HomeMy WebLinkAboutEngineered Plans - Rev. 2019GENERAL NOTES: 1. PROPERTY LINE DATA FROM "PLAN OF LAND IN YARMOUTH. MADE FOR THE MULVANEY FAMILY REVOCABLE TRUST, DIANNE MULVANEY, TRUSTEE." BY SLADE ASSOCIATES, INC., DATED NOVEMBER 5, 2014, RECORDED AT BARNSTABLE COUNTY REGISTRY OF DEEDS PLAN BOOK 658 PAGE 11. 2. TOPOGRAPHIC SURVEY BY GRADY CONSULTING, LLC, JUNE 2019. ELEVATIONS ARE RELATIVE TO NAVD 88 DATUM. 3. BY GRAPHIC PLOTTING ONLY, THIS PROPERTY IS PARTIALLY LOCATED IN ZONE "X" OF THE FLOOD INSURANCE RATE MAP, AS DEPICTED ON COMMUNITY PANEL No. 25001C 0569J, _ EFFECTIVE DATE JULY -16, 2014. 4. WATER SERVICE AND HEDGE ROW 1.5" MAIN LOCATION BASED ON SERVICE CARD FOR 47 BROADWAY, PROVIDED BY THE TOWN OF YARMOUTH WATER DEPARTMENT. 5. UNLESS OTHERWISE INDICATED, THERE ARE NONE OF THE FOLLOWING PROXIMATE TO THE PROPOSED SOIL ABSORPTION SYSTEM: • SLAB FOUNDATIONS WITHIN 10 FEET • WATER SUPPLY LINES (PRESSURIZED) WITHIN 10 FEET • SURFACE WATERS, BORDERING VEGETATED WETLANDS, SALT MARSHES, INLAND OR COASTAL BANKS WITHIN 50 FEET • SURFACE WATER SUPPLIES (RESERVOIRS & IMPOUNDMENTS) WITHIN 100 FEET, OR TRIBUTARIES THERETO WITHIN 100 FEET • WETLANDS BORDERING SURFACE WATER SUPPLIES OR THEIR TRIBUTARIES WITHIN 100 FEET • CERTIFIED VERNAL POOLS WITHIN 100 FEET • PRIVATE WATER SUPPLY WELLS OR SUCTION LINES WITHIN 150 FEET • THE ZONE 1 AREA OF A PUBLIC WATER SUPPLY WELL • IRRIGATION WELLS WITHIN 25 FEET • OPEN, SURFACE OR SUBSURFACE DRAINS THAT DISCHARGE TO SURFACE WATER SUPPLIES OR THEIR TRIBUTARIES WITHIN 100 FEET • OPEN, SURFACE OR SUBSURFACE DRAINS THAT INTERCEPT SEASONAL HIGH GROUNDWATER TABLE WITHIN 50 FEET • LEACHING CATCH BASINS AND/OR DRY WELLS WITHIN 25 FEET • DOWNHILL SLOPES WITHIN 15 FEET 4. THE PROPOSED SYSTEM LOCATION IS NOT LOCATED WITHIN OR LESS THAN 100 FEET FROM ANY NITROGEN SENSITIVE (ZONE I OR ZONE II) AREA. 5. THERE ARE VARIANCES TO THE PROVISIONS OF 310 CMR 15.000 SOUGHT IN CONJUNCTION WITH THIS PLAN; REFER TO THE APPLICABLE NOTES ON THIS SHEET. TEST HOLE DATA EX GRADE ELEV 14.3 TEST HOLE #TH1 0"A14" DATE EXCAVATED: 6/20/19 LOAMY SAND EX. GROUND ELEVATION: 14.3 TOTAL DEPTH: 114"/ELEV 4.8 GWT DEPTH: 114"/4.8 13.1 14"-36" B SAND 11.3 SOIL EVALUATION & PERC PERCOLATION TEST NOTE: 44"-52" SOIL & PERCOLATION TESTING BY BRENDAN 36"-114" P.R.<2 KLING, GRADY CONSULTING, L.L.C. JUNE 20, C MIN/IN 2019 WITNESSED BY AMY VonHONE. SAND SOIL ABSORPTION •4.8 SYSTEM DESIGN: D=9'-6" EXISTING SOIL DATA:NWATER CLASS I SOILS (SANDS): <2 MPI PERCOLATION RATE LOADING RATE: 0.74 GPD/SF (<5 MPI PERC RATE) TOTAL DAILY FLOW: 5 -BEDROOM RESIDENTIAL DESIGN FLOW: 110 GPD/BEDROOM x 5 BEDROOMS = 550 GPD SOIL ABSORPTION SYSTEM AREA: CONVENTIONAL FIELD: 550 GPD/0.74 GPD/SF = 744 SF INFILTRATOR 3050 UNITS: 15 UNITS x 7.12 LF/UNIT (INSTALLED) = 106.8 LF EFFECTIVE LEACHING BED AREA = 106.8 LF x 7.1 SF/LF UNIT = 758 SF REFERENCE: MADEP INFILTRATOR APPROVAL FOR GENERAL USE, JUNE 12, 2015 TABLE 3: EFFECTIVE LEACHING AREA FOR BED OR FIELD CONFIGURATION NEW CONSTRUCTION AND REMEDIAL SITES SEPTIC TANK: FOR SINGLE-FAMILY DWELLING W/DESIGN FLOW < 1,000 GAL/DAY: SINGLE COMPARTMENT = 200% DESIGN FLOW (48 HRS) = 2 X 550 = 1,100 GALLONS (REQUIRED) TOTAL 1,100 GALLONS REQUIRED; 1,500 -GALLON TANK PROVIDED NOTE: GARBAGE DISPOSALS SHALL NOT BE ALLOWED TO BE CONNECTED TO THE OSSD TOP OF FOUNDATION ELEV=16.14 •` INTERIOR OF EX i DWELLING I CRAWLSPACE GROUND ELEV=14.0± i I INV FOUNDATION ELEV=13.6± BASEMENT I CUT & CONNECT TO SLAB EX 4" CI PIPE ±4' ELEV=9.8± _ FROM FOUNDATION; _ [ USE WATERTIGHT _........,... r!, FOUR (4) STRAP I COUPLING i I E1= WAY I, BRAD 4" SCH 40 PVC FROM 8 -HOLE DISTRIBUTION BOX D -BOX TO CHAMBERS INV IN=11.21 (TYP OF 3) INV OUT= 11.00. . _..... ...... .........