Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH r SEWAGE PLAN REVIEW CHECKLIST Location: A.M. .Z- Lot /74 Zone of Contribution: In Out Ce Acreage - �� 7� 4-0../ Commercial: Residential: )O Street: ,� - / Village: (/U( i Ir € d!/' Floor Plan: v #Bedrooms: Owner: /-hatr-/-.. Installer: A64- 16 At- Address: ( ( Phone: S6 E-X32- 0 5 Phone: Builder: Engineer: .4A--/'Y L- Address. Phone: •ArrZ- m� Phone: ( (o , )-17; N/A 2/1-- teva,i YES NO 1.Required#of copies received l./ 2. Date of soils exam and percolation test not older than 2 years li 3.4-5 ft of naturally occurring pervious material,above water table L/ 4.Foundation 2 ft above high point of road H.P.:• Fnd: Var.: A---- 5. /5.Water line 10 ft from septic components Var.: (.------ 6. ./6.Benchmark indicated and shown-NGVD if near wetlands ✓/ 7. Septic tank minimum 10 ft from foundation, deck Var.: i/ 8. Leaching minimum 20 ft full, 15 ft crawl, l0 ft slab Var.: 2J C," ( J rl 9.Leaching minimum 100 ft from wetlands Var.: v----- 10. ./10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: �� 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: ,It__.. d;2- 1.------1.- 14. ��14.Leaching set 4-5 ft above adj.water or botto es Var.: 15. System not in top or subsoil(A,B horizons) r 5'remov 16.Proposed contours are suitable i/' 17. System meets slope requirements-min. 1/8", '/a"preferred 18. System meets breakout requirements PVC liner: Wall: L'' - 19. Specified tee sizes are proper,gas baffle on outlet tee k_.../--- 20. _�20. Sewage is under 10,000 gpd for parcel `/ 21.No garbage disposal �/ 22. System adequately sized for its intended use L� 23.Minimum 6"stone or compacted below tank and dbox .......----- 24. /24.Manhole covers within 6"of grade,pump chamber cover to grade c...------ 25. f25.Inspection port on plastic chambers/leach field L.----- 26.Electrical permit for pump chamber/Separate meter for duplexes `/ 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size L..------ 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet,under driveway/parking _ 30. Buoyancy calculations for tank/pump chamber ,/- 31. /31. Engineer to inspect and certify soils: wall: commercial: _/ 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33. 1-1-20 loading is subject to vehicular traffic,groundwater ,/ 34. Title V Application and permit fee, installer sigture ./ 35.Foundation footing min. 2 feet above adjusted ground water for new house .� 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37.Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: Qt 1 6✓03iO3