NOTIFY THE ARCHITECT/ENGINEER OF ANY CONFLICTS THAT CANNOT BE RESOLVED, IN THE FIELD, BY AFFECTED TRADES. REPLACEMENT OF WORK DUE TO LACK OF COORDINATION AND FAILURE TO VERIFY EXISTING CONDITIONS WILL BE COMPLETED AT NO COST TO THE TENANT. Q. INSTALL ALL CONDUIT, CABLE TRAY, BUSDUCT, EQUIPMENT, ETC. ALLOWING PROPER CODE AND MAINTENANCE CLEARANCES AND TO AVOID BLOCKING PASSAGEWAYS AND ACCESS PANELS. R. WHERE WORK MUST BE REPLACED DUE TO THE FAILURE OF THE CONTRACTOR TO VERIFY THE CONDITIONS EXISTING ON THE JOB, SUCH REPLACEMENT MUST BE ACCOMPLISHED AT NO COST TO THE TENANT. THIS APPLIES TO SHOP FABRICATED WORK AS WELL AS TO WORK FABRICATED IN PLACE. S. THROUGHOUT THE COURSE OF THE WORK, MINOR CHANGES AND ADJUSTMENTS TO THE INSTALLATION MAY BE REQUESTED BY THE ENGINEER. THE CONTRACTOR SHALL MAKE ADJUSTMENTS WITHOUT ADDITIONAL COST TO THE TENANT, WHERE SUCH ADJUSTMENTS ARE NECESSARY TO THE PROPER INSTALLATION AND OPERATION WITHIN THE INTENT OF THE CONTRACT DOCUMENTS. THIS DOES NOT INCLUDE WORK ALREADY COMPLETED. T. OBTAIN EXACT LOCATION OF CONNECTION TO EQUIPMENT, FURNISHED BY OTHERS, FROM THE PERSON FURNISHING THE EQUIPMENT. U. DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WHAT IS CALLED FOR IN EITHER ONE IS AS BINDING AS IF CALLED FOR IN BOTH. V. INCLUDE THE BETTER QUALITY, GREATER QUANTITY OR HIGHER COST FOR AN ITEM OR ARRANGEMENT WHERE A DISAGREEMENT EXISTS IN THE DRAWINGS AND SPECIFICATIONS. W. GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION FOR THE PERIOD OF ONE (1) YEAR AFTER THE FINAL COMPLETION OF THE WORK AS EVIDENCED BY ISSUANCE OF THE FINAL CERTIFICATE BY THE ARCHITECT. X. DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE MENTIONED PERIOD MUST BE IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF THE TENANT AND ARCHITECT AND ENGINEER. INCLUDE DAMAGE TO THE FINISH OR THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIRS. Y. REPLACE ALL RECEPTACLES, SWITCHES, COVERPLATES, ETC.. DAMAGED BY ANY CONTRACTOR DURING THE COURSE OF CONSTRUCTION. Z. MATERIALS FURNISHED FOR THE TEMPORARY LIGHT AND POWER SYSTEM REMAIN CONTRACTORS PROPERTY. REMOVE WHEN THERE IS NO LONGER ANY NEED FOR TEMPORARY LIGHT AND POWER OR WHEN DIRECTED BY THE ARCHITECT.. AA. COORDINATE/SCHEDULE ALL WORK WITH THE TENANT TO MINIMIZE ANY DISRUPTIONS. CONFINE ALL INTERRUPTIONS TO THE SMALLEST POSSIBLE AREA. PROVIDE TEMPORARY CONNECTIONS IF REQUIRED TO PROVIDE CONTINUITY OF SERVICE. BB. INSPECT ALL AREAS AFFECTED BY THE INTERRUPTIONS AND RETURN ALL AUTOMATICALLY CONTROLLED EQUIPMENT, ELECTRICALLY OPERATED EQUIPMENT TO THE SAME OPERATING CONDITION PRIOR TO THE INTERRUPTION. CC. NO FIRE ALARM SYSTEMS ARE TO REMAIN INACTIVE AT THE END OF THE WORK DAY. ASSURE THAT THE FIRE ALARM SYSTEM IS OPERATIONAL RATIONAL AT THE END OF EACH WORK DAY. COORDINATE WITH THE LANDLORD. DD. DO NOT DISTURB NORMAL USE OF THE FACILITY, EXCEPT WITHIN THE IMMEDIATE CONSTRUCTION AREA. KEEP WALKS, DRIVEWAYS, ENTRANCES, ETC. FREE AND CLEAR OF EQUIPMENT, MATERIAL AND DEBRIS. EE. STORE ALL EQUIPMENT AND MATERIAL IN A PLACE AND MANNER THAT MINIMIZES CONGESTION AND IS APPROVED BY THE TENANT. FF. PROVIDE NEW MATERIAL AND EQUIPMENT, UNLESS NOTED OTHERWISE. PROTECT EQUIPMENT AND MATERIAL FROM DAMAGE, DIRT AND THE WEATHER. GG. PROVIDE THE HIGHEST QUALITY WORKMANSHIP AND PERFORM ALL WORK ONLY BY SKILLED MECHANICS. INSTALL MATERIAL AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS, INSTRUCTIONS AND CURRENT NECA STANDARDS. HH. THE TENANT RESERVES THE RIGHT TO REJECT MATERIAL OR WORKMANSHIP NOT IN ACCORDANCE WITH THE SPECIFICATIONS, BEFORE OR AFTER INSTALLATION. II. PERFORM ALL CUTTING AND PATCHING NECESSARY TO WORK, UNLESS SPECIFICALLY DELEGATED TO THE GENERAL CONTRACTOR. OBTAIN SPECIAL PERMISSION FROM THE LANDLORD BEFORE CUTTING STRUCTURAL MEMBERS OR FINISHED MATERIAL. PERFORM ALL PATCHING IN SUCH A MANNER AS TO LEAVE NO VISIBLE TRACE AND RETURN THE AREA AFFECTED TO THE CONDITION OF UNDISTURBED WORK. PERFORM ALL PATCHING BY WORKERS EXPERIENCED, SKILLED, AND LICENSED FOR THE PARTICULAR TYPE OF WORK INVOLVED. INFERIOR WORK WILL NOT BE ACCEPTED. JJ. PATCH ALL HOLES LEFT AS A RESULT OF DEMOLITION OF ELECTRICAL EQUIPMENT AND DEVICES. KK. PREVENT THE SPREAD OF DUST, DEBRIS, AND OTHER MATERIAL INTO ADJACENT AREAS. LL. REPLACE ALL CEILING TILES DAMAGED DURING INSTALLATION OF WORK, WITH NEW TILE. MM. PROVIDE MINIMUM 4" HIGH CONCRETE PADS FOR ALL FLOOR MOUNTED EQUIPMENT. NN. SIZE PAD TO PROVIDE A MINIMUM 2" OVERLAP AROUND PERIMETER OF EQUIPMENT. 