HomeMy WebLinkAboutEngineered Plan - Rev. 2019TOP OF FOUNDATION
ELi 19
EL. 9.0
EL. 8.0"
SECTION DETAIL - COMPONENTS
PROPOSED EL. 11.0'±EL. 11.0'1 NOT TO SCALE
SEPTIC TANK PROPOSED
PUMP CHAMBER PROPOSED
DISTRIBUTION BOX
AT GRADE • COVER• . ~ TO GRPDE Z� RI Imo: �{'�I�li
OF GRADE }COVER
6'
OFF GRADE
PROVIDE WEEP HOLE TO ALARM PPNEL
� PND INS(ALL DUICK OISCONNFI:T-�.
PROPOSED 1,500 GALLOj(._I.I EL. 7.75 �,� LU PRO= 1000 CHAMBER GALLON I❑ EL 7 EL 9.55'
SEPTIC TANK
EL. 7.65'
N INSTALL GAS BAFFLE AT OUTLET
INSTALL EFFLUENT FILTER
DESIGN CALCULATIONS IN OUTLET TEE
FLOW RATE: SURVEY PLAN REFERENCE:
3 BEDROOM DWELLING = 330 G/P D REQUIRED LAND COURT PLAN #21122-A SHEET 8
(110 G/P/D PER BEDROOM x 3BEDROOMS) THIS PLAN IS FOR SEPTIC SYSTEM
DESIGN PURPOSES ONLY,
NO GARBAGE GRINDER ALLOWED THIS PLAN IS NOT FOR BOUNDARY
SEPTIC TANK: DETERMINATION.
330 G/P/D x 2 = 660 G/P/D REQUIRED
USE 1500 GALLON SEPTIC TANK C.B.
SOIL ABSORPTION SYSTEM- 9 10 FOUNC
PERC RATE _ <2 MIN/IN - CLASS I SOIL:;
BOTTOM: (32)(14) = 448 S.F. CATCH
(448)(0.74) = 331 52 G/P/D PROVIDED BASINS
FLOOD ZONE AE
EL. 11' PCL. 71
USE: 1
32' LONG X
' WATER
( 14' WIDE X 0. '
5 DEEP S
LEACH FIELD AS SHOWN IN DETAIL.``
I
DEEP HOLE DATA
PERFORMED BY: JASON C. ELLIS, R.S., S.E.
WITNESSED BY: PHILIP RENAUD, YARMOUTH BOH
TEST DATE: SEPTEMBER 25, 2019
DEPTH 7I � ELEV.
0.00' 10.4'
A
LOAMY SAND
N
O
O 9
d ocal septic Varian
a1 ,!iipjpm%at is required
I a' r, (� S.
ril outh ex tit tDe'saNnlent
APPROVED
MICHAECLLADUE, P.L.S.
LADUE LAND SURVEYING
51 CAPTAIN'S VILLAGE LANE
BREWSTER, MA 02631
N 84'16 11 ' 11 3 11 0 11 " E
,00.00' LOT 35
-� 1,500 S.F.t
W 'non'till,
W � 1 jh��I I,j, h II' EXISTING
IIII�I 1 1 CESSPOOL
I I' DECK II (REMOVE)
I EXISTING I Ill i l �i4I LjI
11 T O
DWELL
G �l II� I'II I!
'Z \ /EL. 11.95 _
0
W 0 \
10
11
PROPOSED '
SEPTIC TANK /
DRIVEWAY
N
ELEC. PUMP CHAMBER
BOX 100.00'
S S4-16'30" `T(
1 • C.B.
U.P. (FOUND
�Q I
a.._ 10
PUMP CHAMBER: I
USE (1) 1,000 GALLON SEPTIC TANK
USE MYERS PUMP SRM4 4/10 HP OR EQUIVALENT
FLOAT SETTINGS: PUMP ON = 14"PUMP OFF
ALARM ON = 16"
STORAGE CAPACITY PROVIDED = 666 GALLONS
MINIMUM 4 CYCLES REQUIRED PER DAY
MAXIMUM REQUIRED PER DOSE CYCLE: 82.5 GALLONS
VOLUME PROVIDED PER DOSE CYCLE: 64.8 GALLONS
PCL. 73
ING
LW 77
�X1�1� 7/
1
Co
LP
0
0
INSPE(
PORT
C.B.