__ ...._......__.........___. S=1.0� __... r':6..ie�.'._ ` =`DIY �,' v EDGE CONCRETE �31L%Yrv:r _ a e_ o _ S ......._._._. _ aPn�� . m .'.`\... 9T1,9 l CLEANOUT LOT ------5- ��EO 'wa AREA: IGP J ATOR 3050 CHAMBER S 9 OOOt SF LEACHING BED: S � MIN=15.1 I ROWS ® 5 UNITS 4CH 10' PROPERTY S;.}I 99 LF 4" SCH 40 PVC P OF CHAMBER ELEV=11.54 TO3 LINE SETBACK :� PIPE 1. BOTTOM OF CHAMBER ELEV=9lt04 % I �gr5v I I SEPTI =1.1� INV. IN710 95 TOP ELEV=11.95 f i ✓: RkfFr F SOLID 4S 3 ROWS OF 5 UNITS CLEANOUT PROPERTY LINE 10'-'2"-"� ... j+ f -;oulK % SETBACK r r ;' u 1 / I h}• tt w { S= r 11l! i1 I= 1 N i r r`� / n VARIANCE AREA '_ ? PUr ,ri='`S / "AlJl ry �; ±160 SF 5'-6" I / - 20, s ••BASEMENT<' INSPECTION ti! '40 -MIL SETBACK t IMPERMEABLE PORT �5 LINER x'47pml V ON Ij_ Tt`rl3 _: SETBACK -' I BASEMENT _a. `tY--� \ VARIANCE AREA ' ` > _ ±38 SF ! = 15 /, .,.:�' ref.. ' _ I to tA ; ' �� � � £ �r`�•. kaY � � 1 , 5 1 P LaASL.:,+ - r ;:. , :l µ_.... vv sist M 1 L _ i :..r W i -------LOCATE, CUT & CONN_f+ _ r ,t f,< Co irA'ETL PATil TO_-EX--4---Ct_-PP I PE, USE ...., F, 1 _..,.it WATERTIGHT FOUR (4). �f TRAP COUPLING :,..... ter., .. r'CS LF 4 �. �._._.._._....�,.._._..._..._..._._.,_L. _ _ jSCH 40 PVC . - -- 06F OF P10dAi � SEPTIC PIPE I %f i BENCHMARK S=1.0% t MAG NAIL _ Ari v/11TI r IN PAVEMENT I i t r R&D EX 4" CI ELEV=13.32 • •lam � TO i (NAVD 88) EPSL� l= P>r1I/EIVE T --- EX LEACH PIT - - • ........_............G.. _. 10 LUX _.: __...__ t 0; l ! i SUGGESTED INSTALLATION SEQUENCE: 1. EXCAVATE TEST PIT TO DETERMINE ELEVATION OF EXISTING 4" CI PIPE FROM HOUSE TO LEACH PIT AT PROPOSED CONNECTION POINT TO NEW 4" PIPE 2. INSTALL SAS, D -BOX, PIPING AND SEPTIC TANK 3. CUT & CONNECT EXISTING 4" CI TO NEW 4" PVC TO SEPTIC TANK 4. R&D REMAINING EXISTING 4" CI PIPE TO LEACH PIT AND DEMOLISH EXISTING LEACH PITS INSTALL MAGNETIC WARNING TAPE FINISH GRADE ABOVE TANK (OR COMPARABLE PRODUCT) FINISH GRADE ABOVE MAX=14.4 OVER ALL SYSTEM COMPONENTS (TYP) BED (EXCLUDING 4" TOPSOIL) VENT MIN=14.3 ' FINISH GRADE MIN=14.30 MAX=14.80 SET RISERS/COVERS ABOVE D -BOX -TO FINISH GRADE MAX=15.3 INSPECTION PORT 10 i1` (••tit `••` �................�......�....,,... ..,,rte. 1.500 -GAL ONE -COMPARTMENT y SEPTIC TANK INV IN=12.55 `1_ I INV OUT= 12.30 tn f /V: \, t"', r. .�"�� to �,,, i �,....� •\,_.. \_i �y ' t _... �. t\y g ~ ~ L . L..;''?Itv 1, s%V✓lf Ar`,•tom i" iW'.' h � CIV AS .....��Ul{ .r �;1''LAf';'f j'r11r R/ COV' AT DEMOLISH EX LEACHING PITS 1 f IN ACCORDANCE WITH DEP 618 STANDARDS PROCEDURES ASS'L.L,SOk P.�,RCE-L 22-- ,#, 6 f7'LDG� ` /'01/;/ I tV/P 1:..LL.NX, 1, FF1JRS ?.FFV L500A' 29049 F,1116Z' 119 GRAPHIC SCALE s 10 20 1 40 ( IN FEET ) 1 inch = 10 ft. NOTE DEPICTED ATE 'zlk'z WOULDTHE REQUIRE APPRECIABLY Iag �AO�AAQCOrA Y RELIEF FROM APPLICABLE SETBACKS THAN THE PROPOSED SAS LOCATION ;:: _..__.._.....