00. REFINISH ALL ELECTRICAL EQUIPMENT DAMAGED DURING SHIPPING AND/OR INSTALLATION TO ITS ORIGINAL CONDITION. REMOVE ALL RUST; PRIME, AND PAINT PER MANUFACTURER'S RECOMMENDATIONS FOR FINISH EQUAL TO ORIGINAL. PP. PAINT ALL NEW RACEWAY SYSTEMS IN EXPOSED FINISHED AREAS . 00. AFTER TESTS HAVE BEEN MADE AND ACCEPTED, CLEAN LIGHT FIXTURES, PANELS AND OTHER EQUIPMENT INSTALLED BY THE CONTRACTOR, LEAVING THE EN11RE WORK AREA IN A CLEAN AND COMPLETE WORKING ORDER. RR. OPERATE EQUIPMENT AND SYSTEMS IN ALL THEIR OPERATING MODES, TO VERIFY PROPER OPERATION, PRIOR TO FINAL INSPECTION AND OWNER INSTRUCTIONS. NOTIFY THE ENGINEER, IN WRITING, THAT ALL SYSTEMS HAVE BEEN TESTED AND ARE FUNCTIONING AND OPERATING PROPERLY SS. INCLUDE DOCUMENTATION OF INSTRUCTIONS IN THE OPERATION AND MAINTENANCE MANUALS. TT. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ELECTRICAL EQUIPMENT OR MATERIALS UNTIL FINAL ACCEPTANCE OF THE ENTIRE PROJECT BY THE TENANT. KEEP ALL EQUIPMENT CLEAN MATERIALS UNTIL FINAL ACCEPTANCE OF THE ENTIRE PROJECT BY THE TENANT. 16025 - DEMOLITION A. EXAMINE THE BUILDING TO DETERMINE ACTUAL CONDITIONS AND EXTENT OF WORK PRIOR TO BIDDING THE PROJECT. REFER ANY UNCLEAR DETAILS OR CONFLICTS TO THE ARCHITECT/ENGINEER FOR CLARIFICATION PRIOR TO BIDDING THE DRAWINGS. B. VERIFY THAT FIELD MEASUREMENTS AND CIRCUITING ARRANGEMENTS ARE AS SHOWN OF DRAWINGS. C. VERIFY THAT ABANDONED WIRING AND EQUIPMENT SERVE ONLY ABANDONED FACILITIES. D. BEGINNING OF DEMOLITION MEANS INSTALLER ACCEPTS EXISTING CONDITIONS. E. COORDINATE PHASING OF THE DEMOLITION WORK WITH THE CONSTRUCTION SEQUENCE SCHEDULE. F. DISCONNECT ELECTRICAL SYSTEMS IN WALLS, FLOORS, AND CEILINGS SCHEDULED FOR REMOVAL. G. COORDINATE UTILITY SERVICE OUTAGES WITH LANDLORD. H. IDENTIFY EXISTING ELECTRICAL EQUIPMENT SUCH AS CONDUITS, BOXES, PULLBOXES, CONDUIT BODIES, AND CONDUIT RACKS THAT WILL NEED ADDITIONAL SUPPORT DUE TO THE DEMOLITION OF THE EXISTING SUPPORTS. 1. PROVIDE TEMPORARY WIRING AND CONNEC11ONS TO MAINTAIN EXISTING SYSTEMS, INCLUDING TELEPHONE AND DATA SYSTEMS, IN SERVICE DURING CONSTRUCTION. WHEN WORK MUST BE PERFORMED ON ENERGIZED EQUIPMENT OR CIRCUITS, USE PERSONNEL EXPERIENCED IN SUCH OPERATIONS. J. EXISTING ELECTRICAL SERVICE: MAINTAIN EXISTING SYSTEM IN SERVICE UNTIL NEW SYSTEM IS COMPLETE AND READY FOR SERVICE. DISABLE SYSTEM ONLY TO MAKE SWITCHOVERS AND CONNECTIONS. NOTIFY AND OBTAIN PERMISSION FROM TENANT, ARCHITECT/ENGINEER AT LEAST 24 HOURS BEFORE PARTIALLY OR DISABLING SYSTEM. MINIMIZE OUTAGE DURATION. MAKE TEMPORARY CONNECTIONS TO MAINTAIN SERVICE IN AREAS ADJACENT TO WORK AREA, K. EXISTING FIRE ALARM SYSTEM: MAINTAIN EXISTING SYSTEM IN SERVICE UNTIL NEW SYSTEM IS ACCEPTED. DISABLE SYSTEM ONLY TO MAKE SWITCHOVERS AND CONNECTIONS. NOTIFY AND OBTAIN PERMISSION FROM LANDLORD, ARCHITECT/ENGINEER AND LOCAL FIRE SERVICE AT LEAST 24 HOURS BEFORE PARTIALLY OR COMPLETELY DISABLING SYSTEM. MINIMIZE OUTAGE DURATION. MAKE TEMPORARY CONNECTIONS TO MAINTAIN SERVICE IN AREA ADJACENT TO WORK AREA. L. EXISTING TELEPHONE/DATA SYSTEM: MAINTAIN EXISTING SYSTEMS IN SERVICE UNTIL NEW SYSTEMS ARE COMPLETE AND READY FOR SERVICE AND ACCEPTED. DISABLE SYSTEMS ONLY TO MAKE SWITCHOVERS AND CONNECTIONS. NOTIFY AND OBTAIN PERMISSION FROM LANDLORD, ARCHITECT/ENGINEER AND TELEPHONE UTILITY COMPANY AT LEAST 24 HOURS BEFORE PARTIALLY OR COMPLETELY DISABLING SYSTEM. MINIMIZE OUTAGE DURATION. MAKE TEMPORARY CONNECTIONS TO MAINTAIN SERVICE IN AREAS ADJACENT TO WORK AREA. M. DEMOLISH AND EXTEND EXISTING ELECTRICAL WORK UNDER AND THIS SECTION, AND AS INDICATED ON THE DRAWINGS. REMOVE, RELOCATE, AND EXTEND EXISTING INSTALLATIONS TO ACCOMMODATE NEW CONSTRUCTION. N. PROVIDE SUPPORTS FOR ALL EXISTING ELECTRICAL EQUIPMENT THAT WAS SUPPORTED PREVIOUSLY BY DEMOLISHED WALLS, FLOORS, CEILING OR OTHER STRUCTURES. PROVIDE NEW SUPPORTS FROM STRUCTURAL MEMBERS NOT SLATED FOR DEMOLITION, PRIOR TO ANY DEMOLITION. O. TENANT RESERVES THE RIGHT OF FIRST REFUSAL TO OBTAIN MATERIAL SHOWN TO BE REMOVED UNDER THIS CONTRACT. ITEMS NOT RETAINED BY THE TENANT BECOME