Loading...
HomeMy WebLinkAboutBLDE-19-006000 ItA% of Official Use Only if /IA Massachusetts Permit No. BLDE-19-006000 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:4/23/2019 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 115 CAPT BESSE RD Owner or Tenant LANE DARREN A Telephone No. Owner's Address 115 CAPT BESSE RD, SOUTH YARMOUTH, MA 02664 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Solar Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE ❑ BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: LLOYD R SMITH Licensee: Lloyd R Smith Signature LIC.NO.: 15688 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:30 1ST ST, MELROSE MA 021764010 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 Cr1.06et 740611 4i'ili 9 commonwealth.o//6'Iaddackcaettd Of Use O ly 1* et cc�� c7 i -'f, .2 epartment o/}ire�erenced Permit No. - E- Occupancy and Fee Checked - BOARD OF FIRE PREVENTION REGULATIONS [Rev. I/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR,`PE ALL INFORMATION) Date: i3t), `O, City or Town of: J. IA curry[n,L To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. > Location(Street&Number)\\S 1[•�,h4. � su C . Parcel ID: / Owner or Tenant in0`�0"b` t�-'[ k,t.araa Telephone No. .3 •aGjO t N Owner's Address &x$fVL as ahoJes ,..D Is this permit in conjunction with a building permit? Yes Z No J (Check Appropriate Box) Purpose of Building -D we.\V(\ Utility Authorization No. Existing Service 1CO Amps / Z.140 Volts Overhead Undgrd❑ No.of Meters wa6Service Amps / Volts Overhead/ Undgrd n No.of Meters ;-• I I inpber of Feeders and Ampacity i . 1oc tion and Nature of Proc. posed Electrical Work: l fvi1o1 04 Ma M Ai 1 LU nCAkxACUG :»ACk S\fAke..rn• 8,31- v a Is' rk21S . ti 0i Completion of the,b ilowing table may be waived by the Inspector of Wires. °- R No.of Total .r� , o. f Recessed Luminaires No.of Ceil.Susp.(Paddle)Fans $,j" , ' Transformers KVA i-• --- v-gi plf Luminaire Outlets No.of Hot Tubs Generators KVA — two.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting b grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of AlertingDevices Tons No.of Waste Disposers Heat PumpNumber Tons KW No.of Self-Contained Total Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other . Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Water No.of No.of No.of Devices or Equivalent - Heaters KW Signs Ballasts Data Wiring: g No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent _ OTHER: ,4ttach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: III IN • oia (When required by municipal policy.) J.Work to Start:c)�j ' Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE OVE GE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ES. BOND ❑ OTHER ❑ (Specify:) I certify, under the pains and penalties of perjury,that the information on this application '• rue and complete. FIRM NAME: v'v in* S o cir �Q,kit.1 C 2C L.L-� LIC.NO.: Licensee:L IN't .. Sw , Signature i� , t LIC.NO.: I Stnc� (If applicable enter "ewe"in the lice a na er line.) bus.Tel.No.:18 L/l1^UZ-a0 Address: �Li U t c{t,J c {AsS�t�(Z J O (Stc Alt.Tel.No.:gaW-'2i{) e-n *Per M.G.L. c. 147,s. 57-61,securityu work requires Department of Publit Safety"S"License: Lic. No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below, I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent / Signature Telephone No. PERMIT FEE:$ I u . . ") . • '-'.444 • I 4 • • . • I , - • 4 • . • 1 1" • •1, '• GOVERNING CODES ALL WORN SHALL CONFORM TO THE FOLLOWING CODES a. 2015 INTERNATIONAL RESIDENTIAL CODE b. 2017 NATIONAL ELECTRICAL CODE c. ANY OTHER LOCAL AMENDMENTS SHEET INDEX: COVER SHEET PV 1.0-SITE PLAN S 1.0-MOUNT DETAILS E 1.0-ELECTRICAL DIAGRAM E 2.0-ELECTRICAL NOTES E 3.0-WARNING LABELS E 4.0-WARNING LABEL LOCATIONS GENERAL ELECTRICAL NOTES: GENERAL STRUCTURAL NOTES: Nr,y,a HY,;,t Ra 1. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL a. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING MEANS DESIGNED AND LISTED FOR SUCH USE.FOR ROOF-MOUNTED THE SFM SYSTEM BY UNIRAC.THE MOUNTING FEET ARE TO BE SPACED AS SYSTEMS,WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF SHOWN IN THE DETAILS,AND MUST BE STAGGERED TO ADJACENT FRAMING THE ROOF SURFACE. MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. • c,a.4 ,,o a I 2. ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE b. UNLESS NOTED OTHERWISE,MOUNTING ANCHORS SHALL BE Xo"LAG CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2X"PENETRATION INTO ROOF FRAMING. 3. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE c. THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. 4. RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE d. ROOF LIVE LOAD=20 psi TYPICAL 0 psf UNDER NEW PV SYSTEM. INVERTER.RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCES. GROUND SNOW LOAD=30 psi VOLTAGE. f. WIND SPEED=140 mph I .„ `H,, 5. SEE*E 1.0 AND*E 2.0 FOR DIAGRAMS,CALCULATIONS,SCHEDULE AND g. EXPOSURE CATEGORY=B v i v i n t.S o l a r SPECIFICATIONS. _ 115 Captain Besse Road 1800 ASHTON BLVD.LEAI,UT, Z. 1.877.404.4129 w MA LICENSE: HIC-170848, a t ME-15688A,SS-002342/ $_ , PHOTOVOLTAIC SYSTEM SPECIFICATIONS: 1 DE MIRANDA RESIDENCE 1,, , 115 CAPTAIN BESSE RD x SYSTEM SIZE-8.370kW DC 17.600kW AC SOUTH YARMOUTH,MA.02884 MODULE TYPE&AMOUNT-(27)JINKO SOLAR JKM310M-60BL WITH 27 SolarEdge P320 OPTIMIZERS UTILITY ACCOUNT a:14806310034 J L MODULE DIMENSIONS-(LIW/H)66.34"I 39.37"/1.26" T INVERTER-(1)SolarEdge Technologies SE7600H-US000BNC4 SERVICE 4: REGIONAL COVER INTERCONNECTION METHOD-LOAD BREAKER OPERATING CENTER:MA-03 DATE.4/1912019 SHEET ,.,,a vn Pe ac 11,5 vDRAWN BY:DIN �/ PV STRING(S): PROOF SECTION(S): SYSTEM LEGEND (1)SLOPE-31 _---...-.- ® k1)14 MODULES AZIMUTH-168 PV SYSTEM SIZE: MATERIAL- NEW 8.370kW DC I 7.600kW AC ® #2)13 MODULES COMPOSITION SHINGLE ▪ EXISTING INTERIOR MAIN SERVICE PANEL TED ▪ TO UTILITY METER 02399827. 115 CAPTAIN BESSE RD p , RUFMSPUCTION METER.LOCATED FRONT OF HOUSE. ® NEW PV SYSTEM AC DISCONNECT. LOCATED WNHIN 10'OF MSP. ' 1 NEW PV SYSTEME7600H-U5000BNC4 INVERTER:EQUIPPED)SolarEdge Technologies S (RSD 27 NEW JINKO SOLAR JKM310M60BL MODULES. NEW SOLAR EDGE P320 OPTIMIZERS.MOUNTED ON THE BACK OF EACH MODULE. NEW PV CONDUIT RUN.'SEE EELS CONDUIT SCHEDULE _ EXTERIOR RUN - -- =ATTIC RUN Y NEW JUNCTION BOX,(MOUNTED TO PV MODULE) Ei EXISTING UTILITY METER. 9 2399827 0 N.\:\\\,,,,\...*,, N\ 5 i \\\:\ \ \\ ` \\\ 0 / A ... _.