\__............._..._._._..._.__... .�... _ '10' PROPERTY--�� � MIN=15.1 (SET 3" BELOW F.G.) 10' f � S HOUSE (iAB 9- (AW TO FOUNDATION) `k 4"0 SOLID �gr5v 9"MIN/36- MAX � SFR= L INFILTRATOR 3050 CHAMBERS, TOP ELEV=11.95 SCH40 GASKETED i ✓: RkfFr F SOLID 4S 3 ROWS OF 5 UNITS (FOLD EXCESS - - PVC PIPE 4"0 SOLID SCH40 S DR 35 '- - - - - - - - - - - - - - - - - - PORTION OF GASKETED PVC PIPE I - - - - - - - - - PVC PIPE TOP OF CHAMBER ELEV=11.45 LINER ROLL L=8' ucaul� LEVEL - - - __ - - _ TOWARD S -AS REQD - 10 (�u�N) L=99' S=0.011 L=7' INV IN ELEV=10.95 CHAMBERS MATCH T. , �;:�,.,� S=0.01'/'; 40 -MIL INV ® TANK SET LEVEL FOR BOTTOM OF CHAMBER ELEV=8.95 IMPERMEABLE (MIN.0.01'/') FIRST 2'5, AIN LINER ZABEL EFFLUENT CLEARANCE BOTTOM 1,500 GAL ONE -COMPARTMENT TEE FILTER DISTRIBUTION BOX W/RISER TO 6WI (4.15' PROWDEO) ELEV=8.95 SEPTIC TANK SEE DETAIL SHEET) MAX GROUNDWATER ELEV=4.8 _ L (SEE DETAIL SHEET) LEVELED & COMPACTED INLET INV ELEV=11.21 INLET INV=12.55 » BELOW 6 D OUTLET INV ELEV=11.00 SOIL ABSORPTION SYSTEM LEACHING BED OUnET [W.=12.30SUBBASE CRUSHED STONE SYSTEM PROFILE NOT TO SCALE 10 i1` (••tit `••` �................�......�....,,... ..,,rte. 1.500 -GAL ONE -COMPARTMENT y SEPTIC TANK INV IN=12.55 `1_ I INV OUT= 12.30 tn f /V: \, t"', r. .�"�� to �,,, i �,....� •\,_.. \_i �y ' t _... �. t\y g ~ ~ L . L..;''?Itv 1, s%V✓lf Ar`,•tom i" iW'.' h � CIV AS .....��Ul{ .r �;1''LAf';'f j'r11r R/ COV' AT DEMOLISH EX LEACHING PITS 1 f IN ACCORDANCE WITH DEP 618 STANDARDS PROCEDURES ASS'L.L,SOk P.�,RCE-L 22-- ,#, 6 f7'LDG� ` /'01/;/ I tV/P 1:..LL.NX, 1, FF1JRS ?.FFV L500A' 29049 F,1116Z' 119 GRAPHIC SCALE s 10 20 1 40 ( IN FEET ) 1 inch = 10 ft. NOTE DEPICTED ATE 'zlk'z WOULDTHE REQUIRE APPRECIABLY Iag �AO�AAQCOrA Y RELIEF FROM APPLICABLE SETBACKS THAN THE PROPOSED SAS LOCATION ;:: _..__.._.....\__............._..._._._..._.__... .�... _ '10' PROPERTY--�� LINE SETBAq-K f, 10' f � S HOUSE (iAB FOUNDATION) `k SET CK i �gr5v i AS�. i ✓: RkfFr F <TO, f :� r�11. ?t i\ i tt \ L i 20' BASEMENT SETBACK (HOUSE #53) rfS PA _x:. V-4 r �G ADW ALTERNATE SAS LOCATION DETAIL SCALE: 1 " = 20' SCALE: NOT TO SCALE LEGEND EXISTING PROPOSED 'PROPERTY LINE - - ABUTTER LINE ------ - --- REBAR MONUMENT SOIL EVALUATION TIH EDGE OF PAVEMENT - - - Permit valid for REPAIR OF SEPTIC SVSTE09 ,'FENCELINE ONLY, due to State and Local septic variances. Board of Health review and approval is required for TREELINE any future addilions/renovations/alterations to sewage facilities and/or structures/dwelling. (CONTOUR LINE ��'f. SPOT GRADEYarmouth Hcalth Department ;UTILITY POLE z APPROVED OVERHEAD WIRE;.:,.y........_.....__............... ;WATER LINE szt .. WATER GATE VALVE lotasaae 77 Date WATER CURB STOP HYDRANT ,GAS LINE .................................. ...._........................ __ ,SEPTIC PIPE t:; .............................................. S .................... _ _ _ ............... SEPTIC TANK ...................i VARIANCES REQUESTED: THE FOLLOWING VARIANCES WILL BE NECESSARY TO ACCOMMODATE THE PROPOSED SYSTEM, AND ARE HEREBY REQUESTED: CMR 15.211 - MINIMUM SETBACK DISTANCES PROPERTY LINE (HEDGE ROW): REQUIRED: 10 FEET \r PROPOSED: 5.5 FEET VARIANCE: 4.5 FEET CELLAR (BASEMENT) WALL: REQUIRED: 20 FEET PROPOSED: 15 FEET VARIANCE: 5 FEET �I NOTES: 1. AN IMPERVIOUS BARRIER (40 -MIL LINER) SHALL BE PROVIDED WITHIN THE CELLAR SETBACK AREA, FIVE (5) FEET OFF THE EDGE OF THE SAS. 2. THERE ARE NO ABUTTING FOUNDATIONS/CELLARS WITHIN TWENTY (20) FEET OF THE PROPOSED LEACHING FACILITY. CMR 15.212 - DEPTH TO GROUNDWATER REQUIRED: 5 FEET IN SOILS WITH RECORDED PERC RATE < 2MP1 PROPOSED: 4.15 FEET (BOTTOM OF SAS ELEV=8.95, GWT ELEV=8.80) VARIANCE: 0.85 FEET CONDITIONS REQUIRED FOR GROUNDWATER SEPARATION REDUCTION (MA CMR 15.405(3)(h): 1. DETERMINATION OF HIGH GWT ELEVATION BY LOCAL APPROVING AUTHORITY SOIL EVALUATOR - MET 2. MINIMUM 4 FOOT SEPARATION IN SOILS WITH PERC RATE < 2MP1 - MET 3. NON -CONFORMING SYSTEM SERVING EXISTING BUILDING WITH < 2,000 GPD DESIGN FLOW - MET 4. NO INCREASE IN DESIGN FLOW - MET 5. NO REDUCTION IN SAS SETBACKS FROM PUNLIC/PRIVATE WELLS, BORDERING VEGETATED WETLANDS, SURFACE WATERS, SALT MARSHES, COASTAL BANKS, CERTIFIED VERNAL POOLS, WATER SUPPLY LINES, SURFACE WATER SUPPLIES OR TRIBUTARIES THERETO, OR DRAINS THAT DISCHARGE TO SURFACE WATER SUPPLIES OR THEIR TRIBUTARIES - MET r' n AA 1%./1 e-% N_ I AL A / C 1 -1- LA �gr5v AS�. i ✓: RkfFr F <TO, :� r�11. rfS PA _x:. V-4 r �G ADW ALTERNATE SAS LOCATION DETAIL SCALE: 1 " = 20' SCALE: NOT TO SCALE LEGEND EXISTING PROPOSED 'PROPERTY LINE - - ABUTTER LINE ------ - --- REBAR MONUMENT SOIL EVALUATION TIH EDGE OF PAVEMENT - - - Permit valid for REPAIR OF SEPTIC SVSTE09 ,'FENCELINE ONLY, due to State and Local septic variances. Board of Health review and approval is required for TREELINE any future addilions/renovations/alterations to sewage facilities and/or structures/dwelling. (CONTOUR LINE ��'f. SPOT GRADEYarmouth Hcalth Department ;UTILITY POLE z APPROVED OVERHEAD WIRE;.:,.y........_.....__............... ;WATER LINE szt .. WATER GATE VALVE lotasaae 77 Date WATER CURB STOP HYDRANT ,GAS LINE .................................. ...._........................ __ ,SEPTIC PIPE t:; .............................................. S .................... _ _ _ ............... SEPTIC TANK ...................i VARIANCES REQUESTED: THE FOLLOWING VARIANCES WILL BE NECESSARY TO ACCOMMODATE THE PROPOSED SYSTEM, AND ARE HEREBY REQUESTED: CMR 15.211 - MINIMUM SETBACK DISTANCES PROPERTY LINE (HEDGE ROW): REQUIRED: 10 FEET \r PROPOSED: 5.5 FEET VARIANCE: 4.5 FEET CELLAR (BASEMENT) WALL: REQUIRED: 20 FEET PROPOSED: 15 FEET VARIANCE: 5 FEET �I NOTES: 1. AN IMPERVIOUS BARRIER (40 -MIL LINER) SHALL BE PROVIDED WITHIN THE CELLAR SETBACK AREA, FIVE (5) FEET OFF THE EDGE OF THE SAS. 2. THERE ARE NO ABUTTING FOUNDATIONS/CELLARS WITHIN TWENTY (20) FEET OF THE PROPOSED LEACHING FACILITY. CMR 15.212 - DEPTH TO GROUNDWATER REQUIRED: 5 FEET IN SOILS WITH RECORDED PERC RATE < 2MP1 PROPOSED: 4.15 FEET (BOTTOM OF SAS ELEV=8.95, GWT ELEV=8.80) VARIANCE: 0.85 FEET CONDITIONS REQUIRED FOR GROUNDWATER SEPARATION REDUCTION (MA CMR 15.405(3)(h): 1. DETERMINATION OF HIGH GWT ELEVATION BY LOCAL APPROVING AUTHORITY SOIL EVALUATOR - MET 2. MINIMUM 4 FOOT SEPARATION IN SOILS WITH PERC RATE < 2MP1 - MET 3. NON -CONFORMING SYSTEM SERVING EXISTING BUILDING WITH < 2,000 GPD DESIGN FLOW - MET 4. NO INCREASE IN DESIGN FLOW - MET 5. NO REDUCTION IN SAS SETBACKS FROM PUNLIC/PRIVATE WELLS, BORDERING VEGETATED WETLANDS, SURFACE WATERS, SALT MARSHES, COASTAL