THE PROPERTY OF THE CONTRACTOR AND MUST BE REMOVED FROM THE PREMISES. P. DEMOLISH AND REMOVE ALL ELECTRICAL SYSTEMS INDICATED FOR DEMOLITION. NO PORTION OF THESE SYSTEMS MAY BE ABANDONED IN PLACE. Q. REMOVE ABANDONED WIRING TO SOURCE OF SUPPLY. R. REMOVE EXPOSED ABANDONED CONDUIT, INCLUDING ABANDONED CONDUIT ABOVE ACCESSIBLE CEILING FINISHES. CUT CONDUIT IN WALLS, FLOORS, OR COLUMNS BACK TO A POINT WHERE PATCHING CAN BE ADEQUATELY PERFORMED AND PATCH SURFACES. S. DISCONNECT ABANDONED OUTLETS AND REMOVE DEVICES. REMOVE ABANDONED OUTLETS IF CONDUIT SERVICING THEM IS ABANDONED AND REMOVED. PROVIDE BLANK COVER FOR ABANDONED OUTLETS, WHICH ARE NOT REMOVED. T. DISCONNECT AND REMOVE ABANDONED PANELBOARDS AND DISTRIBUTION EQUIPMENT. U. DISCONNECT AND REMOVE ELECTRICAL DEVICES AND EQUIPMENT SERVING UTILIZATION EQUIPMENT THAT HAS BEEN REMOVED. V. DISCONNECT AND REMOVE -ABANDONED LUMINARIES. REMOVE BRACKETS, STEMS, HANGERS, AND OTHER ACCESSORIES. W. REPAIR ADJACENT CONSTRUCTION AND FINISHES DAMAGED DURING DEMOLITION AND EXTENSION WORK. X. MAINTAIN ACCESS TO EXISTING ELECTRICAL INSTALLATIONS, WHICH REMAIN ACTIVE. MODIFY INSTALLATION OR PROVIDE ACCESS PANEL AS APPROPRIATE. Y. EXTEND EXISTING INSTALLATIONS USING MATERIALS AND METHODS COMPATIBLE WITH EXISTING ELECTRICAL INSTALLATIONS, OR AS SPECIFIED. RELOCATE AND REROUTE CONDUIT AND WIRING AS REQUIRED FOR CONDUIT CONCEALED IN WALLS OR STRUCTURE BEING ALTERED AS PART OF THE REMODELING. MAINTAIN CONTINUITY TO ALL DEVICES IN AND DOWNSTREAM OF REMODELED WORK. Z. REROUTE EXISTING RACEWAY AND WIRING, WHICH IS EXPOSED DUE TO REMOVAL OF EXISTING CONSTRUCTION, CONCEAL NEW RACEWAY AND WIRING AND MAINTAIN OPERATION. AA. IF CONDUCTORS ARE REQUIRED TO BE REMOVED FROM EXISTING RACEWAYS, INSTALL WITH NEW CONDUCTORS. BB. PROVIDE NEW COVERPLATES THROUGHOUT THE REMODELED AREAS. CC. DISPOSE OF FLUORESCENT LAMPS, BALLASTS, AND OTHER HAZARDOUS MATERIALS IN ACCORDANCE WITH STATE AND FEDERAL REGULATIONS. DD. PRIOR TO REINSTALLATION OF USED EQUIPMENT, THOROUGHLY INSPECT EACH ITEM AND REPORT ANY DEFECTS TO THE ENGINEER/ARCHITECT IN WRITING, INSTRUCTIONS FOR CORRECTIVE MEASURES WILL BE GIVEN AT THE TIME AND THE CONTRACT AMOUNT ADJUSTED ACCORDINGLY. IF NO DEFECTS ARE REPORTED, THE MATERIAL WILL BE INCLUDED UNDER THE CONTRACTOR'S ONE-YEAR GUARANTEE AS OUTLINED IN SECTION 16010. EE, PANELBOARDS: CLEAN EXPOSED SURFACES AND CHECK TIGHTNESS OF ELECTRICAL CONNECTIONS. REPLACE DAMAGED CIRCUIT BREAKERS AND PROVIDE CLOSURE PLATES FOR VACANT POSITIONS. PROVIDE TYPED CIRCUIT DIRECTORY SHOWING REVISED CIRCUITING ARRANGEMENT. FF. LUMINARIES: REMOVE EXISTING LUMINARIES FOR CLEANING. USE MILD DETERGENT TO CLEAN ALL EXTERIOR AND INTERIOR SURFACES; RINSE WITH CLEAN WATER AND WIPE DRY. REPLACE LAMPS, BALLASTS, AND BROKEN ELECTRICAL PARTS. GG. INSTALL RELOCATED MATERIALS AND EQUIPMENT AS INDICATED ON THE DRAWINGS. 16050 - BASIC MATERIALS AND METHODS A. PROVIDE SEPARATE NEUTRAL CONDUCTORS FOR ALL BRANCH CIRCUITS. DO NOT SHARE NEUTRAL CONDUCTORS. B. ENCASE ALL CONDUCTORS IN A CONTINUOUS RACEWAY SYSTEM. PROVIDE PULL AND JUNCTION BOXES AS REQUIRED BY THE NEC. SIZE ALL RACEWAY PER THE NEC WITH OVERSIZE CONDUITS AS INDICATED. PROVIDE MINIMUM 3/4" CONDUIT FOR BRANCH CIRCUIT HOMERUNS, PROVIDE MINIMUM 1/2" CONDUIT, UNLESS, NOTED OTHERWISE. C. PROVIDE EMT FOR ALL CONDUCTORS UNLESS NOTED OTHERWISE. PROVIDE CONCRETE -TIGHT STEEL COMPRESSION OR STEEL SETSCREW TYPE FITTINGS, COUPLINGS AND BUSHINGS. CAST OR INDENTOR TYPE DEVICES ARE NOT ACCEPTABLE. ALL FITTINGS USED IN PLENUM APPLICATIONS SHALL BE RATED FOR SUCH USE. D. PROVIDE IMC OR CONCRETE -ENCASED PVC CONDUIT FOR SERVICE ENTRANCE CONDUCTORS. E. PVC CONDUIT MAY BE USED UNDERGROUND OR BELOW CONCRETE SLABS. PROVIDE COATED RIGID STEEL ELBOWS FOR ALL ELBOWS WHERE PVC IS USED. F. PROVIDE FLEXIBLE METAL CONDUIT FOR CONNECTIONS TO TRANSFORMERS, MOTORS AND OTHER VIBRATING PIECES OF EQUIPMENT. PROVIDE LIQUID -TIGHT CONDUIT FOR ALL CONNECTIONS IN DAMP OR WET LOCATIONS. PROVIDE GROUND TYPE FITTINGS AND GROUNDING CONDUCTOR INSIDE ALL FLEXIBLE CONDUIT. ADJUST CONDUIT SIZE IF REQUIRED. G. PROVIDE RECESSED OUTLET BOXES AND JUNCTION BOXES IN ALL NEW CONSTRUCTION. CONCEAL ALL CONDUIT WORK IN NEW CONSTRUCTION, EXCEPT MECHANICAL ROOMS. CONDUIT AND BOXES IN MECHANICAL