„ , ___,, vivint.Solar 1.877.404.4129 DE MIRANDA RESIDENCE 115 CAPTAIN BESSE RD SOUTH YARMOUTH,MA.02664 UTILITY ACCOUNT N:1480631D034 4 SITE PLAN SERVICEL 5ED91049� REGIONAL PV 1 .0 RA DATE:W192019 SCALE:3/16"=1-0' DRAWN BY DIN . ., 40 2 � ) f� $ \ } i lr-v? , ! ► ¥ ` )} ; , \ A 7 : ir�—e ! I , § !E `_ ) (/ f1- ; i °/ § I9I1 ; § ! m , , - Q ( \ ) § 5 ` 4 < } ` • ) � : I `co 0n ' . 5,Q f § Z ' d 4 . /§ le # / \ 2 , \ / $ , / �v 82 X ) Rk 0 m | �~ E Pik -. / § \ [ I 88l',( �\ . | ' • � �� ` ]2 , |�M ?. i ��_ §\ /�-- )-- -- ! • ; ,! <:1 ;1 ' 9\! 4� ;> 83 ` . $ �� Ek ! [ \ . § \ \\ �� § � . �� t o ¥ ) ! $) § ,) ` m ` ■ § $ m ^ > < , ` j ( / 7§ 2 ■ _K . 0 § k/` t \k ' § ` z{,), r+ j 3x . ; r Cn k/mk ! , o. . i ; ' m � aa § � � � § o ( ' m \ \ \ 7 \ ..- 2 2 ( Photovoltaic System Conduit Conductor Schedule(ALL CONDUCTORS MUST BE COPPER) DC System Size(Watts) 8370 Tag It Description Wire Gauge If of Conductors/Color Conduit Type Conduit Size a a AC System Size(Watts) 7600 1 PV Wire 12 AWG 2(V+,V-) N/A-Free Air N/A-Free Air a, o to mo 0 Total Module Count 27 1 Bare Copper Ground-EGC 6 AWG 1 BARE N/A-Free Air N/A-Free Air C' ' 2 THWN-2 12 AWG 4(2V+,2V-)B/R EMT 1/2" u, om m F 2 THWN-2 EGC 12 AWG 1(GRN) EMT 1/2" Z 8 .� 3 THWN-2 8 AWG 3(1L1 1L2 1N)B/R/W EMT 3/4" 2 ii 3 THWN-2 EGC 10 AWG 1(GRN) EMT 3/4" Ls e- `e L°, 8 y O j COo j f: C • m w cr cri w m V m N N a a 0 V. Solar Edge cc m SE7600H-US ri• •Conforms to ANSI ON N C12.1-2008 PV System SMART Meter Z O Point of Interconnection,Load > Rapid Shutdown Side 705.12(83211311b) > Z iu Disconnect,Square D w cc Z DU222RB 240V/60A v Unfused,NEMA3,or Lt LIN 5 o N N Q Oai 7..\., equivaient,with75'CSTRING 2:13 PV 1 2 13 terminations MODULES M SHEET W/OPTIMIZERS t 7� i NAME: 9 LINE /5� 100A Existing 240VJ125A c ( - Y ' ---------� Service Panel,Single C '; STRING 1:14 PV 0 2� © L J Phase,Existing 2 SODA Main l0 �p Disconnect an 0 MODULES NEMA4 JuncOon Box V LO Et/� W/OPTIMIZERS . . © T ,., : 3 40A SHEET 1r r n ) NUMBER: 27PV MODULES PER INVERTER=6370 WATTS - -- --'-- _-- T - —� ® —' --------_-_-�" T STC sihle/Lockable'Knife'AC Minimum DEC size6 vi Disconnect AWG copper 111 PV Module Rating @ STC Conductor Calculations Module Make/Model link)Solar JKM310M-60BL u o N o Max.Power-Point Current(Imp) 9.4 Amps Wire gauge calculated from code art.310.15(8)(16)with ambient temperature calculations from `w z < m Max.Power-Point Voltage(Vmp) 33 Volts art.310.15(B)(2)(a). - W =For"On Roof"conductors we use the 90°C column ampacity,the relevant ambient temperature w m Open-Circuit Voltage(Voc) 40.5 Volts s adjustment,and raceway fill adjustments from 310.15(B)(16). z D '" Optimizer Solar Edge P320 Short-Circuit Current(Ise) 9.92 Amps For"Off Roof'conductors we use the 75°C column ampacity,or the 90°C column ampacity with c a o E DC Input Power 320 Watts Max.Series Fuse(OCPD) 20 Amps the relevant ambient temperature and raceway fill adjustments,whichever is less. S Q .4 ,DC Max.Input Voltage 48 Volts Nom.Max.Power at SIC(Pmax) 310 Watts The rating of the conductor after adjustments MUST be greater than,or equal to,the continuous d _ < DC Max.Input Current 13.75 Amps Max.System Voltage 1000 VDC(UL/IEC) duty uprated output current. o .' 