FOUND
LEACH
FIELD
PROPOSED
SOIL ABSORPTION SYSTEM
(1) 32' K 14' x 0.5' LEACH FIELD
2. OF 1/8 -
DOUBLE WASHED
EL.9.38' 3/4-
�, DOUBLE
PROVIDE END CAP
AT ENDS OF ALL -
LATERALS
EL. 8.6'
4.5' T2.5 _ EL OBS. = 2.07' EL ADL = 3.57' C7
YP 5' GROUND WATER ELEVATION
N / EXCAVATION REFERENCE WELL = TSW-89 ZONE A
AUGUST 2019 LEVEL = 11.62'
' " I ADJUSTMENT FACTOR = 1.5'
NOTES
1. ALL PRECAST COMPONENTS TO BE H-10 RATED. ALL
COMPONENTS WITH ANY ANTICIPATED VEHICULAR TRAFFIC
I N TO BE H-20 RATED.
2. ELEVATION DATUM IS FROM USGS QUAD MAP.
3. MUNICIPAL WATER IS AVAILABLE.
4. ALL CONSTRUCTION TO CONFORM WITH 310 CMR 15.000
AND ALL OTHER APPLICABLE LOCAL, STATE AND FEDERAL
Un - CODES AND REGULATIONS.
I I 1 5. INSTALLER/CONTRACTOR TO REVIEW & VERIFY ALL
ELEVATIONS AND DETAILS AND REPORT ANY DISCREPANCIES
W \ ` TO DESIGNER PRIOR TO CONSTRUCTION OR ASSUME ALL
u -j- RESPONSIBILITY
q DISTRIBUTION
BOX DISTRIBUTION
1-9BOX
TYP.
PCL. 78 S.A.S. DETAIL
JF6,UND BENCHMARKTOP OF CONC. BOUNDEL. 10.3' M.S.L.±CL. 74
PROPOSED
LEACH FIELD
15. LEACH AREA TO BE PROVIDED WITH AT LEAST ONE
INSPECTION PORT CONSISTING OF A PERFORATED FOUR INCH
PIPE PLACED VERTICALLY DOWN INTO THE STONE TO THE
NATURALLY OCCURING SOIL OR SAND FILL BELOW THE STONE.
THE PIPE SHALL BE CAPPED WITH A SCREW TYPE CAP AND
ACCESSIBLE WITHIN 3" OF GRADE.
16. SEPTIC TANK AND PUMP CHAMBER TO BE INSTALLED
WATER PROOFED.
17. SEPTIC TANK AND PUMP CHAMBER TO BE INSTALLED
ON COMPACTED, STABLE BASE.
C.B.
FOUND
PROPERTY OWNER AND
CONTRACTORS TO VERIFY
ALL WATER LINES AND GAS
UTILITIES ON PROPERTY.
J.C. ELLIS DESIGN
P.O. BOX 81
NORTH EASTHAM, MA 02651
(508)240-2220
Email: joson®jcellisdesign.com
6. INSTALLER/CONTRACTOR IS RESPONSIBLE FOR MAINTAINING
SAFE WORK AREA, VERIFING ALL UTILITIES AND NOTIFYING
DIG SAFE PRIOR TO CONSTRUCTION.
7. ANY CHANGES TO OR DEVIATIONS FROM THIS PLAN MUST
BE APPROVED IN WRITING BY J.C. ELLIS DESIGN CO. AND
BOARD OF HEALTH.
B. FINISH COVER OVER COMPONENTS IS NOT TO EXCEED 3'
PER 310 CMR 15.000.