ROOMS MAY BE RUN EXPOSED. H. PROVIDE EXPANSION FITTINGS WHERE RACEWAY CROSSES BUILDING EXPANSION JOINTS. L RUN ALL EXPOSED CONDUIT IN A NEAT, WORKMANLIKE MANNER PARALLEL TO THE BUILDING LINES, TIGHT TO THE WALL TNG SURFACES AND FIRMLY SUPPORT WITH CONDUIT CLAMPS OR LL AND CEILING ERS. PROVIDE TWO 2 HOLE MOUNTING STRAPS MINIMUM THREE 3 FEET ON CENTER FOR HANG ( ) ALL SURFACE CONDUIT MOUNTED ON WALLS LESS THAN SIX (6) FEET ABOVE FINISHED FLOOR. PLACE CONDUITS AT LEAST 8" AWAY FROM ALL HOT PIPING AND SURFACES INCLUDING DOMESTIC HOT WATER LINES. J. PROVIDE GALVANIZED CODE GAUGE STEEL JUNCTION AND PULL BOXES WITH SCREW ON COVERS OF TYPE, SHAPE AND SIZE REQUIRED TO SUIT EACH INSTALLATION. PROVIDE GASKETING IN DAMP AND DUSTY LOCATIONS. PROVIDE CAST BOXES IN WEATHERPROOF, VAPOR TIGHT AND EXPLOSION PROOF ENVIRONMENTS. K. PROVIDE 4" BOXES THROUGHOUT. PROVIDE 3 1/2" DEEP BOXES WHERE INSTALLED IN MASONRY, 2 1/2" MINIMUM ELSEWHERE. PROVIDE SINGLE GANG MUD OR TILE RING FOR SINGLE DEVICES. L. MOUNT OUTLETS BOXES IN EXPOSED MASONRY WALLS WITH THE BOTTOM OF THE BOX ON THE TOP OF THE MORTAR JOINT AND THE VERTICAL LINE OF THE BOX EITHER ON THE MORTAR JOINT OR ON THE CENTER LINE OF THE MASONRY UNIT. PLUMB AND ACCURATELY ALIGN ALL WALL OUTLETS IN ROWS. MOUNT CEILING BOXES SYMMETRICAL WITH WALLS, BEAMS AND/OR TILES. MOUNTING HEIGHTS INDICATED ON THE DRAWINGS ARE FROM THE CENTER OF THE OUTLET BOX TO THE FINISHED FLOOR DIRECTLY BELOW THE OUTLET. EXTERIOR HEIGHTS ARE FROM INSIDE ADJACENT DOOR, OR IF NO DOOR, FROM THE FIRST FLOOR ABOVE GRADE, UNLESS NOTED OTHERWISE. M. COORDINATE THE LOCATION OF ALL OUTLETS WITH ARCHITECTURAL AND MECHANICAL DRAWINGS BEFORE INSTALLATION. COORDINATE ALL DOOR SWINGS IN THE FIELD BEFORE LOCATING SWITCHES. N. PROVIDE NEW WIRING DEVICES IN EACH OUTLET INDICATED ON THE DRAWINGS. PROVIDE ALL DEVICES FROM ONE MANUFACTURER. COLOR TO MATCH ADJACENT SURFACE. 0. APPROVED TOGGLE SWITCH MANUFACTURERS/MODEL NUMBERS: MFR. PROVIDE NEW COVERPLATES OVER ALL BOXES WITH THE FOLLOWING SPECIFICATIONS: ALL FINISHED 16500 20A 120-277 WALL SWITCHES MFR. SIMPLEX 1 -POLE 1 -POLE 2 -POLE 3 -WAY 4 -WAY KEYED W/PILOT 1 POLE MOM. CONTACT COOPER 2221 2221PL 2222 2223 2224 2221L 1995 HUBBELL HBL1221 HBL1221PL HBL1222 HBL1223 HBL1224 HBL1221L HBL1557 P&S PS20AC1 PS20AC1-RL PS20AC2 PS20AC3 PS20AC4 PS20AC1-L 1251 LEVITON 1221-2 1221-2PL 1222-2 1223-2 1224-2 1 1221-2L 1257 P. APPROVED STANDARD RECEPTACLE MANUFACTURERS/MODEL NUMBERS: *PROVIDE THE CORRESPONDING HOSPITAL GRADE DEVICE WHEN THIS DEVICE IS USED. Q. PROVIDE NEW COVERPLATES OVER ALL BOXES WITH THE FOLLOWING SPECIFICATIONS: ALL FINISHED 16500 20A 125V STANDARD RECEPTACLES Permit Issue: MFR. SIMPLEX DUPLEX GFI IG TVSS TAMPER RESISTANT COOPER 5361 5362 XGF20 IG536-2 53625 TR8300 HUBBELL HBL536-1 HBL536-2 GFR5352-A IG536-2 HBL5360SA HBL8300SC A P & S 5361 5362A OR PT5362-A 2094 IG630-0 8300SP TR63H LEVITON 5361 5362 1 8899 1 5362 -IG 7380 1 8300 -SG *PROVIDE THE CORRESPONDING HOSPITAL GRADE DEVICE WHEN THIS DEVICE IS USED. Q. PROVIDE NEW COVERPLATES OVER ALL BOXES WITH THE FOLLOWING SPECIFICATIONS: ALL FINISHED 16500 - LIGHTING Permit Issue: AREAS AND UNFINISHED AREAS PROVIDE PLASTIC COVERS, COLOR TO MATCH ADJACENT SURFACE A. COMPLY WITH NEC AS APPLICABLE TO THE INSTALLATION AND CONSTRUCTION OF LIGHT FIXTURES. OR AS SELECTED BY THE ARCHITECT. PROVIDE APPROPRIATE COVERS OVER SPECIAL PURPOSE S. COMPLY WITH IBC AS APPLICABLE TO THE INSTALLATION AND CONSTRUCTION OF LIGHT FIXTURES. RECEPTACLES. PROVIDE NEW WEATHERPROOF COVERPLATES FOR OUTLETS AND SWITCHES AS C. PROVIDE LIGHT FIXTURES THAT ARE LISTED AND LABELED BY U.L. OR ANOTHER NATIONALLY INDICATED ON THE DRAWINGS AND FOR ALL EXTERIOR DEVICES. RECOGNIZED TESTING LABORATORY FOR THE APPLICATION. R. PROVIDE WIRE AND CABLE WITH INSULATION VOLTAGE RATING EQUAL TO OR GREATER THAN THE D. COMPLY WITH ALL LOCAL, STATE AND FEDERAL ENERGY CODES. APPLIED SYSTEM VOLTAGE. PROVIDE SOLID OR STRANDED COPPER CONDUCTORS WITH TYPE THWN, E. PROVIDE FIXTURES WITH LAMPS, FOR EACH OUTLET SHOWN ON THE DRAWINGS AND AS SPECIFIED THHN, OR XHHN INSULATION FOR NO. 12 AWG AND NO. 10 AWG CONDUCTORS. PROVIDE STRANDED HEREIN. SEE FIXTURES UST ON THE PLAN. COPPER CONDUCTORS WITH TYPE THWN, THHN, OR XHHW INSULATION FOR NO. 8 AWG AND F. PROVIDE SOLID STATE, SLIDE -TYPE DIMMERS SUITABLE FOR MOUNTING BEHIND A STANDARD DEPTH LARGER CONDUCTORS. PROVIDE MINIMUM NO. 12 AWG CONDUCTOR SIZE, UNLESS NOTED FACEPLATE AND FOR OPERATION ON COMMON NEUTRAL CIRCUITS. OTHERWISE. USE THE MINIMUM CONDUCTOR SIZE WHEN NO SIZE IS INDICATED. ALL CONDUCTORS 1. PROVIDE 600 WATTS CAPACITY PER DIMMER UNLESS NOTED OTHERWISE ON THE PLANS. TO BE COLOR -CODED AS FOLLOWS;120/208 VOLT SYSTEMS -PHASE A(BLACK), PHASE B(RED), 2. ACCEPTABLE MANUFACTURERS: PHASE C(BLUE), NEUTRAL(WHITE). 