1 DC Max.Output Current 15 Amps .Voc Temperature Coefficient -0.29 I %/C Calculation Example-Wire Rating(90"C)x Ambient Temperature Adjustment x Conduit Fill S S Max.string rating inverter dependent.See SE documents. Adjustment>=Continuous Duty Output Current Inverter Make/Model Solar Edge SE7600H-US AC Output Current According to art.690.8(B)(1) 31.67 Amps (On Roof,Tag 2):12 gauge wire rated for 30 A, 30 A x 1 x 0.8(4 Conductors)=24 A>=18.75 A CEC Efficiency 99 % Nominal AC Voltage 240 Volts (Off Roof,Tag 3):8 gauge wire rated for 50 A, 50 A>=39.58 A AC Operating Voltage 240 Volts THIS PANEL IS FED BY MULTIPLE SOURCES(UTILITY AND SOLAR) _,. Cont.Max.Output Current 32 Amps it DC Max.Input Current 20 Amps Rooftop conductor ampacities designed in compliance with art. Short Circuit Current 40 Amps 690.8,Tables 310.150B)(2)(a),310.15(B)(3)(a),310.15(B)(3)(c), r Max.Output Fault Current 40 A/20 ms 310.15(B)(16),Chapter 9 Table 4,5,&9. Location specific temperature obtained from ASHRAE 2017 data tables. 4:. ASHRAE 2017- :1 a, Highest Monthly 2%D.B.Design Temp.:29.1°C rn Lowest Min.Mean Extreme D.B.:-19.2°C • ii v w v rn r.1 OCPD Calculations 8 e Breakers sized according to continuous duty output current.PV circuit nominal current based off cc n inverter continuous output current X(1.25[art.690.8(A))). 5 m Oin ri m Inverter 1:SE7600H-US Max Output=31.67 A x 1.25[art.690.8(A)] z w o_ =39.58 A<40 A(OCPD) system output current w/continuous duty=39.58<40A(System OCPD) W W so W 0, a .I $ Other Notes ? ? •Designed according to,and all code citations are relevant to,the NEC 2017. SHEET •All interior raceways carrying DC current shall be metallic. NAME: d d o ua Z d SHEET NUMBER: N W AA Conduit,Raceways,and 1-Boxes(Labeled Every 10')Per Plaques and Directories at the Service Equipment(MSP)and the SE7600H-US String 1 DC Disconnecting Means Per 690.53 a, o N 8 690.31(G)(3)&(4) Location of All System Disconnects Per 690.56(B)&705.10 c Oc a r„ PHOTOVOLTAIC DC POWER SOURCE DISCONNECT 0 WARNING:PHOTOVOLTAIC POWER SOURCE CAUTION: '9 o STRING 1 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE MAXIMUM VOLTAGE: 400 V ' 00 il 4 Interactive System Point of Interconnection Per690.S4 FOLLOWING SOURCE$WITH DISCONNETS LOCATED AS MAXIMUM CURRENT: 15 A v a O c SHOWN DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: 15 A ` L i u PHOTOVOI TAIC AC POWER SOURCE - _ RATED AC OUTPUT CURRENT:31.67 A AT ® Y :INOM.OPERATING AC VOLTAGE:240 V I � `� ,,'.! .METER AND MAIN SERVICE SE7600H-US String 2 DC Disconnecting Means Per 690.53 0 I-�I_I I '\- AC DISCONNECT 0 _ t-1 DC DISCONNECT PHOTOVOLTAIC DC POWER SOURCE DISCONNECT 's PV System Disconnects Per 690.13(B) INVERTER - STRING 2 PV SYSTEM DISCONNECT -, MAXIMUM VOLTAGE: 400 V 1--. MAXIMUM CURRENT: 15A All Disconnecting Means Per 690.13(B)&690.15(D) DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: 15 A WARNING PV With Rapid Shutdown,Installed Within 3 ft of the Service i ELECTRICAL SHOCK HAZARD Disconnecting Means Per 690.56(C)(1)(a) TERMINALS ON THE LINE AND LOAD SIDES SOLAR PV SYSTEM BOPPED i.x MAY BE ENERGIZED IN THE OPEN POSITION Willi �``��.