9. ALL ABANDONED SEPTIC SYSTEM COMPONENTS TO BE
PUMPED DRY AND REMOVED AND REPLACED WITH CLEAN
MEDIUM SAND.
10. ALL COMPONENTS TO BE PROVIDED WITH WATERTIGHT
ACCESS PORTS WITHIN 6" OF FINISH GRADE.
11. ALL SEPTIC TANKS, DISTRIBUTION BOXES AND PIPING TO
BE INSTALLED WATERTIGHT.
12. NO KNOWN WELLS EXIST WITHIN 100' OF PROPOSED
LEACH AREA.
13. THIS IS NOT A CERTIFIED PLOT PLAN AND UNDER NO
CIRCUMSTANCES IS THIS PLAN TO BE USED FOR BUILDING
OR ZONING PURPOSES.
14. EXCAVATE ALL UNSUITABLE SOIL AS NECESSARY (A & B
LAYERS ONLY) 5' AROUND AND UNDER S.A.S. DOWN TO C
LAYER AND REPLACE WITH CLEAN MEDIUM SAND.
SEPTIC SYSTEM UPGRADE PLAN
9.24'
B
LOAMY SAND
10YR3/6
2.33'
8.07'
C
MEDIUM SAND
2.5Y6/6
Permit
PERC 0 60"
€)til,§
<2 MIN./IN.
Boar
atty! '
9.33'
107 scwagF
WATER ENCOUNTERED 0 100' Ji
(EL 2.07')
�h
1
Pit I!
N
O
O 9
d ocal septic Varian
a1 ,!iipjpm%at is required
I a' r, (� S.
ril outh ex tit tDe'saNnlent
APPROVED
MICHAECLLADUE, P.L.S.
LADUE LAND SURVEYING
51 CAPTAIN'S VILLAGE LANE
BREWSTER, MA 02631
N 84'16 11 ' 11 3 11 0 11 " E
,00.00' LOT 35
-� 1,500 S.F.t
W 'non'till,
W � 1 jh��I I,j, h II' EXISTING
IIII�I 1 1 CESSPOOL
I I' DECK II (REMOVE)
I EXISTING I Ill i l �i4I LjI
11 T O
DWELL
G �l II� I'II I!
'Z \ /EL. 11.95 _
0
W 0 \
10
11
PROPOSED '
SEPTIC TANK /
DRIVEWAY
N
ELEC. PUMP CHAMBER
BOX 100.00'
S S4-16'30" `T(
1 • C.B.
U.P. (FOUND
�Q I
a.._ 10
PUMP CHAMBER: I
USE (1) 1,000 GALLON SEPTIC TANK
USE MYERS PUMP SRM4 4/10 HP OR EQUIVALENT
FLOAT SETTINGS: PUMP ON = 14"PUMP OFF
ALARM ON = 16"
STORAGE CAPACITY PROVIDED = 666 GALLONS
MINIMUM 4 CYCLES REQUIRED PER DAY
MAXIMUM REQUIRED PER DOSE CYCLE: 82.5 GALLONS
VOLUME PROVIDED PER DOSE CYCLE: 64.8 GALLONS
PCL. 73
ING
LW 77
�X1�1� 7/
1
Co
LP
0
0
INSPE(
PORT
C.B.
FOUND
LEACH
FIELD
PROPOSED
SOIL ABSORPTION SYSTEM
(1) 32' K 14' x 0.5' LEACH FIELD
2. OF 1/8 -
DOUBLE WASHED
EL.9.38' 3/4-
�, DOUBLE
PROVIDE END CAP
AT ENDS OF ALL -
LATERALS
EL. 8.6'
4.5' T2.5 _ EL OBS. = 2.07' EL ADL = 3.57' C7
YP 5' GROUND WATER ELEVATION
N / EXCAVATION REFERENCE WELL = TSW-89 ZONE A
AUGUST 2019 LEVEL = 11.62'
' " I ADJUSTMENT FACTOR = 1.5'
NOTES
1. ALL PRECAST COMPONENTS TO BE H-10 RATED. ALL
COMPONENTS WITH ANY ANTICIPATED VEHICULAR TRAFFIC
I N TO BE H-20 RATED.