277/480 VOLT SYSTEMS -PHASE A(BROWN), PHASE B(ORANGE), A. LUTRON NOVA T -STAR SERIES PHASE C(YELLOW), NEUTRAL(WHITE WITH TRACER OR GRAY). GROUNDING SYSTEM(GREEN). B. PRE -APPROVED EQUAL S. PRIOR TO TURNING THE BUILDING OVER TO THE OWNER TURN ON ALL EQUIPMENT IN THE BUILDING G. SOLID STATE TYPE TIME SWITCHES. INCLUDING LIGHTING AND WITH A MULTIMETER, READ THE CURRENT DRAWN ON EACH HOT LEG OF 1. PROVIDE SOLID STATE, PROGRAMMABLE 24 HOUR OR 7 -DAY, ELECTRIC TIME SWITCH WITH FEEDER SUPPLYING EACH DISTRIBUTION PANEL. IF THE CURRENT IN ANY ONE LEG VARIES MORE FOUR (4) SPST CONTACT RATED 20A AT 240 VOLTS. PROVIDE LONG LIFE LITHIUM BATTERY THAN 5% (PLUS OR MINUS) FROM THE ARITHMETIC AVERAGE OF THE CURRENT IN ALL THE HOT BACKUP TO MAINTAIN TIME AND MEMORY SETTING DURING A POWER OUTAGE. LEGS, RECONNECT THE BRANCH CIRCUITS TO OBTAIN A BALANCED LOADING. 2. PROVIDE ASTRONOMICAL CONTROL. T. PROVIDE FIRE BARRIERS AROUND CONDUIT, PIPE, TUBING, BUS DUCTS AND CABLES PASSING 3. ACCEPTABLE MANUFACTURERS: THROUGH SMOKE AND FIRE RATED FLOORS AND WALLS. PROVIDE CP 25, 303 AND PSS7904 A. PARAGON EC7000 SERIES SERIES BY 3M, OR "FLAME -SAFE" SYSTEM BY THOMAS AND BETTS CORP FOR FIRE SEALS. B. TORK MODEL DIOO SERIES U. MAKE CONNECTIONS TO ALL MOTORS AND EQUIPMENT FURNISHED AND SET IN PLACE BY OTHERS. C. H. PRE -APPROVED EQUAL PROVIDE LIGHTING CONTACTORS THAT ADHERE TO THE FOLLOWING SPECIFICATIONS, WHERE PROVIDE STARTERS, MANUAL CONTROLS AND AUXILIARY EQUIPMENT WHERE INDICATED IN LIGHTING CONTROL RELAYS OR CONTACTORS ARE CALLED OUT ON THE DRAWINGS: SCHEDULES AND SPECIFIED HEREIN. PROVIDE ALL DISCONNECT SWITCHES AS INDICATED IN 1. ELECTRICALLY HELD RELAY, 30 AMP BALLAST RATED, 20 AMPS TUNGSTEN RATED ® 277 SCHEDULES, SPECIFIED HEREIN AND REQUIRED BY CODE. VOLTS V. FREE RUN CABLES TO BE SECURED TIGHT AGAINST STRUCTURE. BUNDLE ALL LOW VOLTAGE 2. 2 POLE MINIMUM (REFER TO PLANS FOR REQUIRED POLES) CABLES TOGETHER WHENEVER POSSIBLE. 3. INSTALLED IN NEMA 1 ENCLOSURE INDOORS, NEMA 3R ENCLOSURE OUTDOORS. 16400 - POWER DISTRIBUTION 114. COIL- VOLTAGE: 24VAC. A. PROVIDE FUSES OF THE FOLLOWING TYPES (BUSSMAN USED AS REFERENCE): 5. COORDINATE ACCESSORIES WITH DIVISION 15'S EMS CONTRACTOR. 1. 600 AMPS AND ABOVE: TIME -DELAY TYPE DESIGNED TO HOLD 500% OF RATED CURRENT FOR 6. APPROVED MANUFACTURERS: A MINIMUM OF 4 SECONDS AND CLEAR 20 TIMES CURRENT IN 0.01 SECONDS OR LESS WITH A. SQUARE D CLASS 8903, TYPE 'L' SERIES. INTERRUPTING RATINGS OF 200,000 AMPERES RMS SYMMETRICAL AND PEAK LET -THROUGH B. ASCO 917 SERIES CURRENT AND ENERGY LET -THROUGH VALUES ESTABLISHED BY U.L. STANDARD FOR CLASS L C. SIEMENS TYPE CLM FUSES. PROVIDE KRP-C FUSES. D. PRE -APPROVED EQUAL 2. BELOW 600 AMPS: DUAL -ELEMENT CONSTRUCTION WITH INTERRUPTING RATING OF 200,000 I. PROVIDE PHOTOELECTRIC SWITCH CONTROL WITH A SET OF SPST CONTACTS RATED AT 120 VOLT AMPERES RMS SYMMETRICAL AND PEAK LET-THRU CURRENT ESTABLISHED BY U.L. STANDARD AC, 1800VA IN A NEMA 3R ENCLOSURE. FOR CLASS RK -1 FUSES. PROVIDE LPN-RK/LPS-RK. 1. UL LISTED. 3. MOTOR CIRCUITS: PROTECT ALL INDIVIDUAL MOTOR CIRCUITS WITH FULL LOAD AMPERE 2• APPROVED MANUFACTURERS: RATING (FLA) OF 480 AMPERES OR LESS WITH DUAL -ELEMENT TIME -DELAY FUSES. PROVIDE A. PARAGON CW/210 SERIES LPN-RK/LPS-RK. PROTECT LARGER HORSEPOWER MOTORS WITH TIME -DELAY FUSES. PROVIDE B. F TORK 2101 SERIES I 3. F USED AS A SENSOR INPUT TO THE LIGHTING CONTROL SYSTEM, PROVIDE PHOTOCELL KRP-C FUSES. PROVIDE U.L. CLASS RK1, DUAL -ELEMENT TIME -DELAY FOR ALL OTHER CONTROLLERS FULLY -COMPATIBLE WITH THE LIGHTING CONTROL PANELS USED ON THIS MOTORS,. PROJECT. REFER TO SECTION 16915. 