Loading...
HomeMy WebLinkAboutBLDE-19-006235 �. Commonwealth of Official Use Only 4-1111% Massachusetts Permit No. BLDE-19-006235 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:5/6/2019 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 3 SHELBURNE RD Owner or Tenant PEREIRA MIGUEL Telephone No. Owner's Address PEREIRA TANIA, 3 SHELBURNE RD,WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead ❑ Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system. (24 Panels) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. ,Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: LLOYD R SMITH Licensee: Lloyd R Smith Signature LIC.NO.: 15688 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:30 1ST ST, MELROSE MA 021764010 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 4(A(C )/ Commonwealth o/i®laddachudettd Official Use Only i! t> Permit No Lag —��J5 2epartment of ire Serviced' OccupanBOARD OF FIRE PREVENTION REGULATIONS [Rev. 071 and Fee Checked (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(;MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: G Tj I O a I tq City or Town of: (A.M.(5501 To the Inspector of Wires: By this application the undersigns gives notice of his or her intention to perform the electrical work described below. Location(Street&Number)3 51�11pti,( Parcel ID: Owner or Tenant -11AA ia, :j„. (( Telephone No."73ti•3(f657 -5 Owner's Address &\fy t. as 0 X , pIs this permit in conjunction with a building permit? Yes 71 No D (Check Appropriate Box) `--J Purpose of Building )weAv(1 Utility Authorization No. Existing Service (VO Amps 1M. / Z140 Volts Overhead Undgrd❑ No.of Meters New Service Amps / Volts Overhead/ Undgrd ❑ No.of Meters Number of Feeders and Ampacity ,, Location and Nature of Proposed Electrical Work: ty-1 ic1,1koC' uel 04. ma MC k4- eA ",, :_, ncAbkitslrtt c. A c)'•o S\A-ve r\. 2_y ' Itt IS . Completion of the following table may be waived by the Inspector of Wires. iN No.of Total No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle) Fans Transformers KVA . i ( \ No.of Luminaire Outlets No.of Hot Tubs Generators KVA v No.of Luminaires Swimming Pool Above ❑ In- ❑ ivo.of N:mergency Lighting b grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones_ I No.of Switches No.of Gas Burners No.of Detection and _ Initiating Devices No.of Ranges No.of Air Cond. Total No.of AlertingDevices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices _ No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection No.of Dryers Heating Appliances KW Security Systems:* No. f Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: /1 Attach additional detail i/desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: 13 0 G 1. oo (When required by municipal policy.) Work to Start: 06 f�p� (C Inspections to be requested in accordance with MEC Rule l0,and upon completion. INSURANCE CO RA E: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE S.. BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application '•true and complete. FIRM NAME: V.1 f t�( 4 S o\c ie j e..t C. e r LLC LIC.NO.: Licensee:La.1D_y d.Srr Signature L l LIC.NO.: )ST.,00? (If applicable.,,enter e, pt"in the lice nu er line.) ous.Tel. No.:1 k`-'-fl-i (j2-2q Address: 2-LI U LAY-C'(1 44--Ps S'{rIic j� 0 I SWr Alt.Tel.No.: W L4 Ct�l *Per M.G.L. c. 147,s. 57-61,security work requires Department of Publi Safety"S" License: Lic. No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below, I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent PERMIT FEE:$ (0� Signature Telephone No. �� 11• • •l, 'S GOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES a. 2015 INTERNATIONAL RESIDENTIAL CODE b. 2017 NATIONAL ELECTRICAL CODE c. ANY OTHER LOCAL AMENDMENTS SHEET INDEX: COVER SHEET PV 1.0-SITE PLAN S 1.0-MOUNT DETAILS E 1.0-ELECTRICAL DIAGRAM E 2.0-ELECTRICAL NOTES E 3.0-WARNING LABELS E 4.0-WARNING LABEL LOCATIONS GENERAL ELECTRICAL NOTES: GENERAL STRUCTURAL NOTES: 1. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL a. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING MEANS DESIGNED AND LISTED FOR SUCH USE.FOR ROOF-MOUNTED THE ROCK-IT SYSTEM BY ECOFASTEN.THE MOUNTING FEET ARE TO BE SYSTEMS,WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF SPACED AS SHOWN IN THE DETAILS,AND MUST BE STAGGERED TO THE ROOF SURFACE. ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2. ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE b. UNLESS NOTED OTHERWISE,MOUNTING ANCHORS SHALL BE¶Ii', LAG CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2;5"PENETRATION INTO ROOF FRAMING. 3. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE c. THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. _,heNlurne Rd 4. RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE d. ROOF LIVE LOAD=20 psf TYPICAL 0 psf UNDER NEW PV SYSTEM. INVERTER.RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCEe. GROUND SNOW LOAD=30 psi VOLTAGE. f. WIND SPEED=140 mph aul�c Nd 3 SI IE Uur rr Hued 5. SEE"E 1.0 AND`E 2.0 FOR DIAGRAMS,CALCULATIONS,SCHEDULE AND g. EXPOSURE CATEGORY=B 5ftprhAR' SPECIFICATIONS. Vivint"Solar 1800ASHTON BLVD.LEHI,UT,84043 1.877.404.4129 MA LICENSE: HIC-1 70848, ME-15888A,SS-002342 PHOTOVOLTAIC SYSTEM SPECIFICATIONS: PEREIRA RESIDENCE SYSTEM SIZE-7.440kW DC 7.600kW AC 3 SHELBU RD WEST YARMOUTH,TM,MA,02673 MODULE TYPE&AMOUNT-(24)Jinko Solar JKM310M-60BL WITH 24 SolarEdge P320 OPTIMIZERS UTILITY ACCOUNT#;1430 468 0045 Or r301 m µu MODULE DIMENSIONS-(L/W/H)65.55/39.45"/1.38" INVERTER-(1)SolarEdge Technologies SE7600H-US000BNC4 SERVICE a:s-6096539 REGIONALCOVER o.yr„tiM,�'s = INTERCONNECTION METHOD-LOAD BREAKER OPERATING CENTER;MA-03 DATE.4/26019 G:f SHEET DRAWN BY:DIN PV STRING(S): f GOOF SECTION(S): SYSTEM LEGEND 1 SLOPE-34 ® #1)12 MODULES IMUTH•171 PV SYSTEM SIZE: MATERIAL- NEW 7.440kW DC I 7.600kW AC #2)12 MODULES COMPOSITION SHINGLE NO NEW INTERIOR MAIN SERVICE PANEL TIED TO UTILITY METER 42308320. 