Loading...
HomeMy WebLinkAboutEngineered Plans - Rev. 2019SOIL LOG DATE: OCTOBER 9, 2019 SOIL EVALUATOR: DARREN M. MEYER, R.S., WITNESS: PHIL RENAUD, YARMOUTH HEALTH Bois TP -1 Depth 13.90 0" FlLL 12.72 14" A LOAMY SAD 11.90 24' B D 1l 0YR 5/6 10.32 43" C PERC TEST MEDIUM SAND V— 8.48 2.5Y 7/4 5.90' 1 96" PERC RATE <2 MINAN. (-Cl- HORIZON) GROUNDWATER OBSERVED AT 72' EL 7.90 WELL: M¢W-29 ZONE A. LEVEL 7.8, AW 1.4' ADJUSTED GROUNDWATER a". 9.30 TBM = EL. 13.5 BULKHEAD FOUNDATION 13.1 3.2 Permit valid for REPAIR OF SEP' €1C SYST'm EiBNLI, due to State anti Local seldic variances. [Board of llea¢th rc sieve and apt royal is required for any future ackdi¢ions/renovat4onsta iterations to sewage facilities andior struetnresld wetking. Yarmouth Flealth [Depattntent APPROVED L4 41 Date 10 LOT 9 10,262 s.f. VA rt1 F .e_ LEGEND WEST YARMOUTH PROPOSED CONTOUR c ® PROPOSED SPOT GRADE �2 -- gg -- EXISTING CONTOUR e + 96.52 EXISTING SPOT GRADE �RCfgF yIr —W— EXISTING WATER SERVICE W y TEST PIT �O/, SCALE 1"=20' {yq4/S 0 14 40 ml POLY LINER (note 17) SE l ?�00• �a 14.21 LOCUS MAP • LOCUS INFORMATION PROP. 5FT PLAN REF: 182/139 \ SOIL REMOVAL TITLE REF: 3127/249 1 PARCEL ID: MAP 17 PAR. 178 ky-WtS W0 I PROP. GEOGRIDI ��������� SEPTIC SYSTEM 13.9 REPAIR PLAN LOCATED AT: 12 SANDPIPER LANE WEST YARMOUTH, MA PREPARED FOR JOHN SERGI/ CLIFFORD EXCAV. OCTOBER 21, 2019 REV: NOVEMBER 12, 2019 ti of A4.1 `N OF I(' Fb 002 STEVE W. cym SPD RREN M. ti/ B'9�, o NO. 35 91 ti �•_/ w No. 1140 8F0 QVC 4�7 FLOORPLAN MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 SURVEY BY: meyerandsonstitle5@gmail.com WELLER & ASSOC. SHEET 1 OF 2 J#2120 T.O.F. EL=15.0 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS PROPOSED TANK PUMP CHAMBER O INSTALL RISERS TO FINISH GRADE W/ INSTALL RISERS to FINISH GRADE W/ INSTAL RISERS W/IN 6" OF FINISH GRADE LOCI(ING COVERS LOCKING COVERS -EL14.Ot EL. 14.Ot I EL.14.0t F.G. EU 16.0t -1 . 1 ARE TO BE H 40 PVC u y OMP PUMP CHAIN. (SEE DETAIL PROPOSED 1,500/500 GALLON 2 -COMPARTMENT SEPTIC TANK NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION. 2) SEPT TANK/PUMP CHAMBER AND D -BOX SHALL BE SET TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL PVC INLET/OUTLET TEES IN SEPTIC TANK AS REQUIRED. 4) GAS BAFFLE W/ FILTER TO BE INSTALLED ON OUTLET TEE INSTALL 1' PVC CONDUIT TO HOUSE FOR WIRING WITH WATERTIGHT JOINTS. WIRE HIGH WATER ALARM FLOAT TO GP 2000 HIGH WATER ALARM PANAL ON CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP. HOISTING CABLE 7x19 STAINLESS STEEL 1/8" DIAMETER. / 1,760 LB. STRENGTH.- PC TRENGTH:PC (OU7)=11.70 T ALARM ON EU 9.03 PUMP ON EU 8.70 PUMP OFF EL: 8.37 le' L 6 BOTTOM OF INT. P.C. EL 7.70 1 as. 1% INV.= 11.70 IWALL SMfMRY INV.- 14.92J D -SO ` TEE SHALL NOT EXTEND RFLOW FLOW UNE DB -5 W/BAFFLE) 75 SEPTIC SYSTEM PROFILE . PROVIDE WATERTIGHT CONCRETE RISER NTH SECURED COVER TO GRADE NEMA 4 JUNCTION BOX CORROSION RESISTANT & LIQUID -TIGHT CABLE CONNECTORS SUPPORTED BY 1-1/4' PVC CONDUIT. JOINTS TO BE MADE WATERTIGHT .2"BALL VALVE W/ UNIONS SCH. 80 PVC GEORGE FISHER CO. MODEL NO. 560 INH EQUAL 2"SCH. 40 DISCHARGE TO D-BOX -2"SCH. 40 TEE W/ CLEAN-OUT CAP PROVIDE 1/4' WEEP HOLE IN DISCHARGE PIPE FOR SELF -DRAINING FORCE MAIN -2' BALL CHECK VALVE SCH. 80 PVC 100 P.S.I. FLOWMATIC MODEL No. 2085 PROVIDE - WIDE N cOATS: '-2* SCH. 40 PVC DISCHARGE PIPE FLOAT NO.l: PUMP FLOAT NO.2: ALARM AACTIIVATSON (BARNESOBARNES618 073612EOR EQUAL) BARNES SEV412 PUMP .5 H.P. 115 V 2' DISCHARGE PASSING Y SOLIDS OR EQUAL NOTE: SEPTIC TANK AND PUMP CHAMBER TO BE FACTORY WATERPROOFED AND SEALED WITH THOROSEAL OR EQUAL PUMP & ACCESSORIES AVAILABLE AS A UNIT THROUGH WIGGEN PRECAST CORP., BOURNE MA. (800) 564-6774 PUMP & ACCESSORIES AVAILABLE THROUGH WIWAMSON ELECTRIC (781) 444-6800 PUMP DETAIL BUOYANCY CALCULATIONS PROP. 2.000 GALLON PUMP CHAMBER: AIR= 12' x 7' x 4 x 62.4 - 20,996 IW 9M'ad TWX x 7' x 0.75 x 120 - 7,560 lbs emab tank . 