BANKS, CERTIFIED VERNAL POOLS, WATER SUPPLY LINES, SURFACE WATER SUPPLIES OR TRIBUTARIES THERETO, OR DRAINS THAT DISCHARGE TO SURFACE WATER SUPPLIES OR THEIR TRIBUTARIES - MET r' n AA 1%./1 e-% N_ I AL A / C 1 -1- LA SPECIFICATIONS & DESIGN NOTES: 1. THE PROPOSED SANITARY SEWAGE DISPOSAL SYSTEM SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE LATEST REQUIRMENTS OF 310 CMR 15.000: THE STATE ENVIRONMENTAL CODE, TITLE 5: STANDARD REQUIREMENTS FOR THE SITING, CONSTRUCTION, INSPECTION, UPGRADE AND EXPANSION OF ON-SITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS AND FOR THE TRANSPORT AND DISPOSAL OF SEPTAGE. IN ADDITION, ALL CURRENT LOCAL AND MUNICIPAL REQUIREMENTS SHALL BE STRICTLY ADHERED TO. 2. ALL SEPTIC TANKS, TIGHT TANKS, PUMP CHAMBERS, DOSING CHAMBERS AND GREASE TRAPS, INCLUDING THE REQUIRED ACCESS MANHOLE(S), SHALL BE WATERTIGHT. ALL STRUCTURES SHALL BE CONSTRUCTED OR SET LEVEL AND TRUE TO GRADE ON A LEVEL STABLE BASE WHICH HAS BEEN MECHANICALLY COMPACTED. IF PLACED IN FILL, PROPER COMPACTION IS REQUIRED TO ENSURE STABILITY AND TO PREVENT SETTLING; NATIVE GROUND WITH A SIX-INCH AGGREGATE BASE IS OTHERWISE ADEQUATE. 3. THE TOP OF ALL SYSTEM COMPONENTS, INCLUDING THE SEPTIC TANK, DISTRIBUTION BOX, PUMP CHAMBER, DOSING CHAMBERS AND SOIL ABSORPTION SYSTEM, SHALL BE INSTALLED NO MORE THAN 36" BELOW FINISH GRADE. 4. THE BUILDING SEWER SHALL BE CONSTRUCTED OF CORROSION RESISTANT MATERIAL (CAST-IRON, SCHEDULE 40 PVC PIPE OR THE EQUIVALENT) EQUIPPED WITH WATERTIGHT JOINTS AND LAID ON A COMPACTED FIRM BASE. 5. THE CONSTRUCTION AND INSTALLATION OF ALL SEPTIC TANKS SHALL CONFORM AT A MINIMUM TO THE LATEST REQUIREMENTS OUTLINED WITHIN 310 CMR 15.226 TO 15.228. 6. ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR A COMPARABLE MEANS IN ORDER TO LOCATE THEM ONCE BURIED. 7. NO DRIVEWAY, PARKING OR TURNING AREA OR OTHER IMPERVIOUS AREA SHALL BE LOCATED ABOVE A SOIL ABSORPTION SYSTEM, EXCEPT WHERE RESTRICTIONS ON THE USE OF THE LAND MAKE IT UNAVOIDABLE. IN SUCH CASES, THE SOIL ABSORPTION SYSTEM SHALL I BE VENTED IN COMPLIANCE WITH 310 CMR 15.241. 8. THE BOTTOM OF EACH SOIL ABSORPTION SYSTEM SHALL BE EXCAVATED TO A LEVEL GRADE. SYSTEMS REQUIRING FILLING TO GRADE SHALL UTILIZE MATERIAL IN COMPLIANCE WITH 310 CMR 15.255. 9. SURFACE DRAINAGE SHALL BE DIRECTED AWAY FROM THE SOIL ABSORPTION SYSTEM AT ALL TIMES. 10. WHERE REQUIRED PER 310 CMR 15.000, VENTED SYSTEMS SHALL BE IN COMPLIANCE WITH 310 CMR 15.241. 11. AGGREGATE WHERE REQUIRED FOR SOIL ABSORPTION SYSTEMS SHALL BE IN ACCORDANCE WITH 310 CMR 15.247. 12. DISTRIBUTION LINES FOR SOIL ABSORPTION SYSTEMS SHALL BE CONSTRUCTED OF EITHER PVC (SCHEDULE 40 GENERAL PURPOSE SEWER PIPE, SCHEDULE 40 DRAIN PIPE, WASTE AND VENT PIPE OR SDR 35 GRAVITY SEWER PIPE AND DRAIN PIPE), ABS (SCHEDULE 40), OR HDPE (ASTM F 810 FOR SMOOTH WALL POLYETHYLENE PIPE FOR USE IN DRAINAGE AND WASTE DISPOSAL FIELDS). 