4. MOTOR CONTROLLERS: PROTECT NEMA AND IEC STYLE MOTOR CONTROLLERS WITH J PROVIDE ALL HANGERS, RODS, MOUNTING BRACKETS, SUPPORTS, FRAMES, ETC. FOR PROPER AND DUAL -ELEMENT, TIME -DELAY FUSES TO PROVIDE TYPE 2 COORDINATION FOR THE • SAFE FIXTURE INSTALLATION. INSTALL ALL FIXTURES IN ACCORDANCE WITH MANUFACTURERS' CONTROLLER. PROVIDE LPS-RK FUSES. RECOMMENDATIONS AND INSTRUCTIONS. 5. PROTECT CIRCUIT BREAKER PANELS WITH U.L. CLASS RK1, CLASS L FUSES. PROVIDE LPN -RK, K. PROVIDE FIXTURES COMPLETE WITH ALL AUXILIARIES REQUIRED FOR PROPER, SAFE AND LPS-RK, OR KRP-C FUSES. DISTORTION FREE INSTALLATION IN THE VARIOUS CEILING CONSTRUCTIONS IN WHICH THEY APPEAR. 6. PROVIDE FUSE SIZES AS INDICATED ON THE DRAWINGS. COORDINATE CEILING TYPES WITH THE ARCHITECTURAL DRAWINGS AND PROVIDE COMPATIBLE 7. ACCEPTABLE MANUFACTURERS: BUSSMAN, FERRAZ-SHAWMUT OR LITTELFUSE OR PRE -APPROVED EQUAL. L. FIXTURES. PROVIDE FELT OR FIBERGLASS GASKETS ON ALL INCANDESCENT LIGHTING FIXTURES WHERE B. PROVIDE PANELBOARD ASSEMBLIES ADHERING TO THE FOLLOWING SPECIFICATIONS: NECESSARY TO PREVENT LIGHT LEAKAGE AT THE CEILING LINE. 1. ENCLOSURES CONSTRUCTED OF GALVANIZED SHEET STEEL OF THICKNESS AS REQUIRED BY M. SECURELY SUPPORT ALL LIGHT FIXTURES DIRECTLY FROM BUILDING STRUCTURAL MEMBERS OR CODE, WITH ENAMELED STEEL TRIM, DISTRIBUTED BUSING, HINGED STEEL DOORS LATCHES, LOCKS AND ADJUSTABLE TRIM CLAMPS. PROVIDE NEMA 3R ENCLOSURES FOR EXTERIOR 11/2" OR LARGER STEEL CEILING FRAMING CHANNELS. USE STEEL CHANNEL EQUIVALENT TO LOCATIONS. KINDORF #6029 WHERE IT IS NECESSARY TO SPAN THE BUILDING STRUCTURAL MEMBERS FOR 2. PROVIDE WELDED METAL FRAME WITH TYPED CIRCUIT DIRECTORY FOR EACH PANEL. FIXTURE SUPPORT. WOOD SUPPORTING MEMBERS OR WIRES WILL NOT BE ACCEPTABLE. PROVIDE 3. COMPLIANT TO THE FOLLOWING STANDARDS: UL 50, UL 67, NEMA PB -1, NFPA 70 AND FED. MINIMUM X" DIAMETER LAG SCREWS WHEN ANCHORING INTO WOOD STRUCTURAL MEMBERS. SPEC W -P -115C , UL 489, NEMA AB -1, FED. SPEC. W-C-375B/GEN, IEC 157-1 AND BS PENETRATE WOOD STRUCTURAL MEMBERS A MINIMUM OF 2" WITH ALL SCREWS. PROVIDE STEEL OR 4752. LEAD, EXPANDABLE TYPE, ANCHORS WITH MINIMUM PENETRATION OF 11/2" WHEN ANCHORING TO 4. COMPLIANT TO ARTICLE 408 OF THE NEC: SWITCHBOARDS AND PANELBOARDS. CONCRETE. WHEN INSTALLING LIGHT FIXTURES IN A SEISMIC ZONE, SECURE TO MEET ALL 5. PROVIDE PANELSOARDS WITH SHORT CIRCUIT CURRENT RATINGS AS SHOWN ON THE PLANS. REQUIREMENTS. 6. PROVIDE 240 VOLT AC RATED PANELBOARDS FOR 208/120 AND 240 VOLT AC SYSTEMS. N. DO NOT SUSPEND ANY CONDUIT, LIGHT FIXTURES, OR BALLASTS FROM METAL ROOF DECK OR PROVIDE 480/277 VOLT RATED PANELBOARDS FOR 480/277 VOLT SYSTEMS. FROM THE CEILING SUSPENSION WIRES, SUPPORT ALL LAY -IN FIXTURES INDEPENDENT OF THE 7. PROVIDE TIN-PLATED COPPER BUS BARS OR TIN-PLATED ALUMINUM BUS BARS. CEILING SUPPORT SYSTEM. PROVIDE FASTENING CLIPS ON EACH CORNER OF EACH FIXTURE IN 8. PROVIDE PROPER LUGS (75' C. MINIMUM TEMPERATURE RATING) AND GUTTER SPACE FOR ACCORDANCE WITH THE IBC AND STATE BUILDING CODES. CABLE SIZE INDICATED ON THE PLANS. EQUIP ALL FIXTURES USING CONDUIT STEMS WITH BALL SWIVEL HANGERS. IN FINISHED AREAS, 9. PROVIDE ALL PANELS BY THE SAME MANUFACTURER. PROVIDE CANOPIES FOR THE HANGERS. 10. PROVIDE SCREW MOUNTED, ENGRAVED NAMPLATES FOR EACH PANELBOARD. 0. SUPPORT ALL SURFACE MOUNTED FLUORESCENT FIXTURES WITH A MINIMUM OF ONE HANGER PER 11. PROVIDE MOLDED CASE, NON-ADJUSTABLE, THERMAL -MAGNETIC, QUICK -MAKE, QUICK -BREAK, FIXTURE PLUS ONE PER ROW. SUPPORT INDIVIDUAL FIXTURES WITH A MINIMUM OF TWO HANGERS. BOLT -ON TYPE CIRCUIT BREAKERS. REFER TO THE SCHEDULES ON THE PLANS FOR SIZES ATTACH FIXTURE HANGERS TO THE CEILING GRID PER CODE. AND QUANTITIES. P. SUPPORT ALL SUSPENDED FLUORESCENT FIXTURES WITH A MINIMUM OF TWO FIXTURE HANGERS. 12. PROVIDE MULTI -POLE BREAKERS WHERE INDICATED ON THE SCHEDULES. HANDLE TIES ON ATTACH EACH HANGAR TO A DEDICATED ANCHOR. LOCATE HANGARS DIRECTLY ABOVE THE SINGLE POLE BREAKERS ARE NOT ACCEPTABLE. CORNERS OF THE LIGHT FIXTURES. 13. SERIES RATING OF CIRCUIT BREAKERS IS NOT ALLOWED. Q. WIRE ALL RECESSED LAY -IN FIXTURES WITH 6 FEET OF FLEXIBLE METAL CONDUIT WITH TYPE 14. PROVIDE SECONDARY GROUND BUS IN EACH 208/120V PANEL BOARD. "THHN/THWN" WIRE TO THE OUTLET BOX. PROVIDE GROUNDING TYPE CONNECTORS FOR ALL 15. ACCEPTABLE MANUFACTURERS: CONDUIT AND CABLE. C. 240 VOLT R. PROVIDE OUTLET BOXES ADJACENT TO EACH RECESSED FIXTURE OUTLET IN SUSPENDED CEILINGS "FEED 1. SQUARE D TYPE NQOD OF NF TO PERMIT EACH FIXTURE TO BE ADJUSTED TO FIT CEILING PATTERN AND TO PERMIT 2. SIEMENS TYPE S1 SERIES THROUGH" WIRING. 