2. ELEVATION DATUM IS FROM USGS QUAD MAP.
3. MUNICIPAL WATER IS AVAILABLE.
4. ALL CONSTRUCTION TO CONFORM WITH 310 CMR 15.000
AND ALL OTHER APPLICABLE LOCAL, STATE AND FEDERAL
Un - CODES AND REGULATIONS.
I I 1 5. INSTALLER/CONTRACTOR TO REVIEW & VERIFY ALL
ELEVATIONS AND DETAILS AND REPORT ANY DISCREPANCIES
W \ ` TO DESIGNER PRIOR TO CONSTRUCTION OR ASSUME ALL
u -j- RESPONSIBILITY
q DISTRIBUTION
BOX DISTRIBUTION
1-9BOX
TYP.
PCL. 78 S.A.S. DETAIL
JF6,UND BENCHMARKTOP OF CONC. BOUNDEL. 10.3' M.S.L.±CL. 74
PROPOSED
LEACH FIELD
15. LEACH AREA TO BE PROVIDED WITH AT LEAST ONE
INSPECTION PORT CONSISTING OF A PERFORATED FOUR INCH
PIPE PLACED VERTICALLY DOWN INTO THE STONE TO THE
NATURALLY OCCURING SOIL OR SAND FILL BELOW THE STONE.
THE PIPE SHALL BE CAPPED WITH A SCREW TYPE CAP AND
ACCESSIBLE WITHIN 3" OF GRADE.
16. SEPTIC TANK AND PUMP CHAMBER TO BE INSTALLED
WATER PROOFED.
17. SEPTIC TANK AND PUMP CHAMBER TO BE INSTALLED
ON COMPACTED, STABLE BASE.
C.B.
FOUND
PROPERTY OWNER AND
CONTRACTORS TO VERIFY
ALL WATER LINES AND GAS
UTILITIES ON PROPERTY.
J.C. ELLIS DESIGN
P.O. BOX 81
NORTH EASTHAM, MA 02651
(508)240-2220
Email: joson®jcellisdesign.com
6. INSTALLER/CONTRACTOR IS RESPONSIBLE FOR MAINTAINING
SAFE WORK AREA, VERIFING ALL UTILITIES AND NOTIFYING
DIG SAFE PRIOR TO CONSTRUCTION.
7. ANY CHANGES TO OR DEVIATIONS FROM THIS PLAN MUST
BE APPROVED IN WRITING BY J.C. ELLIS DESIGN CO. AND
BOARD OF HEALTH.
B. FINISH COVER OVER COMPONENTS IS NOT TO EXCEED 3'
PER 310 CMR 15.000.
9. ALL ABANDONED SEPTIC SYSTEM COMPONENTS TO BE
PUMPED DRY AND REMOVED AND REPLACED WITH CLEAN
MEDIUM SAND.
10. ALL COMPONENTS TO BE PROVIDED WITH WATERTIGHT
ACCESS PORTS WITHIN 6" OF FINISH GRADE.
11. ALL SEPTIC TANKS, DISTRIBUTION BOXES AND PIPING TO
BE INSTALLED WATERTIGHT.
12. NO KNOWN WELLS EXIST WITHIN 100' OF PROPOSED
LEACH AREA.
13. THIS IS NOT A CERTIFIED PLOT PLAN AND UNDER NO
CIRCUMSTANCES IS THIS PLAN TO BE USED FOR BUILDING
OR ZONING PURPOSES.
14. EXCAVATE ALL UNSUITABLE SOIL AS NECESSARY (A & B
LAYERS ONLY) 5' AROUND AND UNDER S.A.S. DOWN TO C
LAYER AND REPLACE WITH CLEAN MEDIUM SAND.
SEPTIC SYSTEM UPGRADE PLAN