13. ALL APPLICABLE MINIMUM SETBACK DISTANCES FOR SYSTEM COMPONENTS AND SOIL ABSORPTION SYSTEMS SHALL BE IN CQ MPLIANCE WITH 310 CMR 15.211, UNLESS OTHERWISE NOTED AND APPROVED BY LOCAL VARIANCE. WOODEN STAKES (ES WATE�pW o o o AREA TO BE 2'-0" MIN PROTECTED OVERLAP 1214 (MIN. o COMPOST FILTER j i0o wJ a10 / co Q0 l 150 i..1.140 ..1.1 ="� LL , 0 O PLAN WOODEN STAKE (E (M/N.) COMPOST FILTER SOCK AREA TO BE PROTECTED 12 "' M/N. SECTION NOTES. - 1. ALL MATERIAL TO MEET REQUIREMENTS OF SECT/ON 206 OF RI STANDARD SPECIFICATIONS 2. SUBMIT SHOP DRAWING OF COMPOST MATERIAI_ FOR REVIEW AND APPROVAL PRIOR TO PLACEMENT. COMPOST FILTER SOCK NOT TO SCALE (3) Fill material for systems constrLlcted in fill shall consist of select on-site or imparted. soil material. The fill shall be compriscd of 6can granular sand, be free frorn_c>r-anis matter and deleterious substances, and shall nOT contain Rernediatitln Waste as that term is dafined in 31 U CMR 40.0000. Mixtures and layers of dit}crolit classes of soil shall riot he used, Tho fill shall .not Contain any niatcrial 1ca1 gqi" dliin two inG11CS. A sicvc analysts, using a #4 51cvc, shall,bc perfat niecl on a representative sample of the fillA p to 4J'�.!r bye weight cif the fill sample ay be retaizied lin the #4 sieve. Sies'e.analyses also shall be perforated On the fraction of the fill: sample passing the 94 Sieve,, SUC11 citt8lVSe5 1t'1U.St CIE'moLlstrate t1aat the material meets each of the folloNvinb Specifications: I SIEVE SIZE EFFECTIVE %THAT NIUST PARTICLE SIZE PASS SIENVE 4 4.75 min 100`.'✓% 50 0.30 100,310 #104 0.1.5, 111111 00rd, - 20% U200 0.075 nuit 0% - 5;"() A plot of the sieve analyses of the portion of the sample passing the #4 sieve shall..fall_on, or betwceri the lines on the followin« « ranh: n r. 1 Ec:vo, Size MA TITLE V FILL SPECIFICATION Lfl''c ti v- 9; 9i'.016. EqglollF 1500 GALLON SEPTIC TANK 800-696-7432 (SHEA) SHEANew BOX www.sheaconcrete.com MONOLITHIC 4" WALL BILLING ADDRESS: 87 HAVERHILL RD, AMESBURY MA 01913 I, �OT TO SCALE � i _____________________________________________________________ --__------------------__________________________;,__ I 1 i 1 20 DIA CLEANOUT COVER 1 1 1 LACE 1 3 PLACES 1 i -'lit � 1 ; --- - i i1 -------- ----_---- ________________________ll 1 I 1 1 1 1 r. 1 1 1 1 _ 1 101, I L---------------------------------------------------1--------------------------- il BELOW FINISH GRADE 12" NYLOPLAST INLINE DRAIN BODY W/SOLID HINGED COVER PLAN VIEW 6" 4" DIA INLET •< - :'+ <• Yd RUBBER BOOT PART# 2712AG61P* 4" DIA OUTLET W/CLAMP _ 0+ l E i n - BOOT RU i ;-, LER _t-_--- d 3 _1 1 3 - START END < SCH 40 PVC I ` x ' d, COMPACTED PROCESSED 4 µE (,i'iF EsA ; :L=) L .1 L.� € GRAVEL TO 12" AROUND PIPE .4 5'-10„ 6" 1NSERTATEE 4'-7" • ' OTiO?; L 4 -4 OVERLAP NEXT CHAMBER HERE (OVER SMALL CORRUGATION) INSERTA TEE TO BE CENTERED ONSC-740 PART# 6P26FBSTIP*boi- BAFFLE' NAiu 160�- 4" l . . 6" SDR35 PIPE CHAMBER 'y..'a. •�.. .... .. •. t •a.. i - 4"l SECTION VIEW 2" TAPER CREST NOTES: 1. CONCRETE: 4,000 PSI MINIMUM AFTER 28 DAYS. 2. DESIGN CONFORMS WITH 310 CMR, SECTION 15.00 DEP TITLE 5 REGS FOR SEPTIC TANKS 3. ALL REINFORCEMENT PER ASTM C1227. 4 - .TANK SHALL BE ONE -COMPARTMENT 5. TEES AND GAS BAFFLE SOLD SEPARATELY. 6. TONGUE & GROOVE JOINT SEALED WITH BUTYL RESIN. 