3. EATON POW -R -UNE 1A SERIES S. AT THE TIME OF SUBSTANTIAL COMPLETION, ALL FIXTURES MUST BE INSTALLED AND LAMPED WITH 4. GENERAL ELECTRIC AQ SERIES NEW LAMPS. INSTALL ALL FIXTURES COMPLETE WITH LENSES, DIFFUSERS, REFLECTORS, LOUVERS 5. PRE -APPROVED EQUAL AND OTHER REQUIRED ACCESSORIES. T. REPLACE ANY DAMAGED REFLECTORS, DIFFUSERS, LOUVERS OR OTHER COMPONENTS AT NO D. 480 VOLT EXPENSE TO THE OWNER. 1, SQUARED D TYPE NF U. CLEAN ALL FIXTURES FREE OF DUST, FINGER PRINTS, PAINT, ETC.. 2. SIEMENS TYPE S2 SERIES V. PERFORM AIMING AND ADJUSTMENT OF ALL LIGHTING FIXTURES IN ACCORDANCE WITH 3. EATON POW -R -UNE 2A SERIES INSTRUCTIONS ISSUED BY THE ENGINEER/TENANT. ADJUST ALL DIRECTIONAL TYPE FIXTURES 4. GENERAL ELECTRIC AE SERIES (INTERIOR AND EXTERIOR) AFTER DARK UNDER THE DIRECTION OF THE ARCHITECT, ENGINEER, 5.PRE-APPROVED EQUAL AND/OR TENANT. E. PROVIDE PANEL IDENTIFICATION LABEL FOR EACH PANEL INCLUDING PANEL NAME, VOLTAGE AND yr, INSTALL DIMMERS WHERE INDICATED ON THE DRAWINGS. FEEDER. FOR EXAMPLE: "HDP -1-1, 480/277 V, 3k, 4 WIRE, 2"C - 4 # 4/0 THWN". 1. WHERE DIMMERS ARE SHOWN GANGED WITH OTHER DIMMERS AND/OR OTHER DEVICES, SIZE F. MOUNT PANELBOARDS AND CABINETS TO BUILDING STRUCTURE OR INTERIOR WALL CONSTRUCTION. OUTLET SUCH THAT DIMMERS WILL NOT BE UNDERATED. MOUNT INDEPENDENT OF CONDUIT AND RACEWAYS ENTERING BOXES. X. INSTALL PHOTOCELL(S) PER MANUFACTURER'S RECOMMENDATIONS. G. MOUNT PANELBOARDS WITH CABINET TOP AT 78" ABOVE FINISHED FLOOR. 1. AIM AWAY FROM ARTIFICIAL LIGHT SOURCES SUCH AS STREET LIGHTS OR SECURITY LIGHTS. H. PROVIDE 3/4 -EMPTY CONDUITS FROM EACH FLUSH MOUNTED PANELBOARD. WHEN THE FLOOR IS 2. SEAL PENETRATIONS THROUGH ROOF OR PENTHOUSE WALL. ON GRADE, PROVIDE THREE (3) CONDUITS INTO THE CEILING CAVITY ABOVE. WHEN THE FLOOR Y. INSTALL TIME SWITCHES ADJACENT TO THE SOURCE LIGHTING PANEL, UNLESS SPECIFICALLY HAS ACCESSIBLE SPACE BELOW, PROVIDE TWO (2) CONDUITS INTO THE CEILING SPACE ABOVE LOCATED ELSEWHERE ON THE PLANS. AND TWO (2) CONDUITS INTO THE ACCESSIBLE SPACE BELOW THE FLOOR. ENDS SHALL BE 1. SET LONGITUDE AND LATITUDE SETTINGS AND THE ASTRONOMICAL TIME. CAPPED AND SHALL BE TAGGED AT BOTH ENDS WITH PERMANENT TAGS. 2. PROVIDE TIME SETTINGS PER THE TENANT'S DIRECTION. 1. PROVIDE A CIRCUIT DIRECTORY COMPLETELY TYPED ON THE INTERIOR OF EACH PANEL DOOR. Z. PROVIDE "NAMEPLATES" A SPECIFIED IN SECTION 16050 FOR ALL CONTACTORS AND 11ME K. EQUIPMENT GROUND - SOLIDLY GROUND ALL CONDUIT SYSTEMS, SWITCH BOXES, CABINETS, MOTOR SWITCHES. LABEL CONTACTORS AND TIME SWITCHES TO INDICATE LOAD SERVED (E.G., CANOPY FRAMES, SWITCHGEAR, TRANSFORMERS, AND ALL OTHER PERMANENTLY INSTALLED EQUIPMENT IN LIGHTS, STORE SIGN, ETC.). ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE TO FORM A CONTINUOUS, PERMANENT AND EFFECTIVE GROUNDING SYSTEM. BOND EXPANSION JOINTS AND 16535 - EMERGENCY LIGHTING METAL RACEWAY SECTIONS. PROVIDE GROUND CONDUCTOR AS INDICATED ON THE DRAWINGS OR A. PROVIDE AUTOMATIC BATTERY POWERED LIGHTING UNITS AS INDICATED ON THE DRAWINGS. SPECIFIED HEREIN. B. PROVIDE EMERGENCY LIGHTING AS SHOWN ON THE PLANS TO ILLUMINATE THE EGRESS CORRIDORS L. T THREE PHASE SYSTEM WHEN CONNECTING SINGLE PHASE CIRCUITS AND EQUIPMENT0 A REE (3) P AREAS. REFER TO THE LIGHT FIXTURE SCHEDULE ON THE DRAWINGS FOR AND OTHER REQUIREDE DISTRIBUTE THE LOADS ON THE PHASES TO ACHIEVE AN APPROXIMATELY BALANCED LOADING OF TYPES. THE THREE-PHASE SYSTEM. C. PROVIDE AN INTENSITY OF NOT LESS THAN 1.0 FOOTCANDLE AT THE FLOOR LEVEL ALONG THE PATH OF EGRESS. 