Building Air Tightness Test
Ir ED I SEP 2 4 2019 Building Air-Tightness Test Form ,U'LDINE;DEPgRT-ENT- Customer Information: Building&Test Conditions: Name: Paul Butler Address: 25 Jerome Ave. Date: 9/23/2019 City: Bloomfield State/Zip: CT/06002 Phone: (860)983-7884 Time: 5:30 P.M. Email: Building Address; (if different from above) Street: 25 Parker's Neck Rd. Floor Area (ft2): 2454 s.f. City/State: South Yarmouth, MA Comments: Permit#: 19-001195 Issued: 9/14/2018 Standard Level Accuracy Mechanical Ventilation: (2) Exhaust-Only Bath Fans w/24-hr Timer Switches 65 CFM = Minimum Continuous Exhaust Flow Rate in Accordance with ASHRAE62.2(2013) 85 CFM = 45 min./hr run-time 100 CFM = 39 min./hr run-time Test#1 Depress: V Press: Test#2 Depress: V Press: Pre-test Baseline Pressure: - 0.4 (Pa) Pre-test Baseline Pressure: - 0•5 (Pa) Bldg Press. Flow Ring Fan Press Flow Bldg Press. Flow Ring Fan Press Flow (Pa) Installed (Pa) (cfm) (Pa) Installed (Pa) (cfm) -50.4 B -50.8 913 -50.1 B -50.6 915 -50.5 B -50.9 910 -50.0 B -50.5 909 -50.2 B -50.6 915 -50.4 B -50.9 910 -50.0 B -50.4 917 -50.3 B -50.8 912 -50.1 B -50.5 910 -50.2 B -50.7 916 Post-test Baseline Pressure: -0.6 (Pa) Post-test Baseline Pressure: -0.6 (Pa) Fan Model/SN: Minn BD 130927 Fan Model/SN: Minn BD 130927 Results: Results: CFM50: 913.0 CFM50: 912.4 ACH50: 2.9 ACH50: 2.9 HERS Rater Name and Cert.#: Chris Picariello Cert.#: 6397177 HERS Rater Signature and Date: •' 9/23/2019 Developed by Advanced Building Analysis,LLC