7. HEAVY DUTY TANK DESIGNED FOR 1 TO 5 FEET OF COVER. ALSO AVAILABLE IN AASHTO HS -20 LOADING. ancr� rrcvuv ll u: rRcrnrctu rvR:. tlLt rvvmt: tkM1500-4.dW M1500H/M15002CH g`. WEIGHT (LBS): DRAWN BY: DATE: PAGE:�" 12,715#/13,320# ARO 06/01/18 B2.5 4Vt 773 Salem Street -Wilmington, MA 1 153 Cranberry Hwy -Rochester, MA 1 87 Haverhill Road -Amesbury, MA ( 160 Old Turnpike Rd -Nottingham, NH Specifications subject to change without notice 1,500 GALLON ONE -COMPARTMENT SEPTIC TANK (SHEA CONCRETE tkM1500-4 OR APPROVED EQUAL) NOT TO SCALE t BASEMENT PORCH WING ROOM Q BATH DINING ROOM KITCHEN J I I Li MUD yEgo L ----J BULKHEAD ROOM �-----� BASEMENT FIRST FLOOR SECOND FLOOR EXISTING HOUSE FLOOR PLANS NOT TO SCALE 4.5" 41 01]r 4» SEWER PIPE 15.7" 24.0" 20.0" " FILTER - SLOTS FILTER 42.. GASKET 4.2" NOTE: FILTER SHALL BE ZABEL MODEL A1800 STANDARD ZABEL EFFLUENT FILTER NOT TO SCALE VALVE BOX COVER TO THREADED PVC PLUG TO BE LABELED "SEWER" FINISHED GRADE VALVE HANDHOLE FRAME AND COVER 4»x2'x2' CONCRETE SUPPORT PAD d, 45' WYE (PVC) 45• ELBOW (PVC) PVC SEWER / 1 fLOW - - SEPTIC CLEANOUT NOT TO SCALE 90.7" (2304 mm) ACTUAL LENGTH I I 4 FILE: 65-3 3 HOLE "D" BOX WITH BAFFLE D B 5-3 F 1 3/4 / ! DESIGN NOTES / s ... 141/2 5 3/4 , 8 I ` I ` 1) FIVE OUTLETS AND THREE INLETS t I 5 1/2 2) INLETS AND OUTLETS HAVE STATE J .... .... I...........L" ......' - _ .......... .................. T. APPROVED SEALSTHAT ACCEPT 4" S-40, 4" SDR -35, 3" AND 2 PIPE. 2112 3) TYPE If CEMENT ASTM C-150-81 4) CONCRETE STRENGTH 5000 PSI MIN. 28 DAYS JOLLEY PRECAST, INC. 860-774-9086 I 0 0 0 Up ilia 110 0 * THE PART# 2712AG61PKIT CAN BE USED TO ORDER ALL NECESSARY 'COMPONENTS FOR A SOLID LID 29.3" 30.0" (744 mm) 0 0 (762 mm) INSPECTION PORT INSTALLATION 12.2" I I_ 45.9" (1166 mm) 51.0" (310 mm) ~I I` (1295 mm) INFILTRATOR 3050 INSPECTION PORT DETAIL NOMINAL CHAMBER SPECIFICATIONS NOT TO SCALE SIZE (W X H X INSTALLED LENGTH) 51.0" X 30.0" X 85.4" CHAMBER STORAGE 45.9 CUBIC FEET MINIMUM INSTALLED STORAGE* 74.9 CUBIC FEET WEIGHT 75.0 lbs. INFILTRATOR 3050 CHAMBER DETAIL, NOT TO SCALE 1 C O M M O N W E ININ, ENGINEERS 8c CONSULTA „All. ... ... 400 SMITH STREET FINISH GRADE 4"D LOAM BACKFILL WITH CLEAN SAND MEETING TOP,OF� PROVIDENCE. RHODE ISLA ELEV. 14.3± & SEED CLEAN SAND 310 CMR 15.255(3) CHAMBER ELEV. 11.52 1a A if, if, i) \\\�\�i��\i\�i\\�\�i\\i/�0. � FILTER -�`- 24" MIN REVISIONS FABRIC t.•N1i t ON-SITE SITE SEWAGE DISF t% Ytw t.iti •4 �, il'i('rPSPR, 1 �F, •' ;<� �+.., No. DATE DRWN CHKD SYSTEM UPGRADE PI 30 u,� , " �>` ,~ . 1 10/29/19 Mcz TJB A.P. 22, LOT 5 u 47 BROADWAY _ ,: ni­ WEST YARMOUTH, MASSACHt BOTTOM OF END CAP 6' MIN - 51" NATIVE SOILS CHAMBER 165"OSSD DETAILS ELEV. 9.02 INFILTRATOR 3050 CHAMBERS; THREE ROWS INFILTRATOR 3050 CHAMBER BED SECTION DETAIL SCALE: AS NOTED SHEET NO: 2 of NOT TO SCALE DRAWN BY: MCZ 7DESIGN BY: MCZ CHECI DISTRIBUTION BOX (JOLLEY PRECAST DB5-3 OR APPROVED EQUAL) I, �OT TO SCALE SET COVER TO 3" 85.4" (2169 mm) INSTALLED LENGTH G5 BUILD ROW IN THIS DIRECTION I r- ' � BELOW FINISH GRADE 12" NYLOPLAST INLINE DRAIN BODY W/SOLID HINGED COVER PART# 2712AG61P* i SOLID COVER: 1299CGC* START END COMPACTED PROCESSED GRAVEL TO 12" AROUND PIPE 6" 1NSERTATEE _ OVERLAP NEXT CHAMBER HERE (OVER SMALL CORRUGATION) INSERTA TEE TO BE CENTERED ONSC-740 PART# 6P26FBSTIP*boi- 160�- 6" SDR35 PIPE CHAMBER CORRUGATION CREST I 0 0 0 Up ilia 110 0 * THE PART# 2712AG61PKIT CAN BE USED TO ORDER ALL NECESSARY 'COMPONENTS FOR A SOLID LID 29.3" 30.0" (744 mm) 0 0 (762 mm) INSPECTION PORT INSTALLATION 12.2" I I_ 45.9" (1166 mm) 51.0" (310 mm) ~I I` (1295 mm) INFILTRATOR 3050 INSPECTION PORT DETAIL NOMINAL CHAMBER SPECIFICATIONS NOT TO SCALE SIZE (W X H X INSTALLED LENGTH) 51.0" X 30.0" X 85.4" CHAMBER STORAGE 45.9 CUBIC FEET MINIMUM INSTALLED STORAGE* 74.9 CUBIC FEET WEIGHT 75.0 lbs. INFILTRATOR 3050 CHAMBER DETAIL, NOT TO SCALE 1 C O M M O N W E ININ, ENGINEERS 8c CONSULTA „All. ... ... 