16430 - MOTOR CONTROL D. PROVIDE AN EXIT LIGHT AT EACH EXIT AND ALONG THE EGRESS PATH AS REQUIRED. A. PROVIDE "ON-OFF" TOGGLE TYPE MANUAL STARTER SWITCH WITH THERMAL OVERLOAD PROTECTION E CONNECT EMERGENCY LIGHTS TO THE UNSWITCHED BRANCH CIRCUIT(S) IN THE AREA PROVIDE FOR SINGLE PHASE MOTORS, WHERE MANUAL CONTROL IS INDICATED. PROVIDE EACH SWITCH HANDLE -LOCK DEVICE FOR THAT CIRCUIT. WITH A RED PILOT LIGHT INDICATING WHEN MOTOR IS ON. B. PROVIDE FULL VOLTAGE TYPE STARTERS AND THERMAL OVERLOAD PROTECTION AND EXTERNAL 16741 - VOICE AND DATA RACEWAY MANUAL RESET FOR ALL THREE-PHASE MOTORS, UNLESS INDICATED OTHERWISE. EQUIP EACH A. PROVIDE 4" SQUARE BOXES FOR EACH RECESSED OUTLET BOX. PROVIDE 3%" DEEP MASONRY STARTER WITH 120 VOLT COIL, CONTROL POWER TRANSFORMER, SECONDARY FUSE BLOCK AND TYPE IN RECESSED MASONRY INSTALLATIONS. PROVIDE MUD OR TILE RING AS REQUIRED FOR ALL FUSES, AUXILIARY CONTACTS AS INDICATED, RED "ON" PILOT LIGHT, AND "HAND -OFF -AUTO" BOXES. CONTROL SWITCH. PROVIDE COMBINATION STARTER/DISCONNECT WHEN INDICATED ON THE PLANS. B. PROVIDE THE FOLLOWING IN ACCESSIBLE CEILINGS AS FOLLOWS: PROVIDE AN EMPTY BOX WITH (2) ACCEPTABLE MANUFACTURERS FOR MAGNETIC STARTERS: ALLEN -BRADLEY BULL. 509 & 512, 1-1/2" CONDUITS STUBBED INTO CEILING SPACE FOR EACH TELEPHONE OUTLET INDICATED ON THE SQUARE D CLASS 8536, EATON, GENERAL ELECTRIC, SIEMENS EQUIVALENT OR PRE -APPROVED DRAWINGS; PROVIDE AN EMPTY BOX WITH (2) 1-1/2" CONDUITS STUBBED INTO CEILING SPACE EQUAL. FOR EACH DATA, VOICE/DATA OR FIBER OPTIC OUTLET INDICATED ON THE DRAWINGS; PROVIDE C. PROVIDE MANUAL MOTOR STARTING SWITCH OR TYPE "SS" FUSED DISCONNECT ADJACENT TO EACH AN EMPTY BOX WITH WITH (2)1" CONDUITS STUBBED INTO CEILING SPACE FOR VOICE/DATA 120 VAC SINGLE PHASE MOTOR LOCATED OUT OF SIGHT AND/OR IN EXCESS OF 50'-0" FROM THE OUTLET AT SEASONAL REGISTER LOCATIONS INDICATED ON THE DRAWINGS. CONTROLLER, OR AS INDICATED ON THE DRAWINGS.. C. PROVIDE THE FOLLOWING IN INACCESSIBLE CEILINGS (PLASTER, SPLINE, GYPSUM, SECURITY GRID, D. INTER LOCK ROOFTOP HVAC UNIT FAN STARTER WITH DUCT DETECTOR TO SHUT DOWN FAN UPON PLANK, ETC.) AS FOLLOWS: PROVIDE AN EMPTY BOX WITH (2) 1-1/2" CONDUITS ROUTED TO THE DETECTOR ACTIVATION. NEAREST TELEPHONE BACKBOARD LOCATION FOR EACH TELEPHONE OUTLET, UNLESS NOTED OTHERWISE ON THE PLANS; PROVIDE AN EMPTY BOX WITH (2) 1-1/2" CONDUITS ROUTED TO THE 16460 - TRANSFORMERS A. PROVIDE VENTILATED, INDOOR, DRY -TYPE DISTRIBUTION TRANSFORMER WITH THE CAPACITY AND NEAREST COMMUNICATIONS CLOSET BACKBOARD LOCATION FOR EACH DATA, VOICE/DATA, OR VOLTAGE CHARACTERISTICS INDICATED ON THE DRAWINGS. TRANSFORMERS 15 KVA AND ABOVE FIBER OPTIC OUTLET, UNLESS NOTED OTHERWISE ON THE PLANS; PROVIDE AN EMPTY BOX WITH WILL BE DESIGNED TO OPERATE WITH A 115 DEGREES C. TEMPERATURE RISE ABOVE 40 DEGREES (2) 1" CONDUITS ROUTED TO THE NEAREST COMMUNICATIONS CLOSET BACKBOARD LOCATION FOR C. AMBIENT. PROVIDE ALL INSULATING MATERIALS FOR A 220 DEGREES C. INSULATION SYSTEM. VOICE/DATA OUTLET AT SEASONAL REGISTER LOCATIONS, UNLESS NOTED OTHERWISE ON THE B. PROVIDE TRANSFORMERS MEETING OR EXCEEDING NEMA CLASS 1 EFFICIENCY REQUIREMENTS AS PLANS. REQUIRED IN THE LOCAL ENERGY CODE. C. PROVIDE VOLTAGE TAPS AS INDICATED BELOW., 1. PROVIDE TWO 5% FCBN TAPS FOR ALL SINGLE AND 3 PHASE TRANSFORMERS 9 KVA AND BELOW. 2. PROVIDE TWO 2 1/2% FCBN AND TWO 2 1/2% FCAN TAPS FOR ALL 3 PHASE TRANSFORMERS 15 KVA AND BELOW. 3. PROVIDE FOUR 2 1/2% FCBN AND TWO 2 1/2% FCAN TAPS FOR ALL 3 PHASE TRANSFORMERS ABOVE 15 KVA. D. PROVIDE SOUND RATINGS NOT EXCEEDING THE FOLLOWING LEVELS: 1. 0 TO 15 KVA, 40 DECIBELS. 2. 15 TO 50 KVA, 45 DECIBELS. 3. 50 TO 150 KVA, 50 DECIBELS. 4. 150 KVA OR GREATER, 50 DECIBELS. E. PROVIDE CONTINUOUS COPPER OR ALUMINUM COIL CONDUCTORS WITH BRAZED OR WELDED TERMINATIONS. F. ISOLATE TRANSFORMER CORE AND COIL FROM THE ENCLOSURE USING VIBRATION - ABSORBING MOUNTS. G. PROVIDE TRANSFORMERS 75 KVA OR LESS WITH ENCLOSURES SUITABLE FOR WALL, FLOOR OR TRAPEZE MOUNTING. PROVIDE TRANSFORMER LARGER THAN 75 KVA WITH ENCLOSURES SUITABLE FOR FLOOR OR TRAPEZE MOUNTING. H. PROVIDE MAXIMUM CASE TEMPERATURES NOT EXCEEDING A 35C TEMPERATURE RISE ABOVE A 40 DEGREE C AMBIENT. I. ACCEPTABLE MANUFACTURERS: EATON, GENERAL ELECTRIC, SIEMENS, SORGEL, HEVI-DUTY JEFFERSON ELECTRIC OR PRE -APPROVED EQUAL. I, Ryan J. Lindahl certify that this plan Specification, or report was prepared by me or Under my direct supervision, and that I am a duly Licensed Engineer under the laws of the State of Massachusetts. 00-0 W z 0 W U L.L.. UW) W CW G 0 �r� W Z) U ITj LoJ L U N N C) G LL. F_ �Wr� O c vJ 0 Z) G 0T� .L. z >- 0 I- 1- D 00 r U) Preliminary Issue: 09/06/2019 Bid Issue: 09/10/2019 Landlord Issue: 09/10/2019 Permit Issue: 09/10/2019 Construction Issue 09/10/2019 ELECTRICAL SPECIFICATIONS Comm. Number R19-3627.012 Date 09/10/2019 Drawn By CTC Checked By DJQIPJF E2.0