171 NEW SMART PRODUCTION METER.LOCATED WITHIN ID'OF MSP. NEW R110SY PV STEM AC DISCONNECT.LOCATED 3 SHELBURNE RD WITHYSTEMI. 1 NEW PV SYSTEM INVERTER.SolarEdge Technologies FRONT OF HOUSE. SETROSIV 1S000BNC4(RSD EQUIPPED) 24 NEW JINKO SOLAR JKM310M-60BL MODULES. NEW SOLAR EDGE P320 OPTIMIZERS,MOUNTED ON THE BACK OF EACH MODULE. NEW PV CONDUIT RUN.'SEE EEI.0 CONDUIT SCHEDULE }, _—=EXTERIOR RUN—————=ATTIC RUN Y NEW JUNCTION BOX.(MOUNTED TO PV MODULE) 0 M 1=1 EXISTING UTILITY METER. #2308320 0 O &\\\• x v'S\N d 0 0 o vivint.Solar 1.877.404.4129 PEREIRA RESIDENCE 3 SHELBURNE RD WEST YARMOUTH.MA.02673 UTILITY ACCOUNT#:1430 468 0045 SITE PLAN SEGRVICEDNAL OPERATINGk S-6096533 CENTER'.MA-03 PV 1=0 DATE:4.26.2019 SCALE:118"=1-0" DRAWN BY DIN • MOUNTING LEGEND `r COMP SHINGLES ��\ ROLK4A COUPLING :�. MID CLAMP ,,.(`, f,TA 41,. ROCK-IT COUPLING ROCK-IT COUPLING © ir`# �� MID CLAMP - MID CLAMP t`e'1 r \VISY • \I�`• yZ „. .,� j ® ROCK-IT COUPLING SHELF TIT • ,,, 0. , I. "�' y ROCK-IT ��' ROCK-IT SLIDE SHIP LAP � PEDESTAL METAL FLASHING ROCK-IT METAL (INSTALLED PER MANUFACTURE'S INSTRUCTIONS)TIE PLATE 5/16•x11/2. COUPLING SHELFHEX �' 6/16DOLT == FLASHING ISOMETRIC VIEW 300 SER IES ES SSGE LT HEX FLANGE BOLT SIDE VIEWISOMETRIC VIEW • 300 SERIES SS ��'� A N COMP SHINGLES `t f SS LAG SCREW TORQUE-13r2 FT-LBS. `� it6 ml SIDE VIEW 1 B ILSCO SGB-4 GROUNDING LUGS -�i-C-1��'- 510 ».mx E 1 ROCK-IT MOUNT2 ROCK-IT COUPLING ASSEMBLY i U.L. LISTING FORECU�ASTEN'VW NOT TO SCALE nECHr tin NOT TO SCALE S 1.0 S 1.0 roav w CLAMP ATTACHMENT CLAMP*ATTACHMENT PERMITTED COUPLING CA T LEVER L/3 OR LESS COUPLING I I CLAMP SPACING ANDSCAPE=MAX 48•(4') COUPLING POR �(4) CLOMP I"'I I"'! RAFTER MODULE 11111111 •OCK-IT SLIDE MODU RAFTER I1'tl I'''! RAFTER METAL I'1 1 T T 1 T T 1 MODULE Illillil FLASHINGI PDMBONOEDWASHER IT II II l� I' II Il —� FORMS IVATERTIGHT REAL 1 I RAFTER 7X61 AT 16-0 C. 1■ 4 ' SYSTEM MOUNTING DETAIL 5 ODULES IN PORTRAIT/LANDSCAPE L•PORTRAIT • 5 1.D NOT EO SCALE 5 1.0 Not.To SCALE L-A' G COMP SHINGLES 2 1/2 MIN 3•MIN AND 6"MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE MIN 5/16•DIAM Mt: ONE HOLE STEEL STRAP CONDUIT SS LAG SCREW PV MODULE,TYP.MOUNT dik TORQUE=13:2 FT-LBS. `j�' TO FRAMING OF EXISTING `, �J ROOF TYPE.PARALLELMei •'\ Y\,i d n{tLT .SoIar WITH PLANE OF ROOF CONDUIT MOUNT BRACKET J, - s'MAXNAUI I 1 2• 1.877.404.4129 SECTION VIEW '/' FLASHING OR TILE STRAP �� I PEREIRA RESIDENCE ..vnos:r.Escn+r �wt,•is,;r��ew-ritiri+.i•"~-.;w��rnn.,u:L•T.r+ri-�.;ti� 3 SHELBURNE RD WEST YARMOUTH,MA,02673 3 — — — SECTION VIEW UTILITY ACCOUNT#:1430 468 0045 NOT TO SCALE 6 • ARRAY TYP.ELEVATION ®CONDUIT MOUNTING DETAIL S 1.0 s B NOT m KWX normuae t. SERVICE R S-6096538 MOUNT DETAILS REGIONAL 1.0 OPERATING CENTER:MA-03S 1 DATE:4)26(2019 - SCALE:NOT TO SCALE DRAWN BY DIN Photovoltaic System Conduit Conductor Schedule(ALL CONDUCTORS MUST BE COPPER) DC