400 SMITH STREET FINISH GRADE 4"D LOAM BACKFILL WITH CLEAN SAND MEETING TOP,OF� PROVIDENCE. RHODE ISLA ELEV. 14.3± & SEED CLEAN SAND 310 CMR 15.255(3) CHAMBER ELEV. 11.52 1a A if, if, i) \\\�\�i��\i\�i\\�\�i\\i/�0. � FILTER -�`- 24" MIN REVISIONS FABRIC t.•N1i t ON-SITE SITE SEWAGE DISF t% Ytw t.iti •4 �, il'i('rPSPR, 1 �F, •' ;<� �+.., No. DATE DRWN CHKD SYSTEM UPGRADE PI 30 u,� , " �>` ,~ . 1 10/29/19 Mcz TJB A.P. 22, LOT 5 u 47 BROADWAY _ ,: ni­ WEST YARMOUTH, MASSACHt BOTTOM OF END CAP 6' MIN - 51" NATIVE SOILS CHAMBER 165"OSSD DETAILS ELEV. 9.02 INFILTRATOR 3050 CHAMBERS; THREE ROWS INFILTRATOR 3050 CHAMBER BED SECTION DETAIL SCALE: AS NOTED SHEET NO: 2 of NOT TO SCALE DRAWN BY: MCZ 7DESIGN BY: MCZ CHECI xf 4, \ / X14.:.Y \ Z 0 x1.6 \ / BENCHMARK r� w � MAG NAIL SET IN PAVEMENT± �� fl' ELEVATION = 13..32 rI.b T Flo �8F \ 111 \ / QP (NA VD 88 ASSESSORS MAP 22 LOT 5 \ \1,.5 ���/ I k.. 9,000± S.F. \ O��G ��� / � O >\oo� •`, .---......,, F �, \FST \ Q 1 ,per ' 4 1�r' �t \ CBASIN \ V/ / x1l, 6 1 r F O l BAY W/NDOW "= CIT8 F 9 c OAF 0 oc�FT ��q'l'c 4 » C. 1. PIPE INV=13.6± P�0r /V SHOWER X/ y V ` / 06o F SFO �9p sem` y LEACH PIT X` X}',%`f'. 14.:5 17 16 BENCHMARK CORNER OF CONC. PAD ELEVATION = 14.46 (NA VD 88 BENC. CORNER 0/ ELEVATIO (NA I GARDEN BOX 4; T. H. SLOG o 0`b�� x14.3 SEPTIC TANK PUMP CHAMBER SEPTIC TANK AND PUMP CHAMBER LOCATIONS BASED ON AS -BUILT PLAN ON RECORD AT YARMOUTH TOWN HALL 10 0 10 Scale I" = 10' NOTES ��i �f4 z, �� { f � r� •� , `" �,. ��,/bn � _� +I t{ � � r � I � ��,"` 4" }�t f�^'2'yi 7 ` 14`'f•hk� T _. r. 4 D4Mi C W 41 14 �1;{v yyytljyti a r-• "h 3 % �,. 3 i y. }b`..Cow may,. (�/� {.c i c t fz' rf.a WE '\ \ Xa �` u 4iC �rlr4kr\ 1 eti trr 4, r a +a,t, , z i � g 7pp Y gilt N'F' Be .i�j.', b �a 71" S7 LOCATION MAP (NOT TO SCALE) 1. PROPERTYLINE DATA FROM "PLAN OF LAND IN YARMOUTH. MADE FOR THE MULVANEY FAMILY REVOCABLE TRUST, DIANNE MULVANEY, TRUSTEE." BY SLADE ASSOCIATES, INC., DATED NOVEMBER 5, 2014, RECORDED AT BARNSTABLE COUNTY REGISTRY OF DEEDS PLAN BOOK 658 PAGE 11. 2. TOPOGRAPHIC SURVEY BY GRADY CONSULTING JUNE 2019. FLOOD NOTE: BY GRAPHIC PLOTTING ONLY, THIS PROPERTY IS PARTIALLY LOCATED IN ZONE "X" OF THE FLOOD INSURANCE RATE MAP, AS DEPICTED ON COMMUNITY PANEL No. 25001C 0569J, WHICH BEARS AN EFFECTIVE DATE OF JULY 16, 2014. SOIL LOG T.H. #1 EL. =14.3 0"" A14 LOAMY SAND 13.1 14"-36" B SAND 11.3 PERC 36"-114" P RX2 " C MIN/IN SAND 4.8 ASSUME HIGH D=9'-6" = WATER AT EL.=4.8 NO (NO FRIMPTER WATER REQUIRED) SOILS TESTING BY BRENDAN KLING, GRADY CONSULTING, L.L.C. JUNE 20, 2019 WITNESSED BY AMY VonHONE EXISTING CONDITIONS PLAN ASSESSORS MAP ' 22 LOT 5 #47 BROADWAY WEST YARMOUTH, MASSACHUSETTS PREPARED FOR: JUNE 10, 2019 MRS. MARCELLINE A. McMANUS SCALE: 1"=10' 369 POND ST, UNIT 310 JOB No. 19-167 ASHLAND, MA 01720 GRADY CONSULTING, L.L.C. e Civil Engineers, Land Surveyors do Landscape Architects 71 Evergreen Street, Suite 1, Kingston, MA 02364 Phone (781) 585-2300 Fax (781) 585-2378 SHEET 1 OF 1