HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. (LZ- Lot `/7 Zone of Contribution: In_ Out �' Acreage
Commercial: Residential: ----P-
Street: 2/ ,a/ L Z /
Village: (' Floor Plan: ✓ #Bedrooms: 1
Owner: 7 Installer: 7%�i./Y'"
Address: Phone:
Phone:
Builder: Engineer: &,--- it-ii-e-i
Address: Phone: - f ��Jr'
Phone: �4? S
N/A YES NO
1. Required#of copies received ti,-
2.Date of soils exam and percolation test not older than 2 years L.---""
3.4-5 ft of naturally occurring pervious material,above water table l-----
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: L/
5. Water line 10 ft from septic components Var.:
6.Benchmark indicated and shown-NGVD if near wetlands l..----*
7. Septic tank minimum 10 ft from foundation,deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: $----
9. Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: MR t-----
11. Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.: 1-.----
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj.water or bo 0 o to: . - •• . .:
15. System not in top or subsoil(A,B horizo .)or 5'remova
16.Proposed contours are suitable C/6/416. - v: C7 ' c
17. System meets slope requirements-min. 1/8", 'A"preferred
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper,gas baffle on outlet tee .�---"
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal
22. System adequately sized for its intended use if
23.Minimum 6"stone or compacted below tank and dbox L.,•- --
24.Manhole covers within 6"of grade,pump chamber cover to grade ll
25. Inspection port on plastic chambers/leach field
L.--"--
26. Electrical permit for pump chamber/Separate meter for duplexes `___,--
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size
-.._...-----
28. Septic tank/pump chamber to be factory waterproofed .......----
29.
/29. Vent provided if leaching below 3 feet, under driveway/parking L.------
30. Buoyancy calculations for tank/pump chamber
....-----
31. Engineer to inspect and certify soils: wall: commercial: ,__
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ..-----
33. H-20 loading is subject to vehicular traffic,groundwater ._--------
34.
_/34. Title V Application and permit fee, installer signature (-'�'
35.Foundation footing min.2 feet above adjusted ground water for new house
36. Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: 6/03/03