System Size(Watts) _ 7440 Tag 6 Description Wire Gauge U of Conductors/Color Conduit Type Conduit Size in AC System Size(Watts) 7600 1 PV Wire 12 AWG 2(V+,V-) N/A-Free Air N/A-Free Air g Total Module Count _ 24 - 1 Bare Copper Ground-EGC 6 AWG 1 BARE N/A-Free Air N/A-Free Air $ o 2 THWN-2 12 AWG 4(2V+,2V-)B/R EMT 1/2" v u, ¢ m 2 THWN-2 EGC 12 AWG 1(GRN) EMT 1/2" y z 2 ,r 3 THWN-2 8AWG 3(1L1 1E2 1N)B/R/W EMT 3/4" cc _ 3 THWN-2 EGC 10 AWG 1(GRN) EMT 3/4" a, N 0 8 d m `m Q 0 1 0 E.a C 4.: Iiiv cn 7 a Solar Edge g 5E7600H-US 03 'Conforms to ANSI in C12.1-2008 PV Softens SMART Meter > .3 ti > Z W C C Z W Point of Interconnection,Load Side ¢ Q j Rapid Shutdown 71)5.171R11711111h1 N H et rn Disconnect, OPEN TRANSITION© Z z 2 tO STRING 2:12 PV t 2 1 Square 0 — SHEET MODULES DU222R8 N.' NAME: W/OPTIMIZERS 240V/60A Inri.cnd Mcr.zna \ New 240V/125A MIL'�'1' INE 1� Service i m 100A Single Phase,with C C STRING 1:12 PV i 2 12 'Y lit \ III D00A Main 3 Disconnect J MODULES ,,,. NEMA4 Sanction Bon I� M LOAD en c W/OPT1MIZERS n T SHEET i_` — s_ �' a0A BACKUP PANEL NUMBER: 24PV MODULES PER INVERTER=7440 WATTS I t STC Visible/Lockable'Knife'AC Minimum GEC size 4-44 Disconnect AWG copper W PV Module Rating @ STC Conductor Calculations Module Make/Model linko Solar JKM310M-60BL Wire gauge calculated from code art.310.15(B)(16)with ambient temperature calculations from m Max.Power-Point Current(Imp) 9.4 Amps a, p n art.310.15(B)(2)(a). c cc N Max.Power-Point Voltage(Vmp) 33 Volts For"On Roof"conductors we use the 90'C column ampacity,the relevant ambient temperature -o Z a ,mr Open-Circuit Voltage(Voc) 40.5 _Volts adjustment,and raceway fill adjustments from 310.15(B)(16). v D ,. Optimizer Solar Edge P320 Short-Circuit Current(Isc) 9.92 Amps For"Off Roof'conductors we use the 75'C column ampacity,or the 90"C column ampacity with A cb 5 DC Input Power 320 Watts Max.Series Fuse(OCPD) 20 Amps the relevant ambient temperature and raceway fill adjustments,whichever is less. 'd N E o' DC Max.Input Voltage 48 Volts Nom.Max.Power at STC(Pmax) 310 •Watts The rating of the conductor after adjustments MUST be greater than,or equal to,the continuous a m „ a DC Max.Input Current 13.75 Amps Max.System Voltage 1000 VDC(UL/IEC) duty uprated output current. > DC Max.Output Current 15 Amps Voc Temperature Coefficient -0.29 1 %/C Calculation Example-Wire Rating(90°C)x Ambient Temperature Adjustment x Conduit Fill Max.string rating inverter dependent.See SE documents. Adjustment>=Continuous Duty Output Current Inverter Make/Model Solar Edge 5E7600H-Us AC Output Current According to art.690.8(B)(1) 31.67 Amps (On Roof,Tag 2):12 gauge wire rated for 30 A, 30 A x 1 x 0.8(4 Conductors)=24 A>=18.75 A CEC Efficiency 99 % Nominal AC Voltage 240 Volts (Off Roof,Tag 3):8 gauge wire rated for 50 A, 50 A>=39.58 A AC Operating Voltage 240 Volts THIS PANEL IS FED BY MULTIPLE SOURCES(UTILITY AND SOLAR) Cont.Max.Output Current 32 Amps (13 DC Max.Input Current 20 Amps Rooftop conductor ampacities designed in compliance with art. Short Circuit Current 40 Amps 690.8,Tables 310.15(B)(2)(a),310.15(B)(3)(a),310.15(B((3)(c), Max.Output Fault Current 40 A/20 ms 310.15(B)(16),Chapter 9 Table 4,5,&9. Location specific ? temperature obtained from ASHRAE 2017 data tables. ...... ASHRAE 2017- C oi Highest Monthly 2%D.B.Design Temp.:29.1°C • ei Lowest Min.Mean Extreme D.B.:-19.2°C • Xi Tt m - a N N OCPD Calculations a Breakers sized according to continuous duty output current.PV circuit nominal current based off c n inverter continuous output current X(1.25(art.690.8(A))). O3 m Inverter 1:SE7600H-US Max Output=31.67 A x 1.25[art.690.8(A)] i m o =39.58 A<40 A(OCPD) S m •-, system output current w/continuous duty=39.58<40A(System OCPD) i Z ,;, u, W Z J N V, H < or Other Notes ? ? •Designed according to,and all code citations are relevant to,the NEC 2017. SHEET •All interior raceways carrying DC current shall be metallic. NAME: s m z a SHEET NUMBER: N W • ih Conduit,Raceways,and 1-Boxes (Labeled Every 10')Per Plaques and Directories at the Service Equipment(MSP)and the SE7600H-US String 1 DC Disconnecting Means Per 690.53 690.31(G)(3)&(4) Location of All System Disconnects Per 690.56(B)&705.10 o oi PHOTOVOLTAIC DC POWER SOURCE DISCONNECT ,c WARNING:PHOTOVOLTAIC POWER SOURCE CAUTION: STRING 1 a re G m POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE MAXIMUM VOLTAGE: 400 V Z FOLLOWING SOURCES WITH DISCONDIETS LOCATEP'AS MAXIMUM CURRENT: 15 A ,r D cic .z - Interactive System Point of Interconnection Per 690.54 m E -. SHOWN DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: 15 A 'S I 'o S PHOTOVOLTAIC AC POWER SOURCE = RATED AC OUTPUT CURRENT:31.67 A AT`f31 a p Q NOM.OPERATING AC VOLTAGE:240 V r: METER AND MAIN SERVICE SE7600H-US String 2 DC Disconnecting Means Per 690.53 ' 1.1. i i 'AC DISCONNECT DC DISCONNECT PHOTOVOLTAIC DC POWER SOURCE DISCONNECT 5 PV System Disconnects Per 690.13(B) INVERTER STRING 2 PV SYSTEM DISCONNECT (`1 1 ---' MAXIMUM VOLTAGE: 400 V MAXIMUM CURRENT: 15 A DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: 15 A All Disconnecting Means Per 690.13(B)&690.15(D) WARNING PV With Rapid Shutdown,Installed Within 3 ft of the Service { ELECTRICAL SHOCK HAZARD Disconnecting Means Per 690.56(C)(1)(a) TERMINALSON THE LINE AND LOADSIDES SOLARRI SYSTEM EQUIPPED MAABE Y BE ENERGIZED IN THE OPEN POSITION tip Power Source Output Connection,Adjacent to Back- wrrtt RAPID SHUTDOWN .c m fed Breaker Per 705.12 - 44 WARNING • ,v POWER SOURCE OUTPUT CONNECTION TURN RAPID SHUTDOWN v DO NOT RELOCATE THIS OVERCURRENT SWITCH TO THE irorAa.7_.8 m DEVICE "OFF"POSITION TO � SHUTDOWN PV SYSTEM u AND REDUCE Rapid Shutdown Switch Per 690.56(C)(3) SHOCK HAZARD IN ARRAY MI RAPID SHUTDOWN SWITCH FOR o z El. w Otri ' W E l' n • z rl • Z ,:i ..4W W W W M • 7 N Z Z Q O SHEET NAME: m c C N m a m a SHEET NUMBER: ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY SHALL BE REFLECTIVE,THEY SHALL CONTAIN NO SMALLER THAN 3/8"WHITE ARIAL FONT TEXT,AND HAVE A RED BACKGROUND,UNLESS OTHERWISE DEPICTED OR DESCRIBED. to ALL PLACARDS SHALL BE WEATHER-RESISTANT,PERMANENTLY ETCHED PLACARDS.HANDWRITTEN SIGNS WILL NOT BE ACCEPTABLE. ui C MAIN BREAKER DE-RATED TO"`DUE TO SOLAR PHOTOVOLTAIC AC POWER SOURCE PHOTOVOLTAIC DC POWER SOURCE DISCONNECT u CIRCUITS J RATED AC OUTPUT CURRENT:•"•A ��J MAXIMUM VOLTAGE: ***A *"*-value calculated for each ul MAX OF***AMPS PV SOURCE ALLOWED NOM.OPERATING AC VOLTAGE:***V MAXIMUM CURRENT: ***V account,for specific value see the 4, o 2 DO NOT INCREASE MAIN BREAKER RATING Property of Vivint Solar DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: ***A previous warning label page d W N c Property of Vivint Solar (- Property of Vivint Solar -o z a 5 WARNING:PHOTOVOLTAIC POWER SOURCE j ® WARNING Property of Vivint Solar ( Cj SITE PLAN PLACARD SHOWING ADDITIONAL POWER SOURCE m S. > ELECTRICAL SHOCK HAZARD \�JJ TERMINALS ON THE LINE AND LOAD SIDES MAYBE "" WARNING AND DISCONNECT LOCATIONS.PLACARD SHALL BE m E ENERGIZED IN THE OPEN POSITION 6 POWER SOURCE OUTPUT CONNECTION MOUNTED ON EXTERIOR OF ELECTRICAL PANEL >- Property of Vivint Solar �J DO NOT RELOCATE THIS OVERCURRENT DEVICE Property of Vivint Solar ( PV SYSTEM DISCONNECT Property of Vivint Solar r -• / Property of Vivint Solar (// \\ 1� PV rapid shutdown label required by �� RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 690.56(C)(1)indicated on E.3 Property of Vivint Solar LO 0 ti) f. C • 05 • N C m v L IF APPLICABLE 9 ,-, ROOFTOP ARRAY $C) INSIDE PANEL INSIDE PANEL 0 ,^, a EVERY 10'AND �, c g 50�PaG2Q $C) 4 O 1 IF APPLICABLE li O 9p'�F..�<<4 OI IF APPLICABLE Le Ln H `'? 2 i O 19 > 7 DC M O W W z O DISCONNECT c ¢ J INSIDE z z f 1 • ——— ——. — . ——— —— SHEET •, SOLAR INVERTERS COMBINER PANEL VISIBLE/LOCKABLE VIVINT SOLAR METER VISIBLE/LOCKABLE SUB PANEL MAIN SERVICE NAME: JUNCTION (MAY BE ON ROOFTOP (WHEN USED) A/C DISCONNECT (WHERE REQUIRED) A/C DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL e0 O INTEGRATED WITH (WHERE REQUIRED) c N BOX ARRAY) TYPICAL SOLAR GENERATION INSTALLATION as a CD m (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) 3 3 a SHEET ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY SHALL THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT(DC)CONDUIT, NUMBER: BE REFLECTIVE,THEY SHALL CONTAIN NO SMALLER THAN 3/8"WHITE ARIAL FONT TEXT,AND ENCLOSURES,RACE-WAYS,CABLE ASSEMBLIES,JUNCTION BOXES COMBINER BOXES,AND DISCONNECTS TO ALERT HAVE A RED BACKGROUND,UNLESS OTHERWISE DEPICTED OR DESCRIBED.ALL PLACARDS THE FIRE SERVICE TO AVOID CUTTING THEM.MARKINGS SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT(3048 SHALL BE WEATHER-RESISTANT,PERMANENTLY ETCHED PLACARDS.HANDWRITTEN SIGNS WILL MM),ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES,WALLS OR BARRIERS. a NOT BE ACCEPTABLE. ui