{ V!!l g 1 A'):fV l: Power Source Output Connection,Adjacent to Back- el: F fed Breaker Per705.12 — • m WARNING a POWER SOURCE OUTPUT CONNECTION TURN RAPID SHUTDOWN -o DO NOT RELOCATE THIS OVERCURRENT SWITCH TO THE �yy DEVICE "OFF"POSITION TO _, 1p SHUTDOWN PV SYSTEM , v AND REDUCE Rapid Shutdown Switch Per 690.56(C)(3) SHOCK HAZARD IN ARRAY 1111 N RAPID SHUTDOWN SWITCH FOR v v 0 a n cc m O v z cn I— w Z O > Z ui w w Z rn H H g Z 2 2 t8 Ic SHEET NAME: m e •C i e w ea .0 Lia 33 a SHEET NUMBER: ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY SHALL BE REFLECTIVE,THEY SHALL CONTAIN NO SMALLER THAN 3/8"WHITE ARIAL FONT TEXT,AND HAVE A RED BACKGROUND,UNLESS OTHERWISE DEPICTED OR DESCRIBED. M ALL PLACARDS SHALL BE WEATHER-RESISTANT,PERMANENTLY ETCHED PLACARDS.HANDWRITTEN SIGNS WILL NOT BE ACCEPTABLE. LI C / a.MAIN BREAKER DE-RATED TO"**DUE TO SOLAR ` 41I PHOTOVOLTAIC AC POWER SOURCE PHOTOVOLTAIC DC POWER SOURCE DISCONNECT ** m CIRCUITS U RATED AC OUTPUT CURRENT:***A t$� MAXIMUM VOLTAGE: ***A *-value calculated for each �, p a 8 MAX OF***AMPS PV SOURCE ALLOWED NOM.OPERATING AC VOLTAGE:***V MAXIMUM CURRENT: ***V account,for specific value see the 'a' z ¢ m DO NOT INCREASE MAIN BREAKER RATING Property of Vivint Solar DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: ***A previous warning label page a W o Property of Vivint Solar �C\ Property of Vivint Solar 00 4 4 _7 WARNING:PHOTOVOLTAIC POWER SOURCE o Z O @ WARNING �/ Property of Vivint Solar ( C� SITEJ PLAN PLACARD SHOWING ADDITIONAL POWER SOURCE d o ELECTRICAL SHOCK HAZARD o AND DISCONNECT LOCATIONS.PLACARD SHALL BE -' S c TERMINALS ON THE LINE AND LOAD SIDES MAY BE WARNING MOUNTED ON EXTERIOR OF ELECTRICAL PANEL o '4 j ENERGIZED IN THE OPEN POSITION 6 POWER SOURCE OUTPUT CONNECTION Property of Vivint Solar �� DO NOT RELOCATE THIS OVERCURRENT DEVICE Property of Vivint Solar D C PV SYSTEM DISCONNECTProperty of Vivint SolarProperty of Vivint Solar /// 10PV rapid shutdown label required by RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 690.56(C)(1)indicated on E.3 Property of Vivint Solar a f4. i!1 C • Of d to. 1 N IF APPLICABLE . ROOFTOP ARRAY 7 INSIDE PANEL 6 INSIDE PANEL 0 9 e EVERY 10'AND ^► fp�OG2 8 L O gs 2 O Q 0 1 IF APPLICABLE g Fl OPQF" !!L IF APPLICABLE � z� m O O O id Z a DC W CZ rn r, DISCONNECT F a ' a INSIDE z z ——— __ __- *__, ——— — SHEET SOLAR INVERTERS COMBINER PANEL ^VISIBLE/LOCKABLE VIVINT SOLAR METER VISIBLE/LOCKABLE SUB PANEL MAIN SERVICE NAME: JUNCTION O (MAY BE ON ROOFTOP (WHEN USED) A/C DISCONNECT (WHERE REQUIRED) A/C DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL m BOX INTEGRATED WITH (WHERE REQUIRED) N ARRAY) TYPICAL SOLAR GENERATION INSTALLATION a a m (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) 3 3 a SHEET ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY SHALL THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT(DC)CONDUIT,ENCLOSURES, NUMBER: BE REFLECTIVE,THEY SHALL CONTAIN NO SMALLER THAN 3/8"WHITE ARIAL FONT TEXT,AND RACE-WAYS,CABLE ASSEMBLIES,JUNCTION BOXES COMBINER BOXES,AND DISCONNECTS TO ALERT THE FIRE HAVE A RED BACKGROUND,UNLESS OTHERWISE DEPICTED OR DESCRIBED.ALL PLACARDS SERVICE TO AVOID CUTTING THEM.MARKINGS SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT(3048 MM),ABOVE SHALL BE WEATHER-RESISTANT,PERMANENTLY ETCHED PLACARDS.HANDWRITTEN SIGNS WILL AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES,WALLS OR BARRIERS. e{ NOT BE ACCEPTABLE.