16.6011 lbe arotuwl er + m btv tank > upM, 7,580 + 16,000 a 23,560 The > 20,996 lbs PUMP CHAMBER BUOYANCY CHECK 0.16 DOSING & STORAGE REQUIREMENTS DAILY FLOW: 330 GPD DOSING REQUIRED: 8 CYCLES/DAY (SAND) 330 = 8 = 41 GALLONS/CYCLE DISTANCE REQUIRED BETWEEN PUMP ON AND PUMP OFF FLOATS: 41 GAL/CYCLE = 125 GAL/FT = 0.33 FT/CYCLE (4') STORAGE REQUIRED ABOVE WORKING LEVEL;- 330 GALLONS STORAGE PROVIDED: INV. EL:* 7.33 - ALARM ON EL' 4.66 -2.67' STORAGE PROVIDED = 2.67' X 125 GAL/FT = 333 GALLONS N.T.S. FINISH GRADE -15.77 MAINTAIN 2% MIN SLOPE OVER LEACHING AREA L-10'(MAX) 0 S= 1% (MIN.) MIN. COVER OVER S.A.S. - 9" TWO INSPECTION 4 ROWS OF 6 UNITS AT 4.0'/UNIT - 24.0'/ROW INv.ELEv.=14'63 SOIL ABSORPTION SYSTEM ROFILEI RESTORE VEGETATIVE COVER POLY LINER (note 17) PERC SAND BREAKOUT=TOP ELEV.=15.02 COVER UNITS WITH ''>, FILTER FABRIC INV. ELEV.= 14.63 BOTTOM ELEV.= 14.35 EXISTING SUITABLE 2.83 MATERIAL 5' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 4 x 2.83' - 11.32' (5.05' PROVIDED) USE 4 ROWS OF 6 INFILTRATOR QUICK 4 PLUS ADJ. GROUNDWATER EL.=9.30 _ STD LP 133" INVERT) UNITS -NO STONE GENERAL NOTES: I. ALL CHANGES 70 THIS PUN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERINS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOGO. RULES AND REWUTKINS. 3. THE SEWAGE DISPOSAL SYSTEM SHAD. NOT BE BACIFUUED PRIM TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED WRING CONSTRUCTION DIFFERING SHOWN H REPORTED TO THE SIGN ENGINEER PES 5. ALL ELEVAT06 BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF CONTRACTOR OR IDRE�� OF HEALTH FOR PROPERINSPECTIONS UINGCON5TRUCTION. 7. WATER SUPPLY PROVIDED BY MUNICIPAL WATER. 8. ALL AREAS DISTURBED WRING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES. PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACHING (IN REAR) TO BE CRUSHED, PUMPED AND REMOVED. REPLACE WITH CLEAN MEDIUM SAND PER TITLE S. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS MAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPE TO BE 4" SCH 40 O 1/8'/FT (UNLESS SPEC. OTHERIWSE) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 17. MACE 40m] POLY LINER FROM EL 15.02-11.02 AROUND ENTIRE EDGE EDGE OF SOIL REMOVAL TO PREVENT BREAKOUT. PLACE GEOGRID UNDER LEACHING, EXTENDING 1 FOOT PAST PERIMETER TYPICAL SECTION KTA DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BR DESIGN ***NOT IN ZONE II*** SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 G.P.D. DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER) SEPTIC TANK/PUMP CHAMBER: 330 gpd x 450% = 1,485 gpd USE 2 -COMP 2,000G TANK (1,50OG/500G) LEACHING AREA REQUIRED: (330)/0.74 = 445.94 S.F. DISTRIBUTION BOX: (3 OUTLETS (MINIMUM)) PRIMARY S.A.S. USE 4 ROWS OF 6 - INFILTRATOR QUICK 4 STD LP (3.3- INVERT) UNITS WITH NO STONE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) (CHAMBER UNITS) 24 UNITS x 4.00 LF x 4.73 SF/LF = 454.08 SF TOTAL AREA = 454.08 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(454.08SF) = 336 GPD > 330 GPD PROPOSED SEPTIC SYSTEM UPGRADE PLAN 12 SANDPIPER LANE, WEST YARMOUTH, MA Design and Site Plan by: SCALE DRAWN DATE MEYER 8 SONS, INC. N.T.S. DMM 10/21/19 PO Box 61 E4STSANOWICN, MA02537 REV. DATE SHEET NO. ASTSA 505-362.2922 11/12/19 2 of 2